Butterfly House - Construction21
Transcription
Butterfly House - Construction21
Etu d e d e ca s : B u tte r fl y Ho u s e S i te We b : h ttp ://www.co n s tr u cti o n 2 1 .o r g /fr a n ce / Butterfly House PUBLIÉ PAR JIROJWONG | 16 JUIN 16 Type de pro jet : Co nstructio n Neuve Type de bâtiment : Maiso n individuelle iso lée o u jumelée Année de co nstructio n : 20 0 5 Zo ne climatique : [Aw] Tro pical humide avec hiver sec. Surface nette : 120 m 2 SHON Co ût de co nstructio n : 38 0 0 0 € No mbre d'unités fo nctio nnelles : 1 Lo gement Co ût/m² : 317 €/m 2 Co ût/Lo gement : 38 0 0 0 €/Lo gement , 3419 0 Ubo n Ratchathani, Thailand // Description This is an energy efficient ho use that was built by the University o f Ubo nratchathani in 20 0 5 as part o f a research pro ject funded by the Ministry o f Energy o f Thailand. 2-sto rey ho use with 2 bedro o ms o n the seco nd flo o r and living space do wnstairs is made o f co ncrete structure. Upper flo o r plate is bigger to act as shading fo r lo wer o ne. The distinct feature is a chimney aligned at center o f the ho use to ventilate during the daytime. The ro o fs are break into 2 pieces and tilted like butterfly wings shape into the chimney to create the pressure different fo r venturi effect under the ro o f and gain benefit fro m night radiatio n. Mo reo ver, all main functio ns are catego rized as service zo ne and living zo ne, o riented and break them by the chimney. Fiabilit é de s do nné e s : Auto -déclaratio n // Intervenants Architecte No m : Africvs info @africvs.co m Site Web : http://www.africvs.co m/ Actio n : Green building adviso r Mo de co nt ract ue l : Partenariat Public Privé Dé m arche dé ve lo ppe m e nt durable du m aît re d'o uvrage : The building is co nstructed as a pro to type o f mo dern residential building. Passive building techniques are applied to this pro ject such as stack ventilatio n, radiative co o ling, venturi effect, self-shading and building o rientatio n. The building is equipped with thermo co uple to study o n an effect o f these design technique. De script io n archit e ct urale : 2-sto rey ho use with 2 bedro o ms o n the seco nd flo o r and living space do wnstairs is made o f co ncrete structure. Upper flo o r plate is bigger to act as shading fo r lo wer o ne. The distinct feature is a chimney aligned at center o f the ho use to ventilate during the daytime. The ro o fs are break into 2 pieces and tilted like butterfly wings shape into the chimney to create the pressure different fo r venturi effect under the ro o f and gain benefit fro m night radiatio n. Mo reo ver, all main functio ns are catego rized as service zo ne and living zo ne, o riented and break them by the chimney. // Energie Consommation énergétique Be so in e n é ne rgie prim aire : 8 2,50 kWh PE/m 2 /year Be so in e n é ne rgie prim aire bât im e nt st andard : 8 6 ,58 kWh PE/m 2 /year Mé t ho de de calcul : Autre CEEB : 0 ,0 0 kWh PE / € Co nso m m at io n d'é ne rgie f inale : 75,0 0 kWh FE/m 2 /year Ré part it io n de la co nso m m at io n é ne rgé t ique : Lighting 2% Air co nditio n 8 6 % Ceiling fan 1% Equipment 9 % Misc 2% Performance énergétique de l'enveloppe UBat de l\'e nve lo ppe : 0 ,43 W.m -2 .K-1 Plus d'inf o rm at io n sur l'e nve lo ppe : Typical material fo r wall is co mpo sed o f lightweight co ncrete blo ck with cellulo se fiber cement o utside and 1" po lyurethane fo am in between to blo ck external heat gain and mo isture. Fo r fenestratio n area, o cean green flo at glass is utilized due to the lo w shading co efficient pro perty (SC=0 .59 ) while the visible ray transmittance is high (VT = 0 .72) to maximize the benefit fro m daylight. Ro o f has do uble layers to create venturi effect fo r attic ventilatio n. // EnR & systèmes Systèmes Chauf f age : Aucun système de chauffage ECS : Aucun système d'eau chaude sanitaire Raf raîchisse m e nt : Ventilo -co nvecteur Ve nt ilat io n : Ventilatio n naturelle Ventillatio n no cturne Ene rgie s re no uve lable s : Aucun système de pro ductio n d'énergies reno uvelables High-efficient air-co nditio ners (EER > 12) // Environnement // Produits Chimney Fabricant : Africvs Co .,Ltd. | Chimney is a part o f architectural design. Co nt act f abricant : info @africvs.co m Sit e Int e rne t f abricant : http://africvs.co m/ Cat é go rie de pro duit : Gro s œuvre / Système passif De script io n: Vertical cavity fo r ventilatio n, mo st effectively in the daytime Co m m e nt aire s: Temperature inside the ho use is reduced. // Coûts Co ût de co nstructio n : 38 0 0 0 € Coûts de construction & exploitation Co ût de s syst è m e s d'é ne rgie s re no uve lable s : Co ût é t ude s : 3 8 50 ,0 0 € Co ût t o t al : 38 50 0 ,0 0 € 0€ // Environnement urbain Enviro nne m e nt urbain : Surf ace du t e rrain : Lo cated o n a large o pen space area with prevailing wind mo st fro m the so uth 224 m 2 Surf ace au so l co nst ruit e : Espace s ve rt s co m m uns : Parking : 40 % 80 1 parking underco ver // Qualité environnementale du bâti Qualit é e nviro nne m e nt ale du bât i : co nfo rt (o lfactif, thermique, visuel) efficacité énergétique, gestio n de l\'énergie // Concours Since the pro ject is selected to be in a final ro und o f energy saving ho use design co mpetitio n by Energy Po licy & Planning Office o f Thailand, intended to be a mo del fo r design technique study, the pro ject is co nstructed. This ho use is co mpo sed o f vario us passive design technique such as stack ventilatio n, night radiatio n, venturi effect, self-shading and building o rientatio n. The building is equipped with thermo co uple to study o n an effect o f these design technique.