Sheet D Imperial Working Drawing Template

Transcription

Sheet D Imperial Working Drawing Template
Door Schedule
Quantity Door Number Door Type
U/S of existing steel pan deck
1
Existing baffle to remain.
100
A
101
1
Suspended acoustical tile ceiling.
Existing
Door
Width/Height/Thickness Material
+914mm+2134mm 45mm
532mm active leaf
Aluminum door
w/ glass insert
+914mm+2134mm 45mm
Pressed steel
acoustic door
Frame
Hardware Set No. Notes
Finish Material Finish
N/A
P3
Aluminum
frame
Hollow Metal
N/A
P3
N/A
H1
N/A
Refer to door
elevation for
details.
INFRASTRUCTURE SERVICES & COMMUNITY SUSTAINABILITY /
SERVICES D'INFRASTRUCTURE ET VIABILITÉ DES COLLECTIVITÉS
INFRASTRUCTURE SERVICES BRANCH /
DIRECTION D'INFRASTRUCTURE
DESIGN AND CONSTRUCTION DIVISION /
DIVISION DE LA CONCEPTION ET DE LA CONSTRUCTION
DEPUTY CITY MANAGER / DIRECTEUR DES SERVICES MUNICIPAUX
DIRECTOR / DIRECTEUR
MANAGER / GESTIONNAIRE
FOR / POUR
CORPORATE SERVICES
REAL PROPERTY ASSET MANAGEMENT
DESIGN & CONSTRUCTION
Acoustical Building Felt Liner.
"L" trim (Typical).
Building Standard Ceiling 'T' Clip.
92mm 25 gauge steel metal studs @
410mm o.c. c/w 2 layers of 16mm
gypsum board both sides. Tape, fill &
sand smooth ready for paint or other
finish.
211-2141 Thurston Drive
Ottawa ON K1G 6C9
T 613-739-3699
F 613-739-3965
LWG-ai.com
[email protected]
65mm sound attenuation batts suitable
for metal stud application.
Baseboard as applicable.
Metal runner (Typical).
Acoustical caulk.
Line of finished floor as applicable.
6
5
Line of existing concrete slab.
1
ID6
4
Issued for tender
28-08-2013
MB
3
Issued for Final review
12-08-2013
MB
2
Issued for 90% review
23-07-2013
MB
1
TI- Interior Partition - Underside of T-bar Ceiling
NUMBER/
NUMÉRO
1:2
26-06-2013
Issued for 60% review
MILESTONE / FAIT SAILLANT
DATE:
DG
DG
MB
1:100
MB
(Y/M/D)
(A/M/J)
INITIALS
INITIALES
DETAIL NUMBER
1 DRAWING TITLE
A1.1 SCALE:
SHEET NUMBER
THIS DRAWING IS THE PROPERTY OF
THE CITY OF OTTAWA AND ALL
COPYRIGHT IS RESERVED.
DIMENSIONS ON DRAWING ARE FOR
ESTIMATING PURPOSES ONLY. IT IS
THE RESPONSIBLITY OF EACH
CONTRACTOR AND SUB-CONTRACTOR
OR CONSULTANT TO CHECK AND
VERIFY ALL DIMENSIONS AND
CONDITIONS ON SITE. NOTIFY OWNER
OF ANY ERRORS OR OMISSIONS PROIR
TO COMMENCING THE WORK. DO NOT
SCALE THE DRAWINGS.
Pressed steel
acoustic door
Pressed steel frame
to match existing
ARCHITECT / ARCHITECTE
CE DESSIN CONSTITUE LA PROPRIÉTÉ
DE LA VILLE D'OTTAWA ET TOUT DROIT
D'AUTEUR EST RÉSERVÉ. LES
DIMENSIONS UTILISÉES LE SONT À DES
FINS D'ESTIMATION SEULEMENT. IL
INCOMBE À CHAQUE ENTREPRENEUR,
SOUS-CONTRACTANT OU CONSULTANT
DE VÉRIFIER TOUTES LES DIMENSIONS
ET LES CONDITIONS SUR LE CHANTIER.
VEUILLEZ INFORMER LE PROPRIÉTAIRE
DE TOUTE ERREUR OU OMISSION
AVANT D'ENTAMER LES TRAVAUX. NE
DRESSEZ PAS LES PLANS À L'ÉCHELLE.
CONSULTANT / EXPERT-CONSEIL
O
A
RID
Hardware as per
schedule
Blocking as
required
Heavy duty
hinge
ROOM SIDE
Rubber gaskets
all sides of door
Concealed acoustic
drop seal
Elevation at Door Type A
1:20
CORRIDOR
SIDE
3
ID6
CONSULTANT / EXPERT-CONSEIL
CONSULTANT / EXPERT-CONSEIL
Paint grade
hollow metal
frame
Section at Door Jamb
1:5
ROOM
INTERIOR
pressed steel
acoustic door
CORRIDOR
SIDE
45mm pressed
steel acoustic
door
2
ID6
Blocking as
required
4
ID6
Section at Door Header
1:20
PROJECT / LOCATION / PROJET / ENDROIT
High Lift Building Renovation
SCADA Work Room
1 River St. Ground Floor
OTTAWA, ONTARIO
DRAWING / DESSIN
Partition and Door Details
FACILITY NO. / NO. DE INSTALLTIONS
TBC
PROJECT NO. / PROJET NO.
11080SPTI3
SHEET NO. / FEUILLE No.
ID06