Sheet D Imperial Working Drawing Template
Transcription
Sheet D Imperial Working Drawing Template
Door Schedule Quantity Door Number Door Type U/S of existing steel pan deck 1 Existing baffle to remain. 100 A 101 1 Suspended acoustical tile ceiling. Existing Door Width/Height/Thickness Material +914mm+2134mm 45mm 532mm active leaf Aluminum door w/ glass insert +914mm+2134mm 45mm Pressed steel acoustic door Frame Hardware Set No. Notes Finish Material Finish N/A P3 Aluminum frame Hollow Metal N/A P3 N/A H1 N/A Refer to door elevation for details. INFRASTRUCTURE SERVICES & COMMUNITY SUSTAINABILITY / SERVICES D'INFRASTRUCTURE ET VIABILITÉ DES COLLECTIVITÉS INFRASTRUCTURE SERVICES BRANCH / DIRECTION D'INFRASTRUCTURE DESIGN AND CONSTRUCTION DIVISION / DIVISION DE LA CONCEPTION ET DE LA CONSTRUCTION DEPUTY CITY MANAGER / DIRECTEUR DES SERVICES MUNICIPAUX DIRECTOR / DIRECTEUR MANAGER / GESTIONNAIRE FOR / POUR CORPORATE SERVICES REAL PROPERTY ASSET MANAGEMENT DESIGN & CONSTRUCTION Acoustical Building Felt Liner. "L" trim (Typical). Building Standard Ceiling 'T' Clip. 92mm 25 gauge steel metal studs @ 410mm o.c. c/w 2 layers of 16mm gypsum board both sides. Tape, fill & sand smooth ready for paint or other finish. 211-2141 Thurston Drive Ottawa ON K1G 6C9 T 613-739-3699 F 613-739-3965 LWG-ai.com [email protected] 65mm sound attenuation batts suitable for metal stud application. Baseboard as applicable. Metal runner (Typical). Acoustical caulk. Line of finished floor as applicable. 6 5 Line of existing concrete slab. 1 ID6 4 Issued for tender 28-08-2013 MB 3 Issued for Final review 12-08-2013 MB 2 Issued for 90% review 23-07-2013 MB 1 TI- Interior Partition - Underside of T-bar Ceiling NUMBER/ NUMÉRO 1:2 26-06-2013 Issued for 60% review MILESTONE / FAIT SAILLANT DATE: DG DG MB 1:100 MB (Y/M/D) (A/M/J) INITIALS INITIALES DETAIL NUMBER 1 DRAWING TITLE A1.1 SCALE: SHEET NUMBER THIS DRAWING IS THE PROPERTY OF THE CITY OF OTTAWA AND ALL COPYRIGHT IS RESERVED. DIMENSIONS ON DRAWING ARE FOR ESTIMATING PURPOSES ONLY. IT IS THE RESPONSIBLITY OF EACH CONTRACTOR AND SUB-CONTRACTOR OR CONSULTANT TO CHECK AND VERIFY ALL DIMENSIONS AND CONDITIONS ON SITE. NOTIFY OWNER OF ANY ERRORS OR OMISSIONS PROIR TO COMMENCING THE WORK. DO NOT SCALE THE DRAWINGS. Pressed steel acoustic door Pressed steel frame to match existing ARCHITECT / ARCHITECTE CE DESSIN CONSTITUE LA PROPRIÉTÉ DE LA VILLE D'OTTAWA ET TOUT DROIT D'AUTEUR EST RÉSERVÉ. LES DIMENSIONS UTILISÉES LE SONT À DES FINS D'ESTIMATION SEULEMENT. IL INCOMBE À CHAQUE ENTREPRENEUR, SOUS-CONTRACTANT OU CONSULTANT DE VÉRIFIER TOUTES LES DIMENSIONS ET LES CONDITIONS SUR LE CHANTIER. VEUILLEZ INFORMER LE PROPRIÉTAIRE DE TOUTE ERREUR OU OMISSION AVANT D'ENTAMER LES TRAVAUX. NE DRESSEZ PAS LES PLANS À L'ÉCHELLE. CONSULTANT / EXPERT-CONSEIL O A RID Hardware as per schedule Blocking as required Heavy duty hinge ROOM SIDE Rubber gaskets all sides of door Concealed acoustic drop seal Elevation at Door Type A 1:20 CORRIDOR SIDE 3 ID6 CONSULTANT / EXPERT-CONSEIL CONSULTANT / EXPERT-CONSEIL Paint grade hollow metal frame Section at Door Jamb 1:5 ROOM INTERIOR pressed steel acoustic door CORRIDOR SIDE 45mm pressed steel acoustic door 2 ID6 Blocking as required 4 ID6 Section at Door Header 1:20 PROJECT / LOCATION / PROJET / ENDROIT High Lift Building Renovation SCADA Work Room 1 River St. Ground Floor OTTAWA, ONTARIO DRAWING / DESSIN Partition and Door Details FACILITY NO. / NO. DE INSTALLTIONS TBC PROJECT NO. / PROJET NO. 11080SPTI3 SHEET NO. / FEUILLE No. ID06