Measure of dermis density
Transcription
Measure of dermis density
Clinical study on The improvement of stretch marks with a treatment of meso-needling + LED MESO-NEEDLING AND LED INSTRUMENTAL STUDY ON STRETCH MARKS Instrumental study realized by an independant clinical research center in dermatology (GREDECO, Paris, France) on 15 subjects. Objective : To measure the improvement of stretch marks (abdomen, hips, buttocks), 1 recent and 14 old, with the association Mesoneedling NCTF 135HA + LED. Protocol: 12 sessions , 1 session per week during 12 weeks Meso-needling NCFT135HA, (1mm needles) LED : Continuous red and pulsed near IR (294Hz) in the same time during 12 minutes (8,64 Joules/cm2 for continuous red and 7,2 Joules /cm2 for pulsed NIR Evaluation at D10 and D90 after the end of the treatment Dermatologic scoring on wrinkled aspect, depth of the stretch marks Profilometric study (Skin Station®, unit: Volume/ mm2) Chromatic analysis between stretch marks and normal skin (Chromameter Konica Minolta CR/DP-400®) Standardized photography Measure of dermis density with a high-frequency ultransound Global efficiency score (0 to 10) done by the subjects. MESO-NEEDLING AND LED CLINICAL STUDY RESULTS OF AN INSTRUMENTAL STUDY ON STRETCH MARKS Dermatologic scoring on wrinkled aspect, and depth of the stretch marks Stretch marks depth Score 0 to 4 (deepest) Wrinkled aspect Score 0 to 4 (worse aspect) 2,50 3,00 - 61 % 2,50 P=0,00568 x 10 - 59 % 2,00 -5 P=0,00128 x 10 -7 2,00 1,50 1,50 2,33 2,63 1,00 1,00 1,37 0,50 1,40 1,05 0,00 D0 N=15 J0 10 jours après la fin After 8dusessions traitement N=15 3 mois après la fin D90 12 sessions du after traitement N=15 0,95 0,50 0,00 D0 J0 N=15 Jours après la D90 3 mois après fin After 810sessions after 12lasessions fin du traitement du traitement N=15 N=14 MESO-NEEDLING AND LED INSTRUMENTAL MEASURES Profilometric study (Skin Station®, unit: Volume/ mm2) Chromatic analysis between stretch marks and normal skin (Chromameter Konica Minolta CR/DP-400®) Chromatic analysis (L parameter) Profilometric study (V/mm2) between stretch marks and normal skin - 29 % 40,00 P=0,000035 - 47 % 2,50 35,00 P=0,026 2,00 30,00 25,00 1,50 37,48 20,00 29,69 15,00 26,71 1,00 2,04 1,58 10,00 1,09 0,50 5,00 0,00 0,00 D0 N=15 J0 10 jours après la fin 3 mois après la fin 8 sessions after 12 sessions du traitement D90du traitement After N=15 N=15 D0J0 N=15 après la D90 3 mois après12 la fin After108jours sessions after sessions fin du traitement du traitement N=15 N=14 MESO-NEEDLING AND LED INSTRUMENTAL MEASURES Measure of dermis density with a high-frequency ultransound Reflect of the collagen density increased Dermis density + 25 % P=0,00228 x 10 -4 80,00 70,00 60,00 50,00 75,11 40,00 30,00 65,83 58,22 20,00 10,00 0,00 J0 D0 N=15 10 jours après la fin du traitement After 8 sessions N=15 3 mois après la fin du traitement D90 after 12 sessions N=14 MESO-NEEDLING AND LED PICTURES WITH ECHOGRAPHY Visible increased of the dermis density (reflect of collagen density) DermscanC-2D USB (20 probe, 20MHz) Subject 4 D0 D90 after 12 sessions MESO-NEEDLING AND LED VISIBLE IMPROVEMENT Very good global efficiency score done by the subjects on a 0 to 10 scale: 7,47 / 10 at 10 days after the end treatment 8,07/ 10 at 90 days after the end treatment Subject 7 D0 D90 after end treatment MESO-NEEDLING AND LED VISIBLE IMPROVEMENT Subject 4 D0 D90 after end treatment Subject 6 D0 D10 after end treatment