building renovations city of ottawa forestry services ground floor plan

Transcription

building renovations city of ottawa forestry services ground floor plan
DEMOLITION GENERAL NOTES
1.
4565 (EXTENT OF NEW DRYWALL PARTITION)
1
EXISTING FURNITURE IN SCOPE OF WORK TO BE
REMOVED/REINSTATED BY GENERAL CONTRACTOR IN
CO-ORDINATION WITH OWNER. GENERAL CONTRACTOR TO
PROVIDE 7 NEW STORAGE LOCKERS (TO MATCH EXISTING
"GLOBO" OR APPROVED EQUIVALENT LOCKERS)
NEW DRYING AREA LOCKERS PROVIDED/INSTALLED BY
GENERAL CONTRACTOR
SHOP EQUIPMENT CABINETS TO BE PROVIDED BY OWNER
& INSTALLED BY GENERAL CONTRACTOR
REMOVE EXISTING LIGHTING AND MECHANICAL FIXTURES
AS REQUIRED IN SCOPE OF WORK BY GENERAL
CONTRACTOR (SEE MECHANICAL & ELECTRICAL
DRAWINGS).
ALL NEW CONCRETE BLOCK & DRYWALL INFILLS TO BE
BUILT INTO EXISTING AND SURROUNDING WALLS TO BE
PATCHED/REPAIRED TO MATCH PAINT WALL TO PROVIDE
EVEN APPEARANCE.
18
2.
800
17
4
17
3.
24
2
1000
31
6
19
16
32
4
5.
16
103
MENS LOCKER ROOM
112
STOR.
1
2
18
17
19
17
3
8
33
8
11
1015
110
6
1
5
8
4
31
23
16
17
3
27
25
DF
FOR / POUR
10
9
9
REMOVE EXISTING CONCRETE BLOCK PARTITION.
PATCH & REPAIR AS REQUIRED.
5
REMOVE EXISTING WASHROOM PARTITION
6
REMOVE EXISTING CHAIN-LINK FENCING & GATES.
PATCH & REPAIR CONCRETE SLAB-ON-GRADE.
7
REMOVE EXISTING WOODEN ENTRANCE VESTIBULE
C/W DOOR, SIDELIGHT, AND ASPHALT SHINGLE ROOF
8
REMOVE EXISTING PLUMBING FIXTURES. SAW CUT &
REMOVE EXISTING CONCRETE SLAB-ON-GRADE TO
SUIT PROPOSED NEW PLUMBING LINES & FIXTURES
(REFER TO MECHANICAL DRAWINGS)
9
EXISTING OVERHEAD GARAGE DOOR PANELS TO BE
REPAIRED/REPLACED/PAINTED (SEE ELEVATIONS).
REINSTATE DOOR PANELS WHEN WORK TO PANELS
IS COMPLETED.
10
EXISTING EXTERIOR ROOF LADDER TO BE REPAIRED &
EXTENDED FOR NEW BOTTOM LADDER EXTENSION
11
REMOVE EXISTING CONCRETE WALKWAY / PAVER
SIDEWALK
12
REMOVE EXISTING GYPSUM BOARD PARTITION TO
SUIT NEW DOOR LOCATION & HEIGHT OF MEZZANINE.
13
SAW CUT & REMOVE EXISTING EXTERIOR WALL.
PATCH, REPAIR, & PAINT INTERIOR DRYWALL AS
REQUIRED FOR NEW WINDOW.
18
UP
SAW CUT & REMOVE EXISTING CONCRETE BLOCK.
GROUT PERIMETER OPENING (REFER TO DOOR
SCHEDULE FOR DOOR DIMENSIONS). PATCH & REPAIR
CONCRETE SLAB-ON-GRADE IN AREA OF DEMOLITION
(SEE DRAWING A-301)
REMOVE EXISTING GYPSUM PARTITION
18
Jp2g Consultants Inc.
REMOVE EXISTING DOOR & FRAME
4
17
1
34
20
3
9
2
102
MEN'S W/R
8
31
22
PORTEFEUILLE DE L'URBANISME ET DE L'INFRASTRUCTURE
DÉPARTEMENT DES SERVICES D'INFRASTRUCTURE
DIRECTION DE CONCEPTION ET DE CONSTRUCTION - IMMEUBLES ET DES PARCS
DEMOLITION NOTES
6
27
7
30
6
31
UP
4.
9
PLANNING AND INFRASTRUCTURE PORTFOLIO
INFRASTRUCTURE SERVICES DEPARTMENT
DESIGN AND CONSTRUCTION - BUILDINGS & PARKS BRANCH
________________________________________________________________
ENGINEERS
.
PLANNERS
.
PROJECT MANAGERS
1150 MORRISON DRIVE, SUITE 410, OTTAWA, ON K2H 8S9
PHONE: 613-828-7800
FAX: 613-828-2600
2140123A
THE ENGINEER WAVES ANY AND ALL RESPONSIBILITY AND LIABILITY FOR PROBLEMS
WHICH ARISE FORM FAILURE TO FOLLOW THESE PLANS, SPECIFICATIONS AND THE
DESIGN INTENT THEY CONVEY, OR FOR PROBLEMS WHICH ARISE FROM OTHER FAILURE
TO OBTAIN AND/OR FOLLOW THE ENGINEER'S GUIDANCE WITH RESPECT TO ANY ERRORS,
OMISSIONS, INCONSISTENCIES, AMBIGUITIES OR CONFLICT WHICH ARE ALLEGED.
_________________________________________________________________________________
L'INGÉNIEUR DÉCLINE TOUTE RESPONSIBILITÉ DÉCOULANT DE PROBLÈMES FAISANT
SUITE AU NON RESPECT DES PLANS, DEVIS ET DE L'INTENTION DU CONCEPT QU'ILS
INDIQUENT OU DE TOUS LES PROBLÈEMES POUVANT RÉSULTER DU DÉFAUT D'OBTENIR
ET/OU DE SUIVRE LES CONSEILS DE L'INGÉNIEUR EN CE QUI CONCERNE LES ERREURS,
OMISSIONS, INCONSISTANCES, AMBIGUITÉS OU CONFLITS ALLÈGUÉS.
18
21
EXISTING DRIVEWAY
DRIVEWAY
6
5
14
1
A-101
15
GROUND FLOOR PLAN - DEMOLITION
SCALE - 1:75
16
EQ
810
EQ
13
810
17
EQ
13
SAW CUT & REMOVE EXISTING CONCRETE SLAB FOR
PLUMBING WORK
EXISTING ROOF STRUCTURE TO REMAIN. REMOVE
EXISTING METAL SIDING (REFER TO ELEVATIONS)
REMOVE EXISTING LAY-IN-TILE CEILING TILE & GRID.
CUTBACK SUSPENSION GRIDS AS REQUIRED FOR NEW
PARTITION.
SAW CUT & REMOVE EXISTING CONCRETE
SLAB-ON-GRADE (REFER TO STRUCTURAL DRAWINGS
FOR SIZING & LOCATION OF REMOVALS)
18
EXISTING DOORS TO REMAIN
19
EXISTING STORAGE LOCKERS TO BE REMOVED &
RELOCATED TO NEW MEN'S LOCKER ROOM
20 EXISTING SOD & TOP SOIL TO BE REMOVED
21
CUT ASPHALT & EXCAVATE FOR INSTALLATION OF
NEW BOLLARDS (SEE A-102 FOR LOCATIONS)
22 REMOVE EXISTING DRYWALL BULKHEAD
23 REMOVE EXISTING CERAMIC TILE FLOORING. PATCH &
4
3
2
ISSUED FOR PERMIT/TENDER
30 SEPT 2014
1
ISSUED FOR CLIENT REVIEW
18 SEPT 2014
NUMBER/
NUMÉRO
(Y/M/D)
DATE:
(A/M/J)
MILESTONE / FAIT SAILLANT
S.HAYWARD
S.HAYWARD
W.DUNK
AS NOTED
S.H.
S.H.
INITIALS
INITIALES
DETAIL NUMBER
1 DRAWING TITLE
A1.1 SCALE:
SHEET NUMBER
THIS DRAWING IS THE PROPERTY OF
THE CITY OF OTTAWA AND ALL
COPYRIGHT IS RESERVED.
DIMENSIONS ON DRAWING ARE FOR
ESTIMATING PURPOSES ONLY. IT IS
THE RESPONSIBILITY OF EACH
CONTRACTOR AND SUB-CONTRACTOR
OR CONSULTANT TO CHECK AND
VERIFY ALL DIMENSIONS AND
CONDITIONS ON SITE. NOTIFY OWNER
OF ANY ERRORS OR OMISSIONS PRIOR
TO COMMENCING THE WORK. DO NOT
SCALE THE DRAWINGS.
CE DESSIN CONSTITUE LA PROPRIÉTÉ
DE LA VILLE D'OTTAWA ET TOUT DROIT
D'AUTEUR EST RÉSERVÉ. LES
DIMENSIONS UTILISÉES LE SONT À DES
FINS D'ESTIMATION SEULEMENT. IL
INCOMBE À CHAQUE ENTREPRENEUR,
SOUS-CONTRACTANT OU CONSULTANT
DE VÉRIFIER TOUTES LES DIMENSIONS
ET LES CONDITIONS SUR LE CHANTIER.
VEUILLEZ INFORMER LE PROPRIÉTAIRE
DE TOUTE ERREUR OU OMISSION
AVANT D'ENTAMER LES TRAVAUX. NE
DRESSEZ PAS LES PLANS À L'ÉCHELLE.
REPAIR CONCRETE SLAB-ON-GRADE AS REQUIRED.
26
24 REMOVE EXISTING VCT FLOORING. PATCH & REPAIR
28
ARCHITECT / ARCHITECTE
CONSULTANT / EXPERT-CONSEIL
CONSULTANT / EXPERT-CONSEIL
CONSULTANT / EXPERT-CONSEIL
CONCRETE SLAB-ON-GRADE AS REQUIRED
DN
25 REMOVE EXISTING WASHROOM FIXTURES, INCLUDING
DISPENSERS, MIRRORS, AND WASTE RECEPTACLES.
26 EXISTING LAY-IN-TILE CEILING GRID TO REMAIN.
REMOVE & REPLACE TILE, BEFORE & AFTER
ERECTION OF NEW PARTITION.
27 REMOVE EXISTING BRICK VENEER & INSULATION IN
AREA OF PROPOSED NEW 'VESTIBULE V100'
1015
7
28 REMOVE EXISTING STANDING SEAM METAL ROOFING
& SIDING FROM EXISTING 'BUMP-OUT' OF BUILDING
15
29 PROVIDE SLAB CUTS AS SHOWN. COORDINATE WITH
MECHANICAL FOR LOCATIONS & BACKFILL. PATCH &
REPAIR CONCRETE SLAB-ON-GRADE AS REQUIRED TO
INSTALL NEW TILE FLOORING
18
12
30 REMOVE EXISTING STEEL PLATE OVER OPEN PIT
31
DN
SAW CUT & REMOVE EXISTING CONCRETE
SLAB-ON-GRADE FOR NEW PLUMBING (REFER TO
MECHANICAL DRAWINGS)
32 REMOVE EXISTING LAY-IN-TILE CEILING TILE &
RETAIN EXISTING GRID SYSTEM. CUTBACK
SUSPENSION GRIDS AS REQUIRED FOR NEW
PARTITION.
33 EXISTING CARD READER TO BE RELOCATED TO NEW
ENTRANCE LOCATION
34 EXISTING DRINKING FOUNTAIN TO REMAIN
PROJECT / LOCATION / PROJET / ENDROIT
BUILDING RENOVATIONS
CITY OF OTTAWA
FORESTRY SERVICES
125 WALGREEN RD.
OTTAWA, ONTARIO
DRAWING / DESSIN
GROUND FLOOR PLAN
SECOND FLOOR PLAN
DEMOLITION
BUSINESS ENTITY / NUMÉRO DE L'ENTITÉ
BUILDING NUMBER / NUMÉRO DU BÂTIMENT
2
A-101
SECOND FLOOR PLAN - DEMOLITION
SCALE - 1:75
PROJECT NO. / NUMÉRO DE PROJET
/ 14-54
SHEET NO. / FEUILLE No.