Motorcycle Manufacturer
Motorcycle Manufacturer Model Issue ZX9-R 02/98 – rev. 00 Recommended siting On the right side of the rear frame, under the fairing. Power supply Connect the positive and the negative supply wires of the alarm system directly to the motorcycle battery. Engine immobilisation (1) Follow Diagram B. Cut the RED/WHITE wire of the 6way connector available under the fuel tank, behind the steering post. Engine immobilisation (2) Cut the YELLOW/RED wire of the starter solenoid found behind the battery. Ignition controlled positive supply Connect to the BROWN wire of the 2-way connector available on the right of the battery. Turn indicators Connect to the GREEN and GREY wires of the rear turn indicators. Side stand Connect to the GREEN/WHITE wire available in the 2way connector coming out of the stand. The information contained herein is merely indicative and without responsibility on SPYBALL. You are strongly recommended to check for possible discrepancies or for changes made by the motorcycle manufacturer prior to connecting. COBRA AUTOMOTIVE TECHNOLOGIES SPA - SPYBALL BUSINESS UNIT - VIA ASTICO 41 – 21100 VARESE (VA) www.spyball.it [email protected]