INSTALLATION INSTRUCTIONS
lumenbeam™
drawing number 104355
MEDIUM & LARGE PENDANT
WHITE & STATIC COLORS,
COLOR CHANGING &
DYNAMIC WHITE
This product must be installed in accordance with applicable national and local electrical and construction
codes by a person familiar with the construction and operation of the product and the hazards involved.
Failure to comply with the following installation instructions may result in death or serious injury.
!
!
WARNING
!
DO NOT USE IF FIXTURE, PARTS OR CONNECTORS ARE DAMAGED.
CAUTION
WARNING
UNAUTHORIZED FIELD REPAIRS WILL VOID WARRANTY
DO NOT EXCEED FIXTURE SPECIFIED VOLTAGE.
SCAN - INSTALL STEM
SCAN - INSTALL CANOPY
!
WARNING
MAKE SURE TO
TIGHTEN SET SCREW
TO SECURE STEM
INSTALLATION
INPUT
4 X 4 JUNCTION BOX NOT INCLUDED
ANCHORING HARDWARE IS
PROVIDED BY OTHERS.
SEAL WASHER
ADD THREAD SEAL
TAPE ON THREADS
(PROVIDED BY
OTHERS)
Wiring detail - male connector
HEX KEY SIZE 1/8”
American
Color Code
CE
Color Code
USE
Green
Black
White
Red/ Purple
Orange
Yellow/Green
Brown
Blue
Black
Grey
Ground
Live 100-277V
Neutral
0-10V / Data +
0-10V / Data -
CONNECT WIRES
INSTALL CANOPY COVER
NON DIMMING
JUNCTION BOX
DIMMING / DMX/RDM
JUNCTION BOX
CANOPY MOUNTING PLATE
CANOPY MOUNTING PLATE
GROUND
green
GROUND
green
black
white
green
black
white
green
black
white
green
black
white
green
LINE
NEUTRAL
LINE
GROUND
POWER CABLE
NEUTRAL
orange
GROUND
red
DATA - DATA +
POWER & DATA CABLE
CANOPY
CANOPY
STEM
STEM
!
WARNING
DISCONNECT POWER BEFORE INSTALLING OR
SERVICING TO AVOID ELECTRICAL SHOCK.
!
WARNING
POWER CABLE SHOULD NOT SUPPORT
WEIGHT OF FIXTURE: LEAVE LOOSE
DMX/Data Cable Specification
DMX Cable from Controller to CBX and CBX to CBX shall adhere to ANSI E1.11 – 2008 (r2013) – Entertainment Technology – USITT DMX512-A, Asynchronous
Serial Digital Data Transmission Standard for Controlling Lighting Equipment and Accessories. At minimum DMX Cable shall be 1-Pair (24 AWG, 7x32
Stranding)Twisted (minimum of 4.8 twists/foot), Shielded, minimum of 100 ohms Impedance, and <25 pF/ft. Capacitance.
NOTICE
RECORD THE LOCATION OF EACH
FIXTURE BY SERIAL NUMBER TO
PREPARE FOR THE COMMISSIONING
PROCESS (DMX/RDM).
Combined Power & Data Cable Specification
Fixture cabling from CBX to Fixtures shall be installed per NEC and Local Codes. All cables shall be SOOW style cables with minimum of 16 AWG annealed
stranded bare copper per ASTM B-174 with a minimum temperature range of -40°C to +90°C. All conductor standing must be a minimum of 26/30 and capable
of handling 13 amps. Cable must be water resistant, UL Listed and CSA certified for indoor and outdoor use. Must be Ozone-sunlight (UV) and weather resistant.
ACCESSORY OPTIONS & INSTALLATION
SEAL JUNCTION BOX
NUT
SNOOT WIDE
SNOOT
RTV
s
SEAL WASHER
ilico
VISOR
! WARNING
FOR WET LOCATION INSTALLATIONS, USE
WEATHERPROOF JUNCTION BOXES AND
SEAL ALL POSSIBLE WATER ENTRY POINTS
AND COVERS USING RTV SILICONE.
(SEALING COMPOUND AND JUNCTION
BOXES BY OTHERS)
GASKET
ACCESSORY
WIRE GUARD
LINEAR SPREAD
LENS ADJUSTABLE
ne
SCREW (4X)
ACCESSORY ADJUSTMENT
FINAL VIEW
!
CAUTION
DO NOT LOOK INTO BEAM.
REMOVE SCREWS
FROM ACCESSORY
ADJUST ACCESSORY IN
90º INCREMENTS
TIGHTEN SCREWS TO
SECURE ASSEMBLY
4X
HEX KEY SIZE 2.5MM
bin™, a proprietary binning method, guarantees color temperature consistency within a 3-step MacAdam ellipse.
™
Combine lumentranslator with Lumentalk-enabled luminaires housing Lumenpulse's proprietary lumenear control card to build your Lumentalk system.
p.1/3
07/DE/2015
S.Ayite - Rev.14
Lumenpulse, 1751 Richardson, Suite 1505, Montreal (Quebec) Canada H3K 1G6 1.877.937.3003 P. 514.937.3003 F. 514.937.6289
[email protected] www.lumenpulse.com
Copyright © Lumenpulse 2015
Lumenpulse reserves the right to make changes to this product and related instructions at any time without prior notice
and such changes shall be effective immediately. See www.lumenpulse.com/support/downloads for current data and instructions.
lumenbeam™
INSTALLATION INSTRUCTIONS
drawing number 104355
GRANDE & LBX PENDANT
WHITE & STATIC COLORS,
COLOR CHANGING &
DYNAMIC WHITE
This product must be installed in accordance with applicable national and local electrical and construction
codes by a person familiar with the construction and operation of the product and the hazards involved.
Failure to comply with the following installation instructions may result in death or serious injury.
!
!
WARNING
!
DO NOT USE IF FIXTURE, PARTS OR CONNECTORS ARE DAMAGED.
CAUTION
WARNING
UNAUTHORIZED FIELD REPAIRS WILL VOID WARRANTY
DO NOT EXCEED FIXTURE SPECIFIED VOLTAGE.
SCAN - INSTALL STEM
SCAN - INSTALL CANOPY
!
WARNING
MAKE SURE TO
TIGHTEN SET SCREW
TO SECURE STEM
INSTALLATION
4 X 4 JUNCTION BOX NOT INCLUDED
ANCHORING HARDWARE IS
PROVIDED BY OTHERS.
Wiring detail - male connector
HEX KEY SIZE 2.5MM
American
Color Code
CE
Color Code
USE
Green
Black
White
Red/ Purple
Orange
Yellow/Green
Brown
Blue
Black
Grey
Ground
Live 100-277V
Neutral
0-10V / Data +
0-10V / Data -
CONNECT WIRES
INSTALL CANOPY COVER
NON DIMMING
DIMMING / DMX/RDM
JUNCTION BOX
JUNCTION BOX
CANOPY MOUNTING
PLATE
CANOPY MOUNTING
PLATE
GROUND
green
GROUND
green
black
white
green
black
white
green
black
white
green
black
white
green
LINE
POWER CABLE
LINE
GROUND
NEUTRAL
NEUTRAL
orange
GROUND
red
DATA - DATA +
POWER & DATA CABLE
CANOPY
CANOPY
STEM
STEM
!
WARNING
!
DISCONNECT POWER BEFORE INSTALLING OR
SERVICING TO AVOID ELECTRICAL SHOCK.
WARNING
POWER CABLE SHOULD NOT SUPPORT
WEIGHT OF FIXTURE: LEAVE LOOSE
DMX/Data Cable Specification
DMX Cable from Controller to CBX and CBX to CBX shall adhere to ANSI E1.11 – 2008 (r2013) – Entertainment Technology – USITT DMX512-A, Asynchronous
Serial Digital Data Transmission Standard for Controlling Lighting Equipment and Accessories. At minimum DMX Cable shall be 1-Pair (24 AWG, 7x32
Stranding)Twisted (minimum of 4.8 twists/foot), Shielded, minimum of 100 ohms Impedance, and <25 pF/ft. Capacitance.
Combined Power & Data Cable Specification
Fixture cabling from CBX to Fixtures shall be installed per NEC and Local Codes. All cables shall be SOOW style cables with minimum of 16 AWG annealed
stranded bare copper per ASTM B-174 with a minimum temperature range of -40°C to +90°C. All conductor standing must be a minimum of 26/30 and capable
of handling 13 amps. Cable must be water resistant, UL Listed and CSA certified for indoor and outdoor use. Must be Ozone-sunlight (UV) and weather resistant.
ACCESSORY OPTIONS & INSTALLATION
NOTICE
RECORD THE LOCATION OF EACH
FIXTURE BY SERIAL NUMBER TO
PREPARE FOR THE COMMISSIONING
PROCESS (DMX/RDM).
SEAL JUNCTION BOX
RTV
s
ilico
SNOOT WIDE
SNOOT
GASKET
VISOR
ACCESSORY
WIRE GUARD
ne
HOLDER
SCREW (X4)
LINEAR SPREAD
LENS ADJUSTABLE
! WARNING
FOR WET LOCATION INSTALLATIONS, USE
WEATHERPROOF JUNCTION BOXES AND
SEAL ALL POSSIBLE WATER ENTRY POINTS
AND COVERS USING RTV SILICONE.
(SEALING COMPOUND AND JUNCTION
BOXES BY OTHERS)
ACCESSORY ADJUSTMENT
FINAL VIEW
!
CAUTION
DO NOT LOOK INTO BEAM.
REMOVE SCREWS
FROM ACCESSORY
ADJUST ACCESSORY IN
90º INCREMENTS
TIGHTEN SCREWS TO
SECURE ASSEMBLY
4X
HEX KEY SIZE 2.5MM
bin™, a proprietary binning method, guarantees color temperature consistency within a 3-step MacAdam ellipse.
™
Combine lumentranslator with Lumentalk-enabled luminaires housing Lumenpulse's proprietary lumenear control card to build your Lumentalk system.
p.2/3
07/DE/2015
S.Ayite - Rev.14
Lumenpulse, 1751 Richardson, Suite 1505, Montreal (Quebec) Canada H3K 1G6 1.877.937.3003 P. 514.937.3003 F. 514.937.6289
[email protected] www.lumenpulse.com
Copyright © Lumenpulse 2015
Lumenpulse reserves the right to make changes to this product and related instructions at any time without prior notice
and such changes shall be effective immediately. See www.lumenpulse.com/support/downloads for current data and instructions.
lumenbeam™
INSTALLATION INSTRUCTIONS
drawing number 104355
!
MEDIUM, LARGE,
GRANDE & LBX PENDANT
WHITE & STATIC COLORS,
COLOR CHANGING &
DYNAMIC WHITE
This product must be installed in accordance with applicable national and local electrical and construction
codes by a person familiar with the construction and operation of the product and the hazards involved.
Failure to comply with the following installation instructions may result in death or serious injury.
WARNING
!
!
DO NOT USE IF FIXTURE, PARTS OR CONNECTORS ARE DAMAGED.
CAUTION
WARNING
UNAUTHORIZED FIELD REPAIRS WILL VOID WARRANTY
DO NOT EXCEED FIXTURE SPECIFIED VOLTAGE.
PASS/WIRES CABLE THROUGH STEM
ACAN - INSTALL STEM
NUT
SEAL WASHER
PASS THE FIXTURE’S WIRES
(CABLE FOR LBX PENDANT)
THROUGH THE STEM.
ADD THREAD SEAL TAPE
ON THREADS
(PROVIDED BY OTHERS)
INSTALL STEM ON THE FIXTURE.
PLACE CANOPY COVER OVER STEM.
WIRING DETAIL
INSTALL MOUNTING
PLATE & BALL ALIGNER ON
FIXTURE’S STEM
CONNECT WIRES
NON DIMMING
DIMMING / DMX/RDM
JUNCTION BOX
Wiring detail - male connector
American
Color Code
CE
Color Code
USE
Green
Black
White
Red/ Purple
Orange
Yellow/Green
Brown
Blue
Black
Grey
Ground
Live 100-277V
Neutral
0-10V / Data +
0-10V / Data -
JUNCTION BOX
black
white
green
black
white
green
black
white
green
black
white
green
LINE
NEUTRAL
LINE
GROUND
MOUNTING PLATE
NEUTRAL
orange
red
GROUND
MOUNTING PLATE
!
WARNING
!
DISCONNECT POWER BEFORE INSTALLING OR
SERVICING TO AVOID ELECTRICAL SHOCK.
DMX/Data Cable Specification
DMX Cable from Controller to CBX and CBX to CBX shall adhere to ANSI E1.11 – 2008 (r2013) – Entertainment Technology – USITT DMX512-A, Asynchronous
Serial Digital Data Transmission Standard for Controlling Lighting Equipment and Accessories. At minimum DMX Cable shall be 1-Pair (24 AWG, 7x32
Stranding)Twisted (minimum of 4.8 twists/foot), Shielded, minimum of 100 ohms Impedance, and <25 pF/ft. Capacitance.
Combined Power & Data Cable Specification
Fixture cabling from CBX to Fixtures shall be installed per NEC and Local Codes. All cables shall be SOOW style cables with minimum of 16 AWG annealed
stranded bare copper per ASTM B-174 with a minimum temperature range of -40°C to +90°C. All conductor standing must be a minimum of 26/30 and capable
of handling 13 amps. Cable must be water resistant, UL Listed and CSA certified for indoor and outdoor use. Must be Ozone-sunlight (UV) and weather resistant.
INSTALL FIXTURE ON JBOX
WARNING
POWER CABLE SHOULD NOT SUPPORT
WEIGHT OF FIXTURE: LEAVE LOOSE
NOTICE
RECORD THE LOCATION OF EACH
FIXTURE BY SERIAL NUMBER TO
PREPARE FOR THE COMMISSIONING
PROCESS (DMX/RDM).
SEAL JUNCTION BOX
RTV
sili
co
ne
! WARNING
FOR WET LOCATION INSTALLATIONS, USE
WEATHERPROOF JUNCTION BOXES AND
SEAL ALL POSSIBLE WATER ENTRY POINTS
AND COVERS USING RTV SILICONE.
(SEALING COMPOUND AND JUNCTION
BOXES BY OTHERS)
4 X 4 JUNCTION BOX NOT INCLUDED
ANCHORING HARDWARE IS
PROVIDED BY OTHERS.
INSTALL CANOPY COVER
FINAL VIEW
« click »
SNAP CANOPY COVER
INTO PLACE USING THE TABS ON THE
SIDE OF THE CANOPY MOUNTING PLATE.
bin™, a proprietary binning method, guarantees color temperature consistency within a 3-step MacAdam ellipse.
™
Combine lumentranslator with Lumentalk-enabled luminaires housing Lumenpulse's proprietary lumenear control card to build your Lumentalk system.
p.3/3
07/DE/2015
S.Ayite - Rev.14
Lumenpulse, 1751 Richardson, Suite 1505, Montreal (Quebec) Canada H3K 1G6 1.877.937.3003 P. 514.937.3003 F. 514.937.6289
[email protected] www.lumenpulse.com
Copyright © Lumenpulse 2015
Lumenpulse reserves the right to make changes to this product and related instructions at any time without prior notice
and such changes shall be effective immediately. See www.lumenpulse.com/support/downloads for current data and instructions.