INSTALLATION INSTRUCTIONS lumenbeam™ drawing number 104355 MEDIUM & LARGE PENDANT WHITE & STATIC COLORS, COLOR CHANGING & DYNAMIC WHITE This product must be installed in accordance with applicable national and local electrical and construction codes by a person familiar with the construction and operation of the product and the hazards involved. Failure to comply with the following installation instructions may result in death or serious injury. ! ! WARNING ! DO NOT USE IF FIXTURE, PARTS OR CONNECTORS ARE DAMAGED. CAUTION WARNING UNAUTHORIZED FIELD REPAIRS WILL VOID WARRANTY DO NOT EXCEED FIXTURE SPECIFIED VOLTAGE. SCAN - INSTALL STEM SCAN - INSTALL CANOPY ! WARNING MAKE SURE TO TIGHTEN SET SCREW TO SECURE STEM INSTALLATION INPUT 4 X 4 JUNCTION BOX NOT INCLUDED ANCHORING HARDWARE IS PROVIDED BY OTHERS. SEAL WASHER ADD THREAD SEAL TAPE ON THREADS (PROVIDED BY OTHERS) Wiring detail - male connector HEX KEY SIZE 1/8” American Color Code CE Color Code USE Green Black White Red/ Purple Orange Yellow/Green Brown Blue Black Grey Ground Live 100-277V Neutral 0-10V / Data + 0-10V / Data - CONNECT WIRES INSTALL CANOPY COVER NON DIMMING JUNCTION BOX DIMMING / DMX/RDM JUNCTION BOX CANOPY MOUNTING PLATE CANOPY MOUNTING PLATE GROUND green GROUND green black white green black white green black white green black white green LINE NEUTRAL LINE GROUND POWER CABLE NEUTRAL orange GROUND red DATA - DATA + POWER & DATA CABLE CANOPY CANOPY STEM STEM ! WARNING DISCONNECT POWER BEFORE INSTALLING OR SERVICING TO AVOID ELECTRICAL SHOCK. ! WARNING POWER CABLE SHOULD NOT SUPPORT WEIGHT OF FIXTURE: LEAVE LOOSE DMX/Data Cable Specification DMX Cable from Controller to CBX and CBX to CBX shall adhere to ANSI E1.11 – 2008 (r2013) – Entertainment Technology – USITT DMX512-A, Asynchronous Serial Digital Data Transmission Standard for Controlling Lighting Equipment and Accessories. At minimum DMX Cable shall be 1-Pair (24 AWG, 7x32 Stranding)Twisted (minimum of 4.8 twists/foot), Shielded, minimum of 100 ohms Impedance, and <25 pF/ft. Capacitance. NOTICE RECORD THE LOCATION OF EACH FIXTURE BY SERIAL NUMBER TO PREPARE FOR THE COMMISSIONING PROCESS (DMX/RDM). Combined Power & Data Cable Specification Fixture cabling from CBX to Fixtures shall be installed per NEC and Local Codes. All cables shall be SOOW style cables with minimum of 16 AWG annealed stranded bare copper per ASTM B-174 with a minimum temperature range of -40°C to +90°C. All conductor standing must be a minimum of 26/30 and capable of handling 13 amps. Cable must be water resistant, UL Listed and CSA certified for indoor and outdoor use. Must be Ozone-sunlight (UV) and weather resistant. ACCESSORY OPTIONS & INSTALLATION SEAL JUNCTION BOX NUT SNOOT WIDE SNOOT RTV s SEAL WASHER ilico VISOR ! WARNING FOR WET LOCATION INSTALLATIONS, USE WEATHERPROOF JUNCTION BOXES AND SEAL ALL POSSIBLE WATER ENTRY POINTS AND COVERS USING RTV SILICONE. (SEALING COMPOUND AND JUNCTION BOXES BY OTHERS) GASKET ACCESSORY WIRE GUARD LINEAR SPREAD LENS ADJUSTABLE ne SCREW (4X) ACCESSORY ADJUSTMENT FINAL VIEW ! CAUTION DO NOT LOOK INTO BEAM. REMOVE SCREWS FROM ACCESSORY ADJUST ACCESSORY IN 90º INCREMENTS TIGHTEN SCREWS TO SECURE ASSEMBLY 4X HEX KEY SIZE 2.5MM bin™, a proprietary binning method, guarantees color temperature consistency within a 3-step MacAdam ellipse. ™ Combine lumentranslator with Lumentalk-enabled luminaires housing Lumenpulse's proprietary lumenear control card to build your Lumentalk system. p.1/3 07/DE/2015 S.Ayite - Rev.14 Lumenpulse, 1751 Richardson, Suite 1505, Montreal (Quebec) Canada H3K 1G6 1.877.937.3003 P. 514.937.3003 F. 514.937.6289 [email protected] www.lumenpulse.com Copyright © Lumenpulse 2015 Lumenpulse reserves the right to make changes to this product and related instructions at any time without prior notice and such changes shall be effective immediately. See www.lumenpulse.com/support/downloads for current data and instructions. lumenbeam™ INSTALLATION INSTRUCTIONS drawing number 104355 GRANDE & LBX PENDANT WHITE & STATIC COLORS, COLOR CHANGING & DYNAMIC WHITE This product must be installed in accordance with applicable national and local electrical and construction codes by a person familiar with the construction and operation of the product and the hazards involved. Failure to comply with the following installation instructions may result in death or serious injury. ! ! WARNING ! DO NOT USE IF FIXTURE, PARTS OR CONNECTORS ARE DAMAGED. CAUTION WARNING UNAUTHORIZED FIELD REPAIRS WILL VOID WARRANTY DO NOT EXCEED FIXTURE SPECIFIED VOLTAGE. SCAN - INSTALL STEM SCAN - INSTALL CANOPY ! WARNING MAKE SURE TO TIGHTEN SET SCREW TO SECURE STEM INSTALLATION 4 X 4 JUNCTION BOX NOT INCLUDED ANCHORING HARDWARE IS PROVIDED BY OTHERS. Wiring detail - male connector HEX KEY SIZE 2.5MM American Color Code CE Color Code USE Green Black White Red/ Purple Orange Yellow/Green Brown Blue Black Grey Ground Live 100-277V Neutral 0-10V / Data + 0-10V / Data - CONNECT WIRES INSTALL CANOPY COVER NON DIMMING DIMMING / DMX/RDM JUNCTION BOX JUNCTION BOX CANOPY MOUNTING PLATE CANOPY MOUNTING PLATE GROUND green GROUND green black white green black white green black white green black white green LINE POWER CABLE LINE GROUND NEUTRAL NEUTRAL orange GROUND red DATA - DATA + POWER & DATA CABLE CANOPY CANOPY STEM STEM ! WARNING ! DISCONNECT POWER BEFORE INSTALLING OR SERVICING TO AVOID ELECTRICAL SHOCK. WARNING POWER CABLE SHOULD NOT SUPPORT WEIGHT OF FIXTURE: LEAVE LOOSE DMX/Data Cable Specification DMX Cable from Controller to CBX and CBX to CBX shall adhere to ANSI E1.11 – 2008 (r2013) – Entertainment Technology – USITT DMX512-A, Asynchronous Serial Digital Data Transmission Standard for Controlling Lighting Equipment and Accessories. At minimum DMX Cable shall be 1-Pair (24 AWG, 7x32 Stranding)Twisted (minimum of 4.8 twists/foot), Shielded, minimum of 100 ohms Impedance, and <25 pF/ft. Capacitance. Combined Power & Data Cable Specification Fixture cabling from CBX to Fixtures shall be installed per NEC and Local Codes. All cables shall be SOOW style cables with minimum of 16 AWG annealed stranded bare copper per ASTM B-174 with a minimum temperature range of -40°C to +90°C. All conductor standing must be a minimum of 26/30 and capable of handling 13 amps. Cable must be water resistant, UL Listed and CSA certified for indoor and outdoor use. Must be Ozone-sunlight (UV) and weather resistant. ACCESSORY OPTIONS & INSTALLATION NOTICE RECORD THE LOCATION OF EACH FIXTURE BY SERIAL NUMBER TO PREPARE FOR THE COMMISSIONING PROCESS (DMX/RDM). SEAL JUNCTION BOX RTV s ilico SNOOT WIDE SNOOT GASKET VISOR ACCESSORY WIRE GUARD ne HOLDER SCREW (X4) LINEAR SPREAD LENS ADJUSTABLE ! WARNING FOR WET LOCATION INSTALLATIONS, USE WEATHERPROOF JUNCTION BOXES AND SEAL ALL POSSIBLE WATER ENTRY POINTS AND COVERS USING RTV SILICONE. (SEALING COMPOUND AND JUNCTION BOXES BY OTHERS) ACCESSORY ADJUSTMENT FINAL VIEW ! CAUTION DO NOT LOOK INTO BEAM. REMOVE SCREWS FROM ACCESSORY ADJUST ACCESSORY IN 90º INCREMENTS TIGHTEN SCREWS TO SECURE ASSEMBLY 4X HEX KEY SIZE 2.5MM bin™, a proprietary binning method, guarantees color temperature consistency within a 3-step MacAdam ellipse. ™ Combine lumentranslator with Lumentalk-enabled luminaires housing Lumenpulse's proprietary lumenear control card to build your Lumentalk system. p.2/3 07/DE/2015 S.Ayite - Rev.14 Lumenpulse, 1751 Richardson, Suite 1505, Montreal (Quebec) Canada H3K 1G6 1.877.937.3003 P. 514.937.3003 F. 514.937.6289 [email protected] www.lumenpulse.com Copyright © Lumenpulse 2015 Lumenpulse reserves the right to make changes to this product and related instructions at any time without prior notice and such changes shall be effective immediately. See www.lumenpulse.com/support/downloads for current data and instructions. lumenbeam™ INSTALLATION INSTRUCTIONS drawing number 104355 ! MEDIUM, LARGE, GRANDE & LBX PENDANT WHITE & STATIC COLORS, COLOR CHANGING & DYNAMIC WHITE This product must be installed in accordance with applicable national and local electrical and construction codes by a person familiar with the construction and operation of the product and the hazards involved. Failure to comply with the following installation instructions may result in death or serious injury. WARNING ! ! DO NOT USE IF FIXTURE, PARTS OR CONNECTORS ARE DAMAGED. CAUTION WARNING UNAUTHORIZED FIELD REPAIRS WILL VOID WARRANTY DO NOT EXCEED FIXTURE SPECIFIED VOLTAGE. PASS/WIRES CABLE THROUGH STEM ACAN - INSTALL STEM NUT SEAL WASHER PASS THE FIXTURE’S WIRES (CABLE FOR LBX PENDANT) THROUGH THE STEM. ADD THREAD SEAL TAPE ON THREADS (PROVIDED BY OTHERS) INSTALL STEM ON THE FIXTURE. PLACE CANOPY COVER OVER STEM. WIRING DETAIL INSTALL MOUNTING PLATE & BALL ALIGNER ON FIXTURE’S STEM CONNECT WIRES NON DIMMING DIMMING / DMX/RDM JUNCTION BOX Wiring detail - male connector American Color Code CE Color Code USE Green Black White Red/ Purple Orange Yellow/Green Brown Blue Black Grey Ground Live 100-277V Neutral 0-10V / Data + 0-10V / Data - JUNCTION BOX black white green black white green black white green black white green LINE NEUTRAL LINE GROUND MOUNTING PLATE NEUTRAL orange red GROUND MOUNTING PLATE ! WARNING ! DISCONNECT POWER BEFORE INSTALLING OR SERVICING TO AVOID ELECTRICAL SHOCK. DMX/Data Cable Specification DMX Cable from Controller to CBX and CBX to CBX shall adhere to ANSI E1.11 – 2008 (r2013) – Entertainment Technology – USITT DMX512-A, Asynchronous Serial Digital Data Transmission Standard for Controlling Lighting Equipment and Accessories. At minimum DMX Cable shall be 1-Pair (24 AWG, 7x32 Stranding)Twisted (minimum of 4.8 twists/foot), Shielded, minimum of 100 ohms Impedance, and <25 pF/ft. Capacitance. Combined Power & Data Cable Specification Fixture cabling from CBX to Fixtures shall be installed per NEC and Local Codes. All cables shall be SOOW style cables with minimum of 16 AWG annealed stranded bare copper per ASTM B-174 with a minimum temperature range of -40°C to +90°C. All conductor standing must be a minimum of 26/30 and capable of handling 13 amps. Cable must be water resistant, UL Listed and CSA certified for indoor and outdoor use. Must be Ozone-sunlight (UV) and weather resistant. INSTALL FIXTURE ON JBOX WARNING POWER CABLE SHOULD NOT SUPPORT WEIGHT OF FIXTURE: LEAVE LOOSE NOTICE RECORD THE LOCATION OF EACH FIXTURE BY SERIAL NUMBER TO PREPARE FOR THE COMMISSIONING PROCESS (DMX/RDM). SEAL JUNCTION BOX RTV sili co ne ! WARNING FOR WET LOCATION INSTALLATIONS, USE WEATHERPROOF JUNCTION BOXES AND SEAL ALL POSSIBLE WATER ENTRY POINTS AND COVERS USING RTV SILICONE. (SEALING COMPOUND AND JUNCTION BOXES BY OTHERS) 4 X 4 JUNCTION BOX NOT INCLUDED ANCHORING HARDWARE IS PROVIDED BY OTHERS. INSTALL CANOPY COVER FINAL VIEW « click » SNAP CANOPY COVER INTO PLACE USING THE TABS ON THE SIDE OF THE CANOPY MOUNTING PLATE. bin™, a proprietary binning method, guarantees color temperature consistency within a 3-step MacAdam ellipse. ™ Combine lumentranslator with Lumentalk-enabled luminaires housing Lumenpulse's proprietary lumenear control card to build your Lumentalk system. p.3/3 07/DE/2015 S.Ayite - Rev.14 Lumenpulse, 1751 Richardson, Suite 1505, Montreal (Quebec) Canada H3K 1G6 1.877.937.3003 P. 514.937.3003 F. 514.937.6289 [email protected] www.lumenpulse.com Copyright © Lumenpulse 2015 Lumenpulse reserves the right to make changes to this product and related instructions at any time without prior notice and such changes shall be effective immediately. See www.lumenpulse.com/support/downloads for current data and instructions.