Installation Instructions PDF

Transcription

Installation Instructions PDF
lumendome™
INSTALLATION INSTRUCTIONS
drawing number 111490
!
NANO, SMALL & MEDIUM
WHITE, COLOR CHANGING
CANOPY COVER MOUNTING
This product must be installed in accordance with applicable national and local electrical and construction
codes by a person familiar with the construction and operation of the product and the hazards involved.
Failure to comply with the following installation instructions may result in death or serious injury.
WARNING
!
!
DO NOT USE IF FIXTURE, PARTS OR CONNECTORS ARE DAMAGED.
CAUTION
WARNING
DO NOT EXCEED FIXTURE SPECIFIED VOLTAGE.
UNAUTHORIZED FIELD REPAIRS WILL VOID WARRANTY
WATERTIGHT JUNCTION BOX WIRING DETAIL
!
WARNING
DISCONNECT POWER BEFORE INSTALLING OR
SERVICING TO AVOID ELECTRICAL SHOCK.
NON-DIMMING
DMX/RDM
To
Fixture
To
Fixture
Wiring detail - lumendome cord
WHITE
GREEN
BLACK
ORANGE
RED
From
PSX60,
PSX100
or previous
fixture
POWER - 48V
GROUND
POWER + 48V
DATA DATA +
CE Color Code
To next
fixture(s)
Junction box
(by others)
WIRE COLOR /
USE
BLUE
YELLOW/GREEN
BROWN
GREY
BLACK
POWER - 48V
GROUND
POWER + 48V
DATA DATA +
lumenterminator
(use at the end
of each run only)
DataData+
!
Always tie both data
wires together
American Color Code
WIRE COLOR / USE
LUMENTERMINATOR
LAST JBOX ON DMX/RDM RUN
Ground green
48V - white
48V+ black
Data Data+
From
CBX60,
CBX100
or previous
fixture
To next
fixture(s)
Junction box
(by others)
From
CBX60,
CBX100
or previous
fixture
Ground green
48V - white
48V+ black
48V+ black
Ground green
48V - white
DMX terminator is required at the end
of each run to maintain data integrity.
Lumenterminator included:
(6x) per CBX.
LOOSEN SET SCREW TO REMOVE
LUMENDOME FROM CANOPY BASE
1X
HEX KEY SIZE: 5/64”
INSTALL LUMENDOME ON JBOX
STRAIN RELIEF
BY OTHERS
CONNECT WIRES AND
INSTALL CANOPY COVER
SEAL JUNCTION BOX
AS INSTALLED
RTV
s
ilico
ne
INSTALL LUMENDOME ON TENON.
SECURE INSTALLATION OF
LUMENDOME WITH SET SCREW.
1X
HEX KEY SIZE: 5/64”
! WARNING
FOR WET LOCATION INSTALLATIONS, USE
WEATHERPROOF JUNCTION BOXES AND
SEAL ALL POSSIBLE WATER ENTRY POINTS
AND COVERS USING RTV SILICONE.
(SEALING COMPOUND AND JUNCTION
BOXES BY OTHERS)
DMX/Data Cable Specification
DMX Cable from Controller to CBX and CBX to CBX shall adhere to ANSI E1.11 – 2008 (r2013) – Entertainment Technology – USITT DMX512-A, Asynchronous
Serial Digital Data Transmission Standard for Controlling Lighting Equipment and Accessories. At minimum DMX Cable shall be 1-Pair (24 AWG, 7x32
Stranding)Twisted (minimum of 4.8 twists/foot), Shielded, minimum of 100 ohms Impedance, and <25 pF/ft. Capacitance.
Combined Power & Data Cable Specification
Fixture cabling from CBX to Fixtures shall be installed per NEC and Local Codes. All cables shall be SOOW style cables with minimum of 16 AWG annealed
stranded bare copper per ASTM B-174 with a minimum temperature range of -40°C to +90°C. All conductor standing must be a minimum of 26/30 and capable
of handling 13 amps. Cable must be water resistant, UL Listed and CSA certified for indoor and outdoor use. Must be Ozone-sunlight (UV) and weather resistant.
NOTICE
RECORD THE LOCATION OF EACH
FIXTURE BY SERIAL NUMBER TO
PREPARE FOR THE COMMISSIONING
PROCESS (DMX/RDM).
LUMENDOME FAMILY - CANOPY COVER MOUNTING OPTION
LUMENDOME NANO
DOME LENS
LUMENDOME NANO
FLAT LENS OPTION
LUMENDOME SMALL
DOME LENS
LUMENDOME SMALL
FLAT LENS OPTION
LUMENDOME MEDIUM
DOME LENS
bin™, a proprietary binning method, guarantees color temperature consistency within a 3-step MacAdam ellipse.
p.1/2
07/DE/2015
S.Ayite - Rev.5
Lumenpulse, 1751 Richardson, Suite 1505, Montreal (Quebec) Canada H3K 1G6 1.877.937.3003 P. 514.937.3003 F. 514.937.6289
[email protected] www.lumenpulse.com
Copyright © 2015 Lumenpulse
Lumenpulse reserves the right to make changes to this product and related instructions at any time without prior notice
and such changes shall be effective immediately. See www.lumenpulse.com/support/downloads for current data and instructions.
LUMENDOME MEDIUM
FLAT LENS OPTION
lumendome™
INSTALLATION INSTRUCTIONS
drawing number 111490
NANO, SMALL & MEDIUM
WHITE, COLOR CHANGING
WALL MOUNT
This product must be installed in accordance with applicable national and local electrical and construction
codes by a person familiar with the construction and operation of the product and the hazards involved.
Failure to comply with the following installation instructions may result in death or serious injury.
!
WARNING
!
!
DO NOT USE IF FIXTURE, PARTS OR CONNECTORS ARE DAMAGED.
CAUTION
WARNING
UNAUTHORIZED FIELD REPAIRS WILL VOID WARRANTY
DO NOT EXCEED FIXTURE SPECIFIED VOLTAGE.
INSTALL WALL MOUNTING BASE TO THE MOUNTING SURFACE
FIX LUMENDOME ONTO BASE
5
16 "
[8mm]
2"
[51mm]
!
SILICONE SEALING
GASKET
(INCLUDED)
WARNING
USE FASTENERS (2X BY OTHERS)
THAT ARE APPROPRIATE FOR USE WITH
YOUR MOUNTING SURFACE
TIGHTEN SET SCREW
TO LOCK THE POSITION
OF THE LUMENDOME
Wall Mount Option
Screw Hole Pattern
(hardware by others)
1X
HEX KEY SIZE: 5/64"
WATERTIGHT JUNCTION BOX WIRING DETAIL
!
WARNING
DISCONNECT POWER BEFORE INSTALLING OR
SERVICING TO AVOID ELECTRICAL SHOCK.
Wiring detail - lumendome cord
NON-DIMMING
DMX/RDM
To
Fixture
To
Fixture
lumenterminator
(use at the end
of each run only)
!
American Color Code
Always tie both data
wires together
WIRE COLOR / USE
WHITE
GREEN
BLACK
ORANGE
RED
LUMENTERMINATOR
LAST JBOX ON DMX/RDM RUN
POWER - 48V
GROUND
POWER + 48V
DATA DATA +
From
PSX60,
PSX100
or previous
fixture
CE Color Code
To next
fixture(s)
Junction box
(by others)
WIRE COLOR /
USE
BLUE
YELLOW/GREEN
BROWN
GREY
BLACK
POWER - 48V
GROUND
POWER + 48V
DATA DATA +
Ground green
48V - white
48V+ black
From
CBX60,
CBX100
or previous
fixture
Data Data+
To next
fixture(s)
Ground green
48V - white
Junction box 48V+ black
(by others)
Data Data+
From
CBX60,
CBX100
or previous
fixture
48V+ black
Ground green
48V - white
DMX terminator is required at the end
of each run to maintain data integrity.
Lumenterminator included:
(6x) per CBX.
SEAL JUNCTION BOX
AS INSTALLED
LIQUID TIGHT
STRAIN RELIEF
(BY OTHERS)
RT
V
sil
! WARNING
FOR WET LOCATION INSTALLATIONS, USE
WEATHERPROOF JUNCTION BOXES AND
SEAL ALL POSSIBLE WATER ENTRY POINTS
AND COVERS USING RTV SILICONE.
(SEALING COMPOUND AND JUNCTION
BOXES BY OTHERS)
ico
ne
DMX/Data Cable Specification
DMX Cable from Controller to CBX and CBX to CBX shall adhere to ANSI E1.11 – 2008 (r2013) – Entertainment Technology – USITT DMX512-A, Asynchronous
Serial Digital Data Transmission Standard for Controlling Lighting Equipment and Accessories. At minimum DMX Cable shall be 1-Pair (24 AWG, 7x32
Stranding)Twisted (minimum of 4.8 twists/foot), Shielded, minimum of 100 ohms Impedance, and <25 pF/ft. Capacitance.
Combined Power & Data Cable Specification
Fixture cabling from CBX to Fixtures shall be installed per NEC and Local Codes. All cables shall be SOOW style cables with minimum of 16 AWG annealed
stranded bare copper per ASTM B-174 with a minimum temperature range of -40°C to +90°C. All conductor standing must be a minimum of 26/30 and capable
of handling 13 amps. Cable must be water resistant, UL Listed and CSA certified for indoor and outdoor use. Must be Ozone-sunlight (UV) and weather resistant.
NOTICE
RECORD THE LOCATION OF EACH
FIXTURE BY SERIAL NUMBER TO
PREPARE FOR THE COMMISSIONING
PROCESS (DMX/RDM).
LUMENDOME FAMILY - WALL MOUNT OPTION
LUMENDOME NANO
DOME LENS
LUMENDOME NANO
FLAT LENS OPTION
LUMENDOME SMALL
DOME LENS
LUMENDOME SMALL
FLAT LENS OPTION
LUMENDOME MEDIUM
DOME LENS
bin™, a proprietary binning method, guarantees color temperature consistency within a 3-step MacAdam ellipse.
p.2/2
07/DE/2015
S.Ayite - Rev.5
Lumenpulse, 1751 Richardson, Suite 1505, Montreal (Quebec) Canada H3K 1G6 1.877.937.3003 P. 514.937.3003 F. 514.937.6289
[email protected] www.lumenpulse.com
Copyright © 2015 Lumenpulse
Lumenpulse reserves the right to make changes to this product and related instructions at any time without prior notice
and such changes shall be effective immediately. See www.lumenpulse.com/support/downloads for current data and instructions.
LUMENDOME MEDIUM
FLAT LENS OPTION

Documents pareils