Installation Instructions PDF
Transcription
Installation Instructions PDF
lumendome™ INSTALLATION INSTRUCTIONS drawing number 111490 ! NANO, SMALL & MEDIUM WHITE, COLOR CHANGING CANOPY COVER MOUNTING This product must be installed in accordance with applicable national and local electrical and construction codes by a person familiar with the construction and operation of the product and the hazards involved. Failure to comply with the following installation instructions may result in death or serious injury. WARNING ! ! DO NOT USE IF FIXTURE, PARTS OR CONNECTORS ARE DAMAGED. CAUTION WARNING DO NOT EXCEED FIXTURE SPECIFIED VOLTAGE. UNAUTHORIZED FIELD REPAIRS WILL VOID WARRANTY WATERTIGHT JUNCTION BOX WIRING DETAIL ! WARNING DISCONNECT POWER BEFORE INSTALLING OR SERVICING TO AVOID ELECTRICAL SHOCK. NON-DIMMING DMX/RDM To Fixture To Fixture Wiring detail - lumendome cord WHITE GREEN BLACK ORANGE RED From PSX60, PSX100 or previous fixture POWER - 48V GROUND POWER + 48V DATA DATA + CE Color Code To next fixture(s) Junction box (by others) WIRE COLOR / USE BLUE YELLOW/GREEN BROWN GREY BLACK POWER - 48V GROUND POWER + 48V DATA DATA + lumenterminator (use at the end of each run only) DataData+ ! Always tie both data wires together American Color Code WIRE COLOR / USE LUMENTERMINATOR LAST JBOX ON DMX/RDM RUN Ground green 48V - white 48V+ black Data Data+ From CBX60, CBX100 or previous fixture To next fixture(s) Junction box (by others) From CBX60, CBX100 or previous fixture Ground green 48V - white 48V+ black 48V+ black Ground green 48V - white DMX terminator is required at the end of each run to maintain data integrity. Lumenterminator included: (6x) per CBX. LOOSEN SET SCREW TO REMOVE LUMENDOME FROM CANOPY BASE 1X HEX KEY SIZE: 5/64” INSTALL LUMENDOME ON JBOX STRAIN RELIEF BY OTHERS CONNECT WIRES AND INSTALL CANOPY COVER SEAL JUNCTION BOX AS INSTALLED RTV s ilico ne INSTALL LUMENDOME ON TENON. SECURE INSTALLATION OF LUMENDOME WITH SET SCREW. 1X HEX KEY SIZE: 5/64” ! WARNING FOR WET LOCATION INSTALLATIONS, USE WEATHERPROOF JUNCTION BOXES AND SEAL ALL POSSIBLE WATER ENTRY POINTS AND COVERS USING RTV SILICONE. (SEALING COMPOUND AND JUNCTION BOXES BY OTHERS) DMX/Data Cable Specification DMX Cable from Controller to CBX and CBX to CBX shall adhere to ANSI E1.11 – 2008 (r2013) – Entertainment Technology – USITT DMX512-A, Asynchronous Serial Digital Data Transmission Standard for Controlling Lighting Equipment and Accessories. At minimum DMX Cable shall be 1-Pair (24 AWG, 7x32 Stranding)Twisted (minimum of 4.8 twists/foot), Shielded, minimum of 100 ohms Impedance, and <25 pF/ft. Capacitance. Combined Power & Data Cable Specification Fixture cabling from CBX to Fixtures shall be installed per NEC and Local Codes. All cables shall be SOOW style cables with minimum of 16 AWG annealed stranded bare copper per ASTM B-174 with a minimum temperature range of -40°C to +90°C. All conductor standing must be a minimum of 26/30 and capable of handling 13 amps. Cable must be water resistant, UL Listed and CSA certified for indoor and outdoor use. Must be Ozone-sunlight (UV) and weather resistant. NOTICE RECORD THE LOCATION OF EACH FIXTURE BY SERIAL NUMBER TO PREPARE FOR THE COMMISSIONING PROCESS (DMX/RDM). LUMENDOME FAMILY - CANOPY COVER MOUNTING OPTION LUMENDOME NANO DOME LENS LUMENDOME NANO FLAT LENS OPTION LUMENDOME SMALL DOME LENS LUMENDOME SMALL FLAT LENS OPTION LUMENDOME MEDIUM DOME LENS bin™, a proprietary binning method, guarantees color temperature consistency within a 3-step MacAdam ellipse. p.1/2 07/DE/2015 S.Ayite - Rev.5 Lumenpulse, 1751 Richardson, Suite 1505, Montreal (Quebec) Canada H3K 1G6 1.877.937.3003 P. 514.937.3003 F. 514.937.6289 [email protected] www.lumenpulse.com Copyright © 2015 Lumenpulse Lumenpulse reserves the right to make changes to this product and related instructions at any time without prior notice and such changes shall be effective immediately. See www.lumenpulse.com/support/downloads for current data and instructions. LUMENDOME MEDIUM FLAT LENS OPTION lumendome™ INSTALLATION INSTRUCTIONS drawing number 111490 NANO, SMALL & MEDIUM WHITE, COLOR CHANGING WALL MOUNT This product must be installed in accordance with applicable national and local electrical and construction codes by a person familiar with the construction and operation of the product and the hazards involved. Failure to comply with the following installation instructions may result in death or serious injury. ! WARNING ! ! DO NOT USE IF FIXTURE, PARTS OR CONNECTORS ARE DAMAGED. CAUTION WARNING UNAUTHORIZED FIELD REPAIRS WILL VOID WARRANTY DO NOT EXCEED FIXTURE SPECIFIED VOLTAGE. INSTALL WALL MOUNTING BASE TO THE MOUNTING SURFACE FIX LUMENDOME ONTO BASE 5 16 " [8mm] 2" [51mm] ! SILICONE SEALING GASKET (INCLUDED) WARNING USE FASTENERS (2X BY OTHERS) THAT ARE APPROPRIATE FOR USE WITH YOUR MOUNTING SURFACE TIGHTEN SET SCREW TO LOCK THE POSITION OF THE LUMENDOME Wall Mount Option Screw Hole Pattern (hardware by others) 1X HEX KEY SIZE: 5/64" WATERTIGHT JUNCTION BOX WIRING DETAIL ! WARNING DISCONNECT POWER BEFORE INSTALLING OR SERVICING TO AVOID ELECTRICAL SHOCK. Wiring detail - lumendome cord NON-DIMMING DMX/RDM To Fixture To Fixture lumenterminator (use at the end of each run only) ! American Color Code Always tie both data wires together WIRE COLOR / USE WHITE GREEN BLACK ORANGE RED LUMENTERMINATOR LAST JBOX ON DMX/RDM RUN POWER - 48V GROUND POWER + 48V DATA DATA + From PSX60, PSX100 or previous fixture CE Color Code To next fixture(s) Junction box (by others) WIRE COLOR / USE BLUE YELLOW/GREEN BROWN GREY BLACK POWER - 48V GROUND POWER + 48V DATA DATA + Ground green 48V - white 48V+ black From CBX60, CBX100 or previous fixture Data Data+ To next fixture(s) Ground green 48V - white Junction box 48V+ black (by others) Data Data+ From CBX60, CBX100 or previous fixture 48V+ black Ground green 48V - white DMX terminator is required at the end of each run to maintain data integrity. Lumenterminator included: (6x) per CBX. SEAL JUNCTION BOX AS INSTALLED LIQUID TIGHT STRAIN RELIEF (BY OTHERS) RT V sil ! WARNING FOR WET LOCATION INSTALLATIONS, USE WEATHERPROOF JUNCTION BOXES AND SEAL ALL POSSIBLE WATER ENTRY POINTS AND COVERS USING RTV SILICONE. (SEALING COMPOUND AND JUNCTION BOXES BY OTHERS) ico ne DMX/Data Cable Specification DMX Cable from Controller to CBX and CBX to CBX shall adhere to ANSI E1.11 – 2008 (r2013) – Entertainment Technology – USITT DMX512-A, Asynchronous Serial Digital Data Transmission Standard for Controlling Lighting Equipment and Accessories. At minimum DMX Cable shall be 1-Pair (24 AWG, 7x32 Stranding)Twisted (minimum of 4.8 twists/foot), Shielded, minimum of 100 ohms Impedance, and <25 pF/ft. Capacitance. Combined Power & Data Cable Specification Fixture cabling from CBX to Fixtures shall be installed per NEC and Local Codes. All cables shall be SOOW style cables with minimum of 16 AWG annealed stranded bare copper per ASTM B-174 with a minimum temperature range of -40°C to +90°C. All conductor standing must be a minimum of 26/30 and capable of handling 13 amps. Cable must be water resistant, UL Listed and CSA certified for indoor and outdoor use. Must be Ozone-sunlight (UV) and weather resistant. NOTICE RECORD THE LOCATION OF EACH FIXTURE BY SERIAL NUMBER TO PREPARE FOR THE COMMISSIONING PROCESS (DMX/RDM). LUMENDOME FAMILY - WALL MOUNT OPTION LUMENDOME NANO DOME LENS LUMENDOME NANO FLAT LENS OPTION LUMENDOME SMALL DOME LENS LUMENDOME SMALL FLAT LENS OPTION LUMENDOME MEDIUM DOME LENS bin™, a proprietary binning method, guarantees color temperature consistency within a 3-step MacAdam ellipse. p.2/2 07/DE/2015 S.Ayite - Rev.5 Lumenpulse, 1751 Richardson, Suite 1505, Montreal (Quebec) Canada H3K 1G6 1.877.937.3003 P. 514.937.3003 F. 514.937.6289 [email protected] www.lumenpulse.com Copyright © 2015 Lumenpulse Lumenpulse reserves the right to make changes to this product and related instructions at any time without prior notice and such changes shall be effective immediately. See www.lumenpulse.com/support/downloads for current data and instructions. LUMENDOME MEDIUM FLAT LENS OPTION