Installation Instructions PDF

Transcription

Installation Instructions PDF
lumenline™2
INSTALLATION INSTRUCTIONS
drawing number 109781
!
!
WARNING
!
SEPARATION OF FIELD INSTALLED POWER
LIMITED CIRCUIT (DIMMING/CONTROL)
WIRING FROM THE BRANCH CIRCUIT WIRING
IN THE OUTLET BOX ARE TO BE MADE IN
ACCORDANCE WITH LOCAL AND/OR
NATIONAL ELECTRICAL INSTALLATION CODES.
INSTALLATION HARDWARE
WARNING
!
DO NOT PRE-INSTALL FULL FIXTURE RUN
OR COMPLETE SHAPE ON THE FLOOR.
!
WARNING
!
WARNING
DO NOT USE IF FIXTURE, PARTS OR
CONNECTORS ARE DAMAGED.
INSTALL ALL MOUNTING HARDWARE
ACCORDING TO MANUFACTURER
MOUNTING GUIDE.
CAUTION
WARNING
DO NOT EXCEED FIXTURE SPECIFIED VOLTAGE.
UNAUTHORIZED FIELD REPAIRS WILL VOID WARRANTY.
WIRING DETAIL
NON-DIMMING OR LUMENTALK
CANOPY CABLE
COUPLER WITH
AIRCRAFT CABLE
STANDARD
BRACKET BAR WITH
1/4''-20 STUD AND
GROUND SCREW
OR
PENDANT
INDIRECT LIGHTING
This product must be installed in accordance with applicable national and local electrical and construction
codes by a person familiar with the construction and operation of the product and the hazards involved.
Failure to comply with the following installation instructions may result in death or serious injury.
0-10V, DALI OR ECOSYSTEM®
From Dimmer or Controller
To next fixture
Neutral white
Ground green
Line black
100-347V*
Input
Line black
Ground green
Neutral white
STRAIN RELIEF OR
BUSHING FOR
CANOPY
Junction box
(by others)
Data+ red/purple
Data- orange
Canopy
LENS REMOVER
TOOL
DMX/RDM
To fixture
Ø5'' FEEDER
CANOPY POWER
AND DATA WITH
HOLE PLUG
Ø2'' NON-FEEDER
CANOPY
Junction box
(by others)
Canopy
CABLE TIE (1 PER
12'' OF CABLE)
Line black
Ground green
Neutral white
From CBX
100-347V*
& Data input
!
100-347V*
& Data output
To next fixture
100-347V*
Input
100-347V*
To next fixture
WARNING
DISCONNECT POWER BEFORE
INSTALLING OR SERVICING TO
AVOID ELECTRICAL SHOCK.
To fixture
Wiring detail
Data+ red/purple
Data- orange
Junction box
(by others)
Canopy
*Lumentalk and RGB options not available with 347V.
To fixture
WIRE COLOR / USE
GREEN
WHITE
BLACK
RED/ PURPLE
ORANGE
GROUND
NEUTRAL
LINE 100-347V
DATA +
DATA -
DMX/Data Cable Specification
DMX Cable from Controller to CBX and CBX to CBX shall adhere to ANSI E1.11 – 2008 (r2013) – Entertainment Technology – USITT DMX512-A, Asynchronous Serial Digital Data Transmission Standard for
Controlling Lighting Equipment and Accessories. At minimum DMX Cable shall be 1-Pair (24 AWG, 7x32 Stranding)Twisted (minimum of 4.8 twists/foot), Shielded, minimum of 100 ohms Impedance, and <25
pF/ft. Capacitance.
Combined Power & Data Cable Specification
Fixture cabling from CBX to Fixtures shall be installed per NEC and Local Codes. All conductors shall be of the same size and minimum of 16 AWG annealed stranded bare copper per ASTM B-174 and must be a
minimum of 26/30 and capable of handling 8 amps.
OPTICS GUIDELINES
INDIRECT LIGHTING - BATWING WIDE
INDIRECT LIGHTING - WIDE FLOOD
SYMMETRICAL DISTRIBUTION, NO SPECIFIC ORIENTATION REQUIRED.
SYMMETRICAL DISTRIBUTION, NO SPECIFIC ORIENTATION REQUIRED.
FOR SINGLE UNITS:
CONTINUE INSTALLATION ACCORDING TO STEPS 1-6.
FOR SINGLE UNITS:
CONTINUE INSTALLATION ACCORDING TO STEPS 1-6.
FOR CONTINUOUS RUNS:
CONTINUE INSTALLATION ACCORDING TO STEPS 7-19.
FOR CONTINUOUS RUNS:
CONTINUE INSTALLATION ACCORDING TO STEPS 7-19.
bin™, a proprietary binning method, guarantees color temperature consistency within a 3-step MacAdam ellipse.
™
Combine lumentranslator with Lumentalk-enabled luminaires housing Lumenpulse's proprietary lumenear control card to build your Lumentalk system.
p.1/3
2016.07.28
EM - R10
Lumenpulse, 1751 Richardson, Suite 1505, Montreal (Quebec) Canada H3K 1G6 1.877.937.3003 P. 514.937.3003 F. 514.937.6289
[email protected] www.lumenpulse.com
Copyright © Lumenpulse 2016
Confidential and proprietary
Lumenpulse reserves the right to make changes to this product and related instructions at any time without prior notice
and such changes shall be effective immediately. See www.lumenpulse.com/support/downloads for current data and instructions.
lumenline™2
INSTALLATION INSTRUCTIONS
drawing number 109781
!
PENDANT
INDIRECT LIGHTING
This product must be installed in accordance with applicable national and local electrical and construction
codes by a person familiar with the construction and operation of the product and the hazards involved.
Failure to comply with the following installation instructions may result in death or serious injury.
SINGLE UNITS
STEP 1. PREPARE CANOPIES AND AIRCRAFT CABLE
!
WARNING
USE THREADED STUDS
1/4" - 20 (BY OTHERS)
THAT ARE APPROPRIATE
FOR USE WITH YOUR
MOUNTING SURFACE.
BALL
TERMINAL
BALL
TERMINAL
NOTICE
REFER TO THE
OPTICS GUIDELINES
ON PAGE 1
BEFORE INSTALLING
THE FIRST FIXTURE.
INSTALL BRACKET BAR TO
JUNCTION BOX.
SCREW COUPLER
ON BRACKET BAR.
INSTALL ALL NON-FEEDER
CANOPIES.
SEPARATE FEEDER CANOPY
COUPLER. FEED AIRCRAFT
CABLE THROUGH CANOPY
AND COUPLER.
LEAVE CANOPY
HANGING.
KEEP BALL TERMINAL ON
HIGH END OF THE CABLE.
STEP 3. ADJUST AIRCRAFT CABLE
STEP 2. INSTALL FIRST FIXTURE
INSERT AIRCRAFT CABLE IN
CROSS CABLE GRIPPER AND
FASTEN SECURITY SCREW.
!
MAKE SURE THE FIXTURE IS
LEVEL BEFORE CUTTING THE
EXCESS AIRCRAFT CABLE.
NOTICE
SECURITY
SCREW
PRESS PIN TO RELEASE CABLE.
STEP 4. PREPARE CANOPY HARDWARE
100-277V
INSTALL STRAIN
RELIEF CONNECTOR
ON FEEDING CABLE.
NOTICE
STEP 5. ELECTRICAL CONNECTIONS
347V
INSTALL BUSHING
ON FEEDING CABLE.
100-277V
STEP 6. ATTACH CABLES
347V
TIE A KNOT IN THE
FEEDING CABLE.
KEEP ENOUGH CABLE LENGTH TO MAKE CONNECTIONS.
MAKE ELECTRICAL CONNECTIONS IN JUNCTION BOX,
SEE WIRING DETAIL.
USE PLUG TO COVER EXTRA CANOPY HOLE.
INSTALL CANOPY.
ATTACH FEEDING CABLE TO
AIRCRAFT CABLE WITH CABLE TIES.
ENSURE CABLE TIES ARE EVENLY
SPACED AND ALIGNED.
CUT EXCESS CABLE TIE LENGTHS.
CONTINUOUS RUNS AND SHAPES
STEP 8. PULL OUT REFLECTOR ASSEMBLIES
STEP 7. REMOVE LENSES
REFER TO YOUR SUBMITTAL
DRAWING FOR THE FIXTURE
CODE AND LOCATION IN THE
RUN OR SHAPE.
TOP VIEW
*FOR ALL FIXTURES:
USE PROVIDED TOOL TO REMOVE
ALL LENSES FROM FIXTURES.
TO SIMPLIFY INSTALLATION, KEEP
LENSES STORED BY FIXTURE TYPE
IN A SECURE PLACE.
*FOR ALL FIXTURES:
PULL TABS AT FIXTURE'S END
TO RELEASE REFLECTOR
ASSEMBLY
FROM THE HOUSING.
*FOR ALL FIXTURES:
DISCONNECT AND REMOVE
REFLECTORS.
NOTICE
STORE REFLECTORS BY
FIXTURE TYPE
IN A SECURE PLACE.
*FOR ALL FIXTURES
LOOSEN SAFETY
SCREWS AND PULL TO
REMOVE BOTTOM
COVER FROM FIXTURE.
bin™, a proprietary binning method, guarantees color temperature consistency within a 3-step MacAdam ellipse.
™
Combine lumentranslator with Lumentalk-enabled luminaires housing Lumenpulse's proprietary lumenear control card to build your Lumentalk system.
p.2/3
2016.07.28
EM - R10
Lumenpulse, 1751 Richardson, Suite 1505, Montreal (Quebec) Canada H3K 1G6 1.877.937.3003 P. 514.937.3003 F. 514.937.6289
[email protected] www.lumenpulse.com
Copyright © Lumenpulse 2016
Confidential and proprietary
Lumenpulse reserves the right to make changes to this product and related instructions at any time without prior notice
and such changes shall be effective immediately. See www.lumenpulse.com/support/downloads for current data and instructions.
lumenline™2
INSTALLATION INSTRUCTIONS
drawing number 109781
PENDANT
INDIRECT LIGHTING
This product must be installed in accordance with applicable national and local electrical and construction
codes by a person familiar with the construction and operation of the product and the hazards involved.
Failure to comply with the following installation instructions may result in death or serious injury.
!
STEP 9. INSTALL FIRST FIXTURE
PLANNING A SHAPE INSTALLATION
!
WARNING
MOUNTING
POINT
DO NOT PRE-INSTALL FULL FIXTURE RUN
OR COMPLETE SHAPE ON THE FLOOR.
IF FIRST FIXTURE HAS TWO
MOUNTING POINTS,
INSTALL ACCORDING TO
STEPS 1-8 AND CONTINUE
WITH STEPS 10-15.
LIT JOINER WITH
MOUNTING
POINT
FIRST
OR END
LIT JOINER WITH
MOUNTING
POINT
PRE-ASSEMBLED PART 3
MOUNTING
POINT
MID
FOR SHAPES:
IF FIRST FIXTURE HAS ONE
MOUNTING POINT,
PREASSEMBLE NEXT FIXTURE
AND/OR JOINER FOR
SECOND MOUNTING
POINT (STEPS 11-15).
PRE-ASSEMBLED
PART 2
PART 4
CONTINUE WITH STEPS 1-8
AND STEPS 10-15.
TOP VIEW
LIT JOINER WITH
MOUNTING
POINT
MOUNTING
POINT
MOUNTING
POINT
MID
MOUNTING
POINT
MID
PART 4
MID
MID
FIRST
PART 1
STARTING POINT
STEP 11. SECURE JOINER PLATES
STEP 10. INSTALL MIDDLE OF RUN FIXTURE
PART 5
LIT JOINER WITH
MOUNTING
POINT
TOP VIEW
LIT JOINER WITH
MOUNTING
POINT
PRE-ASSEMBLED PART 1
STARTING POINT
MID
MOUNTING
POINT
MID
MID
PART 6
PART 2
PART 3
STEP 12. PULL OUT ALIGNMENT BARS
INSTALL MIDDLE OF RUN
FIXTURE STARTING WITH
CEILING ANCHOR SIDE.
FACTORY
INSTALLED
!
WARNING
MAKE SURE THE WIRES ARE NOT
PINCHED BY COMPONENTS.
FIRST OF RUN
SECURE JOINER PLATES WITH SCREWS
(2x) AND NUTS (2x). DO NOT FULLY
TIGHTEN SCREWS AT THIS STEP.
MIDDLE OF RUN
INSERT QUICK CONNECT CABLE
ASSEMBLIES THROUGH THE MIDDLE
OF RUN FIXTURE JOINER PLATE.
MAKE SURE THERE IS NO GAP
BETWEEN FIXTURES.
STEP 13. SECURE BOTTOM ALIGNMENT BARS STEP 14. SECURE TOP ALIGNMENT BARS
SIDE VIEW
2X
2X
5/16"
LOOSEN SET SCREWS ON THE 4 ALIGNMENT
BARS AND SLIDE THEM HALFWAY INTO THE
NEXT FIXTURE. PULL CABLE ASSEMBLIES OUT.
STEP 15. INSTALL REMAINING FIXTURES
STEP 16. LEVEL AND ADJUST AIRCRAFT CABLES
NOTICE
EACH PRE-ASSEMBLED PART MUST
HAVE ONE MOUNTING POINT.
FOR REMAINING FIXTURES AND
JOINERS IN THE SHAPE:
PREASSEMBLE ACCORDING TO STEPS
11-15.
SECURE BOTTOM
ALIGNMENT BARS BY
TIGHTENING 2 SET
SCREWS.
SECURE TOP
ALIGNMENT BARS BY
LOOSELY TIGHTENING
2 SET SCREWS.
2X
3/16"
STEP 17. INSTALL BOTTOM COVER
NOTICE
REFER TO THE
OPTIC GUIDELINES
ON PAGE 1
BEFORE
INSTALLING
REFLECTOR
ASSEMBLIES AND
LENSES.
INSTALL ACCORDING TO STEPS 10-16.
REFER TO PLANNING A SHAPE
SECTION ABOVE FOR DETAILS.
2X
3/16"
FOR REMAINING FIXTURES IN THE RUN:
INSTALL ACCORDING TO STEPS 10-16.
MAKE SURE THE FIXTURE IS LEVEL
BEFORE CUTTING THE EXCESS CABLE.
WARNING
AFTER LEVELING, TIGHTEN THE
JOINER PLATE SCREWS TO SECURE
THE LEVELNESS OF THE RUN.
STEP 18. INSTALL REFLECTOR ASSEMBLIES
SUPPORT
PLATES
2X
NOTICE
!
123456
CLIP AND SCREW
BOTTOM COVER
WITH 2x SCREWS
#6-32 x 1 5/8''
THROUGH
SUPPORT PLATES.
MIDDLE OF RUN
NOTICE
RECORD THE LOCATION OF EACH
FIXTURE BY SERIAL NUMBER ON
REFLECTOR TO PREPARE FOR THE
COMMISSIONING PROCESS
(DMX/RDM).
FIRST OF RUN
MIDDLE OF RUN
REINSTALL AND CONNECT REFLECTOR ASSEMBLIES IN FIXTURE
HOUSING. MAKE SURE TO EVENLY SPACE REFLECTOR ASSEMBLIES.
MAKE SURE THE WIRES ARE NOT PINCHED BY COMPONENTS.
CONNECT POWER AND DATA QUICK CONNECT CABLE
ASSEMBLIES.
STEP 19. INSTALL LENSES
NOTICE
TO ALLOW FOR MATERIAL EXPANSION, USE
THE LENS REMOVAL TOOL TO CREATE A SMALL
GAP BETWEEN THE LENS AND ENDCAP.
bin™, a proprietary binning method, guarantees color temperature consistency within a 3-step MacAdam ellipse.
™
Combine lumentranslator with Lumentalk-enabled luminaires housing Lumenpulse's proprietary lumenear control card to build your Lumentalk system.
p.3/3
2016.07.28
EM - R10
Lumenpulse, 1751 Richardson, Suite 1505, Montreal (Quebec) Canada H3K 1G6 1.877.937.3003 P. 514.937.3003 F. 514.937.6289
[email protected] www.lumenpulse.com
Copyright © Lumenpulse 2016
Confidential and proprietary
Lumenpulse reserves the right to make changes to this product and related instructions at any time without prior notice
and such changes shall be effective immediately. See www.lumenpulse.com/support/downloads for current data and instructions.