Installation Instructions PDF
Transcription
Installation Instructions PDF
lumenline™2 INSTALLATION INSTRUCTIONS drawing number 109781 ! ! WARNING ! SEPARATION OF FIELD INSTALLED POWER LIMITED CIRCUIT (DIMMING/CONTROL) WIRING FROM THE BRANCH CIRCUIT WIRING IN THE OUTLET BOX ARE TO BE MADE IN ACCORDANCE WITH LOCAL AND/OR NATIONAL ELECTRICAL INSTALLATION CODES. INSTALLATION HARDWARE WARNING ! DO NOT PRE-INSTALL FULL FIXTURE RUN OR COMPLETE SHAPE ON THE FLOOR. ! WARNING ! WARNING DO NOT USE IF FIXTURE, PARTS OR CONNECTORS ARE DAMAGED. INSTALL ALL MOUNTING HARDWARE ACCORDING TO MANUFACTURER MOUNTING GUIDE. CAUTION WARNING DO NOT EXCEED FIXTURE SPECIFIED VOLTAGE. UNAUTHORIZED FIELD REPAIRS WILL VOID WARRANTY. WIRING DETAIL NON-DIMMING OR LUMENTALK CANOPY CABLE COUPLER WITH AIRCRAFT CABLE STANDARD BRACKET BAR WITH 1/4''-20 STUD AND GROUND SCREW OR PENDANT INDIRECT LIGHTING This product must be installed in accordance with applicable national and local electrical and construction codes by a person familiar with the construction and operation of the product and the hazards involved. Failure to comply with the following installation instructions may result in death or serious injury. 0-10V, DALI OR ECOSYSTEM® From Dimmer or Controller To next fixture Neutral white Ground green Line black 100-347V* Input Line black Ground green Neutral white STRAIN RELIEF OR BUSHING FOR CANOPY Junction box (by others) Data+ red/purple Data- orange Canopy LENS REMOVER TOOL DMX/RDM To fixture Ø5'' FEEDER CANOPY POWER AND DATA WITH HOLE PLUG Ø2'' NON-FEEDER CANOPY Junction box (by others) Canopy CABLE TIE (1 PER 12'' OF CABLE) Line black Ground green Neutral white From CBX 100-347V* & Data input ! 100-347V* & Data output To next fixture 100-347V* Input 100-347V* To next fixture WARNING DISCONNECT POWER BEFORE INSTALLING OR SERVICING TO AVOID ELECTRICAL SHOCK. To fixture Wiring detail Data+ red/purple Data- orange Junction box (by others) Canopy *Lumentalk and RGB options not available with 347V. To fixture WIRE COLOR / USE GREEN WHITE BLACK RED/ PURPLE ORANGE GROUND NEUTRAL LINE 100-347V DATA + DATA - DMX/Data Cable Specification DMX Cable from Controller to CBX and CBX to CBX shall adhere to ANSI E1.11 – 2008 (r2013) – Entertainment Technology – USITT DMX512-A, Asynchronous Serial Digital Data Transmission Standard for Controlling Lighting Equipment and Accessories. At minimum DMX Cable shall be 1-Pair (24 AWG, 7x32 Stranding)Twisted (minimum of 4.8 twists/foot), Shielded, minimum of 100 ohms Impedance, and <25 pF/ft. Capacitance. Combined Power & Data Cable Specification Fixture cabling from CBX to Fixtures shall be installed per NEC and Local Codes. All conductors shall be of the same size and minimum of 16 AWG annealed stranded bare copper per ASTM B-174 and must be a minimum of 26/30 and capable of handling 8 amps. OPTICS GUIDELINES INDIRECT LIGHTING - BATWING WIDE INDIRECT LIGHTING - WIDE FLOOD SYMMETRICAL DISTRIBUTION, NO SPECIFIC ORIENTATION REQUIRED. SYMMETRICAL DISTRIBUTION, NO SPECIFIC ORIENTATION REQUIRED. FOR SINGLE UNITS: CONTINUE INSTALLATION ACCORDING TO STEPS 1-6. FOR SINGLE UNITS: CONTINUE INSTALLATION ACCORDING TO STEPS 1-6. FOR CONTINUOUS RUNS: CONTINUE INSTALLATION ACCORDING TO STEPS 7-19. FOR CONTINUOUS RUNS: CONTINUE INSTALLATION ACCORDING TO STEPS 7-19. bin™, a proprietary binning method, guarantees color temperature consistency within a 3-step MacAdam ellipse. ™ Combine lumentranslator with Lumentalk-enabled luminaires housing Lumenpulse's proprietary lumenear control card to build your Lumentalk system. p.1/3 2016.07.28 EM - R10 Lumenpulse, 1751 Richardson, Suite 1505, Montreal (Quebec) Canada H3K 1G6 1.877.937.3003 P. 514.937.3003 F. 514.937.6289 [email protected] www.lumenpulse.com Copyright © Lumenpulse 2016 Confidential and proprietary Lumenpulse reserves the right to make changes to this product and related instructions at any time without prior notice and such changes shall be effective immediately. See www.lumenpulse.com/support/downloads for current data and instructions. lumenline™2 INSTALLATION INSTRUCTIONS drawing number 109781 ! PENDANT INDIRECT LIGHTING This product must be installed in accordance with applicable national and local electrical and construction codes by a person familiar with the construction and operation of the product and the hazards involved. Failure to comply with the following installation instructions may result in death or serious injury. SINGLE UNITS STEP 1. PREPARE CANOPIES AND AIRCRAFT CABLE ! WARNING USE THREADED STUDS 1/4" - 20 (BY OTHERS) THAT ARE APPROPRIATE FOR USE WITH YOUR MOUNTING SURFACE. BALL TERMINAL BALL TERMINAL NOTICE REFER TO THE OPTICS GUIDELINES ON PAGE 1 BEFORE INSTALLING THE FIRST FIXTURE. INSTALL BRACKET BAR TO JUNCTION BOX. SCREW COUPLER ON BRACKET BAR. INSTALL ALL NON-FEEDER CANOPIES. SEPARATE FEEDER CANOPY COUPLER. FEED AIRCRAFT CABLE THROUGH CANOPY AND COUPLER. LEAVE CANOPY HANGING. KEEP BALL TERMINAL ON HIGH END OF THE CABLE. STEP 3. ADJUST AIRCRAFT CABLE STEP 2. INSTALL FIRST FIXTURE INSERT AIRCRAFT CABLE IN CROSS CABLE GRIPPER AND FASTEN SECURITY SCREW. ! MAKE SURE THE FIXTURE IS LEVEL BEFORE CUTTING THE EXCESS AIRCRAFT CABLE. NOTICE SECURITY SCREW PRESS PIN TO RELEASE CABLE. STEP 4. PREPARE CANOPY HARDWARE 100-277V INSTALL STRAIN RELIEF CONNECTOR ON FEEDING CABLE. NOTICE STEP 5. ELECTRICAL CONNECTIONS 347V INSTALL BUSHING ON FEEDING CABLE. 100-277V STEP 6. ATTACH CABLES 347V TIE A KNOT IN THE FEEDING CABLE. KEEP ENOUGH CABLE LENGTH TO MAKE CONNECTIONS. MAKE ELECTRICAL CONNECTIONS IN JUNCTION BOX, SEE WIRING DETAIL. USE PLUG TO COVER EXTRA CANOPY HOLE. INSTALL CANOPY. ATTACH FEEDING CABLE TO AIRCRAFT CABLE WITH CABLE TIES. ENSURE CABLE TIES ARE EVENLY SPACED AND ALIGNED. CUT EXCESS CABLE TIE LENGTHS. CONTINUOUS RUNS AND SHAPES STEP 8. PULL OUT REFLECTOR ASSEMBLIES STEP 7. REMOVE LENSES REFER TO YOUR SUBMITTAL DRAWING FOR THE FIXTURE CODE AND LOCATION IN THE RUN OR SHAPE. TOP VIEW *FOR ALL FIXTURES: USE PROVIDED TOOL TO REMOVE ALL LENSES FROM FIXTURES. TO SIMPLIFY INSTALLATION, KEEP LENSES STORED BY FIXTURE TYPE IN A SECURE PLACE. *FOR ALL FIXTURES: PULL TABS AT FIXTURE'S END TO RELEASE REFLECTOR ASSEMBLY FROM THE HOUSING. *FOR ALL FIXTURES: DISCONNECT AND REMOVE REFLECTORS. NOTICE STORE REFLECTORS BY FIXTURE TYPE IN A SECURE PLACE. *FOR ALL FIXTURES LOOSEN SAFETY SCREWS AND PULL TO REMOVE BOTTOM COVER FROM FIXTURE. bin™, a proprietary binning method, guarantees color temperature consistency within a 3-step MacAdam ellipse. ™ Combine lumentranslator with Lumentalk-enabled luminaires housing Lumenpulse's proprietary lumenear control card to build your Lumentalk system. p.2/3 2016.07.28 EM - R10 Lumenpulse, 1751 Richardson, Suite 1505, Montreal (Quebec) Canada H3K 1G6 1.877.937.3003 P. 514.937.3003 F. 514.937.6289 [email protected] www.lumenpulse.com Copyright © Lumenpulse 2016 Confidential and proprietary Lumenpulse reserves the right to make changes to this product and related instructions at any time without prior notice and such changes shall be effective immediately. See www.lumenpulse.com/support/downloads for current data and instructions. lumenline™2 INSTALLATION INSTRUCTIONS drawing number 109781 PENDANT INDIRECT LIGHTING This product must be installed in accordance with applicable national and local electrical and construction codes by a person familiar with the construction and operation of the product and the hazards involved. Failure to comply with the following installation instructions may result in death or serious injury. ! STEP 9. INSTALL FIRST FIXTURE PLANNING A SHAPE INSTALLATION ! WARNING MOUNTING POINT DO NOT PRE-INSTALL FULL FIXTURE RUN OR COMPLETE SHAPE ON THE FLOOR. IF FIRST FIXTURE HAS TWO MOUNTING POINTS, INSTALL ACCORDING TO STEPS 1-8 AND CONTINUE WITH STEPS 10-15. LIT JOINER WITH MOUNTING POINT FIRST OR END LIT JOINER WITH MOUNTING POINT PRE-ASSEMBLED PART 3 MOUNTING POINT MID FOR SHAPES: IF FIRST FIXTURE HAS ONE MOUNTING POINT, PREASSEMBLE NEXT FIXTURE AND/OR JOINER FOR SECOND MOUNTING POINT (STEPS 11-15). PRE-ASSEMBLED PART 2 PART 4 CONTINUE WITH STEPS 1-8 AND STEPS 10-15. TOP VIEW LIT JOINER WITH MOUNTING POINT MOUNTING POINT MOUNTING POINT MID MOUNTING POINT MID PART 4 MID MID FIRST PART 1 STARTING POINT STEP 11. SECURE JOINER PLATES STEP 10. INSTALL MIDDLE OF RUN FIXTURE PART 5 LIT JOINER WITH MOUNTING POINT TOP VIEW LIT JOINER WITH MOUNTING POINT PRE-ASSEMBLED PART 1 STARTING POINT MID MOUNTING POINT MID MID PART 6 PART 2 PART 3 STEP 12. PULL OUT ALIGNMENT BARS INSTALL MIDDLE OF RUN FIXTURE STARTING WITH CEILING ANCHOR SIDE. FACTORY INSTALLED ! WARNING MAKE SURE THE WIRES ARE NOT PINCHED BY COMPONENTS. FIRST OF RUN SECURE JOINER PLATES WITH SCREWS (2x) AND NUTS (2x). DO NOT FULLY TIGHTEN SCREWS AT THIS STEP. MIDDLE OF RUN INSERT QUICK CONNECT CABLE ASSEMBLIES THROUGH THE MIDDLE OF RUN FIXTURE JOINER PLATE. MAKE SURE THERE IS NO GAP BETWEEN FIXTURES. STEP 13. SECURE BOTTOM ALIGNMENT BARS STEP 14. SECURE TOP ALIGNMENT BARS SIDE VIEW 2X 2X 5/16" LOOSEN SET SCREWS ON THE 4 ALIGNMENT BARS AND SLIDE THEM HALFWAY INTO THE NEXT FIXTURE. PULL CABLE ASSEMBLIES OUT. STEP 15. INSTALL REMAINING FIXTURES STEP 16. LEVEL AND ADJUST AIRCRAFT CABLES NOTICE EACH PRE-ASSEMBLED PART MUST HAVE ONE MOUNTING POINT. FOR REMAINING FIXTURES AND JOINERS IN THE SHAPE: PREASSEMBLE ACCORDING TO STEPS 11-15. SECURE BOTTOM ALIGNMENT BARS BY TIGHTENING 2 SET SCREWS. SECURE TOP ALIGNMENT BARS BY LOOSELY TIGHTENING 2 SET SCREWS. 2X 3/16" STEP 17. INSTALL BOTTOM COVER NOTICE REFER TO THE OPTIC GUIDELINES ON PAGE 1 BEFORE INSTALLING REFLECTOR ASSEMBLIES AND LENSES. INSTALL ACCORDING TO STEPS 10-16. REFER TO PLANNING A SHAPE SECTION ABOVE FOR DETAILS. 2X 3/16" FOR REMAINING FIXTURES IN THE RUN: INSTALL ACCORDING TO STEPS 10-16. MAKE SURE THE FIXTURE IS LEVEL BEFORE CUTTING THE EXCESS CABLE. WARNING AFTER LEVELING, TIGHTEN THE JOINER PLATE SCREWS TO SECURE THE LEVELNESS OF THE RUN. STEP 18. INSTALL REFLECTOR ASSEMBLIES SUPPORT PLATES 2X NOTICE ! 123456 CLIP AND SCREW BOTTOM COVER WITH 2x SCREWS #6-32 x 1 5/8'' THROUGH SUPPORT PLATES. MIDDLE OF RUN NOTICE RECORD THE LOCATION OF EACH FIXTURE BY SERIAL NUMBER ON REFLECTOR TO PREPARE FOR THE COMMISSIONING PROCESS (DMX/RDM). FIRST OF RUN MIDDLE OF RUN REINSTALL AND CONNECT REFLECTOR ASSEMBLIES IN FIXTURE HOUSING. MAKE SURE TO EVENLY SPACE REFLECTOR ASSEMBLIES. MAKE SURE THE WIRES ARE NOT PINCHED BY COMPONENTS. CONNECT POWER AND DATA QUICK CONNECT CABLE ASSEMBLIES. STEP 19. INSTALL LENSES NOTICE TO ALLOW FOR MATERIAL EXPANSION, USE THE LENS REMOVAL TOOL TO CREATE A SMALL GAP BETWEEN THE LENS AND ENDCAP. bin™, a proprietary binning method, guarantees color temperature consistency within a 3-step MacAdam ellipse. ™ Combine lumentranslator with Lumentalk-enabled luminaires housing Lumenpulse's proprietary lumenear control card to build your Lumentalk system. p.3/3 2016.07.28 EM - R10 Lumenpulse, 1751 Richardson, Suite 1505, Montreal (Quebec) Canada H3K 1G6 1.877.937.3003 P. 514.937.3003 F. 514.937.6289 [email protected] www.lumenpulse.com Copyright © Lumenpulse 2016 Confidential and proprietary Lumenpulse reserves the right to make changes to this product and related instructions at any time without prior notice and such changes shall be effective immediately. See www.lumenpulse.com/support/downloads for current data and instructions.