109784_LUMENPULSE_Lumenline_LLI2P D_LLI2P RG

Transcription

109784_LUMENPULSE_Lumenline_LLI2P D_LLI2P RG
lumenline™2
INSTALLATION INSTRUCTIONS
drawing number 109784
!
!
This product must be installed in accordance with applicable national and local electrical and construction
codes by a person familiar with the construction and operation of the product and the hazards involved.
Failure to comply with the following installation instructions may result in death or serious injury.
WARNING
WARNING
!
SEPARATION OF FIELD INSTALLED POWER
LIMITED CIRCUIT (DIMMING/CONTROL)
WIRING FROM THE BRANCH CIRCUIT WIRING
IN THE OUTLET BOX ARE TO BE MADE IN
ACCORDANCE WITH LOCAL AND/OR
NATIONAL ELECTRICAL INSTALLATION CODES.
INSTALLATION HARDWARE
WARNING
!
WARNING
DO NOT USE IF FIXTURE, PARTS OR
CONNECTORS ARE DAMAGED.
INSTALL ALL MOUNTING HARDWARE
ACCORDING TO MANUFACTURER
MOUNTING GUIDE.
CAUTION
WARNING
!
DO NOT EXCEED FIXTURE SPECIFIED VOLTAGE.
UNAUTHORIZED FIELD REPAIRS WILL VOID WARRANTY.
WIRING DETAIL
NON-DIMMING OR LUMENTALK
CANOPY CABLE
COUPLER WITH
AIRCRAFT CABLE
0-10V, DALI OR ECOSYSTEM®
From Dimmer or Controller
To next fixture
Line black
Ground green
Neutral white
Neutral white
Ground green
Line black
STANDARD
BRACKET BAR WITH
1/4''-20 STUD AND
GROUND SCREW
OR
!
DO NOT PRE-INSTALL FULL FIXTURE RUN
OR COMPLETE SHAPE ON THE FLOOR.
PENDANT
DIRECT LIGHTING
REGRESSED LENS DIRECT LIGHTING
100-347V*
To next fixture
100-347V*
Input
STRAIN RELIEF OR
BUSHING FOR CANOPY
Data+ red/purple
Data- orange
Junction box
(by others)
DMX/RDM
Line black
Ground green
Neutral white
To fixture
Ø5'' FEEDER
CANOPY POWER
AND DATA WITH
HOLE PLUG
Ø2'' NON-FEEDER
CANOPY
LENS REMOVER
TOOL
!
Junction box
(by others)
Canopy
Canopy
CABLE TIE (1 PER
12'' OF CABLE)
100-347V*
& Data output
To next fixture
100-347V*
Input
WARNING
DISCONNECT POWER BEFORE
INSTALLING OR SERVICING TO
AVOID ELECTRICAL SHOCK.
From CBX
100-347V*
& Data input
Wiring detail
Data+ red/purple
Data- orange
WIRE COLOR / USE
Junction box
(by others)
GREEN
WHITE
BLACK
RED/ PURPLE
ORANGE
Canopy
*Lumentalk and RGB options not available with 347V.
To fixture
To fixture
GROUND
NEUTRAL
LINE 100-347V
DATA +
DATA -
DMX/Data Cable Specification
DMX Cable from Controller to CBX and CBX to CBX shall adhere to ANSI E1.11 – 2008 (r2013) – Entertainment Technology – USITT DMX512-A, Asynchronous Serial Digital Data Transmission Standard for
Controlling Lighting Equipment and Accessories. At minimum DMX Cable shall be 1-Pair (24 AWG, 7x32 Stranding)Twisted (minimum of 4.8 twists/foot), Shielded, minimum of 100 ohms Impedance, and <25
pF/ft. Capacitance.
Combined Power & Data Cable Specification
Fixture cabling from CBX to Fixtures shall be installed per NEC and Local Codes. All conductors shall be of the same size and minimum of 16 AWG annealed stranded bare copper per ASTM B-174 and must be a
minimum of 26/30 and capable of handling 8 amps.
OPTICS GUIDELINES
DIRECT LIGHTING - WIDE FLOOD OPTIC
SYMMETRICAL DISTRIBUTION, NO SPECIFIC ORIENTATION REQUIRED.
FOR SINGLE UNITS:
CONTINUE INSTALLATION ACCORDING TO STEPS 1-6.
FOR CONTINUOUS RUNS:
CONTINUE INSTALLATION ACCORDING TO STEPS 7-18.
DIRECT LIGHTING - NARROW FLOOD OPTIC (NOT AVAILABLE FOR REGRESSED LENS FIXTURES, RGB OR SHAPES WITH LIT JOINERS)
CAUTION
LOUVERS ARE FRAGILE, HANDLE WITH CARE
THROUGHOUT THE INSTALLATION.
SYMMETRICAL DISTRIBUTION, NO SPECIFIC ORIENTATION REQUIRED.
FOR SINGLE UNITS: CONTINUE INSTALLATION ACCORDING TO STEPS 1-6.
FOR CONTINUOUS RUNS: CONTINUE INSTALLATION ACCORDING TO STEPS 7-18.
ALWAYS WEAR CLEAN LATEX OR COTTON GLOVES
TO AVOID SPOTS OR FINGERPRINT MARKS ON THE
LOUVERS AND TO PROTECT THE REFLECTORS
DURING HANDLING.
DIRECT LIGHTING - TRUE ASYMMETRIC WALLWASH ORIENTATION (NOT AVAILABLE FOR REGRESSED LENS FIXTURES, RGB OR SHAPES WITH LIT JOINERS)
CAUTION
REFLECTOR LABEL
LOUVERS ARE FRAGILE, HANDLE WITH
CARE THROUGHOUT THE INSTALLATION.
NOTICE
WALL /MUR /PARED
ALWAYS POSITION LOUVER BLADES TOWARD THE WALL.
THE WALL SIDE OF THE
REFLECTOR IS IDENTIFIED
WITH A "WALL" LABEL.
POSITION THE REFLECTOR IN
THE LUMENLINE HOUSING
ACCORDING TO THE WALL
SIDE OF YOUR INSTALLATION.
STANDARD
FEEDING
SIDE
WALL SIDE
BOTTOM VIEW
ALWAYS WEAR CLEAN LATEX OR
COTTON GLOVES TO AVOID SPOTS OR
FINGERPRINT MARKS ON THE LOUVERS
AND TO PROTECT THE REFLECTORS
DURING HANDLING.
FOR SINGLE UNITS:
CONTINUE INSTALLATION ACCORDING TO
STEPS 1-6.
FOR CONTINUOUS RUNS:
CONTINUE INSTALLATION ACCORDING TO
STEPS 7-18.
bin™, a proprietary binning method, guarantees color temperature consistency within a 3-step MacAdam ellipse.
™
Combine lumentranslator with Lumentalk-enabled luminaires housing Lumenpulse's proprietary lumenear control card to build your Lumentalk system.
p.1/3
2016.07.28
EM - R9
Lumenpulse, 1751 Richardson, Suite 1505, Montreal (Quebec) Canada H3K 1G6 1.877.937.3003 P. 514.937.3003 F. 514.937.6289
[email protected] www.lumenpulse.com
Copyright © Lumenpulse 2016
Confidential and proprietary
Lumenpulse reserves the right to make changes to this product and related instructions at any time without prior notice
and such changes shall be effective immediately. See www.lumenpulse.com/support/downloads for current data and instructions.
lumenline™2
INSTALLATION INSTRUCTIONS
drawing number 109784
!
This product must be installed in accordance with applicable national and local electrical and construction
codes by a person familiar with the construction and operation of the product and the hazards involved.
Failure to comply with the following installation instructions may result in death or serious injury.
PENDANT
DIRECT LIGHTING
REGRESSED LENS DIRECT LIGHTING
SINGLE UNITS
STEP 1. PREPARE CANOPIES AND AIRCRAFT CABLE
!
BALL
TERMINAL
WARNING
USE THREADED STUDS
1/4" - 20 (BY OTHERS)
THAT ARE APPROPRIATE
FOR USE WITH YOUR
MOUNTING SURFACE.
BALL
TERMINAL
NOTICE
REFER TO THE
OPTICS
GUIDELINES ON
PAGE 1 BEFORE
INSTALLING THE
FIRST FIXTURE.
INSTALL BRACKET BAR TO
JUNCTION BOX.
SCREW COUPLER
ON BRACKET BAR.
INSTALL ALL NON-FEEDER
CANOPIES.
SEPARATE FEEDER CANOPY
COUPLER. FEED AIRCRAFT
CABLE THROUGH CANOPY
AND COUPLER.
LEAVE CANOPY
HANGING.
KEEP BALL TERMINAL ON
HIGH END OF THE CABLE.
STEP 2. INSTALL FIRST FIXTURE
STEP 3. ADJUST AIRCRAFT CABLE
INSERT AIRCRAFT CABLE IN
CROSS CABLE GRIPPER AND
FASTEN SECURITY SCREW.
!
NOTICE
MAKE SURE THE FIXTURE IS
LEVEL BEFORE CUTTING THE
EXCESS AIRCRAFT CABLE.
NOTICE
SECURITY SCREW
PRESS PIN TO RELEASE CABLE.
STEP 5. ELECTRICAL CONNECTIONS
STEP 4. PREPARE CANOPY HARDWARE
100-277V
INSTALL STRAIN
RELIEF CONNECTOR
ON FEEDING CABLE.
347V
INSTALL BUSHING
ON FEEDING CABLE.
100-277V
STEP 6. ATTACH CABLES
347V
TIE A KNOT IN THE
FEEDING CABLE.
KEEP ENOUGH CABLE LENGTH TO MAKE CONNECTIONS.
MAKE ELECTRICAL CONNECTIONS IN JUNCTION BOX,
SEE WIRING DETAIL.
USE PLUG TO COVER EXTRA CANOPY HOLE.
INSTALL CANOPY.
ATTACH FEEDING CABLE TO
AIRCRAFT CABLE WITH CABLE TIES.
ENSURE CABLE TIES ARE EVENLY
SPACED AND ALIGNED.
CUT EXCESS CABLE TIE LENGTHS.
CONTINUOUS RUNS AND SHAPES
STEP 7. REMOVE LENSES OR LOUVERS
STEP 8. PULL OUT REFLECTOR ASSEMBLIES
REFER TO YOUR SUBMITTAL DRAWING FOR THE
FIXTURE CODE AND LOCATION IN THE RUN OR
SHAPE.
*FOR ALL FIXTURES:
TO REMOVE ALL LENSES FROM FIXTURES, USE
PROVIDED TOOL.
TO REMOVE ALL LOUVERS FROM FIXTURES, WEAR
GLOVES AND GENTLY PULL ON LOUVERS.
TO SIMPLIFY INSTALLATION, KEEP LENSES OR
LOUVERS STORED BY FIXTURE TYPE IN A SECURE
PLACE.
BOTTOM VIEW
*FOR ALL FIXTURES:
PUSH SPRING CLIPS AT
FIXTURE'S END TO RELEASE
REFLECTOR ASSEMBLY
FROM THE HOUSING.
NOTICE
STORE REFLECTORS BY FIXTURE TYPE
IN A SECURE PLACE.
*FOR ALL FIXTURES:
DISCONNECT AND REMOVE REFLECTORS.
bin™, a proprietary binning method, guarantees color temperature consistency within a 3-step MacAdam ellipse.
™
Combine lumentranslator with Lumentalk-enabled luminaires housing Lumenpulse's proprietary lumenear control card to build your Lumentalk system.
p.2/3
2016.07.28
EM - R9
Lumenpulse, 1751 Richardson, Suite 1505, Montreal (Quebec) Canada H3K 1G6 1.877.937.3003 P. 514.937.3003 F. 514.937.6289
[email protected] www.lumenpulse.com
Copyright © Lumenpulse 2016
Confidential and proprietary
Lumenpulse reserves the right to make changes to this product and related instructions at any time without prior notice
and such changes shall be effective immediately. See www.lumenpulse.com/support/downloads for current data and instructions.
lumenline™2
INSTALLATION INSTRUCTIONS
drawing number 109784
!
This product must be installed in accordance with applicable national and local electrical and construction
codes by a person familiar with the construction and operation of the product and the hazards involved.
Failure to comply with the following installation instructions may result in death or serious injury.
STEP 9. INSTALL FIRST FIXTURE
PENDANT
DIRECT LIGHTING
REGRESSED LENS DIRECT LIGHTING
PLANNING A SHAPE INSTALLATION
!
WARNING
MOUNTING
POINT
DO NOT PRE-INSTALL FULL FIXTURE RUN
OR COMPLETE SHAPE ON THE FLOOR.
IF FIRST FIXTURE HAS TWO
MOUNTING POINTS,
INSTALL ACCORDING TO
STEPS 1-8 AND CONTINUE
WITH STEPS 10-15.
LIT JOINER WITH
MOUNTING
POINT
FIRST
OR END
LIT JOINER WITH
MOUNTING
POINT
PRE-ASSEMBLED PART 3
MOUNTING
POINT
MID
PRE-ASSEMBLED
PART 2
FOR SHAPES:
IF FIRST FIXTURE HAS ONE
MOUNTING POINT,
PREASSEMBLE NEXT FIXTURE
AND/OR JOINER FOR
SECOND MOUNTING
POINT (STEPS 10, 12-15).
PART 4
MID
CONTINUE WITH STEPS 1-8
AND STEPS 10-15.
LIT JOINER WITH
MOUNTING
POINT
MOUNTING
POINT
STEP 10. PULL OUT ALIGNMENT BARS
TOP VIEW
LIT JOINER WITH
MOUNTING
POINT
PRE-ASSEMBLED PART 1
STARTING POINT
STEP 11. INSTALL NEXT FIXTURE
MID
PART 5
MID
PART 4
MOUNTING
POINT
MID
MID
PART 6
MOUNTING
POINT
MOUNTING
POINT
FIRST
MID
MID
TOP VIEW
PART 1
STARTING POINT
PART 2
PART 3
LIT JOINER WITH
MOUNTING
POINT
STEP 12. INSERT CABLE ASSEMBLIES
INSTALL NEXT FIXTURE
STARTING WITH CEILING
ANCHOR SIDE.
INSERT QUICK CONNECT
CABLE ASSEMBLIES
THROUGH THE MIDDLE OF
RUN FIXTURE JOINER PLATE.
SLIDE ALIGNMENT BARS
HALFWAY OUT.
STEP 13. JOIN FIXTURES
STEP 14. SECURE JOINER PLATES
STEP 15. INSTALL REMAINING FIXTURES
STEP 16. LEVEL AND ADJUST AIRCRAFT CABLES
NOTICE
EACH PRE-ASSEMBLED PART MUST
HAVE ONE MOUNTING POINT.
FOR REMAINING FIXTURES AND
JOINERS IN THE SHAPE:
PREASSEMBLE ACCORDING TO STEPS
10, 12-15.
INSERT ALIGNMENT BARS INTO THE
MIDDLE OF RUN FIXTURE AND JOIN
BOTH FIXTURES.
CENTER ALIGNMENT BARS IN FIXTURES.
!
WARNING
MAKE SURE THE WIRES ARE NOT
PINCHED BY COMPONENTS.
SECURE JOINER PLATES WITH
SCREWS (2x). DO NOT FULLY
TIGHTEN AT THIS STEP.
MAKE SURE THERE IS NO GAP
BETWEEN THE FIXTURES.
2X
INSTALL ACCORDING TO STEPS 10-16.
REFER TO PLANNING A SHAPE
SECTION ABOVE FOR DETAILS.
FOR REMAINING FIXTURES IN THE RUN:
INSTALL ACCORDING TO STEPS 10-16.
MIDDLE OF RUN
NOTICE
MAKE SURE THE FIXTURE IS LEVEL
BEFORE CUTTING THE EXCESS CABLE.
AFTER LEVELING, TIGHTEN THE JOINER
PLATE SCREWS TO SECURE THE
LEVELNESS OF THE RUN.
STEP 17. INSTALL REFLECTOR ASSEMBLIES
REINSTALL AND CONNECT
REFLECTOR ASSEMBLIES IN
FIXTURE HOUSING.
MAKE SURE TO EVENLY SPACE
REFLECTOR ASSEMBLIES.
123456
NOTICE
REFER TO THE OPTICS GUIDELINES
ON PAGE 1 BEFORE INSTALLING
REFLECTOR ASSEMBLIES AND
LENSES OR LOUVERS.
FIRST OF RUN
MAKE SURE THE WIRES ARE
NOT PINCHED BY
COMPONENTS.
MIDDLE OF RUN
NOTICE
CONNECT POWER AND DATA
QUICK CONNECT CABLE
ASSEMBLIES.
RECORD THE LOCATION OF EACH
FIXTURE BY SERIAL NUMBER ON
REFLECTOR TO PREPARE FOR THE
COMMISSIONING PROCESS
(DMX/RDM).
STEP 18. INSTALL LENSES OR LOUVERS
NOTICE
HANDLE ALL LOUVERS WITH GLOVES.
TO ALLOW FOR MATERIAL EXPANSION, USE THE
LENS REMOVAL TOOL TO CREATE A SMALL GAP
BETWEEN THE LENS OR LOUVER AND ENDCAP.
bin™, a proprietary binning method, guarantees color temperature consistency within a 3-step MacAdam ellipse.
™
Combine lumentranslator with Lumentalk-enabled luminaires housing Lumenpulse's proprietary lumenear control card to build your Lumentalk system.
p.3/3
2016.07.28
EM - R9
Lumenpulse, 1751 Richardson, Suite 1505, Montreal (Quebec) Canada H3K 1G6 1.877.937.3003 P. 514.937.3003 F. 514.937.6289