Packaged Air Conditioning Unit
Transcription
Packaged Air Conditioning Unit
...................................................................................................................... RTU Packaged Air Conditioning Unit ...................................................................................................................... RTU .................................................................................................................................................... Packaged Air Conditioning Unit .................................................................................................................................................... The Reznor RTU series is a range of packaged Air Conditioning units, providing cooling and heating. Model Range Reznor's range of high efficiency packaged rooftop units are available in cooling only and reversible modes. Both are available with energy recovery function as an option. >> >> RTU units come in different models with cooling and heat pump capacities ranging from 20 to 300 kW. Features & Benefits Acoustic jackets combined with insulated compressor compartments >> Low noise variable speed condenser fans providing energy efficient operation and head pressure control >> Plug and play controls, compatible with a range of BMS protocols including Modbus, and BACnet >> Energy analyzer >> Variable speed EC fans >> Damper actuators >> Optimised design for R410A refrigerant >> High energy efficiency at both full and part load operation to reduce operating costs >> Low noise levels achieved through high performance fans and use of antivibration blocks for the compressor and refrigeration circuit assembly >> Centrifugal fans with optional EC plug fans for both supply and exhaust airflow >> Active heat recovery option available to provide enhanced cooling and heatpump performance >> Electronic Expansion Valves driver modules >> Digital-scroll or Inverter Compressor driver modules >> CO2 or VOC sensors and control Controls The Reznor RTU utilises Carel Microprocessor Controls to provide automatic operation of cooling, ventilation, heating and heat recovery operation. Additional control options inlcude : >> Remote control operation >> Temperature and/or humidity sensors (up to 6 units) .................................................................................................. Packaged Air Conditioning Unit .................................................................................................. .................................................................................................................................................... Energy Efficiency Multiscroll Technology Annual energy consumption kWh Multiscroll technology combined with electronic expansion valves (EEV) and EC plug fans increase the system energy efficiency and provide a resilient and reliable solution. Multiscroll technology + Electronic Plug-fan Thanks to the RTU's ability to produce its output in smaller increments, spaces with a variable occupancy rate and changing conditions during the day, such as shopping centres, can benefit from energy savings up to 30%. Standard The RTU range of units come equipped as standard with high efficiency G4 class air filters. Fresh air & ventilation options provide a high level of indoor air quality and help ensure a clean and comfortable air conditioned space. Supply air fan Compressors Outdoor fan Return air fan The seasonal efficiency of multiscroll units in tandem from four scroll AC compressors is similar to the equipment with inverter compressors. For units with less than four compressors, high ESEER is achieved thanks to Digital Scroll technology with refrigerant flow control. Comfort - Air Quality and Low Level Noise Up to 30% of savings Up Up to to 30% 30% of of savings savings 0 50 000 100 000 150 000 Typical annual energy consumption for a commercial application Seasonal efficiency comparison 40 30 Multiscroll 20 Optional pre-filters and F6 to F9 filters can be provided. 10 The RTU rooftop can be equipped with Axitop diffusers for the outdoor fans, improving operational efficiency and lowering noise levels. 0 Inverter 2 3 4 6 Number of compressors Free cooling & heat recovery options [DER] Dynamic Energy Recovery. A subcooler in the DX circuit increases the unit's output by 15% without any additional compressors. [AER+] Active Energy Recovery + Digital Scroll: this is Active energy recovery by a compressor group with Digital Scroll technology and EC fan. [AER] Active energy recovery using a separate DX circuit to recover heat, suitable for exhaust rates between 20 and 60% of airflow. [ERH] Free Cooling using a two or three way mixing box, with dampers and automatic controls to use the outside air for free IDA 3 IDA 4 [AERH] Enhanced Active energy recovery Commercial industrial buil- cooling. IDA IDA 33to recover heat, IDA 44 using a separate DX circuit buildings dings IDA Commercial industrial builCommercial industrial builsuitable for exhaust rates between 60 and buildings dings buildings dings 5 l/s pers. 8 l/s pers. 100% of airflow. n minimum ow tilation minimum ntilation minimum 0,55 l/s m 2 88 l/s l/s pers. pers. 0,28 l/s m 2 55 l/s l/s pers. pers. [ACS] Partial condensation energy recovery. Includes a de-superheater that allows using recovered heat for sanitary hot water. [MSC] Multiscroll refrigerant circuit. Available option for series 2000 and 3000, with refrigerant circuit with two compressors in tandem, increases seasonal energy efficiency .................................................................................................. Packaged Air Conditioning Unit .................................................................................................. 3-way mixing box for freecooling and active recovery. Low speed axial fans settings air quality filters G4 F-class filtration double F-class filtration dirty filter indication CO2 sensor duct/ambient settings air quality filters G4 External coils integrated in unit body F-class filtration double F-class filtration Sound insulated scroll compressorsdirty in filter indication duct/ambient included as standard included as standard closed and insulated compartment.CO2 sensor settings settings VOC sensor duct/ambient optionally available optionally available smoke detector quality airairquality filters filters G4G4 ventilation ventilation energy sensor duct/ambient COCO sensor duct/ambient 2 2 condensing pressure control condensing pressure control electronic expansion valve supply/return plug supply/return EC EC plug fanfan active energy recovery external axial external axial EC EC fansfans enhanced active recovery Axitop diffuser Axitop diffuser active energy recovery + digital scroll VOC sensor duct/ambient VOC sensor duct/ambient free cooling thermal/enthalpy smoke detector smoke detector total/partial recovery of condensation heat F-class filtration F-class filtration double F-class filtration double F-class filtration dirty filter indication dirty filter indication installation installation energy energy active energy recovery active energy recovery enhanced active recovery enhanced active recovery active energy recovery + digital active energy recovery + digital scroll scroll cooling thermal/enthalpy freefree cooling thermal/enthalpy total/partial recovery of contotal/partial recovery of condensation heat densation heat settings energy ventilation electronic expansion valve condensing pressure control active energy recovery supply/return EC plug fan enhanced active recovery external axial EC fans + digital active energy recovery scroll Axitop diffuser free cooling thermal/enthalpy Controls and electronic total/partial recovery of concomponents densation heat installation stainless steel internal condensate tray anti-corrosion external condensate tray hot water battery backup polyurethane coating electrical resistance heating 2-phase copper-copper battery antivibration supplement ALUCOAT fins - CrMg alloy antifreeze electrical resistances Blygold coating for low temperatures control stainless internal condensate stainless steelsteel internal condensate traytray Carel controls external condensate external condensate traytray RS485 communication anti-corrosion water battery backup hothot water battery backup electronic expansion valve electronic expansion valve VOC sensor duct/ambient included as standard smoke detector optionally available electrical resistance heating electrical resistance heating 2-phase 2-phase polyurethane coating antivibration supplement antivibration supplement copper-copper battery antifreeze electrical resistances antifreeze electrical resistances ALUCOAT fins - CrMg alloy temperatures forfor lowlow temperatures PGD remote display master-slave management Plant Visor / Watch PRO energy meter BACnet / LonWorks communication Blygold coating settings control control included as standard included as standard optionally available optionally available Double Filtration F Double Filtration F external axial fans E Clogged Filter detectorClogged Filter detector Axitop diffuser .................................................................................................. Packaged Air Conditioning Unit .................................................................................................. CO2 probe ambient/conduit CO2 probe ambient/conduit VOC probe ambient/conduit VOC probe ambient/conduit .................................................................................................................................................... Smoke Detector Assembly type: Supply Supply Smoke Detector installatio Assembly type B - Lower Return Return 0 - Standard A - Two way mixing box S - Lateral B - Lower B - Axial return C - Centrifugal return E - Axial extraction T - Upper S - Lateral D - Dynamic Recovery A - Short side (only with plug ventilat.) T - Upper F - active recovery with return fan energy A - Short side R - Active recovery E energy Return air external condensate B - Return EC plug fan T T A A A S recoverySactive energy S active energy recovery A E antivibration supple B antifreeze electrica temperatur active0 energy recovery active + digital energy recovery + digital for low A B B scroll scroll C - Centrifugal return B E - Extract EC plug fan freecooling thermal/enthalpy freecooling thermal/enthalpy E S total/partial Nrecovery oftotal/partial conrecovery of condensation heat densation heat T A B B S C anti-corrosion anti-corrosion F - Acti v e re co v e r y wi th re tur n fan E S T N B E communication RS4 command PGD supervision Plant Viso copper-copper batterycopper-copper battery B supervision tERA ALUCOAST fin - CrMgALUCOAST alloy S F fin - CrMg alloy B F energy meter Blygold coating communication BACN B T - Fresh air intake B platform CLIMANAG PolyurethaneE coating Polyurethane coating A S B E master-slave manag N A control N S A S electrical resistance N phases) A S enhanced Bactive recovery enhanced activeB recovery B B S Pressure relief dampers Exhaust air N valve electronic expansion valve electronic expansion A S T T stainless steel internal c hot water battery b A - Two way mixing box T Adjustable dampers Fresh air T - External air intake Z - EC plug fan return 0 - Standard N Supply air T Blygold coating Z - Return EC plug fan T T N A S A B S B T N A S E B B B Z .................................................................................................. Packaged Air Conditioning Unit .................................................................................................. Technical Data Model Cooling Only Cooling Capacity Nomin. absorbed power Cooling EER Heat pump Heat Capacity Nomin. absorbed power Cooling EER Nomin. absorbed power Heating COP Airflow (m3/h) 0017 0020 0022 0026 0030 0035 1039 1044 kW kW 17.8 4.9 3.6 20.7 5.8 3.6 23.1 6.4 3.6 25.8 7.0 3.7 30.5 8.5 3.6 34.2 9.3 3.7 41.3 12.5 3.3 46.2 13.3 3.5 kW kW 17.8 5.3 3.6 4.9 4.1 20.7 6.2 3.6 5.5 4.2 32.1 6.4 3.6 6.9 39 25.8 7.7 3.7 7.1 4.1 30.5 9.2 3.6 8.4 4.1 34.2 11.1 3.7 10.8 4.0 40.6 12.9 3.1 11.7 3.5 46 13.9 3.3 13.8 3.4 Supply 3300 3700 4000 4600 5100 6000 6800 7400 Outdoor 9000 9500 14000 14000 14000 20000 20000 20000 1/1 1/1 1/1 1/1 1/1 1/1 1/1 1/1 kW No.compressors /no. circuits Stages Weight Sound pressure level @10m 1 1 1 1 1 1 1 1 Kg 489 495 504 521 538 561 641 660 dB(A) 48 49 49 52 55 57 57 58 Technical Data Model Cooling Only Cooling Capacity Nomin. absorbed power Cooling EER Heat pump Heat Capacity Nomin. absorbed power Cooling EER Nomin. absorbed power Heating COP Airflow (m3/h) 1041 1045 2050 2060 3070 3080 4090 4095 4100 kW kW 42.5 12.2 3.5 47.1 13.4 3.5 52.6 16.8 3.1 66.4 18.5 13.6 74.3 20.8 3.6 80.8 23.4 3.5 95.5 27.6 3.5 95.3 27.4 3.5 105.8 31.2 3.4 kW kW 41.6 13.2 3.2 12.9 3.3 45.9 14.6 3.1 14.8 3.2 52.2 17.6 3.0 15.0 3.5 60.1 19.5 3.1 17.9 3.5 71.3 22.2 3.2 20.6 3.6 77.1 25.2 3.1 23.0 3.5 91.4 29.2 31 27.0 3.4 90.4 29.5 3.1 28.9 3.2 99.8 32.4 3.1 31.0 3.3 kW Supply 6800 7400 8900 10300 12000 13300 15400 15400 17700 Outdoor 20000 20000 25000 24000 26000 26000 36000 36000 36000 2/1 2/1 2/2 2/2 2/2 2/2 2/2 4/2 4/2 2 2 2 2 2 2 2 4 4 Kg 682 694 948 1075 1155 1210 1256 1419 1560 dB(A) 56 57 57 57 58 57 58 58 60 No.compressors /no. circuits Stages Weight Sound pressure level @10m Technical Data Model Cooling Only Cooling Capacity Nomin. absorbed power Cooling EER Heat pump Heat Capacity Nomin. absorbed power Cooling EER Nomin. absorbed power Heating COP Airflow (m3/h) 5120 5135 5140 5150 5170 6200 6230 kW kW 123.6 35.4 3.5 144.0 41.7 3.5 149.8 43.8 3.4 159.8 45.8 3.5 182.1 57.5 3.2 208.9 63.6 3.3 230.5 76.5 3.0 kW kW 118.9 40.2 3.0 37.8 3.1 134.0 45.1 3.0 40.8 3.5 144.4 48.9 3.0 43.7 3.4 155.1 49.5 3.1 46.4 3.4 173.4 60.0 2.9 53.4 3.4 200.6 65.3 3.1 63.7 3.3 218.7 78.7 2.8 81.7 2.9 Supply 19800 22700 23500 24900 28600 31900 36000 Outdoor 56000 56000 56000 56000 76000 76000 76000 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4 4 4 4 4 4 4 2024 2093 2223 2140 2285 2579 2646 61 62 62 61 61 64 65 kW No.compressors /no. circuits Stages Weight Sound pressure level @10m Kg dB(A) .................................................................................................. Packaged Air Conditioning Unit .................................................................................................. ries 0 s eries 0 s eries 1 s eries 1 eries 0 s eries 1 Series 0 Series 1 H H H H H H L L L L L L RETORNO Y RETORNO Y AIRE NUEVOAIRE NUEVO RETORNO Y RETORNO Y AIRE NUEVOAIRE NUEVO A Return Y RETORNO A A Return RETORNO Y AIRE NUEVO A AIRE NUEVO A A IMPULSIÓN IMPULSIÓN IMPULSIÓN IMPULSIÓN Supply Supply IMPULSIÓN IMPULSIÓN series 5-7series 5-7 ries 2-4series 2-4 Series 2-4 eries 2-4 H Series 5-7 series 5-7 H H H H H L L L L L L Return RETORNO Y RETORNO Y AIRE NUEVOAIRE NUEVO A Return RETORNO Y RETORNO Y AIRE NUEVOAIRE NUEVO RETORNO Y AIRE NUEVO A A A RETORNO Y AIRE NUEVO A Supply IMPULSIÓN IMPULSIÓN A Supply IMPULSIÓN IMPULSIÓN IMPULSIÓN IMPULSIÓN Dimensions (mm) Model Series 0 Series Series 0 1 Series 0 DimensionsDimensions standard units standard (mm)units (mm) Series Series 1 2 Series 1 Series 2 Series Series 2 3 Series 3 Series Series 3 4 Series 4 Series Series 4 5 Series 5 Series Series 5 6 Series 6 Series Series 6 7 LL L 2400 2400 2755 2400 2755Dimensions 2755 3055 4575 5175 4575 units 2755 2755 standard 2755 2755 2755(mm) 3055 27553055 4575 AA A Series 0 1370 Series 1 1370 2100 4 5 2100 2100 2 2100 2100 Series 2100 32100 2100 Series 2100 2100 2100 Series 2100 2100 Series 2100 1370 Series 2100 21006 2100 Series 2100 7 2100 2100 2100 H 2755 1175 1430 1555 6350 2490 2490 2200 2200 2200 HL H 2400 1430 2755 1430 1175 A 1370 2100 H 1430 Series 0 Series Series 0 1175 1 2755 3055 4575 5175 1555 1810 1810 1810 1175 1555 18101810 2200 1810 2200 2490 2200 2100 2100 2100 2100 Dimensions Dimensions unit upper unit drawer upper (setdrawer upSC &(set SF)upSC (mm)& SF) (mm) Series Series 1 1555 2 2100 5175 5175 6350 Series 7 Series 7 2100 Series Series 2 1810 3 Series Series 3 1810 4 Series Series 4 2200 5 Series Series 5 2490 6 Series Series 6 2200 7 Series 7 Dimensions Centrifugal Return Air Fan Dimensions unitSection upper2755 drawer (set upSC3055 & SF) (mm) L L (mm) 2400 with2400 2755 2755 2755 2755 2755 3055 4575 4575 5175 5175 6350 Series 0 1370 2100 Series 1 Series Series 3 2100 4 Series 5 4 2100 Series Series Model 2 Series Series 3 Series Series A A 1370 2100 0 2100 2Series 21001 Series 2100 Series 2100 2100 2100 2100 65 2100Series 2100 67 LH L A A H 2400 2050 2755 2050 1830 1370 2100 2755 1830 2230 2400 1370 2100 2755 2755 3055 4575 2230 2490 2490 2490 2755 2755 2490 2490 3055 2100 2100 2100 2100 2100 2100 1830 2230 2490 H*equipment 2050 1830 2230 2490 on request. 2490 * Key CR Key CR equipment can be manufactured can be manufactured in split version in spliton version request. H 2050 6350 6350 * Key CR equipment can be manufactured in split version on request. 5175 2490 2490 4575 2100 6350 2490 5175 2490 2100 6350 Series 7 2100 2490 6350 2100 2100 2100 2100 2490 2490 2490 2490 2490 2490 2490 Reznor RTU Selection Procedure Please photocopy page and send through any enquiries to [email protected] Customer name .............................................. Date.................................... Project reference ......................................................................................... Application Type: Version Mounting Position Cooling Only HP: Heating and cooling Standard Floor Cooling and Gas Fired Dual: HP and Gas Fired Free cooling Roof Recovery Airflow information Supply airflow .............................. m3/s or m3/h Fresh airflow / air rate .............................. m3/s or m3/h Recirculation airflow / air rate .............................. m3/s or m3/h External static pressure on return duct .............................. Pa External static pressure on supply duct .............................. Pa Unit total cooling capacity .............................. kW Unit sensible cooling capacity .............................. kW Indoor air dry bulb .............................. °C Indoor air wet bulb / relative humidity .............................. °C Outdoor air dry bulb .............................. °C .............................. kW Cooling mode design conditions .................. % Heating mode design conditions Heating capacity Auxiliary heat type (if applicable) Electric heat Gas heat LPHW Gas type (if applicable) Natural gas G20 Natural gas G25 Propane Indoor air dry bulb .............................. °C Outdoor air dry bulb .............................. °C Outdoor air wet bulb / relative humidity .............................. °C .............................. % Options Air filter class .............................. Built in digital controller Built in digital controller with BACnet Remote relay interface control External communication protocol Lon Bacnet Modbus Air quality CO2 With Without AXITOP - Acoustic attenuation system With Without Electronic expansion valve With Without Smoke detector With Without Unit control Dirty filter switch Coil coatings With Polyurethane coating int Without Polyurethane coating ext With Without Unit anti vibration mounts With Without GB/REZ/043/0715 Heaters for drain pan Nortek Global HVAC Belgium nv J&M Sabbestraat 130/A000 B-8930 Menen Belgium Tel. +32 (0)56 52 95 11 Fax. +32 (0)56 52 95 33 [email protected] www.reznor.eu Company Standards and Services: All products are tested and approved to CE standards. We are assessed to EN ISO 9001 Quality Assurance. We offer a service to our customers; including budget schemes, on site technical support and a comprehensive after-sales package. We reserve the right to change specifications without prior notice. Errors and omissions excepted.