fire station no. 66 addition

Transcription

fire station no. 66 addition
GENERAL NOTES
1.
2.
3.
WORK NOT IN CONTRACT IS SHOWN FOR
COORDINATION PURPOSES ONLY.
REFER TO CIVIL DRAWINGS FOR EXISTING
SERVICES. NEW SERVICE CONNECTIONS,
GRADING AND DRAINAGE CONNECTION
REFER TO CIVIL DRAWINGS FOR
UNDERGROUND SYSTEMS AND STORM WATER
MANAGEMENT
SITE PLAN DRAWING NOTES
N.I.C.
1
NEW ASPHALT DRIVEWAY PER CIVIL
2
EXISTING BELL PEDESTAL TO REMAIN
3
NEW STORM WATER PONDING DAM
PER CIVIL
N.I.C.
4
CONCRETE PAD PER MECHANICAL
N.I.C.
5
NEW PROTECTIVE BOLLARDS
N.I.C.
6
BARRIER FREE SIGN
N.I.C.
7
EXISTING SIGNAGE AND FLAG POLE
8
NEW SEPTIC TANK PER CIVIL
9
NEW SEPTIC FIELD PER CIVIL
10
N.I.C.
11
EXISTING PROPANE TANK TO BE
REMOVED
EXISTING WELL
12
RELOCATED DONATION BOX PER CIVIL
N.I.C.
13
NEW CULVERT PER CIVIL
N.I.C.
14
EXISTING ASPHALT DRIVEWAY AND
PARKING
EXISTING CONCRETE SURFACE
N.I.C.
16
GRAVEL SURFACE FOR TEMPORARY
GENERATOR
N.I.C.
17
EXISTING CULVERT PER CIVIL
18
DITCH PER CIVIL
19
BARRIER FREE PATH OF TRAVEL.
TRANSITION BETWEEN EXISTING
CONCRETE SURFACE AND ASPHALT TO N.I.C.
BE SMOOTH. LEVEL DIFFERENCE TO
BE NO MORE THAN 13mm
20
GALVANIZED METAL DOWNSPOUTS
AND RAIN WATER LEADER
EXISTING PORTABLE BUILDING TO BE
REMOVED
NEW OIL INTERCEPTOR PER CIVIL
AND MECHANICAL
INFRASTRUCTURE SERVICES & COMMUNITY SUSTAINABILITY /
SERVICES D'INFRASTRUCTURE ET VIABILITÉ DES COLLECTIVITÉS
INFRASTRUCTURE SERVICES BRANCH /
DIRECTION D'INFRASTRUCTURE
DESIGN AND CONSTRUCTION DIVISION /
DIVISION DE LA CONCEPTION ET DE LA CONSTRUCTION
KENT KIRKPATRICK, CITY MANAGER / DIRECTEUR DES SERVICES
MUNICIPAUX
WAYNE NEWELL, DIRECTOR / DIRECTEUR
ROBERT VAILLANCOURT, O.A.A. MANAGER / GESTIONNAIRE O.A.O.
FOR / POUR
VANCES SID
E ROAD
13
18
2
CITY OPERATIONS PORTFOLIO
FIRE SERVICES BRANCH
`ps=^o`efqb`qp
58070
6348
B
6000
pìëí~áå~ÄäÉ=ÇÉëáÖå
HP
B
15
SNPKTOVKPPSO ïïïKÅëîKÅ~
SNPKRSQKUNNU
QMOJNMSS=pçãÉêëÉí=píK=tI=líí~ï~I=lk=hNv=QqP
`lkpriq^kqp
H
12
`çåÅÉéíáçå=ÉÅçäçÖáèìÉ
B
H
7500
11
B
W
TR
H
N.I.C.
W
TR
H
H
W
TR
B
W
TR
H
B
W
TR
H
21
W
TR
H
B
1
W
TR
H
22
W
TR
SITE PLAN LEGEND
H
B
W
TR
ASPHALT
W
TR
H
60904
NUMBER/
NUMÉRO
CONCRETE
B
W
TR
W
TR
B
H
W
TR
BUILDING ENTRY POINT
FH
H
EXISTING FIRE HYDRANT
B
19
14
3285 DUNROBIN RD
EXISTING FIRE STATION
(EXISTING SLAB ON GRADE: 67.68M)
17
5
3
5
HP
EXISTING HYDRO POLE
THIS "ISSUED FOR CONSTRUCTION" ISSUE
IS SOLELY FOR THE CONVENIENCE OF
THE CONTRACTOR AND DOES NOT
ALLEVIATE THE RESPONSIBILITY OF THE
CONTRACTOR FOR ENSURING THAT ALL
ADDENDUM ITEMS AND APPROVED CCN
BE INCORPORATED AS PART OF THE
CONTRACT.
66.18
GAS
34
20
20
20
CE DESSIN CONSTITUE LA PROPRIÉTÉ
DE LA VILLE D'OTTAWA ET TOUT DROIT
D'AUTEUR EST RÉSERVÉ. LES
DIMENSIONS UTILISÉES LE SONT À
DES FINS D'ESTIMATION SEULEMENT.
IL INCOMBE À CHAQUE
ENTREPRENEUR,
SOUS-CONTRACTANT OU
CONSULTANT DE VÉRIFIER TOUTES
LES DIMENSIONS ET LES CONDITIONS
SUR LE CHANTIER. VEUILLEZ
INFORMER LE PROPRIÉTAIRE DE
TOUTE ERREUR OU OMISSION AVANT
D'ENTAMER LES TRAVAUX. NE
DRESSEZ PAS LES PLANS À L'ÉCHELLE.
`lkpqor`qflk=ao^tfkd
GAS
66.18
EXISTING BOLLARDS
DUNROBIN ROAD
B
1670
4121
THIS DRAWING IS THE PROPERTY OF
THE CITY OF OTTAWA AND ALL
COPYRIGHT IS RESERVED.
DIMENSIONS ON DRAWING ARE FOR
ESTIMATING PURPOSES ONLY. IT IS
THE RESPONSIBILITY OF EACH
CONTRACTOR AND
SUB-CONTRACTOR OR CONSULTANT
TO CHECK AND VERIFY ALL
DIMENSIONS AND CONDITIONS ON
SITE. NOTIFY OWNER OF ANY
ERRORS
OR OMISSIONS PRIOR TO
COMMENCING THE WORK. DO NOT
SCALE THE DRAWINGS.
VEHICLE ENTRY POINT
66.18
R
SHEET NUMBER
FH
NEW ADDITION
1 STORY
SLAB ON GRADE: 67.68M
1 DRAWING TITLE
A1.1 SCALE:
15
4
66.18
^ë=áåÇáÅ~íÉÇ
DETAIL NUMBER
SETBACK
B
20
16
SCALE
oKkK=L=jK`K
PROPERTY LINE
8
oKcK
DRAWN BY / DESSINE PAR
BARRIER FREE PATH OF TRAVEL.
SMOOTH HARD SURFACE
H
SAN
W
TR
1500
DATE: (Y/M/D) INITIALS/
(A/M/J)
INITIALES
CHECKED BY / VERIFIE PAR
oKkK
GRASS
H
SAN
W
TR
6
OMNSLMPLNM
OMNSLMPLMN
OMNSLMNLOV
OMNRLNOLOQ
OMNRLNNLNT
OMNRLNNLNP
MILESTONE / FAIT SAILLANT
DESIGNED BY / CONCU PAR
GRAVEL
B
SAN
22
406
fpprba=clo=qbkabo
fpprba=clo=_rfiafkd=mbojfq
fpprba=clo=VVB=`ifbkq=obsfbt
fpprba=clo=SSB=obsfbt
fpprba=clo=PPB=obsfbt
fpprba=clo=`lloafk^qflk
B
SAN
20
PK=jb`e^kf`^iJbib`qof`^i
pjfqe=C=^kaboplk
S
R
Q
P
O
N
18
H
B
9
OK=pqor`qro^i
===j`fkqlpe=mboov
N.I.C.
3
7
NK=`fsfi
===j`fkqlpe=mboov
20
21
10
`ps=^o`efqb`qp
LEGAL DESCRIPTION:
6000
6000
REFERENCE SURVEY:
3
PLAN 5R-9213
PROJECT / LOCATION / PROJET / ENDROIT
FIRE STATION NO. 66
ADDITION
MUNICIPAL ADDRESS:
64116
3285 DUNROBIN ROAD
18
ZONING:
R1 - RURAL INSTITUTIONAL ZONE
3285 Dunrobin Road
Ottawa, Ontario
DEVELOPMENT INFORMATION:
CSV Project No: 2015-0650
LOT FRONTAGE (DUNROBIN RD.):
LOT AREA:
BUILDING AREA - (EXISTING + PROPOSED)
LOT COVERAGE -
1
1 : 200
PROJECT
A100
SITE PLAN
TR
UE
cáäÉ=k~ãÉ=~åÇ=içÅ~íáçåW
`WyrëÉêëyÅ~êÇÉ~äyaçÅìãÉåíëyOMNRJMSRM=aìåêçÄáå=cáêÉ=pí~íáçå||Å~êÇÉ~äKêîí
CONC. 3PT LOT 5 RP 5R9213
PTS 1-3 VANCES SIDE ROAD S/S
PARKING SPACES:
REQUIRED PROVIDED -
DRAWING / DESSIN
pfqb=mi^k
PROPOSED
328 m²
8.5%
4 SPACES
6 (INCLUDING 1 ACCESSIBLE SPACE
DISTANCE FROM EXISTING FIRE
HYDRANT TO THE MAIN ENTRY LOADING SPACE
60.95m
3900m²
BUSINESS ENTITY / NUMÉRO DE L'ENTITÉ
SHEET NO. / FEUILLE No.
BUILDING NUMBER / NUMÉRO DU BÂTIMENT
5.2 m
2 SPACE
PROJECT NO. / NUMÉRO DE PROJET
^NMM
mäçííÉÇ=låW MVLMPLOMNS=NNWNUWRP=^j