ASCO Model 105 Installation Manual
Transcription
ASCO Model 105 Installation Manual
Series 100 Model 105 (Edco DRS Series) DIN Rail Protection Surge Protective Device Technical Documentation The ASCO Model 105 is a din rail mountable, single pair surge suppression module implementing three-stage hybrid technology. This module addresses over-voltage transients with gas tubes and silicon avalanche components. In addition, sneak currents are mitigated with resetable fuses (PTCs). The PTCs increase resistance several orders of magnitude when over-currents exceed safe levels. A normal state resumes when overcurrents are removed. The ability to selfrestore in this manner significantly increases suppressor performance and survivability. The Model 105 mounts onto a standard 35mm industrial din rail. There are three “Field Side” and three “Electronics Side” screw terminals. One is reserved for a shield. Three electrically tied ground terminals are provided for grounding the Model 105 unit to Building-Approved Ground. Shield is isolated from ground. Two (2) terminal versions without a shield connection are also available. Operating Voltage 6, 12, 24, 30, 35 VDC Clamping Voltage 8, 15, 30, 36, 43 VDC Operating Current 0.15 A Max Current Ip (Occurrences) 10 kA (8x20µs) >100 (10x1000µs) Typical Capacitance 1500pf Nominal Series Resistance Response Time Operating Temperature • Voltage: 0-170 VDC • Current: 150 mA • Connection: Hardwire/Terminals - accepts up to 12 AWG • Mounting: DIN - 35mm *See Ordering Information for model number selection Features • Low-voltage data surge protection • Three-stage hybrid protection General Technical Specifications Peak Surge Current Key Specs • Sneak/fault current protection with resettable fuses (PTCs) • Low profile packaging • Easy installation • Fits standard 35mm DIN-Rail 5Ω < 1 nanosecond -40°C to 85°C Certifications UL 497B Warranty 5 years Certifications • UL 497B 105D200S08KAN3D0 Special Features Operating Voltage 170 VDC Clamping Voltage 200 VDC Operating Current 5 Amp Max Current Ip (Occurrences) Total Peak Surge Current Rating >10 (10x1000µs) 8 kA (8x20µs) Nominal Series Resistance None Caution Do not place this product in service on any signal line capable of continuously supplying more than 150 mA. Attention Ne pas placer ce produit dans le service sur une ligne de signal capable de fournir en permanence plus de 150 mA. V DANGER! Only qualified personnel should install or service this system. Electrical safety pre-cautions must be followed when installing or servicing this equipment. To prevent risk of electrical shock, turn off and lock out all power sources to the unit before making electrical connections or servicing. Seulement le personnel qualifié doit installer ou maintenir ce systéme. Des précautions de sécurité en électricité doivent être suivis lors de l’installation ou de la maintenance de cet equipement. Pour eviter tout risque de choc électrique, débranchez et verouiller toutes les sources d’alimentation de cet equipement avant de. Installation Instructions 3-TERMINAL DEVICE 2-TERMINAL DEVICE 2.35” [59.7] 2.35” [59.7] Field Side (Line) 2.95” [74.9] 2.25” [57.2] 2.25” [57.2] Line Line Line Line Shield 2.95” [74.9] Field Side (Line) Protected Equipment Side (Load) 1.1” [27.9] 0.8” [20.3] Protected Equipment Side (Load) Ground Wire Size Range = 22-12 AWG Terminal Torque Rating = 0.8 Nm (7 in-lb) Read and Understand These Instructions These protectors are intended for indoor use on communication loop circuits which have been isolated from the Public Switch Telephone Network. The communication loop circuits shall not be exposed to accidental contact with the electric light or power conductors. The protectors shall be installed per the applicable requirements of the National Electric Code, ANSI/NFPA 70. 1.1” [27.9] 0.49” [12.4] Ground Ordering Information MODEL Former Model Name APPLICATION 105D008S10KAN3D0 0-8 VDC 105D015S10KAN3D0 0-15 VDC 105D030S10KAN3D0 0-30 VDC 105D036S10KAN3D0 0-36 VDC 105D043S10KAN3D0 0-43 VDC 105D200S08KAN3D0 0-200 VDC Edco DRS-008 Edco DRS-015 Edco DRS-030 Edco DRS-036 Edco DRS-043 Edco DRS-130RMS 105xxxxxxxxxN2xx Edco DRS-XXX-2 2 Terminal Version without shield 14550 58th Street North Clearwater, Florida 33760 P (800) 237-4567 P (727) 535-6339 F (727) 539-8955 E [email protected] While every precaution has been taken to ensure accuracy and completeness herein, ASCO Power Technologies assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifications are subject to change without notice. ID-50133 Rev- 07-16