ASCO Model 142 Installation Manual
Transcription
ASCO Model 142 Installation Manual
Series 100 Model 142 (Edco SRA64 Series) 1 Pair Data/Signal Surge Protective Device Technical Documentation The ASCO Model 142 surge suppressor is a single pair cube implementing three-stage hybrid technology. This cube addresses over voltage transients with gas tubes and silicon avalanche components. In addition, sneak and fault currents are mitigated with resettable fuses (PTCs). The PTCs increase resistance several orders of magnitude when overcurrents exceed safe levels. A normal state resumes when over-currents are removed. The ability to self restore in this manner significantly increases suppressor performance and survivability. The standard Model 142 second stage clamps are placed from each signal line-to ground. In certain cases, where ground potentials vary from site-to-site, a line-toline only second stage clamp may be preferred. This variation uses an “X” in position 12 of the model number. In other cases, line-to-line and line-to-ground second stage clamps may be preferred. This variation uses an “X” in position 12 of the part number. A variety of clamping voltages are available as standard. Reference the “Ordering Information” section to insure that a complete part number and description is obtained. Operating Voltage 5, 12, 24, 30, 36, 52, or 120 VDC Clamping Voltage 8, 15, 30, 36, 43, 60, or 150 VDC Operating Current 0.15 A 10 kA (8 x 20 μs) SPD Technology GDT, SAD, w/ Series PTC Response Time < 1 nanosecond Resistance 5Ω (typical) Operating Temperature -40°C to+85°C Dimensions (in / mm) 1.15˝ [29.2 mm] Cube Weight (oz / kg) 2 oz [.06 kg] Mounting Stud (standard) • Voltage: 0-120 VDC • Current: 150 mA • Connection: Wire Leads (provided) and 10-32 Ground Stud • Mounting: 10-32 x 1/2” Ground Stud *See Ordering Information for model number selection Features • Lightning protection for balanced low voltage signal lines • Three stage hybrid protection General Technical Specifications Peak Surge Current Key Specs No.10-32 x 1/2˝ [12.7 mm] Warranty 5 years Caution Do not place this product in service on any signal line capable of continuously supplying more than 150 mA. Attention Ne pas placer ce produit dans le service sur une ligne de signal capable de fournir en permanence plus de 150 mA. V DANGER! Only qualified personnel should install or service this system. Electrical safety pre-cautions must be followed when installing or servicing this equipment. To prevent risk of electrical shock, turn off and lock out all power sources to the unit before making electrical connections or servicing. Seulement le personnel qualifié doit installer ou maintenir ce systéme. Des précautions de sécurité en électricité doivent être suivis lors de l’installation ou de la maintenance de cet equipement. Pour eviter tout risque de choc électrique, débranchez et verouiller toutes les sources d’alimentation de cet equipement avant de. • Sneak/fault current protection • Differential and common mode protection • Automatic recovery • Fast response time • Flame retardant epoxy encapsulated • 5 year warranty Wiring Assignments UNPROTECTED PROTECTED Black White FIELD SIDE ELECTRONICS SIDE (Outside Plant) (Equipment) Black/Red White/Red Ordering Information MODEL Former Model Name OPERATING VOLTAGE CLAMPING VOLTAGE 142D008S10KAG4N0 5 VDC 8 VDC 142D015S10KAG4N0 12 VDC 15 VDC 142D030S10KAG4N0 24 VDC 30 VDC 142D036S10KAG4N0 30 VDC 36 VDC 142D043S10KAG4N0 36 VDC 43 VDC 142D060S10KAG4N0 52 VDC 60 VDC 142D150S10KAG4N0 120 VDC *150 VDC Edco SRA64C-008 Edco SRA64C-015 Edco SRA64C-030 Edco SRA64C-036 Edco SRA64C-043 Edco SRA64C-060 Edco SRA64C-150 NOTE: Each Signal Line-to-Ground Protection (Standard) *Not UL Listed For Line-to-Line Protection only, use a “D” in the 12th position of the model number. For Line-to-Ground and Line-to-Line Protection, use a “X” in the 12th position of the model number. 14550 58th Street North Clearwater, Florida 33760 P (800) 237-4567 P (727) 535-6339 F (727) 539-8955 E [email protected] While every precaution has been taken to ensure accuracy and completeness herein, ASCO Power Technologies assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifications are subject to change without notice. ID-50125 Rev- 07-16