Sheet D Imperial Working Drawing Template

Transcription

Sheet D Imperial Working Drawing Template
Note: Contractor to supply and install hollow metal post,
concealed to new partial height partition at the floor
ramp. Posts are to be fastened to the concrete slab at
end and middle to ensure stability of partition. Shop
drawings are to be issued for Designer approval
Corner Bead (Typical)
U/S of existing concrete slab
Acoustical caulk
2 1/2" metal studs @ 16" o.c. c/w 1/2"
gypsum board both sides. Tape, fill &
sand smooth ready for paint or other
finish.
CORPORATE SERVICES
REAL PROPERTY ASSET MANAGEMENT
DESIGN & CONSTRUCTION
Acoustical caulk
Paint grade
hollow metal
frame. Painted
P3.
Paint grade hollow
metal frame.
Painted P3.
2 1/2" metal studs @ 16" o.c. c/w 1/2"
gypsum board both sides. Tape, fill &
sand smooth ready for paint or other
finish.
Metal runner
Blocking as
required
KENT KIRKPATRICK GENERAL MANAGER / DIRECTEUR GENERAL
S.A. FINNAMORE, O.A.A. DIRECTOR / DIRECTEUR, O.A.O.
ROBERT VAILLANCOURT, O.A.A. MANAGER / GESTIONNAIRE, O.A.O.
FOR / POUR
2 1/2" sound attenuation batts suitable
for metal stud application
Solid core - paint
grade door. Painted
P3.
DEPARTMENT OF CORPORATE SERVICES / SERVICES GENERAUX
REAL PROPERTY ASSET MANAGEMENT BRANCH /
DIRECTION DE LA GESTION DES ACTIFS ET DES BIENS IMMOBILIERS
DESIGN AND CONSTRUCTION DIVISION /
DIVISION DE LA CONCEPTION ET DE LA CONSTRUCTION
2 1/2" sound attenuation batts suitable for metal
stud application
Baseboard as applicable
1 5/8" solid
core paint
grade door.
Painted P3.
Line of existing concrete ramp beyond.
Metal runner (Typical)
Belfast Road
Acoustical caulk
Line of finished floor as applicable
St-Laurent Boulevard
1 Door Type 'A'
ID05 Scale: 1/2" =1' - 0"
2 Section at Door Type
'A'
ID05 Scale: 3" =1' - 0"
Line of existing concrete slab
5
4
Baseboard as applicable
Line of finished floor
Heavy duty
hinge
3
ISSUED FOR TENDER
2010/08/24
EP
2
99% CLIENT REVIEW
2010/08/10
EP
99% CLIENT REVIEW
2010/08/06
EP
MILESTONE / FAIT SAILLANT
(Y/M/D)
DATE:
(A/M/J)
INITIALS
INITIALES
1
Blocking as
required
1 5/8" solid core
paint grade
door
6
Paint grade
hollow metal
frame
3 Section at Door Type 'A'
ID05 Scale: 3" =1' - 0"
H1:
Passage Lever Set
Heavy duty commercial grade hinges, 1 12" pair per door
Floor surface mounted door stop suitable for Epoxy file
Clear silicone door silencers
Finish to match existing building standard
H2
Lever Lock Set
Heavy duty commercial grade hinges, 1 12" pair per door
Floor surface mounted door stop suitable for Epoxy file
Clear silicone door silencers
Surface mounted door closer
Finish to match existing building standard
1. Contractor to paint door and frames on contract side only.
2. Contractor to paint both sides of door and frames.
NUMBER/
NUMÉRO
5 Partial Height Partition - W1
ID05 Scale: 6" =1' - 0"
6 Interior Tenant Partition - W2
ID05 Scale: 6" =1' - 0"
EP
EP
MD
As Noted
DETAIL NUMBER
1 DRAWING TITLE
A1.1 SCALE:
SHEET NUMBER
U/S of existing concrete slab
Acoustical caulk
Existing base building core partition.
U/S of existing concrete slab
Acoustical caulk
THIS DRAWING IS THE PROPERTY OF
THE CITY OF OTTAWA AND ALL
COPYRIGHT IS RESERVED.
DIMENSIONS ON DRAWING ARE FOR
ESTIMATING PURPOSES ONLY. IT IS
THE RESPONSIBLITY OF EACH
CONTRACTOR AND SUB-CONTRACTOR
OR CONSULTANT TO CHECK AND
VERIFY ALL DIMENSIONS AND
CONDITIONS ON SITE. NOTIFY OWNER
OF ANY ERRORS OR OMISSIONS PROIR
TO COMMENCING THE WORK. DO NOT
SCALE THE DRAWINGS.
CE DESSIN CONSTITUE LA PROPRIÉTÉ
DE LA VILLE D'OTTAWA ET TOUT DROIT
D'AUTEUR EST RÉSERVÉ. LES
DIMENSIONS UTILISÉES LE SONT À DES
FINS D'ESTIMATION SEULEMENT. IL
INCOMBE À CHAQUE ENTREPRENEUR,
SOUS-CONTRACTANT OU CONSULTANT
DE VÉRIFIER TOUTES LES DIMENSIONS
ET LES CONDITIONS SUR LE CHANTIER.
VEUILLEZ INFORMER LE PROPRIÉTAIRE
DE TOUTE ERREUR OU OMISSION
AVANT D'ENTAMER LES TRAVAUX. NE
DRESSEZ PAS LES PLANS À L'ÉCHELLE.
Existing base building core partition.
ARCHITECT / ARCHITECTE
CONSULTANT / EXPERT-CONSEIL
O
A
RID
1 1/2" metal studs @ 16" o.c. c/w 1/2" gypsum
board on one sides. Tape, fill & sand smooth
ready for paint or other finish.
CONSULTANT / EXPERT-CONSEIL
Existing metal stud
application to remain.
Typical.
Contractor to supply and
installed 1 2" GWB to existing
metal stud application.
Finished to receive paint.
Typical.
Existing concrete block
and wall and concrete
beam to remain.
CONSULTANT / EXPERT-CONSEIL
1 layer of 1/2" gypsum board to u/s
of slab
New fluorescent light fixture.
Refer to Reflected Ceiling Plan
ID03.
Contractor to supply and
installed 12" plywood finished
with L2. Typical.
Align
PROJECT / LOCATION / PROJET / ENDROIT
Baseboard as applicable
Baseboard as applicable
OC TRANSPO - ANNEX
Acoustical caulk
Acoustical caulk
SECOND FLOOR - SOUTH
GARAGE
Line of finished floor as applicable
OTTAWA, ONTARIO
Line of finished floor as applicable
DRAWING / DESSIN
Line of existing concrete slab
4 Section at Bulkhead
ID05 Scale: 6" =1' - 0"
7 Interior Tenant Partition - W3
ID05 Scale: 6" =1' - 0"
DOOR SCHEDULE AND
ELEVATIONS, DOOR SECTIONS
PARTITION SECTIONS AND
CEILING SECTION
8 Interior Tenant Partition - W4
ID05 Scale: 6" =1' - 0"
FACILITY NO. / NO. DE INSTALLTIONS
04256-0206
PROJECT NO. / PROJET NO.
10048
SHEET NO. / FEUILLE No.
ID05