DND French Border Layout

Transcription

DND French Border Layout
Gouvernement Government
du Canada
of Canada
GYPSUM BOARD (16mm - 5/8") ON METAL STUDS
NOTES AND DETAILS OF TYPICAL PARTITION JUNCTIONS FOR PARTITION THAT ARE SEALED AND INSULATED OR SEALED ONLY
GENERAL NOTES
ASSEMBLAGE MURAL / WALL ASSEMBLY
CONSTRUCTION
CONSTRUCTION
DESCRIPTION
DESCRIPTION
FIRE RATING
This design is an instrument of service and is protected by copyright, copyright for the consultant's
instrument of service belongs to the consultant. Copies including electronic copies, may only be used
for the purpose intended and for a one-time use, on the same site, and for the same project and may
not be offered for sale or transfer without the express written consent of the consultant.
1)
DETAILS NOTES
- 1 GYPSE TYPE X, 16mm
96
01
01
- 1 GYPSE TYPE X, 16mm
- 1 TYPE X GYPSUM BOARD, 16mm
- METAL STUD 64mm @ 406mm c/c
- 1 TYPE X GYPSUM BOARD, 16mm
FIRE-RATED, WHERE REQUIRED
SEALED
FILL CAVITY WITH SEALANT (SEE GENERAL NOTES)
02 RUBAN ET COMPOSE A JOINT
TAPE AND JOINT COMPOUND
03
METAL MOLDING (SUCH AS CGC # 200B OR D-200 BY BAILEY)
AND JOINT COMPOUND
- 1 GYPSE TYPE X, 16mm
04
10 VISSER LES PLANCHES DE GYPSE SUR MONTANTS VERTICAUX
SEULEMENT
SCREW GYPSUM BOARDS ON VERTICAL STUDS ONLY
BOITE
DE JONCTION, PRISE (NE PAS INSTALLER LES BOITES DOS
11
SCELLANT ACOUSTIQUE.
OUTLET OR JUNCTION BOX (DO NO INSTALL BOXES BACK TO BACK IN
SAME STUD SPACE)
12
MODEL 093 BY CGC OR EQUIVALENT
METAL STUD FASTENED TO WALL OR COLUMN
01A
- 1 GYPSE TYPE X, 16mm
13
VAR.
05
-1 TYPE X GYPSUM BOARD, 16mm
-2 ROWS, METAL STUD 92mm @ 406mm c/c
-1 TYPE X GYPSUM BOARD, 16mm
WIDTH TO MATCH EXISTING WALL
FIRE-RATED, WHERE REQUIRED
SEALED
GYPSUM BOARD ON METAL FURRING
MUR
OU COLONNE
06
WALL OR COLUMN
07 CORDON CONTINU DE SCELLANT, AVANT L'INSTALLATION DU GYPSE
CONTINUOUS SEALANT BEAD, BEFORE APPLYING THE GYPSUM BOARD
WHEN FIRE-RATING ARE REQUIRED, EXECUTE PARTITION SEALING AS SHOWN ON TYPICAL DETAILS, USING AN APPROVED SMOKE AND FIRE SEALANT.
14
RESILIENT BARS
- 1 GYPSE TYPE X, 16mm
VAR.
09
FIRE-RATED, WHERE REQUIRED
SEALED
-1 TYPE X GYPSUM BOARD, 16mm
-2 ROWS, METAL STUD 64mm @ 406mm c/c
-1 TYPE X GYPSUM BOARD, 16mm
WIDTH TO MATCH EXISTING WALL
2)
WHEN ACOUSTICAL INSULATION IS REQUIRED IN WALL PARTITION, INSULATION THICKNESS MUST EQUAL TO THE STUD WIDTH.
15
3)
STRUCTURAL CONCRETE SLAB OR CONCRETE SLAB ON STEEL DECK
(ANTICIPATED DEFLECTION 25MM).
01B
USE AN ACOUSTICAL SEALANT FOR SOUND-PROOFING UNRATED PARTITIONS. FOR TYPES OF SEALANTS, REFER TO SPECIFICATIONS.
CONTINUOUS SELF-ADHESIVE BAND, 12mm WIDTH BY 3mm THICKNESS
08
- 1 GYPSE TYPE X, 16mm
WHEN SOUND PROOFING AND FIRE-RATING ARE REQUIRED, EXECUTE PARTITION SEALING AS SHOWN ON
TYPICAL DETAILS AND COMPLY WITH CAN/ULC-S115, USING AN APPROVED SMOKE AND FIRE SEALANT; THIS REQUIREMENT ALSO APPLY TO UNRATED FIRE
SEPARATIONS
FLOOR OR CEILING STEEL TRACK FASTENED TO SLAB (PROVIDE A GAP
BETWEEN VERTICAL STUDS & CEILING TRACK, FOR FLOOR
DEFLECTION OF 25 MM).
TYPICAL JUNCTIONS DETAILS MUST BE FOLLOWED ALSO FOR PARTITIONS NOT REQUIRING ACOUSTICAL AND FIRE-RATING.
LORSQUE L'IGNIFUGATION N'EST PAS REQUISE.
INSTALL AN APPROVED SMOKE/ FIRE-PROOFING SYSTEM BETWEEN
TOP RIBS OF STEEL DECK & CEILING TRACK. SEAL AT JUNCTION OF
GYPSUM AND LOWER RIBS. FOR NON-RATED PARTITIONS, RETAIN
GLASS FIBER PACKING BETWEEN FLUTES OF STEEL DECK.
4)
REFER TO SPECIFICATIONS AND TO MANUFACTURER'S INSTRUCTIONS FOR STUD GAUGE AND MAXIMUM HEIGHT .
5)
SOUFFLAGE DE GYPSE
55
-1 GYPSE, 16 mm
02
-
FOR ALL SPECIFIED WALL TYPES, REPLACE SURFACE LAYER OF GYPSUM BOARD (13mm-1/2" OR 16mm-5/8") BY A WATER RESISTANT PANEL AS SPECIFIED, FOR
WATER CLOSETS, WASHROOMS, JANITOR ROOMS, LOCKER ROOMS OR ANY OTHER HUMID SPACE, EXCEPT FOR FIRE-RATED WALLS IN WHICH THE WATER
RESISTANT PANEL IS ADDED TO THE ASSEMBLY.
@ 400mm c/c
- 1 GYPSUM BOARD, 16 mm
- PLYWOOD, 16mm
- METAL FURRING (HORIZONTAL) 22mm @ 400mm c/c
TYPICAL JUNCTION DETAILS
ALSO REPLACE SURFACE LAYER OF GYPSUM BOARD BY A CEMENT BOARD PANEL OR A FIBER-REINFORCED GYPSUM PANEL,(REFER TO SPECIFICATIONS) AROUND
BATHS, SHOWERS AND ANYWHERE THE WALL FINISH IS TO RECEIVE TILING, EXCEPT FOR FIRE-RATED WALLS IN WHICH THESE SUPPORT PANEL ARE ADDED TO THE
ASSEMBLY.
- 1 GYPSE TYPE X, 16mm
6)
POURSUIVRE LES GYPSES DE 100mm AU-DESSUS DU NIVEAU DU PLAFOND ADJACENT LE PLUS HAUT.
- ISOALNT, 1`52mm
- 1 GYPSE TYPE X, 16mm
203
03
ALL INTERIOR WALLS WITH FIRE AND / OR SOUND REQUIREMENTS ARE BUILT FLOOR SLAB TO CEILING
SLAB. FOR ALL OTHER PARTITION, UNLESS OTHERWISE NOTED, EXTEND GYPSUM BOARD 100mm ABOVE
CEILING LEVEL.
FIRE-RATED, WHERE REQUIRED
SEALED
-1 TYPE X GYPSUM BOARD, 16mm
- PLYWOOD, 19mm
- METAL STUD 152mm, 20 GA, @ 305mm c/c
- INSULATION, 152mm
- 1 TYPE X GYPSUM BOARD, 16mm
7)
UNLESS OTHERWISE NOTED, WHERE PARTITIONS ARE DIMENSIONED IN THEIR CENTER, IT IS THE CENTER OF THEIR TOTAL WIDTH AND NOT THE CENTER OF THE
METAL STUD. CONTRACTOR MUST VERIFY THE EXACT LOCATION OF THE PARTITION ON SITE WITH RESPECT TO ITS TOTAL WIDTH INSTEAD OF METAL STUD CENTER.
ALSO, UNLESS OTHERWISE INDICATED, ASYMMETRICAL WALL TYPES MUST BE BUILT WITH MAJORITY OF GYPSUM BOARD AND/OR RESILIENT CHANNEL ON PUBLIC
SIDE.
SOUFFLAGE DE GYPSE
04
124
-1 GYPSE, 16 mm
8)
-
DIRECTION QUE CE SOIT.
PROVIDE EXPANSION JOINTS IN GYPSUM PARTITIONS @ 9m MAXIMUM, IN BOTH DIRECTIONS.
- 1 GYPSUM BOARD, 16 mm
- PLYWOOD, 16mm
- METAL STUD 92mm @ 400mm C/C
9)
PROVIDE BACKING WHEREVER HEAVY ELEMENTS ARE FIXED TO THE WALL : HANDRAILS, HIGH CABINETS,
SINK, SUSPENDED COUNTER OR ANY OTHER ELEMENT REQUIRING BACKING .
10 )
000 X
TYPE DE CLOISON
WALL TYPE
CLOISONS:
HAUTEUR CLOISON
WALL HEIGHT
A : CLOISON PLEINE HAUTEUR JUSQU'AU DESSOUS DE
LA DALLE, POUTRES, SOLIVES DE PLANCHER OU
FERMES DE TOIT
00
INSTALL FIRE RESISTANT SEALANTS TO PERIMETER OF ALL WALLS FIRE SEPARATIONS.
PARTITIONS:
11 )
A : FULL HEIGHT WALL - FROM FLOOR TO UNDERSIDE OF
SLAB, BEAM, JOIST OR ROOF JOIST ABOVE
AT THE JUNCTION BETWEEN A PARTITION WITH NO FIRE-RATED DEGREE AND A WALL WITH A FIRE RESISTANCE A DEGREE, GYPSUM BOARDS OF THE FIRE-RATED
PARTITION MUST TO BE CONTINUOUS.
12 )
B : WALL - FROM FINISHED FLOOR TO 100MM ABOVE
FINISHED CEILING.
REQUISE (EN MINUTES)
FIRE-RATING REQUIRED
(IN MINUTES)
SUPPORT EN BOIS EXISTANT).
UNLESS OTHERWISE NOTED, ALL DOOR FRAMES WILL BE INSTALLED AT A MINIMUM DISTANCE OF 100mm FROM THE PERPENDICULAR ADJACENT WALL (HINGE SIDE
DIMENSION, INCLUDING FRAME).
C : WALL INSIDE AND EXISTING OPENING
13 )
HAUT QUE LE PLAFOND FINI.
C: CLOISON DANS OUVERTURE EXISTANTE
UNLESS OTHERWISE NOTED, ALL GRIDS OF SUSPENDED ACOUSTICAL CEILING TILES ARE CENTERED IN BOTH DIRECTIONS OF THE ROOM
E: WALL, FROM EXISTING FLOOR TO THE UNDERSIDE OF
NEW SLAB OR FLOOR NEW FLOOR SUPPORT ABOVE.
F : HEIGHT AS REQUIRED OR AS INDICATED
GYPSUM PARTITION - MASONRY PARTITION CONNECTION
00
JUSQU'AU DESSOUS DE LA NOUVELLE DALLE OU DU
NOUVEAU SUPPORT DE PLANCHER AU DESSUS.
NO.
P.P.
DATE
APPR.
REVISION
EMPLACEMENT | LOCATION
PROJET | PROJECT
DATE
SUJET | SUBJECT
CLOISONS TYPES |
PARTITION TYPES
NO. OTP | WBS NO.
NO. DESSIN | DWG. NO.
Canada
Plan 2 de 11