Current Protector Type E-1078-4.2 for low
Transcription
Current Protector Type E-1078-4.2 for low
Circuit Protection & Control Current Protector Type E-1078-4.2 for low-voltage halogen lighting systems Eliminating fire hazard Technical Information. Current Protector Type E-1078-4.2 (e.g. by overloads or short-circuit), the Protector will immediately disconnect the system. Underload (e.g. through poor terminal connections) will also cause system disconnection. Fault conditions are indicated by the integral LED. The system can be re-set by turning the switch of the lighting circuit off and then on again once the cause of the failure has been remedied. 30 1.18 Technical Data E-1078-422 / - 432 / -482 Lamp load short-circuit, overload, underload 60 ... 300 W (AC 230 V only) 100 ... 300 W (AC 120 V only) 100 ... 400 W (AC 230 V only) 300 ... 600 W (AC 230 V only) NV-STROMWÄCHTER STROMWÄCHTER R 1078-422 AC 230V 100-400W NV-Stromwächter Überwacht die eingestellte Leistung auf Über- und Unterlast 68 2.68 Protective function Einstellungshinweise: Mit der Speicher-Taste (5 sec drücken) wird die zu überwachende Leistung eingestellt. (Dimmer auf Maximum drehen). Bei Fehler-Signal zuerst Störung beheben. Anschlussklemmen: 2(N) und 3(L) Netzanschluss 1(Tr) und 4(Tr) Trafo-Primärseite CURRENT PROTECTOR 1 Tr Fehler Error 2 N 3 L Einbau und Montage Achtung! dürfen nur durch eine Elektrofachkraft erfolgen. Maximale Leistung des Trafos beachten! 4 Tr Speichern Setting Zulassungen: Monitoring window typically ±40 W Response times typ. overload 200 ms...2 s (depending on overload) short-circuit 200 ms underload 3s Voltage rating AC 230 V ±10 %, 50 Hz AC 120 V ±10 %, 60 Hz Current rating relay contact 8 A Dimmer operation between 35 and 100% of the rated load stored Temperature range 0 ... +60 °C Housing surface mounted type Connection screw terminals 54 2.13 line and contact resistance (underload) which may often cause dangerous overheating. E-T-A type E1078-4.2 monitors the primary current of lowvoltage transformers for halogen fittings. Upon installation of the system, the admissible current range can be stored by operating the storage button (with type E-1078-482-... by means of the light switch). If the admissible range is exceeded 40 1.57 60 2.36 Protection against short circuits Protection against overloads Protection against terminal overheating through increased contact resistance. The E-T-A current protector type E1078–4.2 is a load-dependent device designed to protect low-voltage lighting systems against conductor faults and overloads. The Protector also detects a creeping increase of ● ● ● 8319 1.5 .059 45 1.77 57 2.24 22.5 .886 light switch (dimmer) low-voltage transformer AC 230 V 2/N VDE approval Reg. No. 8319 to VDE 0160 UL-approval 120 V AC, 300 W, 60 Hz, to UL 1077 1/Tr 3/L 4/Tr low-voltage system AC 12 V error red Electronics storage button (N/A with type 1078-482-…) current protector Features ● ● ● ● ● LED fault indication suitable for use with dimmers passive relay for long use resettable with light switch unaffected by in-rush currents Circuit Protection & Control F-E-1078-4.2 e (06/02) E-T-A Elektrotechnische Apparate GmbH D-90518 Altdorf . Industriestraße 2-8 Tel. +49 (0 91 87)10-0 . Fax +49 (0 91 87)10-397 E-Mail: [email protected] . www.e-t-a.com