Current Protector Type E-1078-4.2 for low

Transcription

Current Protector Type E-1078-4.2 for low
Circuit Protection & Control
Current Protector Type E-1078-4.2
for low-voltage halogen lighting systems
Eliminating fire hazard
Technical Information.
Current Protector Type E-1078-4.2
(e.g. by overloads or short-circuit), the
Protector will immediately disconnect
the system. Underload (e.g. through
poor terminal connections) will also
cause system disconnection.
Fault conditions are indicated by the
integral LED. The system can be
re-set by turning the switch of the
lighting circuit off and then on again
once the cause of the failure has been
remedied.
30
1.18
Technical Data E-1078-422 / - 432 / -482
Lamp load
short-circuit, overload, underload
60 ... 300 W (AC 230 V only)
100 ... 300 W (AC 120 V only)
100 ... 400 W (AC 230 V only)
300 ... 600 W (AC 230 V only)
NV-STROMWÄCHTER
STROMWÄCHTER
R
1078-422 AC 230V 100-400W
NV-Stromwächter
Überwacht die eingestellte Leistung
auf Über- und Unterlast
68
2.68
Protective function
Einstellungshinweise:
Mit der Speicher-Taste (5 sec drücken)
wird die zu überwachende Leistung
eingestellt. (Dimmer auf Maximum
drehen). Bei Fehler-Signal zuerst
Störung beheben.
Anschlussklemmen:
2(N) und 3(L) Netzanschluss
1(Tr) und 4(Tr) Trafo-Primärseite
CURRENT
PROTECTOR
1
Tr
Fehler
Error
2
N
3
L
Einbau und Montage
Achtung!
dürfen nur durch eine
Elektrofachkraft erfolgen.
Maximale Leistung des Trafos beachten!
4
Tr
Speichern
Setting
Zulassungen:
Monitoring window
typically ±40 W
Response times typ.
overload 200 ms...2 s (depending on overload)
short-circuit 200 ms
underload
3s
Voltage rating
AC 230 V ±10 %, 50 Hz
AC 120 V ±10 %, 60 Hz
Current rating
relay contact 8 A
Dimmer operation
between 35 and 100% of the rated load stored
Temperature range
0 ... +60 °C
Housing
surface mounted type
Connection
screw terminals
54
2.13
line and contact resistance (underload)
which may often cause dangerous
overheating. E-T-A type E1078-4.2
monitors the primary current of lowvoltage transformers for halogen
fittings. Upon installation of the
system, the admissible current range
can be stored by operating the storage
button (with type E-1078-482-...
by means of the light switch). If
the admissible range is exceeded
40
1.57
60
2.36
Protection against short circuits
Protection against overloads
Protection against terminal
overheating through increased
contact resistance.
The E-T-A current protector type
E1078–4.2 is a load-dependent
device designed to protect low-voltage
lighting systems against conductor
faults and overloads. The Protector
also detects a creeping increase of
●
●
●
8319
1.5
.059
45
1.77
57
2.24
22.5
.886
light switch (dimmer)
low-voltage transformer
AC 230 V
2/N
VDE approval
Reg. No. 8319 to VDE 0160
UL-approval
120 V AC, 300 W, 60 Hz, to UL 1077
1/Tr
3/L
4/Tr
low-voltage system
AC 12 V
error red
Electronics
storage button
(N/A with
type 1078-482-…)
current protector
Features
●
●
●
●
●
LED fault indication
suitable for use with dimmers
passive relay for long use
resettable with light switch
unaffected by in-rush currents
Circuit Protection & Control
F-E-1078-4.2 e (06/02)