Radiometer/Photometer
Transcription
Radiometer/Photometer
TECHNICAL DATE SHEET Produit POLLUX Référence DFTA072B-E Date 01/04/2009 Page 1/3 Radiometer/Photometer POLLUX is a radiometer/Photometer which simultaneously measures the ultraviolet (UV-A) irradiance and the visible light illuminance. POLLUX is fitted with a n intelligent processing system of measurement. This is a smoothed average in time coupled to an algorithm of the measurement control. This permanently checks that the readingon the display corresponds well to the instantaneous value that can be detected by the sensor. If a shift due to the integration in time is detected, the table of the smoothed average is automatically erased. Display is then temporary ( less than 0.5 second) fluctuating, then very quickly the average is rebuilt ensuring a good stability. POLLUX complies with the CE marking which is applicable to this type of meter in the Industry. Description of the differents elements POLLUX is designed to be easy to use and is the lightest as possible. A reinforced ABS plastic casing makes it extremely robust the meter. A cover gives easily access to the 9 Volts dry cell. The polarity of the the dry cell is automatically detected. Sensor Sensor is located in a separate case and conneted to the meter by a 1 meter long cord. This single sensor allows to measure visible light and ultraviolet (UV-A) light. Serial number of the meter Indicator of the level of the dry cell Date of the last calibration Visible light measurement UV-A light measurement All specifications are subject to change without notice. SREM Technologies – SA au capital de 270 000 € – RCS LE MANS B 394 727226 – SIRET 00026 – TVA FR64394727226 ZI Ouest – Rue des Frères Chappe – 72200 LA FLECHE – France - Tél 33 2.43.48.15.10 – Fax 33 2.43.45.25.26 TECHNICAL DATE SHEET Produit POLLUX Référence DFTA072B-E Date 01/04/2009 Page 2/3 Technical data Characteristics of detection • • Sensor : Units of measurement : • Ranges : • Résolutions : Silicium sensor balanced by filters Visible light : lux (lux) UV-A light : µWatt per square meter (µW/cm²) Visible light : 0.1 lux to 6,000 lux UV-A light : 0.1 µW/cm² to 20,000 µW/cm² Visible light : 0,1 lux UV-A : 1 µW/cm² Mechanical and environmental characteristics • Dimensions : • • • Weight : Boîtier : Humidity & Dust tightness : Dimensions of the meter : 120 mm x 65 mm x 22 mm (not included) Dimensions of the sensor : 85 mm x 45 mm x 16 mm 200 g with dry cell Casing : Reinforced plastic ABS IP 64 The first figure represents the tightness to solids: 6 for the total protection against dust. The second figure represents the water tightness: 4 for the protection against water spattering Electrical Characteristics • • • • • Electromagnetic compatibility : conform to EN 61326 Ed.97 + A1 Ed.98 + A2 Ed.01 Conform to : EN 61326 Ed.97 + A1 Ed.98 + A2 Ed.01 Power : Dry cell 9 V (PP3/ 6F22 / 6LR61) Consumption : 17 mA Operating time : 30 hours (without backlight) AFTER- SALES Service If required do not hesitate to contact the SREM After-sales Service for any required further information. Tel : + 33 (0) 2.43.48.15.10 Fax: + 33 (0) 2.43.45.25.26 www.srem.fr All specifications are subject to change without notice. SREM Technologies – SA au capital de 270 000 € – RCS LE MANS B 394 727226 – SIRET 00026 – TVA FR64394727226 ZI Ouest – Rue des Frères Chappe – 72200 LA FLECHE – France - Tél 33 2.43.48.15.10 – Fax 33 2.43.45.25.26 TECHNICAL DATE SHEET Produit POLLUX Référence DFTA072B-E Date 01/04/2009 Page 3/3 Visible light 1,20 1,00 0,80 0,60 0,40 0,20 0,00 380 400 420 440 460 480 500 520 540 560 580 600 620 640 660 680 700 720 740 760 780 -0,20 -0,40 -0,60 nm Pollux Réponse de l'oeil UV-A light 1,2 1,1 1 0,9 0,8 0,7 0,6 0,5 0,4 0,3 0,2 0,1 0 290 300 310 320 330 340 350 360 370 380 390 400 410 nm Pollux All specifications are subject to change without notice. SREM Technologies – SA au capital de 270 000 € – RCS LE MANS B 394 727226 – SIRET 00026 – TVA FR64394727226 ZI Ouest – Rue des Frères Chappe – 72200 LA FLECHE – France - Tél 33 2.43.48.15.10 – Fax 33 2.43.45.25.26