05-1941-BW-82U - Leds-C4
Transcription
05-1941-BW-82U - Leds-C4
HALL 05-1941-BW-82U IN Design by Natrang design TECHNICAL CHARACTERISTICS Type: Wall fixture Adjustable: Adjustable from 0º to 90º on the horizontal axis IP Protection degrees: IP20 Location: DRY Light source 1: 1 x E26 MAX 60W Light source 2: 1 x LED Cree 3W Warm White - 3000K 100 lm(N) CRI 80 Voltage / Frequency: 120V/60Hz Warranty (Years): 2 Option to extend the guarantee (Years): 5 Units per box: 4 Pes net (lb): 1.86 EAN: 8435381431174 The photograph may not match the reference exactly. Please read the product description to identify the finish. Download photometric file .ldt /.ies MATERIALS / FINISHES Structure material: Aluminium Structure finish: Matt white Lm(N): Nominal flow of light in actual working conditions. Its actual flow will depend on the environmental conditions and the efficiency of the optics and/or diffuser. LEDS-C4 reserves the right to make the necessary technical changes they deem adequate, in order to improve the features of the product. Please consult the sales team to clarify any doubt. (+34) 973 468 100 [email protected] www.leds-c4.com OPTIONAL ACCESORIES PAN-194-AJ Shade,grey, Ø220mm Diffuser material: Fabric shade Diffuser finish: Opera grey IP20 PAN-177-BY Shade, oval shape, beige fabric, 285x150x150mm Structure material: Steel Diffuser material: Fabric shade Diffuser finish: Sandblasted PAN-177-14 Shade, oval shape, white, 285x150x150mm Structure material: Steel Diffuser material: Fabric shade Diffuser finish: White PAN-157-BY Structure material: Steel Diffuser material: Fabric shade Diffuser finish: Sandblasted IP20 LEDS-C4 reserves the right to make the necessary technical changes they deem adequate, in order to improve the features of the product. Please consult the sales team to clarify any doubt. (+34) 973 468 100 [email protected] www.leds-c4.com PAN-157-14 Shade, white, Ø200mm Structure material: Steel Diffuser material: Fabric shade Diffuser finish: White IP20 PAN-161-14 Structure material: Steel Diffuser material: Fabric shade Diffuser finish: White IP20 LEDS-C4 reserves the right to make the necessary technical changes they deem adequate, in order to improve the features of the product. Please consult the sales team to clarify any doubt. (+34) 973 468 100 [email protected] www.leds-c4.com Luminaire Code 05-1941-81-82 Name LED CE Line Eulumdat Measurem. Code 05-1941-81-82 Name LED CE Date 02-07-2013 Lamp Code Number Position Efficiency 100.00% Coordinate system CG Total Flux Maximum value 417.27 cd Position C=90.00 G=4.00 Asymmetrical 220 mm 220 mm Height Height 05-1941-81-82 1 108.90 lm Round Luminaire Round Luminous Area Diam. Diam. Horizontal Luminous Area Emitting area on Plane 0° Emitting area on Plane 90° 0.038013 m2 0.072600 m2 0.072600 m2 Emitting area on Plane 180° Emitting area on Plane 270° Glare area at 76° 0.072600 m2 0.072600 m2 0.079640 m2 Symmetry Type Measurement Distance Asymmetrical 0.00 Maximum Gamma Angle Measurement Flux 180 108.90 lm Operator Temperature Humidity Notes 25.00 °C 60.00 % Source voltage Source current Photocell Line Eulumdat Code 05-1941-81-82 C.I.E. F UTE 330 mm 330 mm Luminaire Lamps Name 05-1941-81-82 - 4.30 W 91 98 100 100 100 1.00 A D DIN 5040 B NBN Flux [lm] 108.90 Pow. [W] Q.ty 4.30 1 A60 BZ 1 Diam=220mm 90 Gamma Angles 180° 120° 0 90 105° 105° 180 270 90° 90° C Halfplanes 180.0 0.0 270.0 90.0 90 75° 75° 180 60° 60° 270 ULOR 0.00 % DLOR 100.00 % RN 45° 45° 360 0.00 % cd 450 30° LITESTAR (c)OxyTech Srl www.oxytech.it 15° 0° 15° 30° Page 1 LEDS, C4 S.A. CIF/VAT: A-59.410.910 C/ Afueras s/n -TORA- 25750 (LLEIDA) SPAIN TEL: 34 (73) 46 81 02 FAX: 34 (73) 46 81 06 SHEET: 1/2 EDITION: 01 REF: 05-1941U FIGURE Nº 1. UNPACK THE FIXTURE: CHECK THE CONTENTS OF THE BOX. YOU SHOULD RECEIVE: FIGURE 6 FIGURE Nº 1. DÉBALLER LE PLAFONIER: VÉRIFIER LE CONTENU DU CARTON, VOUS DEVEZ RECEVOIR: FIGURE 7 INSTALLATION INSTRUCTIONS FOR HANGING FIXTURES FIGURE 3, 4 AND 5 MOUNTING HARDWARE. NOTE: TEST THE CONNECTOR BY GENTLY PULLING IT. IF IT PULLS OUT THE CONNECTION, TRY AGAIN TILL YOU HAVE A FIRM CONNECTION. MAKE SURE NO BARE STRANDS OF WIRE STICK OUT FROM UNDER THE CONNECTORS. WHITE OR MARKED WIRE FROM FIXTURE WHITE WIRE FROM OUTLET BOX FIGURE 3 BLACK OR UNMARKED WIRE INSTRUCTIONS D'INSTALLATION POUR PLAFONIERS FIGURE 3, 4 ET 5 MONTAGE DE L'ÉQUIPE. IMPORTANT: ESSAYER DE TIRER LE CÂBLE D'ALIMENTATION DOUCEMENT.S'IL SORT DE LA CONNECTION, IL FAUDRAIT ASSURER QUE LA CONNECTION SOIT FERME. S'ASSUSER QUE LES FILS DES CÂBLES NE SONT PAS À DÉCOUVERT DU CONNECTEUR. CÂBLE BLANC OU MARQUÉ DU PLAFONIER CÂBLE NOIRE OU NOU-MARQUÉ BLACK FIGURE 4 FIGURE 5 CÂBLE BLANC DE LA BOÎTE FIGURE 3 NOIRE FIGURE 4 FIGURE 5 CAUTION: ATTENTION: "Warning", "This product is to be installed by a qualified electrician only." "Suitable for dry locations only" "Attention", le raccordement électrique sera effectué par un téchnicien électricien qualifié" "Adéquat seulement en lieux secs." CAUTION: 1.- Wrong lighting installation can be dangerous for your safety. 2.- Before starting, disconnect the power by turning off the general switch of the electric installation. 3.- Install light bulbs (not provided) that must not exceed markings on the fixture. 4.- To change the bulbs, disconnect the power by turning off the general switch and wait for the bulbs cool down. INSTALLATION: 1.- Make electrical connections, carefully read the Electrical Connection section. 2.- Assemble lighting onto the outlet box as shown on fig. 6, & 7. ELECTRICAL CONNECTIONS: (See fig. 3,4 y 5) 1.- Connect the white wire from the fixture to the white wire of the electric installation. 2.- Connect the black wire from the fixture to the black wire of the electric installation. 3.- Connect the grounding conductor from the fixture to the grounding wire of the electric installation. 4.- Spread out the electrical wires so that the black ones are on one side of the outlet box and the white ones are on the other side, and carefully introduce them into the outlet box. ATTENTION: 1. Une mauvaise installation peut compromettre votre sécurité. 2. Déconnecter la tension du réseau d'alimentation avant de réaliser toute opération. 3. Installer les ampoules (non fournies), ne pas utiliser d'ampoules d'un autre type ou d'une puissance supérieure à celle indiquée sur l'étiquette de la lampe. 4. Pour changer les ampoules, déconnecter la tension du réseau d'alimention et laisser refroider les ampoules. INSTALLATION: 1. Connecter au réseau, lire attentivement la section de "Raccordements électriques" 2. Installer l'appareil à la boîte de distribution comme indiqué dans les dessins 6 et 7. RACCORDEMENTS ÉLECTRIQUES (dessins 3,4 et 5) 1. Connecter le câble blanc de l'appareil au câble blanc de l'installation électrique. 2. Connecter le câble noir de l'appareil au câble noir de l'installation électrique. 3. Connecter le câble conducteur de prise de terre au câble de prise de terre de l'installation électrique. 4. Distribuer les câbles pour que tout le câblage noir soit par dehors et le câblage blanc soit par dedans. Ajuster et immobiliser à la boîte sans coincer aucun câble. LEDS, C4 S.A. CIF/VAT: A-59.410.910 C/ Afueras s/n -TORA- 25750 (LLEIDA) SPAIN TEL: 34 (73) 46 81 02 FAX: 34 (73) 46 81 06 SHEET: 2/2 EDITION: 01 REF: 05-1941U 1 1.2 1.1 ON OFF 2 3 ON OFF