Power factor correction and harmonic filtering Rectimat 2 Automatic
Transcription
Power factor correction and harmonic filtering Rectimat 2 Automatic
437E0270_Ver5.0.fm Page 1 Jeudi, 9. décembre 2004 2:38 14 Power factor correction and harmonic filtering Catalogue 2005 Rectimat 2 Automatic capacitor banks Power factor correction and harmonic filtering Contents Rectimat 2 0 Power factor correction 2 Power factor equipment selection guide 3 General technical data 4 Capacitors and banks 50 Hz 6 230 V network voltage 400 V network voltage 6 8 Capacitors and banks 60 Hz 14 240 V network voltage 400 V network voltage 440 V network voltage 480 V network voltage 14 16 20 24 Varlogic N power factor controller 28 1 Power factor correction and harmonic filtering Power factor correction Why reduce power factor ? Many electrical loads (transformers, motors, air conditioners, fluorescent tube ballasts,…) consume reactive power. Power factor correction refers to the installation of a capacitor equipment to provide this reactive power instead of the distribution network. This has the following advantages: b a saving on electrical equipment by a reduction of power demand in kVA b an increasing of the available power at the transformer secondary b fewer voltage drops and Joule losses in a cable b saving on electricity bills through: v the suppression of excessive reactive power consumption v the reduction of maximum power demand. Effects of harmonics on capacitors Some loads (variable speed drives, static converters, welding machines, arc furnaces, fluorescent tubes,…) pollute the electric network by creating harmonics which may cause capacitor overloads. In order to take account of harmonic effects on capacitors, proper section of the type of compensation equipment is essential: b standard type b overrated type (overrated capacitors) b detuned type (overrated capacitors associated with detuned reactors) as described in the paragraph below. For harmonic filtering, please consult us. E89588 Sn kVA How to compensate Capacitor equipment are chosen according to the following criteria: b reactive power to be installed The equipment power Qc (kvar) can be calculated in two ways: v from the reactive power invoiced: monthly bill R (kvar.h) and the operating time of the installation: P kW Gh kVA M Qc kvar P kW Sn: transformer apparent power. Gh: apparent power of harmonic-producing loads (variable speed drives, static converters, power electronics,…) Qc: compensation equipment power. R ( kvar ⋅ h ) Qc ( kvar ) = -----------------------------t (h) v from the active power and the power factor of the installation: Qc (kvar) = P (kW) x (tan ϕ - tan ϕ') where tan ϕ corresponds to the cos ϕ of the installation before compensation and tan ϕ' to the required cos ϕ' after compensation. NB: if Qc > 1000 kvar, HV compensation may be considered. b fixed or automatic compensation In the case of global or workshop compensation, the Qc/Sn criterion enables choice between a fixed and an automatic capacitor bank. The 15 % threshold is a guide value recommended to prevent the eflects of off-load overcompensation. v Qc/Sn < 15 % fixed compensation v Qc/Sn > 15 % automatic compensation. b types of capacitor equipment Capacitor equipment are available in three types depending on the level of harmonic pollution of the network. The Gh/Sn ratio is used to select the type of capacitor equipment required: v if Gh -------- y 15 %, Sn standard type equipement is appropriate. v if 15 % < Gh -------- y 25 %, Sn overrated equipment is designed to withstand harmonic stresses. 470 V rated voltage capacitors are used for 400/415 V network voltage. v if 25 % < Gh -------- y 50 %, Sn detuned type equipment includes 470 V (400/415 V network voltage) rated voltage capacitors associated with detuned reactors. v if Gh -------- > 50 %, Sn filters are recommended to be installed. Please consult us. 2 0 Power factor equipment selection guide Power factor correction and harmonic filtering 0 E89591 230 V to 690 V - 50/60 Hz networks Qc / Sn y 15 % > 15 % Fixed compensation Automatic compensation Gh / Sn Gh / Sn y 15 % 15 to 25 % > 25 % (*) y 15 % 15 to 25 % > 25 % (*) Standard type Overrated type Detuned type Standard type Overrated type Detuned type (*) When Gh/Sn > 50 %, filters are recommended to be installed. Please consult us. Varplus M capacitors Rectibloc fixed capacitor banks Rectimat 2 automatic capacitor banks Reactive compensation equipment in Prisma cubicles Thyrimat capacitor banks with static contactors Filters Sn: transformer apparent power Components and subassemblies for power factor equipment: Power factor correction modules Power factor controllers Gh: apparent power of harmonic-producing loads (variable speed drives, static converters, power electronics,…) Qc: compensation equipment power 3 Power factor correction and harmonic filtering General technical data 0 Compensation banks 056643 Compensation banks are designed for fixed or automatic compensation. Fixed compensation banks These mainly include: b Varplus M capacitors b circuit breaker for protection. Automatic compensation banks These mainly include: b Varplus M capacitors b LC1-D electromagnetic contactors for capacitor switching b a Varlogic N power factor controller according to the controller programming mode (1-1-1-, 1-2-2, 1-1-2)…, the number of apparent steps may be less than the number of electric steps (regulation). Capacitor banks with static contactors Banks equipped with static contactors are available for installations with rapid regulation requirements. Automatic compensation banks Compensation banks with detuned reactors In highly polluted networks, detuned reactors are connected with the capacitors to form a unit tuned at 4.3 (standard value, other tunings on request). These are the detuned type capacitor banks. In some configurations (low Ssc high capacitor power), a different tuning frequency may be required to prevent disturbing the power network remote control frequency. Contact our sales departments. Note: for oversized and detuned type capacitors and banks, the reactive power given is that provided at the network voltage 400 V. PB100025 Power factor correction modules The power factor correction modules are integrated into electrical switchboards to create an automatic compensation equipment. E89589 Power factor correction modules L600 HRC fuse discharge resistor metallic disc overpressure disconnect device Cross-section of a capacitor element 4 They consist of: b Varplus capacitors b LC-D electromagnetic contactors specifically designed to control the capacitors b a set of HBC fuses b a detuned reactor, in the case of heavily polluted networks b a device designed for protection against direct contacts. The sub-assembly function of this pre-wired, fully factory-tested solution carries a comprehensive manufacturer's guarantee. Varplus M capacitors b Varplus M capacitors cover a wide range of voltages (230 V to 690 V) and power rating from a limited number of references b their technology relies on the use of a self-healing metallised polypropylene film requiring no gas or liquid impregnation b the HQ (high quality) protection system built into each capacitor element guarantees operating safety. With its unique, patented design it has been used for more than 10 years on several million elements. It provides protection against the two types of faults encountered as capacitors approach the end of their service life v high current fault protection is provided by a fuse with a high breaking capacity v low current fault protection is provided by the combination of an overpressure disconnect device with the HBC cartridge fuse b whatever the fault, pressure inside the capacitor element is always limited to a value far lower than the maximum admissible pressure b in both cases, a standard HBC fuse is used to break the electric circuit. The plastic enclosure of the Varplus M capacitors has double electrical insulation b the plastics used offer both outstanding mechanical properties and maximum selfextinguishing ratings (UL94 5 VB certification). Power factor correction and harmonic filtering General technical data 0 059646 Varlogic N controllers 059648 Varlogic NR6/NR12 The Varlogic N varmetric controller simplifies the design, installation, supervision and maintenance of reactive power compensation equipment. Its main functions allow it to: b analyse and supply information on network characteristics b control the reactive power needed to obtain the required cos ϕ b monitor and provide information on the state of the compensation equipment b communicate over the Modbus network (NRC12). The varmetric controller range consists of the Varlogic NR6, NR12 and NRC12 controllers for applications requiring a high level of expertise. In addition to their performance, these controllers have been designed to satisfy two main criteria: they must be easy to use and user-friendly. Performance The Varlogic N controller contains a great deal of information about the network and the compensation equipment. Its new regulation algorithm reduces the number of operations and ensures that the required cos ϕ is quickly obtained. In the event of a network or compensation equipment fault, alarms appear on the screen and are also transferred remotely. If required, the steps can be automatically disconnected to protect the equipment. Simplified installation The Varlogic controller simply fits into the compensation cubicle by means of fast connections. A dedicated menu allows the controller parameters to be set automatically and makes the controller easier to use. 051339 Varlogic NRC12 User-friendly interface The Varlogic N has a backlit display unit which allows the electrical information relating to the system and the condition of the steps to be viewed directly. It also allows the settings and parameter configuration to be read directly and ensures easy, intuitive navigation through the various menus. LC1-D electromagnetic contactors for capacitors switching Capacitor switching is followed by transient phenomena resulting from capacitor charging. In particular this creates very high overcurrent which is equivalent to a short circuit of short duration. The use of standard contactors may present risks for reliability of installations. Contactors with unique technology The contactors used in our equipments have specially been designed for capacitor switching. They include a set of contacts and current limiting resistors which are switched off after the initial switching peak. LC1-D contactors Personnel safety Manual operation of contactors is impossible. Contactors include terminal covers for finger contact protection. Safety of installations Current limiting resistors allow to reduce transient overvoltage. Lifetime These specific contactors provide a ready to use solution avoiding installation of damping reactors. Their durability is far greater than that of traditional solutions (300 000 operations at 400 V). 5 Power factor correction and harmonic filtering Capacitors and banks 50 Hz 230 V network voltage 0 Rectimat 2 E56639 The Rectimat 2 capacitor banks are automatic compensation equipment in the form of an enclosure or a cubicle according to the power ratings 056641 Rectimat 2 cubicle 1 Standard type No polluted network (Gh/Sn y 15 %) Rectimat 2 230 V (kvar) 45 60 75 90 105 120 135 150 165 180 195 210 225 240 255 270 285 300 (1) Out of supply. Step Type Recommended Ref. circuit breaker (1) 3 x 15 4 x 15 5 x 15 6 x 15 7 x 15 8 x 15 9 x 15 10 x 15 11 x 15 12 x 15 13 x 15 14 x 15 15 x 15 16 x 15 17 x 15 18 x 15 19 x 15 20 x 15 Cubicle 1 Cubicle 1 Cubicle 1 Cubicle 1 Cubicle 2 Cubicle 2 Cubicle 2 Cubicle 3 Cubicle 3 Cubicle 3 Cubicle 3 Cubicle 4 Cubicle 3 Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4 NS160 NS250 NS400 NS400 NS400 NS630 NS630 NS630 NS630 NS630 NS800 NS800 NS800 NS1000 NS1000 NS1000 NS1000 NS1250 52600 52739 52601 52740 52602 52603 52741 52604 52742 52605 52743 52606 52744 52745 52607 52746 52747 52608 Technical data 056643 Rectimat 2 cubicle 2 b b b v v b b b v v v v b b b b v v b capacitor rated voltage: 240 V, three-phase 50 Hz capacitance value tolerance: -5, +10% insulation level: 0.69 kV withstand 50 Hz 1 min: 2.5 kV. maximum permissible current: 1.3 In (230 V) maximum permissible voltage (8 hours over 24 hours as in IEC 60831): 253 V ambiant temperature around the equipment (electrical room): maximum temperature: 40°C average temperature over 24 hrs: 35°C average annual temperature: 25°C minimum temperature: –5°C. degree of protection: IP21D (except IP00 bottom face ground side) load shedding (main-standby) protection against direct contact (opened door) colour: metal sheet: RAL 9002 bottom blanking plate: RAL 7021. standards: IEC 60439-1, EN 60439-1. Accessories for Rectimat 2 Plinth H = 250 for cubicle 1 Plinth H = 250 for cubicles 2 and 3 Plinth H = 250 for cubicle 4 Rectimat 2 cubicle 3 6 Ref. 52672 52673 2 x 52673 Power factor correction and harmonic filtering Capacitors and banks 50 Hz 230 V network voltage 0 Rectimat 2 Installation b fixing: v enclosure: wall mounting or free standing with plinth (accessory) v cubicle: free standing cubicle or free standing with plinth (accessory). b bottom connection of power cables to the busbar pads b the CT (5 VA sec. 5 A), not supplied, is to be placed upstream from the capacitor bank and loads b it is not necessary to provide a 230 V/60 Hz power supply to supply the contactor coils. Options b b b b b incoming circuit-breaker fixed base compensation extension top connection please consult us for other options. E55193 Dimensions Standard type 230 V (kvar) H L 45 60 75 90 105 120 135 150 165 180 195 210 225 240 255 270 285 300 D E55194 Rectimat 2 cubicles 1 and 2 H L Type Dimensions (mm) H L D Weight (kg) Cubicle 1 Cubicle 1 Cubicle 1 Cubicle 1 Cubicle 2 Cubicle 2 Cubicle 2 Cubicle 3 Cubicle 3 Cubicle 3 Cubicle 3 Cubicle 4 Cubicle 3 Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4 1050 1050 1050 1050 1050 1050 1050 2100 2100 2100 2100 2100 2100 2100 2100 2100 2100 2100 60 65 80 85 140 140 150 160 265 270 280 285 290 300 310 320 325 330 550 550 550 550 800 800 800 800 800 800 800 1600 800 1600 1600 1600 1600 1600 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 D Rectimat 2 cubicles 3 and 4 7 Power factor correction and harmonic filtering Capacitors and banks 50 Hz 400/415 V network voltage 0 Rectimat 2 056637 The Rectimat 2 capacitor banks are automatic compensation equipment in the form of an enclosure or a cubicle according to the power ratings. 056639 Rectimat 2 enclosure 1 Rectimat 2 cubicle 1 Standard type No polluted network (Gh/Sn y 15 %) Rectimat 2 400 V (kvar) 7.5 10 12.5 15 17.5 20 22.5 25 30 Step Type (1) Ref. 400 V (kvar) 67.5 75 90 105 120 150 180 210 240 270 315 360 405 450 495 540 585 630 675 720 765 810 855 900 3x2.5 Enclosure 1 NS100 52812 4x2.5 Enclosure 1 NS100 52813 5x2.5 Enclosure 1 NS100 52814 3x5 Enclosure 1 NS100 52815 7x2.5 Enclosure 1 NS100 52816 4x5 Enclosure 1 NS100 52817 3x7.5 Enclosure 1 NS100 52675 5x5 Enclosure 1 NS100 52818 4x7.5 Enclosure 1 NS100 52609 3x10 Enclosure 1 NS100 52819 6x5 Enclosure 1 NS100 52820 35 7x5 Enclosure 2 NS100 52821 37.5 5x7.5 Enclosure 1 NS100 52676 40 4x10 Enclosure 2 NS100 52822 8x5 Enclosure 2 NS100 52823 45 3x15 Enclosure 1 NS100 52610 6x7.5 Enclosure 2 NS100 52677 9x5 Enclosure 2 NS100 52824 50 5x10 Enclosure 2 NS100 52825 52.5 7x7.5 Enclosure 2 NS160 52678 55 11x5 Enclosure 2 NS160 52826 60 4x15 Enclosure 2 NS160 52611 6x10 Enclosure 2 NS160 52827 8x7.5 Enclosure 2 NS160 52828 62.5 5x12.5 Enclosure 2 NS160 52829 (1) Recommended circuit breaker (out of supply). Step Type (1) Ref. 9x7.5 5x15 3x30 7x15 8x15 5x30 6x30 7x30 8x30 9x30 7x45 8x45 9x45 5x90 11x45 6x90 13x45 7x90 15x45 8x90 17x45 9x90 19x45 10x90 Enclosure 2 Enclosure 2 Cubicle 1 Cubicle 1 Cubicle 2 Cubicle 1 Cubicle 1 Cubicle 2 Cubicle 2 Cubicle 2 Cubicle 3 Cubicle 3 Cubicle 3 Cubicle 3 Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4 NS160 NS160 NS250 NS250 NS250 NS400 NS400 NS630 NS630 NS630 NS630 NS800 NS800 NS1000 NS1000 NS1250 NS1250 NS1250 NS1600 NS1600 NS1600 NS1600 NS2000 NS2000 52830 52612 52613 52614 52615 52616 52617 52618 52619 52620 52621 52622 52623 52624 52625 52626 52627 52628 52629 52630 52631 52632 52633 52634 Technical data 056643 b b b v v b b b v v v v b b b b b v v b capacitor rated voltage: 415 V, three-phase 50 Hz capacitance value tolerance: -5, +10 % insulation level: 0.69 kV withstand 50 Hz 1 min: 2.5 kV. maximum permissible current: 1.3 In (400 V) maximum permissible voltage (8 hours over 24 hours as in IEC 60831): 456 V ambiant temperature around the equipment (electrical room): maximum temperature: 40 °C average temperature over 24 hrs: 35 °C average annual temperature: 25 °C minimum temperature: -5 °C. degree of protection: IP21D (except IP00 bottom face ground side) load shedding (main-standby) transformer 400/230 V to feed auxiliary supplies protection against direct contact (opened door) colour: metal sheet: RAL 9002 bottom blanking plate: RAL 7021. standards: IEC 60439-1, EN 60439-1. Accessories for Rectimat 2 Rectimat 2 cubicle 3 8 Free-standing plinth for enclosures 1 and 2 Plinth H = 250 for cubicle 1 Plinth H = 250 for cubicles 2 and 3 Plinth H = 250 for cubicle 4 Ref. 52671 52672 52673 2 x 52673 Power factor correction and harmonic filtering Capacitors and banks 50 Hz 400 V network voltage 0 Rectimat 2 Installation b fixing: v enclosure: wall mounting or free standing with plinth (accessory) v cubicle: free standing cubicle or free standing with plinth (accessory). b bottom connection of power cables to the busbar pads b the CT (5 VA sec. 5 A), not supplied, is to be placed upstream from the capacitorbank and loads b it is not necessary to provide a 230 V/50 Hz power supply to supply the contactor coils. Options b b b b b incoming circuit-breaker fixed base compensation extension top connection please consult us for other options. E55192 Dimensions Standard type 400 V (kvar) H L 7.5 10 12.5 15 17.5 20 22.5 25 30 35 37.5 40 45 D E55193 Rectimat 2 enclosures 1 and 2 H L D E55194 Rectimat 2 cubicles 1 and 2 H L Rectimat 2 cubicles 3 and 4 D 50 52.5 55 60 62.5 67.5 75 90 105 120 150 180 210 240 270 315 360 405 450 495 540 585 630 675 720 765 810 855 900 3 x 15 6 x 7.5 - 9 x 5 Type Dimensions (mm) H L D Weight (kg) Enclosure 1 Enclosure 1 Enclosure 1 Enclosure 1 Enclosure 1 Enclosure 1 Enclosure 1 Enclosure 1 Enclosure 1 Enclosure 2 Enclosure 1 Enclosure 2 Enclosure 1 Enclosure 2 Enclosure 2 Enclosure 2 Enclosure 2 Enclosure 2 Enclosure 2 Enclosure 2 Enclosure 2 Cubicle 1 Cubicle 1 Cubicle 2 Cubicle 1 Cubicle 1 Cubicle 2 Cubicle 2 Cubicle 2 Cubicle 3 Cubicle 3 Cubicle 3 Cubicle 3 Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4 400 400 400 400 400 400 400 400 400 800 400 800 400 800 800 800 800 800 800 800 800 1050 1050 1050 1050 1050 1050 1050 1050 2100 2100 2100 2100 2100 2100 2100 2100 2100 2100 2100 2100 2100 2100 20 20 20 20 20 20 20 20 20 25 20 25 25 25 25 25 25 40 40 40 45 60 70 70 70 75 90 100 105 155 165 170 180 300 305 315 325 330 340 345 355 360 370 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 550 550 800 550 550 800 800 800 800 800 800 800 1600 1600 1600 1600 1600 1600 1600 1600 1600 1600 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 9 Power factor correction and harmonic filtering Capacitors and banks 50 Hz 400 V network voltage 0 Rectimat 2 056638 The Rectimat 2 capacitor banks are automatic compensation equipment in the form of an enclosure or a cubicle according to the power ratings. 056639 Rectimat 2 enclosure 2 Overrated type Polluted network (15 % < Gh/Sn y 25 %) Rectimat 2 400 V 470 V (kvar) (kvar) 30 41 45 62 50 69 80 110 100 138 120 166 160 221 180 249 210 290 245 338 280 387 315 435 350 483 420 580 455 628 525 725 560 773 630 870 700 966 (1) Out of supply. Step Type 4 x 7,5 6 x 7,5 5 x 10 8 x 10 5 x 20 6 x 20 8 x 20 9 x 20 6 x 35 7 x 35 8 x 35 9 x 35 10 x 35 6 x 70 13 x 35 15 x 35 8 x 70 9 x 70 10 x 70 Enclosure 2 Enclosure 2 Enclosure 2 Cubicle 2 Cubicle 1 Cubicle 1 Cubicle 2 Cubicle 2 Cubicle 2 Cubicle 3 Cubicle 3 Cubicle 3 Cubicle 3 Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4 Recommended circuit breaker (1) NS100 NS100 NS160 NS250 NS250 NS400 NS400 NS400 NS630 NS630 NS630 NS800 NS800 NS1000 NS1000 NS1250 NS1250 NS1600 NS1600 Ref. 52635 52636 52637 52638 52639 52640 52641 52642 52643 52644 52645 52646 52647 52648 52649 52650 52651 52652 52653 Technical data 056643 Rectimat 2 cubicle 1 b b b b v v b b b v v v v b b b b b v v b rated voltage: 400/415 V capacitor rated voltage: 470 V, three-phase 50 Hz capacitance value tolerance: -5, +10 % insulation level: 0.69 kV withstand 50 Hz 1 min: 2.5 kV. maximum permissible current: 1,5 In (400 V). maximum permissible voltage (8 hours over 24 hours as in IEC 60831): 517 V ambiant temperature around the equipment (electrical room): maximum temperature: 40 °C average temperature over 24 hrs: 35 °C average annual temperature: 25 °C minimum temperature: -5 °C. degree of protection: IP21D (except IP00 bottom face ground side) load shedding (main-standby) transformer 400/230 V to feed auxiliary supplies protection against direct contact (opened door) colour: metal sheet: RAL 9002 bottom blanking plate: RAL 7021. standards: IEC 60439-1, EN 60439-1. Accessories for Rectimat 2 Free-standing plinth for enclosures 1 and 2 Plinth H = 250 for cubicle 1 Plinth H = 250 for cubicles 2 and 3 Plinth H = 250 for cubicle 4 Rectimat 2 cubicle 3 10 Ref. 52671 52672 52673 2 x 52673 Power factor correction and harmonic filtering Capacitors and banks 50 Hz 400 V network voltage 0 Rectimat 2 Installation b fixing: v enclosure: wall mounting or free standing with plinth (accessory) v cubicle: free standing cubicle or free standing with plinth (accessory). b bottom connection of power cables to the busbar pads b the CT (5 VA sec. 5 A), not supplied, is to be placed upstream from the capacitor bank and loads b it is not necessary to provide a 230 V/50 Hz power supply to supply the contactor coils. Options b b b b b incoming circuit-breaker fixed base compensation extension top connection please consult us for other options. E55192 Dimensions Overrated type 400 V 470 V (kvar) (kvar) H L 30 45 50 80 100 120 160 180 210 245 280 315 350 420 455 525 560 630 700 D E55193 Rectimat 2 enclosure 2 H H L L D D E55194 Rectimat 2 cubicles 1 and 2 41 62 69 110 138 166 221 249 290 338 387 435 483 580 628 725 773 870 966 Type Dimensions (mm) H L D Weight (kg) Enclosure 2 Enclosure 2 Enclosure 2 Cubicle 2 Cubicle 1 Cubicle 1 Cubicle 2 Cubicle 2 Cubicle 2 Cubicle 3 Cubicle 3 Cubicle 3 Cubicle 3 Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4 800 800 800 1050 1050 1050 1050 1050 1050 2100 2100 2100 2100 2100 2100 2100 2100 2100 2100 40 45 45 70 70 75 100 105 100 160 170 180 190 330 330 345 370 390 390 500 500 500 800 550 550 800 800 800 800 800 800 800 1600 1600 1600 1600 1600 1600 250 250 250 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 H H L L D D Rectimat 2 cubicles 3 and 4 11 Power factor correction and harmonic filtering Capacitors and banks 50 Hz 400 V network voltage 0 Rectimat 2 056641 The Rectimat 2 capacitor banks are automatic compensation equipment in the form of an enclosure. 056643 Rectimat 2 cubicle 2 Rectimat 2 cubicle 3 Detuned type Highly polluted network (25 % < Gh/Sn y 50 %) Rectimat 2 Tuning order 400 V (kvar) 4.3 (215 Hz) 25 37.5 50 62.5 75 100 125 150 150 175 200 250 300 350 400 450 500 550 600 2.7 (135 Hz) 25 37.5 50 62.5 75 100 125 150 150 175 200 250 300 350 400 450 500 550 600 (1) Out of supply. Step Type 2 x 12.5 3 x 12.5 4 x 12.5 5 x 12.5 3 x 25 4 x 25 5 x 25 6 x 25 3 x 50 7 x 25 4 x 50 5 x 50 6 x 50 7 x 50 8 x 50 9 x 50 10 x 50 11 x 50 12 x 50 2 x 12.5 3 x 12.5 4 x 12.5 5 x 12.5 3 x 25 4 x 25 5 x 25 6 x 25 3 x 50 7 x 25 4 x 50 5 x 50 6 x 50 7 x 50 8 x 50 9 x 50 10 x 50 11 x 50 12 x 50 Cubicle 2 Cubicle 2 Cubicle 2 Cubicle 2 Cubicle 2 Cubicle 2 Cubicle 3 Cubicle 3 Cubicle 3 Cubicle 3 Cubicle 3 Cubicle 3 Cubicle 3B Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4B Cubicle 2 Cubicle 2 Cubicle 2 Cubicle 2 Cubicle 3 Cubicle 3 Cubicle 3 Cubicle 3 Cubicle 3 Cubicle 3 Cubicle 3 Cubicle 3B Cubicle 3B Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4B Cubicle 4B Recommended circuit breaker (1) NS100 NS100 NS100 NS160 NS160 NS250 NS250 NS400 NS400 NS400 NS400 NS630 NS630 NS800 NS800 NS1000 NS1000 NS1250 NS1250 NS100 NS100 NS100 NS160 NS160 NS250 NS250 NS250 NS250 NS400 NS400 NS630 NS630 NS630 NS800 NS800 NS1000 NS1000 NS1000 Ref. 52654 52655 52656 52657 52658 52659 52660 52661 52662 52663 52664 52665 52666 52667 52668 52669 52670 52810 52811 51544 51545 54546 51547 51543 51549 51550 51551 51552 51553 51554 51555 51556 51557 51558 51559 51560 51561 51562 Technical data b rated voltage: 400/415 V b capacitor rated voltage: 470 V, three-phase 50 Hz b tuning order: 2.7 (135 Hz) - 4.3 (215 Hz) b capacitance value tolerance: -5, +10 % b insulation level: 0.69 kV, withstand 50 Hz 1 min: 2.5 kV b maximum permissible current: 2.7 (135 Hz): 1.12 In - 4.3 (215 Hz): 1.27 In b ambiant temperature around the equipment (electrical room): v maximum temperature: 40 °C v average temperature over 24 hrs: 35 °C v average annual temperature: 25 °C v minimum temperature: -5 °C. b degree of protection: IP21D (except IP00 bottom face ground side) b load shedding (main-standby) b transformer 400/230 V to feed auxiliary supplies b protection against direct contact (opened door) b colour: v metal sheet: RAL 9002 v bottom blanking plate: RAL 7021. b standards: IEC 60439-1, EN 60439-1. Accessories for Rectimat 2 Ref. Plinth H = 250 for cubicles detuned type 2 and 3 Plinth H = 250 for cubicle detuned type 4 Plinth H = 250 for cubicle detuned type 3B Plinth H = 250 for cubicle detuned type 4B 12 52673 2 x 52673 52672 + 52673 2 x 52673 + 52672 Power factor correction and harmonic filtering Capacitors and banks 50 Hz 400 V network voltage 0 Rectimat 2 Installation b fixing: v cubicle: free standing cubicle or free standing with plinth (accessory). b bottom connection of power cables to the busbar pads b the CT (5 VA sec. 5 A), not supplied, is to be placed upstream from the capacitor bank and loads b it is not necessary to provide a 230 V/50 Hz power supply to supply the contactor coils. Options b b b b incoming circuit-breaker fixed base compensation extension top connection. E62311 Dimensions Detuned type Tuning 400 V order (kvar) H 4.3 (215 Hz) L D E55194 Rectimat 2 cubicle 2 H L Rectimat 2 cubicles 3 and 4 D 2.7 (135 Hz) 25 37.5 50 62.5 75 100 125 150 150 175 200 250 300 350 400 450 500 550 600 25 37.5 50 62.5 75 100 125 150 150 175 200 250 300 350 400 450 500 550 600 Type Cubicle 2 Cubicle 2 Cubicle 2 Cubicle 2 Cubicle 2 Cubicle 2 Cubicle 3 Cubicle 3 Cubicle 3 Cubicle 3 Cubicle 3 Cubicle 3 Cubicle 3B Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4B Cubicle 2 Cubicle 2 Cubicle 2 Cubicle 2 Cubicle 3 Cubicle 3 Cubicle 3 Cubicle 3 Cubicle 3 Cubicle 3 Cubicle 3 Cubicle 3B Cubicle 3B Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4B Cubicle 4B Dimensions (mm) Weight (kg) H L D 1050 1050 1050 1050 1050 1050 2100 2100 2100 2100 2100 2100 2100 2100 2100 2100 2100 2100 2100 1050 1050 1050 1050 2100 2100 2100 2100 2100 2100 2100 2100 2100 2100 2100 2100 2100 2100 2100 800 800 800 800 800 800 800 800 800 800 800 800 1350 1600 1600 1600 1600 1600 2150 800 800 800 800 800 800 800 800 800 800 800 1350 1350 1600 1600 1600 1600 2150 2150 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 115 125 135 145 155 175 290 310 310 330 350 450 460 520 560 600 640 700 740 135 145 155 165 305 310 315 335 335 355 375 480 490 560 600 640 680 745 785 13 Power factor correction and harmonic filtering Capacitors and banks 60 Hz 240 V network voltage 0 Rectimat 2 056641 The Rectimat 2 capacitor banks are automatic compensation equipment in the form of an enclosure or a cubicle according to the power ratings Rectimat 2 cubicle 2 Standard type No polluted network (Gh/Sn y 15 %) Rectimat 2 240 V (kvar) 50 60 80 100 160 200 240 280 320 360 400 (1) Out of supply. Type 5 x 10 6 x 10 4 x 20 5 x 20 4 x 40 5 x 40 6 x 40 7 x 40 8 x 40 9 x 40 10 x 40 Cubicle 1 Cubicle 2 Cubicle 2 Cubicle 2 Cubicle 3 Cubicle 3 Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4 Accessories for Rectimat 2 14 Ref. 71390286 71390287 71390288 71390289 71390290 71390291 71390292 71390293 71390294 71390295 71390296 capacitor rated voltage: 240 V, three-phase 60 Hz capacitance value tolerance: -5, +10 % insulation level: 0.66 kV withstand 60 Hz 1 min: 2,5 kV. maximum permissible current: 1.3 In (240 V) maximum permissible voltage (8 hours over 24 hours as in IEC 60831): 264 V ambiant temperature around the equipment (electrical room): maximum temperature: 40 °C average temperature over 24 hrs: 35 °C average annual temperature: 25 °C minimum temperature: -5 °C. degree of protection: IP21D (except IP00 bottom face ground side) load shedding (main-standby) transformer 240/230 V to feed auxiliary supplies protection against direct contact (opened door) colour: metal sheet: RAL 9002 bottom blanking plate: RAL 7021. standards: IEC 60439-1, EN 60439. Plinth H = 250 for cubicle 1 Plinth H = 250 for cubicle 2 and 3 Plinth H = 250 for cubicle 4 Rectimat 2 cubicle 3 Recommended circuit breaker (1) NS250 NS250 NS400 NS400 NS630 NS800 NS1000 NS1250 NS1250 NS1250 NS1600 Technical data b b b v v b b b v v v v b b b b b v v b 056643 Step Ref. 52672 52673 2 x 52673 Power factor correction and harmonic filtering Capacitors and banks 60 Hz 240 V network voltage 0 Rectimat 2 Installation b fixing: v cubicle: free standing cubicle or free standing with plinth (accessory). b bottom connection of power cables to the busbar pads b the CT (5 VA sec. 5 A), not supplied, is to be placed upstream from the capacitor bank and loads b it is not necessary to provide a 230 V/60 Hz power supply to supply the contactor coils. Option b b b b b incoming circuit-breaker fixed base compensation extension top connection please consult us for other options. E62311 Dimensions Standard type 240 V (kvar) H L 50 60 80 100 160 200 240 280 320 360 400 D E55194 Rectimat 2 cubicles 1 and 2 Type Dimensions (mm) H L D Weight (kg) cubicle 1 Cubicle 2 Cubicle 2 Cubicle 2 Cubicle 3 Cubicle 3 Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4 1050 1050 1050 1050 2100 2100 2100 2100 2100 2100 2100 70 80 90 100 160 180 240 260 280 300 320 550 550 800 800 800 800 1600 1600 1600 1600 1600 500 500 500 500 500 500 500 500 500 500 500 H L D Rectimat 2 cubicles 3 and 4 15 Power factor correction and harmonic filtering Capacitors and banks 60 Hz 400/415 V network voltage 0 Rectimat 2 056637 The Rectimat 2 capacitor banks are automatic compensation equipment in the form of an enclosure or a cubicle according to the power ratings. 056639 Rectimat 2 enclosure 1 Standard type No polluted network (Gh/Sn y 15 %) Rectimat 2 400 V (kvar) 45 60 75 90 105 120 135 150 180 210 240 270 300 360 420 480 540 600 (1) Out of supply. Step Type 3 x 15 4 x 15 5 x 15 6 x 15 7 x 15 8 x 15 9 x 15 5 x 30 6 x 30 7 x 30 8 x 30 9 x 30 5 x 60 6 x 60 7 x 60 8 x 60 9 x 60 10 x 60 Enclosure 1 Enclosure 2 Enclosure 2 Cubicle 1 Cubicle 1 Cubicle 2 Cubicle 2 Cubicle 2 Cubicle 2 Cubicle 3 Cubicle 3 Cubicle 3 Cubicle 3 Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4 Recommended Ref. circuit breaker (1) NS100 72393711 NS160 72393712 NS160 72393713 NS250 72393714 NS250 72393715 NS250 72393716 NS400 72393717 NS400 72393718 NS400 72393719 NS630 72393720 NS630 72393721 NS630 72393722 NS630 72393723 NS800 72393724 NS800 72393725 NS1000 72393726 NS1250 72393727 NS1250 72393728 Technical data 056643 Rectimat 2 cubicle 1 b b b v v b b b v v v v b b b b b v v b capacitor rated voltage: 415 V, three-phase 60 Hz capacitance value tolerance: -5, +10 % insulation level: 0,69 kV withstand 60 Hz 1 min: 2.5 kV. maximum permissible current: 1.3 In (400 V) maximum permissible voltage (8 hours over 24 hours as in IEC 60831): 456 V ambiant temperature around the equipment (electrical room): maximum temperature: 40 °C average temperature over 24 hrs: 35 °C average annual temperature: 25 °C minimum temperature: -5 °C. degree of protection: IP21D (except IP00 bottom face ground side) load shedding (main-standby) transformer 400/230 V to feed auxiliary supplies protection against direct contact (opened door) colour: metal sheet: RAL 9002 bottom blanking plate: RAL 7021. standards: IEC 60439-1, EN 60439-1. Accessories for Rectimat 2 Free-standing plinth for enclosures 1 and 2 Plinth H = 250 for cubicle 1 Plinth H = 250 for cubicles 2 and 3 Plinth H = 250 for cubicle 4 Rectimat 2 cubicle 3 16 Ref. 52671 52672 52673 2 x 52673 Power factor correction and harmonic filtering Capacitors and banks 60 Hz 400 V network voltage 0 Rectimat 2 Installation b fixing: v enclosure: wall mounting or free standing with plinth (accessory) v cubicle: free standing cubicle or free standing with plinth (accessory). b bottom connection of power cables to the busbar pads b the CT (5 VA sec. 5 A), not supplied, is to be placed upstream from the capacitor bank and loads b it is not necessary to provide a 230 V/60 Hz power supply to supply the contactor coils. Options b b b b b incoming circuit-breaker fixed base compensation extension top connection please consult us for other options. E55192 Dimensions Standard type 400 V (kvar) H L 45 60 75 90 105 120 135 150 180 210 240 270 300 360 420 480 540 600 D E55193 Rectimat 2 enclosures 1 and 2 H L D Dimensions (mm) H L D Weight (kg) Enclosure 1 Enclosure 2 Enclosure 2 Cubicle 1 Cubicle 1 Cubicle 2 Cubicle 2 Cubicle 2 Cubicle 2 Cubicle 3 Cubicle 3 Cubicle 3 Cubicle 3 Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4 400 800 800 1050 1050 1050 1050 1050 1050 2100 2100 2100 2100 2100 2100 2100 2100 2100 25 40 45 60 70 80 80 90 90 120 130 140 150 240 260 280 300 320 500 500 500 550 550 800 800 800 800 800 800 800 800 1600 1600 1600 1600 1600 250 250 250 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 E55194 Rectimat 2 cubicles 1 and 2 Type H L D Rectimat 2 cubicles 3 and 4 17 Power factor correction and harmonic filtering Capacitors and banks 60 Hz 400 V network voltage 0 Rectimat 2 056638 The Rectimat 2 capacitor banks are automatic compensation equipment in the form of an enclosure or a cubicle according to the power ratings. Rectimat 2 enclosure 2 Overrated type Polluted network (15 % < Gh/Sn y 25 %) Rectimat 2 400 V 470 V (kvar) (kvar) 50 68 63 85 75 102 100 136 125 170 150 204 200 272 250 340 300 408 350 476 400 544 450 612 500 680 (1) Out of supply. Step Type 4 x 12.5 5 x 12.5 6 x 12.5 4 x 25 5 x 25 6 x 25 4 x 50 5 x 50 6 x 50 7 x 50 8 x 50 9 x 50 10 x 50 Enclosure 1 Enclosure 2 Enclosure 2 Cubicle 1 Cubicle 2 Cubicle 3 Cubicle 3 Cubicle 3 Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4 Recommended Ref. circuit breaker (1) NS160 72393729 NS160 72393730 NS250 72393731 NS250 72393732 NS400 72393733 NS400 72393734 NS630 72393735 NS630 72393736 NS800 72393737 NS800 72393738 NS1000 72393739 NS1000 72393740 NS1250 72393741 056639 Technical data 056643 Rectimat 2 cubicle 1 b b b v v b b b v v v v b b b b b v v b capacitor rated voltage: 470 V, three-phase 60 Hz capacitance value tolerance: -5, +10 % insulation level: 0,69 kV withstand 60 Hz 1 min: 2.5 kV. maximum permissible current: 1.5 In (400 V). maximum permissible voltage (8 hours over 24 hours as in IEC 60831): 517 V ambiant temperature around the equipment (electrical room): maximum temperature: 40 °C average temperature over 24 hrs: 35 °C average annual temperature: 25 °C minimum temperature: -5 °C. degree of protection: IP21D (except IP00 bottom face ground side) load shedding (main-standby) transformer 400/230 V to feed auxiliary supplies protection against direct contact (opened door) colour: metal sheet: RAL 9002 bottom blanking plate: RAL 7021. standards: IEC 60439-1, EN 60439-1. Accessories for Rectimat 2 Free-standing plinth for enclosures 1 and 2 Plinth H = 250 for cubicle 1 Plinth H = 250 for cubicles 2 and 3 Plinth H = 250 for cubicle 4 Rectimat 2 cubicle 3 18 Ref. 52671 52672 52673 2 x 52673 Power factor correction and harmonic filtering Capacitors and banks 60 Hz 400 V network voltage 0 Rectimat 2 Installation b fixing: v enclosure: wall mounting or free standing with plinth (accessory) v cubicle: free standing cubicle or free standing with plinth (accessory). b bottom connection of power cables to the busbar pads b the CT (5 VA sec. 5 A), not supplied, is to be placed upstream from the capacitor bank and loads b it is not necessary to provide a 230 V/60 Hz power supply to supply the contactor coils. Options b b b b b incoming circuit-breaker fixed base compensation extension top connection please consult us for other options. E55192 Dimensions Overrated type 400 V 470 V (kvar) (kvar) H L 50 63 75 100 125 150 200 250 300 350 400 450 500 D E55193 Rectimat 2 enclosures 1 and 2 H L 68 85 102 136 170 204 272 340 408 476 544 612 680 Type Dimensions (mm) H L D Weight (kg) Enclosure 1 Enclosure 2 Enclosure 2 Cubicle 1 Cubicle 2 Cubicle 3 Cubicle 3 Cubicle 3 Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4 400 800 800 1050 1050 2100 2100 2100 2100 2100 2100 2100 2100 25 40 45 70 90 120 140 150 240 260 260 300 320 500 500 500 550 800 800 800 800 1600 1600 1600 1600 1600 250 250 250 500 500 500 500 500 500 500 500 500 500 D E55194 Rectimat 2 cubicles 1 and 2 H L D Rectimat 2 cubicles 3 and 4 19 Power factor correction and harmonic filtering Capacitors and banks 60 Hz 440 V network voltage 0 Rectimat 2 056637 The Rectimat 2 capacitor banks are automatic compensation equipment in the form of an enclosure or a cubicle according to the power ratings. 056639 Rectimat 2 enclosure 1 Standard type No polluted network (Gh/Sn y 15 %) Rectimat 2 440 V (kvar) 45 60 75 90 105 120 135 150 180 210 240 270 300 360 420 480 540 600 (1) Out of supply. Step Type 3 x 15 4 x 15 5 x 15 6 x 15 7 x 15 8 x 15 9 x 15 5 x 30 6 x 30 7 x 30 8 x 30 9 x 30 5 x 60 6 x 60 7 x 60 8 x 60 9 x 60 10 x 60 Enclosure 1 Enclosure 2 Enclosure 2 Cubicle 1 Cubicle 1 Cubicle 2 Cubicle 2 Cubicle 2 Cubicle 2 Cubicle 3 Cubicle 3 Cubicle 3 Cubicle 3 Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4 Recommended circuit breaker (1) NS100 NS160 NS160 NS250 NS250 NS250 NS250 NS400 NS400 NS400 NS630 NS630 NS630 NS800 NS800 NS1000 NS1000 NS1250 Ref. 73391014 73391015 73391016 73391017 73391018 73391019 73391020 73391021 73391022 73391023 73391024 73391025 73391026 73391027 73391028 73391029 73391030 73391031 Technical data 056643 Rectimat 2 cubicle 1 b b b v v b b b v v v v b b b b b v v b capacitor rated voltage: 470 V, three-phase 60 Hz capacitance value tolerance: -5, +10 % insulation level: 0.69 kV withstand 60 Hz 1 min: 2.5 kV. maximum permissible current: 1.3 In (440 V) maximum permissible voltage (8 hours over 24 hours as in IEC 60831): 517 V ambiant temperature around the equipment (electrical room): maximum temperature: 40 °C average temperature over 24 hrs: 35 °C average annual temperature: 25 °C minimum temperature: -5 °C. degree of protection: IP21D (except IP00 bottom face ground side) load shedding (main-standby) transformer 440/230 V to feed auxiliary supplies protection against direct contact (opened door) colour: metal sheet: RAL 9002 bottom blanking plate: RAL 7021. standards: IEC 60439-1, EN 60439-1. Accessories for Rectimat 2 Free-standing plinth for enclosures 1 and 2 Plinth H = 250 for cubicle 1 Plinth H = 250 for cubicles 2 and 3 Plinth H = 250 for cubicle 4 Rectimat 2 cubicle 3 20 Ref. 52671 52672 52673 2 x 52673 Power factor correction and harmonic filtering Capacitors and banks 60 Hz 440 V network voltage 0 Rectimat 2 Installation b fixing: v enclosure: wall mounting or free standing with plinth (accessory) v cubicle: free standing cubicle or free standing with plinth (accessory). b bottom connection of power cables to the busbar pads b the CT (5 VA sec. 5 A), not supplied, is to be placed upstream from the capacitor bank and loads b it is not necessary to provide a 230 V/60 Hz power supply to supply the contactor coils. Options b b b b b incoming circuit-breaker fixed base compensation extension top connection please consult us for other options. E55192 Dimensions Standard type 440 V (kvar) H L 45 60 75 90 105 120 135 150 180 210 240 270 300 360 420 480 540 600 D E55193 Rectimat 2 enclosure 1 and 2 H L D Dimensions (mm) H L D Weight (kg) Enclosure 1 Enclosure 2 Enclosure 2 Cubicle 1 Cubicle 1 Cubicle 2 Cubicle 2 Cubicle 2 Cubicle 2 Cubicle 3 Cubicle 3 Cubicle 3 Cubicle 3 Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4 400 800 800 1050 1050 1050 1050 1050 1050 2100 2100 2100 2100 2100 2100 2100 2100 2100 25 40 45 60 70 80 80 90 90 120 130 140 150 240 260 280 300 320 500 500 500 550 550 800 800 800 800 800 800 800 800 1600 1600 1600 1600 1600 250 250 250 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 E55194 Rectimat 2 cubicles 1 and 2 Type H L D Rectimat 2 cubicles 3 and 4 21 Power factor correction and harmonic filtering Capacitors and banks 60 Hz 440 V network voltage 0 Rectimat 2 056638 The Rectimat 2 capacitor banks are automatic compensation equipment in the form of an enclosure or a cubicle according to the power ratings. 056639 Rectimat 2 enclosure 2 Overrated type Polluted network (15 % < Gh/Sn y 25 %) Rectimat 2 440 V (kvar) 525 V (kvar) 50 72 63 90 75 108 100 144 125 180 150 216 200 288 250 360 300 432 350 504 400 576 450 648 500 720 (1) Out of supply. Step Type 4 x 12.5 5 x 12.5 6 x 12.5 4 x 25 5 x 25 6 x 25 4 x 50 5 x 50 6 x 50 7 x 50 8 x 50 9 x 50 10 x 50 Enclosure 1 Enclosure 2 Enclosure 2 Cubicle 1 Cubicle 2 Cubicle 3 Cubicle 3 Cubicle 3 Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4 Recommended Ref. circuit breaker (1) NS100 73391050 NS160 73391051 NS160 73391052 NS250 73391053 NS250 73391054 NS400 73391055 NS400 73391056 NS630 73391057 NS630 73391058 NS800 73391059 NS800 73391060 NS1000 73391061 NS1000 73391062 Technical data 056643 Rectimat 2 cubicle 1 b b b v v b b b v v v v b b b b b v v b capacitor rated voltage: 525 V, three-phase 60 Hz capacitance value tolerance: -5, +10 % insulation level: 0.69 kV withstand 60 Hz 1 min: 2.5 kV. maximum permissible current: 1.43 In (440 V). maximum permissible voltage (8 hours over 24 hours as in IEC 60831): 577 V ambiant temperature around the equipment (electrical room): maximum temperature: 40 °C average temperature over 24 hrs: 35 °C average annual temperature: 25 °C minimum temperature: -5 °C. degree of protection: IP21D (except IP00 bottom face ground side) load shedding (main-standby) transformer 440/230 V to feed auxiliary supplies protection against direct contact (opened door) colour: metal sheet: RAL 9002 bottom blanking plate: RAL 7021. standards: IEC 60439-1, EN 60439-1. Accessories for Rectimat 2 Free-standing plinth for enclosures 1 and 2 Plinth H = 250 for cubicle 1 Plinth H = 250 for cubicles 2 and 3 Plinth H = 250 for cubicle 4 Rectimat 2 cubicle 3 22 Ref. 52671 52672 52673 2 x 52673 Power factor correction and harmonic filtering Capacitors and banks 60 Hz 440 V network voltage 0 Rectimat 2 Installation b fixing: v enclosure: wall mounting or free standing with plinth (accessory) v cubicle: free standing cubicle or free standing with plinth (accessory). b bottom connection of power cables to the busbar pads b the CT (5 VA sec. 5 A), not supplied, is to be placed upstream from the capacitor bank and loads b it is not necessary to provide a 230 V/60 Hz power supply to supply the contactor coils. Options b b b b b incoming circuit-breaker fixed base compensation extension top connection please consult us for other options. E55192 Dimensions Overrated type 440 V 525 V (kvar) (kvar) H L 50 63 75 100 125 150 200 250 300 350 400 450 500 D E55193 Rectimat 2 enclosure 2 H L 72 90 108 144 180 216 288 360 432 504 576 648 720 Type Dimensions (mm) H L D Weight (kg) Enclosure 1 Enclosure 2 Enclosure 2 Cubicle 1 Cubicle 2 Cubicle 3 Cubicle 3 Cubicle 3 Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4 400 800 800 1050 1050 2100 2100 2100 2100 2100 2100 2100 2100 25 40 45 70 90 120 140 150 240 260 280 300 320 500 500 500 550 800 800 800 800 1600 1600 1600 1600 1600 250 250 250 500 500 500 500 500 500 500 500 500 500 D E55194 Rectimat 2 cubicles 1 and 2 H L D Rectimat 2 cubicles 3 and 4 23 Power factor correction and harmonic filtering Capacitors and banks 60 Hz 480 V network voltage 0 Rectimat 2 056637 The Rectimat 2 capacitor banks are automatic compensation equipment in the form of an enclosure or a cubicle according to the power ratings. 056639 Rectimat 2 enclosure 1 Standard type No polluted network (Gh/Sn y 15 %) Rectimat 2 480 V (kvar) 45 60 75 90 105 120 135 150 180 210 240 270 300 360 420 480 540 600 (1) Out of supply. Step Type 3 x 15 4 x 15 5 x 15 6 x 15 7 x 15 8 x 15 9 x 15 5 x 30 6 x 30 7 x 30 8 x 30 9 x 30 5 x 60 6 x 60 7 x 60 8 x 60 9 x 60 10 x 60 Enclosure 1 Enclosure 2 Enclosure 2 Cubicle 1 Cubicle 1 Cubicle 2 Cubicle 2 Cubicle 2 Cubicle 2 Cubicle 3 Cubicle 3 Cubicle 3 Cubicle 3 Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4 Recommended circuit breaker (1) NS100 NS100 NS160 NS160 NS250 NS250 NS250 NS250 NS400 NS400 NS400 NS630 NS630 NS630 NS800 NS800 NS1000 NS1000 Ref. 73391032 73391033 73391034 73391035 73391036 73391037 73391038 73391039 73391040 73391041 73391042 73391043 73391044 73391045 73391046 73391047 73391048 73391049 Technical data 056643 Rectimat 2 cubicle 1 b b b v v b b b v v v v b b b b b v v b capacitor rated voltage: 525 V, three-phase 60 Hz capacitance value tolerance: -5, +10 % insulation level: 0.69 kV withstand 60 Hz 1 min: 2.5 kV. maximum permissible current: 1.3 In (480 V) maximum permissible voltage (8 hours over 24 hours as in IEC 60831): 577 V ambiant temperature around the equipment (electrical room): maximum temperature: 40 °C average temperature over 24 hrs: 35 °C average annual temperature: 25 °C minimum temperature: -5 °C. degree of protection: IP21D (except IP00 bottom face ground side) load shedding (main-standby) transformer 480/230 V to feed auxiliary supplies protection against direct contact (opened door) colour: metal sheet: RAL 9002 bottom blanking plate: RAL 7021. standards: IEC 60439-1, EN 60439-1. Accessories for Rectimat 2 Free-standing plinth for enclosures 1 and 2 Plinth H = 250 for cubicle 1 Plinth H = 250 for cubicles 2 and 3 Plinth H = 250 for cubicle 4 Rectimat 2 cubicle 3 24 Ref. 52671 52672 52673 2 x 52673 Power factor correction and harmonic filtering Capacitors and banks 60 Hz 480 V network voltage 0 Rectimat 2 Installation b fixing: v enclosure: wall mounting or free standing with plinth (accessory) v cubicle: free standing cubicle or free standing with plinth (accessory). b bottom connection of power cables to the busbar pads b the CT (5 VA sec. 5 A), not supplied, is to be placed upstream from the capacitor bank and loads b it is not necessary to provide a 230 V/60 Hz power supply to supply the contactor coils. Options b b b b b incoming circuit-breaker fixed base compensation extension top connection please consult us for other options. E55192 Dimensions Standard type 480 V (kvar) H L 45 60 75 90 105 120 135 150 180 210 240 270 300 360 420 480 540 600 D E55193 Rectimat 2 enclosures 1 and 2 H L D Dimensions (mm) H L D Weight (kg) Enclosure 1 Enclosure 2 Enclosure 2 Cubicle 1 Cubicle 1 Cubicle 2 Cubicle 2 Cubicle 2 Cubicle 2 Cubicle 3 Cubicle 3 Cubicle 3 Cubicle 3 Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4 400 800 800 1050 1050 1050 1050 1050 1050 2100 2100 2100 2100 2100 2100 2100 2100 2100 25 40 45 60 70 80 80 90 90 120 130 140 150 240 260 280 300 320 500 500 500 550 550 800 800 800 800 800 800 800 800 1600 1600 1600 1600 1600 250 250 250 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 E55194 Rectimat 2 cubicles 1 and 2 Type H L D Rectimat 2 cubicles 3 and 4 25 Power factor correction and harmonic filtering Capacitors and banks 60 Hz 480 V network voltage 0 Rectimat 2 056638 The Rectimat 2 capacitor banks are automatic compensation equipment in the form of an enclosure or a cubicle according to the power ratings. Rectimat 2 enclosure 2 Overrated type Polluted network (15 % < Gh/Sn y 25 %) Rectimat 2 480 V (kvar) 50 63 75 100 125 150 200 250 300 350 400 450 500 525 V (kvar) 60 75 90 120 150 180 240 300 360 420 480 540 600 Step 4 x 12.5 5 x 12.5 6 x 12.5 4 x 25 5 x 25 6 x 25 4 x 50 5 x 50 6 x 50 7 x 50 8 x 50 9 x 50 10 x 50 Type Enclosure 1 Enclosure 2 Enclosure 2 Cubicle 1 Cubicle 2 Cubicle 3 Cubicle 3 Cubicle 3 Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4 Recommended Ref. circuit breaker (1) NS100 73391063 NS160 73391064 NS160 73391065 NS250 73391066 NS250 73391067 NS400 73391068 NS400 73391069 NS630 73391070 NS630 73391071 NS800 73391072 NS800 73391073 NS1000 73391074 NS1000 73391075 056639 (1) Out of supply. Technical data 056643 Rectimat 2 cubicle 1 b b b v v b b b v v v v b b b b b v v b capacitor rated voltage: 525 V, three-phase 60 Hz capacitance value tolerance: -5, +10 % insulation level: 0.69 kV withstand 60 Hz 1 min: 2.5 kV. maximum permissible current: 1.43 In (480 V). maximum permissible voltage (8 hours over 24 hours as in IEC 60831): 577 V ambiant temperature around the equipment (electrical room): maximum temperature: 40 °C average temperature over 24 hrs: 35 °C average annual temperature: 25 °C minimum temperature: -5 °C. degree of protection: IP21D (except IP00 bottom face ground side) load shedding (main-standby) transformer 480/230 V to feed auxiliary supplies protection against direct contact (opened door) colour: metal sheet: RAL 9002 bottom blanking plate: RAL 7021. standards: IEC 60439-1, EN 60439-1. Accessories for Rectimat 2 Free-standing plinth for enclosures 1 and 2 Plinth H = 250 for cubicle 1 Plinth H = 250 for cubicles 2 and 3 Plinth H = 250 for cubicle 4 Rectimat 2 cubicle 3 26 Ref. 52671 52672 52673 2 x 52673 Power factor correction and harmonic filtering Capacitors and banks 60 Hz 480 V network voltage 0 Rectimat 2 Installation b fixing: v enclosure: wall mounting or free standing with plinth (accessory) v cubicle: free standing cubicle or free standing with plinth (accessory). b bottom connection of power cables to the busbar pads b the CT (5 VA sec. 5 A), not supplied, is to be placed upstream from the capacitor bank and loads b it is not necessary to provide a 230 V/60 Hz power supply to supply the contactor coils. Options b b b b b incoming circuit-breaker fixed base compensation extension top connection please consult us for other options. E55192 Dimensions Overrated type 480 V 525 V (kvar) (kvar) H L 50 63 75 100 125 150 200 250 300 350 400 450 500 D E55193 Rectimat 2 enclosures 1 and 2 H L 60 75 90 120 150 180 240 300 360 420 480 540 600 Type Dimensions (mm) H L D Weight (kg) Enclosure 1 Enclosure 2 Enclosure 2 Cubicle 1 Cubicle 2 Cubicle 3 Cubicle 3 Cubicle 3 Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4 Cubicle 4 400 800 800 1050 1050 2100 2100 2100 2100 2100 2100 2100 2100 25 40 45 70 90 120 140 150 240 260 280 300 320 500 500 500 550 800 800 800 800 1600 1600 1600 1600 1600 250 250 250 500 500 500 500 500 500 500 500 500 500 D E55194 Rectimat 2 cubicles 1 and 2 H L D Rectimat 2 cubicles 3 and 4 27 Power factor correction and harmonic filtering 059646 The Varlogic N controllers permanently measure the reactive power of the installation and control connection and disconnection of capacitor steps in order to obtain the required power factor. 059648 Varlogic NR6/NR12 Varlogic NRC12 Varlogic N power factor controller Technical data b general data v operating temperature: 0…60 °C v storage temperature: -20° C…60 °C v colour: RAL 7016 v standard: - EMC: IEC 61326 - electrical: IEC/EN 61010-1. v panel mounting v mounting on 35 mm DIN rail (EN 50022) v protection class in panel mounting: - front face: IP41 - rear face: IP20. v display: - NR6, NR12 type: backlighted screen 65 x 21 mm - NRC12 type: backlighted graphic screen 55 x 28 mm. - languages: English, French, German, Portuguese, Spanish v alarm contact v temperature internal probe v separate contact to control fan inside the power factor correction bank v access to the history of alarm. b inputs v phase to phase or phase to neutral connection v insensitive to CT polarity v insensitive to phase rotation polarity v current input: - NR6, NR12 type: CT… X/5 A - NRC12 type: CT… X/5 A et X/1 A. b outputs v potential free output contacts: - AC : 1 A/400 V, 2 A/250 V, 5 A/120 V - DC : 0,3 A/110 V, 0,6 A/60 V, 2 A/24 V. b settings and parameters v target cos ϕ setting: 0,85 ind…0,9 cap v possibility of a dual cos ϕ target (type NRC12) v manual or automatic parameter setting of the power factor controller v choice of different stepping programs: - linear - normal - circular - optimal. v main step sequences: 1.1.1.1.1.1 1.2.2.2.2.2 1.2.3.4.4.4 1.1.2.2.2.2 1.2.3.3.3.3 1.2.4.4.4.4 1.1.2.3.3.3 1.2.4.8.8.8 v personalized sequences for NRC12 type v delay between 2 successive switch on of a same step: - NR6, NR12 type: 10 … 600 s - NRC12 type: 10 … 900 s v step configuration programming (fixed/auto/disconnected) (NRC12 type) v 4 quadrant operation for generator application (NRC12 type) v manuel control for operating test. E88926 Dimensions Varlogic N H 138 Varlogic NR6/NR12 Varlogic NRC12 138 L Varlogic NR6, NR12, NRC12 28 D2 D1 Dimensions (mm) H L D1 D2 Weight (kg) 150 150 70 80 60 70 1 1 150 150 0 Power factor correction and harmonic filtering Type NR6 NR12 NRC12 Varlogic N power factor controller Number of step output contacts Supply voltage (V) network 50-60 Hz Measuring voltage (V) ref. 6 12 12 110-220/240-380/415 110-220/240-380/415 110-220/240-380/415 110-220/240-380/415 110-220/240-380/415 110-220/240-380/415-690 52448 52449 52450 Varlogic N accessories ref. Communication RS485 Modbus set for NRC12 Temperature external probe for NRC12 type. In addition to internal proble, allows measurement at the hotest point inside the capacitor bank. Better tuning of alarm and/or disconnection level. Information supplied Cos ϕ Connected steps Switching cycles and connected time counter Step configuration (fixed step, auto, disconnected) Step output status (capacitance loss monitoring) Network technical data: load and reactive currents, voltage, powers (S, P, Q) Ambient temperature inside the cubicle Total voltage harmonic distortion THD (U) Total current harmonic distortion THD (I) Capacitor current overload Irms/I 1 Voltage and current harmonic spectrum (orders 3, 5, 7, 11, 13) History of alarms Alarms Low power factor Hunting (unstable regulation) Abnormal cos ϕ Overcompensation Overcurrent Voltage low Overvoltage Overtemperature Threshold < 0.5 ind or 0.8 cap 52451 52452 NR6/NR12 NRC12 b b b b b b b b b b b b b b b b b b b Action NR6/NR12 NRC12 message and alarm contact message and alarm contact message and alarm contact message and alarm contact message and alarm contact message and alarm contact message and alarm contact message and alarm contact fan switch message and alarm contact message and alarm contact message and alarm contact message message message b b b b b b b b b b b b b b b b b b b b b b b b b > 115 % I1 < 80 % Uo within 1 s > 110 % Uo θ u θo (θo = 50 °C max)(1) θ u θo - 15 °C Total harmonic distortion > 7 % (1) Capacitor current overload (Irms/I 1) > 1.5 (1) Capacitor capacitance loss - 25 % Low current < 2,5 % High current > 115 % Under voltage 5 % Uo Uo: input voltage (measurement) (1): alarm threshold values can be modified according to the installation (2): capacitor steps are automatically reconnected after fault clearance and a safety delay disconnection (2) disconnection (2) disconnection (2) disconnection (2) disconnection (2) disconnection (2) disconnection (2) disconnection (2) b b 29 0 Schneider Electric Industries SAS Rectiphase 399, rue de la Gare 74370 Pringy cedex France tél. : (33) 04 50 66 95 00 fax : (33) 04 50 27 24 19 As standards, specifications and designs change from time to time, please ask for confirmation of the information given in this publication. This document has been printed on ecological paper. Design and published by: Schneider Electric Photos: Schneider Electric Printed: ART96966 CFIED200087EN 11-2004 © 2004 - Schneider Electric - All rights reserved 437E0270_Ver5.0.fm Page 2 Jeudi, 9. décembre 2004 2:38 14