Dual inlet centrifugal fans RDH
Transcription
Dual inlet centrifugal fans RDH
Dual inlet centrifugal fans RDH APPLICATION eccentric ring shaft locking whose design working life is about 40,000 hours. These dual inlet centrifugal fans are equipped with reaction impellers (backwards curved blades). They are designed to transfer large flows at medium pressures, and are used to transport clean air at a maximum temperature of +40°C. The casing is made of pre-galvanised sheet steel and the frame of painted rolled-steel angle bars. A transmission protection housing (pre-galvanised panels and electro-zinc grille) is supplied as standard. In a metal angle-bar frame, the casings are positioned in 4 different orientations (0°, 90°, 180°, 270°) each available in two directions of rotation: clockwise and anti-clockwise (see. § “Orientations – Direction of rotation” next page) depending on which side of the casing the motor is placed. The steel impeller is statically and dynamically balanced and class G6.3 in accordance with ISO 1940. OPTIONS DESCRIPTION O Depending on the application the motors supplied as standard have a 230/400V or 400/690V supply voltage. Degree of protection IP55, Temperature class F. ►epoxy paint ►special low temperature assembly (-30°C) ►dual or triple versions ►chassis mounting for large drive units The bearings are fitted with self-aligning ball-bearings with CENTRIFUGAL S DIMENSIONS A B C E H 180 294 336 229 229 200 306 370 256 225 345 415 288 250 381 461 280 429 315 480 355 400 J K L M P S V X1 X2 UxS 322 150 269 470 259 5 20 180 180 11x16 256 343 150 306 513 286 4 25 224 224 11x16 288 382 150 338 544 318 3 25 224 224 11x16 322 322 416 150 372 594 352 4 25 224 224 11x16 518 361 361 463 150 421 651 391 5 30 280 280 13x18 578 404 404 516 150 464 695 434 3 30 280 280 13x18 544 655 453 453 574 150 533 759 493 6 40 355 355 13x18 613 736 507 507 651 150 587 819 547 5 40 355 355 13x18 450 681 827 569 569 726 150 649 900 619 5 40 530 530 13x18 500 750 918 638 638 800 150 718 969 688 5 40 530 530 13x18 560 845 1030 715 715 893 150 815 1093 765 7 50 530 530 13x18 630 940 1157 801 801 993 150 901 1178 851 6 50 530 530 13x18 710 1050 1303 898 898 1113 150 998 1277 948 7 50 630 630 17x22 800 1181 1468 1007 1007 1255 150 1107 1384 1057 7 50 710 710 17x22 900 1319 1648 1130 1130 1408 150 1230 1525 1180 7 50 800 800 17x22 1000 1451 1810 1267 1267 1541 150 1367 1664 1317 9 50 900 900 17x22 DEPENDING ON DRIVE TYPE AREM - ZI, chemin des aisières - 45500 Saint-Brisson sur Loire - Tel: 00 33 (0)2.38.36.71.05 - Email : [email protected] 105 Catalogue 2008 Edition Dual inlet centrifugal fans RDH ORIENTATION – DIRECTION OF ROTATION LG 0 LG 90 LG 180 LG 270 RD 0 RD 90 RD 180 RD 270 CENTRIFUGAL S POSITIONS OF MOTORS ABOUT ORIENTATIONS For centrifugal fans, whether with single or dual air inlets, the convention states that orientations take the motor side (direct action) or the transmission side as a reference. If the impeller rotates in a clockwise direction (or “to the right”) its direction will be RD; if it rotates in and anti-clockwise direction its direction will be LG. - CONSTRUCTIONS The position of the motor will depend on the space available for location of the fan. To designate the appropriate position, specify the orientation (LG or RD) followed by the following motor position number: 1 2 3 4 5 6 1 2 3 4 5 6 DUAL OR TRIPLE CONSTRUCTION Please contact us AREM - ZI, chemin des aisières - 45500 Saint-Brisson sur Loire - Tel: 00 33 (0)2.38.36.71.05 - Email : [email protected] 106 Catalogue 2008 Edition Dual inlet centrifugal fans RDH ACCESSORIES COMPANION FLANGE AT DISCHARGE A B C E F L 180 229 285 129.5 - - 30 200 256 312 143 - - 30 225 288 344 159 - - 30 250 322 378 176 - - 30 280 361 417 195.5 - - 30 315 404 460 217 - - 30 355 453 509 241.5 - - 30 400 507 563 - 200 168.5 30 450 569 625 - 200 199.5 30 500 638 694 - 250 209 30 560 715 771 - 250 247.5 30 630 801 857 - 300 265.5 30 710 898 954 - 400 264 30 800 1007 1063 - 500 268.5 30 900 1130 1186 - 600 280 30 1000 1267 1323 - 700 298.5 30 180 to 355 CENTRIFUGAL S 1 710 to 1000 400 to 630 2 Textile component between two strips of thin panel shaped to match the sleeve and riveted or screwed onto the latter. Factory installed it is fixed in place using self-tapping screws. 2 3 FLEXIBLE SLEEVE AT DISCHARGE ANTI-VIBE MOUNTS LOAD/MOUNT (KG) A B d 25 24 76 8.5 Ø80 110 27 100 8.2 Ø100 160 28 124 10 Ø150 250 39 182 12 Ø60 3 AREM - ZI, chemin des aisières - 45500 Saint-Brisson sur Loire - Tel: 00 33 (0)2.38.36.71.05 - Email : [email protected] 107 Catalogue 2008 Edition Dual inlet centrifugal fans RDH ACCESSORIES (cont) 4 INSPECTION HATCHES Above These are used to allow cleaning of the fan and of the internal walls of the casing. Included on request in the three positions indicated in the diagram below, they are fixed in place using self-tapping screws. 4 Rear Below CENTRIFUGAL S 5 Intended for the removal of condensation and of water used in cleaning the equipment, it is made up of an M10 diam. insert plugged with a bolt, applied to the bottom part of the casing. If necessary, a hose can extend this device to connect to pipework. For factory installation the fan orientation must be specified. 5 6 VENT HOLE RUN/STOP SWITCH Accessory fitted pre-wired. 6 7 7 MOTOR COVER Provides protection of the motor against rain and any other spays, it is fixed directly on the transmission housing. AREM - ZI, chemin des aisières - 45500 Saint-Brisson sur Loire - Tel: 00 33 (0)2.38.36.71.05 - Email : [email protected] 108 Catalogue 2008 Edition