Dual inlet centrifugal fans T D A

Transcription

Dual inlet centrifugal fans T D A
Dual inlet centrifugal fans
TDA
40,000 hours in standard operation.
A transmission protection housing (pre-galvanised panels and
electro-zinc grille) is supplied as standard.
In a metal angle-bar frame, the casings are positioned in 4
different orientations (0°, 90°, 180°, 270°) each available in
two directions of rotation: clockwise and anti-clockwise
(see. § “Orientations – Direction of rotation” next page)
depending on which side of the casing the motor is
placed.
APPLICATION
These dual inlet centrifugal fans are equipped with impulse
impellers (forwards curved blades). They are designed to
transfer large flows at medium and low pressures, and can
be used to transport clean air at a maximum temperature of
+40°C.
DESCRIPTION
The casing is made of pre-galvanised sheet steel.
OPTIONS
Pre-galvanised steel impellers are statically and dynamically
balanced: class G6.3 in accordance with standard ISO 1940.
►epoxy paint
►special low temperature assembly (-30°C)
►dual or triple versions
►chassis mounting for large drive units
Depending on the application, the motors supplied as standard
have a 230/400V or 400/690V supply voltage. Degree of
protection IP55, Temperature class F.
The bearings are fitted with self-aligning ball-bearings with
eccentric ring shaft locking with a design working life of about
CENTRIFUGAL
S
DIMENSIONS
A
B
C
E
H
7/7
295
330
209
232
9/9
355
404
265
10/10
402
452
12/12
475
15/15
J
K
L
M
P
S
V
X1
X2
ØR
315
150
280
478.5
258
6
24
220
255
10
298
380
150
346
536
323
6
24
280
327
10
290
326
432
150
374
574
350
6
24
326
377
10
534
342
386
505
150
444
644
416
6
29
384
443
10
553
622
404
473
585
150
532
732
504
6
29
460
531
10
18/18
666
754
480
556
700
150
626
826
592
6
35
553
641
10
20/20
795
935
604
602
840
150
682
927
642
6
40
595
735
12
22/22
863
1019
695
655
908
150
735
980
695
6
40
663
819
12
25/25
953
1142
794
765
998
150
845
1090
805
6
40
753
942
12
30/28
1159
1374
933
890
1204
150
970
1250
930
6
40
959
1174
12
DEPENDING ON DRIVE
TYPE
AREM - ZI, chemin des aisières - 45500 Saint-Brisson sur Loire - Tel: 00 33 (0)2.38.36.71.05 - Email : [email protected]
109
Catalogue 2008 Edition
Dual inlet centrifugal fans
TDA
ORIENTATION – DIRECTION OF ROTATION
LG 0
LG 90
LG 180
LG 270
RD 0
RD 90
RD 180
RD 270
CENTRIFUGAL
S
POSITIONS
OF MOTORS
ABOUT ORIENTATIONS
For centrifugal fans, whether with single or
dual air inlet, the convention states that
orientations take the motor side (direct action)
or the transmission side as a reference.
If the impeller rotates in a clockwise direction
(or “to the right”) its direction will be RD; if it
rotates in and anti-clockwise direction its
direction will be LG.
- CONSTRUCTIONS
The position of the motor will depend on the space available for location of the fan. To designate the appropriate position, specify
the orientation (LG or RD) followed by the following motor position number:
- - N
IER
CT
1
2
3
4
5
6
1
2
3
4
5
6
DUAL OR TRIPLE CONSTRUCTION
Please contact us
AREM - ZI, chemin des aisières - 45500 Saint-Brisson sur Loire - Tel: 00 33 (0)2.38.36.71.05 - Email : [email protected]
110
Catalogue 2008 Edition
Dual inlet centrifugal fans
TDA
1
COMPANION FLANGE AT DISCHARGE
A
B
a
b
7/7
260
282
210
232
9/9
315
348
265
10/10
340
376
12/12
392
15/15
vxt
zxt
y
x
Ød
L
1x125 1x125
55.5
66.5
8
25
298
1x125 1x125
83
99.5
8
25
290
326
1x125 1x125
95.5
113.5
8
25
436
342
386
1x125 1x125
121.5
143.5
8
25
452
524
402
474
1x125 3x125
151.5
62.5
8
25
18/18
530
590
480
540
3x125 3x125
65.5
95.5
8
25
20/20
684
682
604
602
3x125 3x125
134.5
133.5
12
40
22/22
774
735
694
655
5x125 3x125
54.5
160
12
40
25/25
875
845
795
764
5x125 5x125
105
90
12
40
30/28
1014
968
934
888
7x125 5x125
49.5
151.5
12
40
CENTRIFUGAL
S
ACCESSORIES
1
2
Textile component between two strips of thin panel shaped to match the sleeve and
riveted or screwed onto the latter.
Factory installed it is fixed in place using self-tapping screws.
2
3
FLEXIBLE SLEEVE AT DISCHARGE
ANTI-VIBE MOUNTS
LOAD/MOUNT (KG)
A
B
d
25
24
76
8,5
Ø80
110
27
100
8.2
Ø100
160
28
124
10
Ø150
250
39
182
12
Ø60
3
AREM - ZI, chemin des aisières - 45500 Saint-Brisson sur Loire - Tel: 00 33 (0)2.38.36.71.05 - Email : [email protected]
111
Catalogue 2008 Edition
Dual inlet centrifugal fans
TDA
ACCESSORIES (cont)
4
INSPECTION HATCHES
Above
These are used to allow cleaning of the fan and
of the internal walls of the casing. Included on
request at the four positions indicated in the
diagram below, they are fixed in place using
self-tapping screws.
Upper rear
4
Front
Lower rear
CENTRIFUGAL
S
5
- - N
IER
CT
Provided for the removal of condensation and of water used in
cleaning the equipment, it is made up of an M10 diam. insert
plugged with a bolt attached to the bottom part of the casing. If
necessary, a hose can extend this device to connect to
pipework.
For factory installation, the fan orientation must be specified
5
6
VENT HOLE
AIR INLET GRILLES
These are 2 half-grilles to be fitted using self-tapping screws directly onto
the sides of the casing.
7
6
RUN/STOP SWITCH
Accessory fitted pre-wired.
7
8
8
MOTOR COVER
Provides protection of the motor against rain and any other spays, it is
fixed directly on the transmission housing.
AREM - ZI, chemin des aisières - 45500 Saint-Brisson sur Loire - Tel: 00 33 (0)2.38.36.71.05 - Email : [email protected]
112
Catalogue 2008 Edition

Documents pareils

Single inlet centrifugal fans VRD

Single inlet centrifugal fans VRD The motors supplied as standard have, depending on the application, 230/400V or 400/690V supply voltages. IP55 degree of protection. Temperature class F. The bearings are equipped with self-alignin...

Plus en détail