amendment / modification 004
Transcription
amendment / modification 004
RETURN BIDS TO: RETOURNER LES SOUMISSIONS Á: Parks Canada Agency 1300 - 635 8 Ave SW Calgary, AB T2P3M3 Bid Fax: (403) 292-4475 AMENDMENT / MODIFICATION Title-Sujet Lake Louise Wastewater Treatment Plant Upgrades Banff National Park Solicitation No. - No. de l’invitation Date: 5P420-16-5057/A May 31, 2016 GETS Reference No. – No de reference de SEAG Amendment No. - N° de la modif. PW-16-00732392 Solicitation Closes: 004 at – á 02:00 PM Tender To: Parks Canada Agency We hereby offer to sell to Her Majesty the Queen in right of Canada, in accordance with the terms and conditions set out herein, referred to herein or attached hereto, the goods, services, and construction listed herein and on any attached sheets at the price(s) set out therefor. F.O.B. - F.A.B. Soumission aux: l’Agence Parcs Canada Nous offrons par la présente de vendre à Sa Majesté la Reine du Chef du Canada, aux conditions énoncées ou incluses par référence dans la présente at aux annexes ci-jointes, les biens, services et construction énumérés ici et sur toute feuille ci-annexée, au(x) prix indiqué(s). 004 on – le June 7, 2016 Plant-Usine: Time Zone - Fuseau horaire MDT - HNR Destination: Other-Autre: Address Inquiries to: - Adresser toute demande de renseignements à : Jen Maheu Telephone No. - No de téléphone (403) 292-8502 Fax No. – No de FAX: (403) 292-4475 Destination of Goods, Services, and Construction: Destinations des biens, services et construction: See Herein – Voir ici TO BE COMPLETED BY THE BIDDER (type or print) Comments - Commentaries Vendor/Firm Name Vendor/Firm Name and Address Raison sociale et adresse du fournisseur/de l’entrepreneur Address - Adresse Name of person authorized to sign on behalf of the Vendor/Firm Nom de la personne autorisée a signer au nom du fournisseur/ de l’entrepreneur Issuing Office - Bureau de distribution Titale - Titre Parks Canada Agency Suite 1300 635 – 8 Ave SW Calgary, AB T2P3M3 Telephone No. - N° de telephone: Facsimile No. - N° de télécopieur: Signature Date Solicitation No. - N° de l'invitation 5P420-16-5057/A Amd. No. - N° de la modif. 004 Buyer - l'acheteur Jen Maheu Client Ref. No. - N° de réf. du client 1680-5234-14 File Name - Nom du dossier Lake Louise Wastewater Treatment Plant Upgrades Amendment 04 This amendment is being raised to change the solicitation closing date, distribute bidder questions and answers and make changes to the specifications. CLOSING DATE: The closing date for tender 5P420-16-5057A, titled Lake Louise Wastewater Treatment Plant Upgrades Banff National Park, is extended from June 2, 2016 until June 7, 2016 at 2:00PM Mountain Daylight Time (MDT). NO FURTHER TECHNICAL QUESTIONS WILL BE ACCEPTED FOR THIS TENDER. A) Questions & Answers Q10 Will the KSB KRTK 80‐250/46XG‐S IE2 pump be accepted as an approved alternate to the Flygt NP 3102 MT 3~Adaptive 464 pump? A10 Approved. Q11 Will the KSB Amamix C 2925/06 XDG mixer be accepted as an approved alternate to the Flygt Model 4630 compact mixer? A11 Approved. Q12 Will the Sulzer ABS XFP 100C CB1 pump be accepted as an approved alternate to the Flygt NP 3102 MT 3~Adaptive 464 pump? A12 Approved. Q13 Will the Sulzer ABS XRW 3022 mixer be accepted as an approved alternate to the Flygt Model 4630 compact mixer? A13 Approved. Q14 Will the Kusters Water, WT RDS-135 Perforated Rotary Drum Screen and FSM Screenings Washer Compactor be accepted as an approved equivalent? A14 Not approved. Q15 On drawing 3357-M-01 at the Equalization Tank area, there are two Check Valves and two Isolation (Plug) Valves. Please provide more information regarding their sizes, and provide specifications. A15 All valves within the equalization tank are 100 mm DN. In reference to DWG 3357-M-01 and Specification section 01 10 00 clause 1.3.4, replace the two existing check valves and two plug valves in the equalization tank with an equivalent type. Contractor to match dimensions of existing valve. For the purpose of cost estimating, refer to the following valve specifications: Check valve: Flanged to ANSI/ASME B16.1, bronze disc, ANSI/AWWA C508, expoxy coated inside/outside, iron body bronze mounted (IBBM), swing type gravity operated, 1380 kPa maximum working pressure. Acceptable products: Mueller A-2600-06BB or approved equivalent. Plug Valve: Class 150, flanged to ANSI/ASME B16.1, designed to AWWA C517, shaft seals and plug facing to AWWA C504, ASTM A126 Class B cast iron body and plug, fusion bonded epoxy inside/outside. Acceptable products: Val-Matic, Dezurik, or approved equivalent. Q16 Is there an Approved Vendor list for all the Piping, Fittings, Supports, Gaskets, Studs etc materials. If so please provide the list for all Carbon, PVC, Copper vendor. A16 There is no Approved Vendor for the referenced materials. Bidders may use any reputable supplier as long as the materials meet specification section 44 41 32 for process piping. Page 2 of 5 Solicitation No. - N° de l'invitation 5P420-16-5057/A Amd. No. - N° de la modif. 004 Buyer - l'acheteur Jen Maheu Client Ref. No. - N° de réf. du client 1680-5234-14 File Name - Nom du dossier Lake Louise Wastewater Treatment Plant Upgrades Q17 Please provide more information regarding the Hose Bibbs and Reduced Pressure Principle Backflow Preventer. A17 Hose bibbs by manufacturers such as Mueller, Acorn Engineering or Watts will be acceptable. Provide a 20 mm isolation valve complete with vacuum breaker. Valve bodies to be type 304 or 316 stainless steel. Provide corrosion resistant rack for hose. Refer to contract drawing 3357-M-05. Provide reduced pressure principle backflow preventer assembly such as model 994 by Watts complete with stainless steel body for the main assembly; iron, flanged isolation valves. Size to be 65 mm nominal (smallest in stainless steel). Provide reducers to mate with 50 mm supply and discharge lines. Q18 Please clarify the fire rating and gas tight requirement for the self framing building. Kindly confirm if you only require it for the partition wall? A18 The one-hour fire rating and gas-tightness requirements are for the partition wall only, as indicated in specification Section 13 12 70, clause 1.3.5. The process equipment room on one side is a Class 1 Zone 1 area. On the other side of the partition wall, the electrical room is unrated. Q19 Spec 01 32 18 CONSTRUCTION PROGRESS SCHEDULE, section 1.6 PROJECT MILESTONES., item 1 reference to Mobilize and commence work no later than 30 days after the award of Contract. Please advise what date this Project will be awarded for planning purposes. A19 Due to the potential lead time on equipment PCA will work with the Contractor to allow the Contractor to mobilise to site and commence work in a manner that makes sense to the project. Therefore PCA will relax Specification 01 32 18 Section 1.6.1. PCA's main goal is to have the new Septage Receiving Station (SRS) in place and commissioned by end of May 2017. Q20 A20 What is the fee for a business license? A license costs $98.10 for Banff National Park and it expires on March 31, 2017. B) Tender Package Changes Section 01 32 18 – Construction Progress Schedule Remove: Article 1.6.1 – Mobilize and prepare to commence work no later than 30 days after the award of Contract. Replace with: Article 1.6.1 - Upon Contract award the Contractor will develop a schedule, with Project Milestones, set out in order to have the project complete and the SRS commissioned by the end of May 2017. Section 25 05 03 – Control Panels Remove: Section 25 05 03 – Control Panels Replace with: See revised Section 25 05 03 - Control Panels attached in DSP2. Section 44 41 32 – Process Piping Materials and Methods In: Article 2.1.1 for Line Code E1 Insert the following table (Describes the check and plug valves to be used on the plastic septage transfer discharge lines in the valve chamber adjacent to the equalization tank): ITEM Check Valves SIZES 50 to 200 mm Page 3 of 5 GENERAL DESCRIPTION Description: Flanged to ANSI/ASME B16.1, bronze Solicitation No. - N° de l'invitation 5P420-16-5057/A Amd. No. - N° de la modif. 004 Client Ref. No. - N° de réf. du client 1680-5234-14 File Name - Nom du dossier Lake Louise Wastewater Treatment Plant Upgrades Plug Valves 50 to 200 mm Buyer - l'acheteur Jen Maheu disc, ANSI/AWWA C508, expoxy coated inside/outside, iron body bronze mounted (IBBM), swing type gravity operated, 1380 kPa maximum working pressure. Products:; Mueller A-2600-06BB or, approved alternate. Description: Class 150, flanged to ANSI/ASME B16.1, designed to AWWA C517, shaft seals and plug facing to AWWA C504, ASTM A126 Class B cast iron body and plug, fusion bonded epoxy inside/outside. Products:, Val-Matic, Dezurik or approved alternate. Section 44 61 12 Septage Transfer Pumps Remove: Article 2.1.6 Replace with: Article 2.1.6 Approved products include the following: .1 Flygt NP 3102 MT 3~Adaptive 464 .2 Or equivalent as approved by the Departmental Representative meeting the above specifications Approved products include the following: .1 Flygt NP 3102 MT 3~Adaptive 464 .2 KSB KRTK 80‐250/46XG‐S IE2 .3 Sulzer ABS XFP 100C CB1 .4 Or equivalent as approved by the Departmental Representative meeting the above specifications Section 44 61 93 – Miscellaneous Equipment Remove: Article 2.2.3.1 – Propeller: Cast iron Replace with: Article 2.2.3.1 - Propeller: Type 316 stainless steel Section 44 61 93 – Miscellaneous Equipment Remove: Article 2.2.4 Replace with: Article 2.2.4 Approved products include the following: .1 Flygt Model 4630 compact mixer, .2 Or equivalent as approved by the Departmental Representative meeting the above specifications Approved products include the following: .1 Flygt Model 4630 compact mixer, .2 KSB Amamix C 2925/06 XDG mixer .3 Sulzer ABS XRW 3022 mixer .4 Or equivalent as approved by the Departmental Representative meeting the above specifications Drawing 3357-M-05 The drawing shows hose bibbs using the abbreviation HB and references a reduced pressure principle backflow preventer. Add the following specification notes to the drawing notes: 3) Hose bibbs by manufacturers such as Mueller, Acorn Engineering or Watts will be acceptable. Provide a 20 mm isolation valve complete with vacuum breaker. Valve bodies to be type 304 or 316 stainless steel. Provide corrosion resistant rack for hose. 4) Provide reduced pressure principle backflow preventer assembly such as model 994 by Watts complete with stainless steel body for the main assembly; iron, flanged isolation valves. Size to be Page 4 of 5 Solicitation No. - N° de l'invitation 5P420-16-5057/A Amd. No. - N° de la modif. 004 Buyer - l'acheteur Jen Maheu Client Ref. No. - N° de réf. du client 1680-5234-14 File Name - Nom du dossier Lake Louise Wastewater Treatment Plant Upgrades 65 mm nominal (smallest in stainless steel). Provide reducers to mate with 50 mm supply and discharge lines. Drawing 3357-E-12 Detail 3 Revise the frame from “GH6X2 FL100 ANSI316” to “GX2 EX ANSI316” Revise the modules from RM20, RM30 and RM40 to RM20-EX, RM30 EX and RM40 EX modules. Revise the Stayplate from 120 ANIS 316 to 120 EX ANSI 316 Revise the wedge from 120 ANSI 316 to 120 EX ANSI 316 All other terms and conditions remain unchanged. Page 5 of 5