franche-comte
Transcription
franche-comte
FRANCHE-COMTE A harmonious large shape Large Format Small Curve Tile MORE POWER TO YOUR ROOF 44 cm Base de 5 cm de large FRANCHE-COMTE 26,5 cm Overall dimensions in cm 3 Contour precision 3 Fitting tolerances 3 Curved flow area TECHNICAL CHARACTERISTICS Type Number of tiles per m2 Unit weight Weight per m2 Overall length Overall width Linear cover Theorical gauge Longitudinal fitting tolerance Transversal fitting tolerance Linear metre of battens/m2 Laying Product standard Application standard Silicone product Number of tiles per pallet Weight per pallet TUILES DE TERRE CUITE Classe 1 d’imperméabilité Méthode E d’essais de résistance au gel subis PRESCRIPTION RECOMMENDATION www.marque-nf.com The tile shall be in terracotta, from the large format small curve tile family, Interlocking relief clay tile, large format, double interlocking and double overlap, more or less 12,6 pieces per square meter, double interlocking, double overlap type Franche-Comté from Monier or similar. ≈ 12,6 Its fitting tolerance shall be 1,4 cm long and 0,4 cm transverse. It shall be laid ≈ 3,4 kg in straight joints from right to left, on battens according to the standard ≈ 42,8 kg of the NF P 31-202 [DTU 40-21]. ≈ 44 cm Its installation shall be carried out using all parts specially designed ≈ 26,5 cm for dry mortarless laying of ridges and edges as specified in the DTU. ≈ 21,9 cm ≈ 36,3 cm ± 0,7 cm* 30 YEARS ± 0,2 cm* This tile has been developed and tested in the wind 2,8 ml tunnel at the Monier M Technical Center. FROST Laid with straight joints right to left RESISTANCE CLAY TILES M Class 1 watertightness NF EN 1304 Method E CONCRETE ROOF TILE CONCRETE ROOF TILE freezing resistance trials carried oubis NF P 31-202 [DTU 40.21] * Usual fitting tolerance stated apply from actual average gauges and widths checked on delivery as per DTU. An additive is required for sealing 30 300 For YEARS any projects developed within the context of an HQE® approach, an Environmental 1020 kg and Health Declaration Sheet for this tile is available on request. gUarantEE www.marque-nf.com www.marque-nf.com TUILES DE TERRE CUITE Classe 1 d’imperméabilité Méthode Classe Montagne d’essais de résistance au gel subis www.marque-nf.com FROST RESISTANCE Minimum de 15 mm de large COLOR KEY TUILES DE TERRE CUITE Classe 1 d’imperméabilité Méthode E d’essais de résistance au gel subis www.marque-nf.com Black Red Antique Brown Earth Brown The firing process of the clay may produce slight differences in colour. To obtain a roof with a homogeneous appearance, we recommend mixing tiles from different pallets. The printing processes do not necessarily guarantee a faithful reproduction of colours. Ask to see them in situ. These values are given for information purpose only and are likely to change. www.marque-nf.com the main features veRGEs The wide range of Franche-Comte fittings offers choice of two verge finishes: • verge tile, • standard verge, left and right. Laying with gable tiles Laying with standard verges Gable tiles and tiles Standard verges and tile d= 1±1 16,5±1 6 d= 22,5±1 1±1 multiple of Lc 11,5 multiple of Lc Standard verges, 1/2 tile and tile Gable tile, 1/2 tile and tiles Screw 50 Screw 70 Verges direction is determined by placing them facing the pitch. 24 working height 6 d= 1±1 16,5±1 d= 22,5±1 1±1 multiple of Lc 7 25 9,3 44 25,5 5 working height 11,5 14,5 Dimensions in cm lc = linear cover 15,5 multiple of Lc 14,5 44 13 44 26,5 25,5 43,7 18,2 18,2 16,3 8,5 Standard verge left Verge tile right Verge tile left 43,7 Standard verge right Half tile HIP / RIDGE Monier recommends laying dry with ventilated weather stripping in a roll. Semi round ridge tile 50 3-way apex Ridge board Ridge weather stripping This system enables the ridge and hip to adapt to the nature movements of the roof. Ridge board support Tile Interlocking hip 40 Interlocking hip starter 40 The ridge courses are made by cutting the tiles closest to the ridge board. The dry ridge/hip is quick to lay, provides good ventilation, and makes future work easier. 30 20,8 27 54 24,2 20,8 48,5 46,5 working height small part 8,5 Semi round ridge tile 50 overall height small part 7,2 overall height small part 8 39 overall height small part 7,2 Figaroll® plus (28/32 cm) 4,5 ± 0,5 cm Dimensions in cm All ridges and hips must be fastened with a clip. 22,5 24,2 Semi round ridge tile 33 24,2 Interlocking hip 40 Interlocking hip starter 40 7,2 34,2 13 13 31,2 wakaflex® 18 (18 cm) B Clip for semi round ridge tile 50 wakaflex® 28 (28 cm) 21 Verge pediment with return 21 3 way apex 4 way apex aeration, ventilation AND ILLUMINATION Ø 22 The underside of the tiles and their support must be ventilated. Ventilation guarantees good long-term performance of roofing materials making up the roof. Type of attic The use of ventilation tiles is recommended in the top and bottom sections of the roof. Total ventilation (1) 44 26,5 26,5 S = 1/5 000 Ø int. 16,5 Lantern (Ø 150 mm) The total cross sections of ventilation openings should be distributed evenly (50-50) between the lower section slopes and close to the ridge. Humid or stagnant air coming from ventilation or extracted from inhabited rooms by mechanical or other ventilation must be discharged outside the roof space. Ventilation tile with grid (opening 12 cm2) S = 1/3 000 S = 1/5 000 1 S2 = 1/3 000 (2) For further information on these two points, please consult the DTU in force. S1 = 1/5 000 S2 = 1/3 000 (2) Flange tiles should be installed at the top of the rake. (1) (2) Related to the surface area projected horizontally. Except for Spirtech® type breathing roof underlays. 44 44 26,5 Through tile (Ø 150 mm) 26,5 Glass tile Note : for better performance, the through tiles must be laid as much as possible near ridges. These values are given for information purpose only and are likely to change. THE REGULATIONS Valley and EaveS Minimum pitch table in % D F the main features L Zone I Zone II Zone III The dimension DE mentionned by Monier is given as an example. This dimension will vary according to several parameters : cant height, gauge, roof pitch and overhang d, and may be adjusted to achieve the required overlap. The interlocking part (water flow) must to be taken into account when defining dimensions DE and d. 35 50 70 50 60 80 Minimum acceptable pitches in % (with underlay) Zones Zone I Zone II Zone III Sites Sheltered30 Normal35 Exposed50 30 45 60 45 50 70 These data are applicable to slopes whose horizontal projection does not exceed 12 m. Recommandations of DTU. Zones for the application of minimum pitches France is divided up into 3 zones for the application of minimum pitches (with regard to wind/rain concomitance) Note : if in doubt as to the zone of application, it is essentiall to refer to the definition of the zones given below. Profilo valley Ventilated eaves batten without comb UNDER-ROOF ZONE I All inland areas and the Mediterranean coastline for altitudes of less than 200 m. ZONE II SPIRTECH® 100 SPIRTECH® 200 SPIRTECH® 300 SPIRTECH®+ 200 SPIRTECH®+ 300 - Atlantic coastline up to 20 km inland, from Lorient to the Spanish border. - Strip between 20 to 40 km from the coast, from Lorient to the Belgian border. - Altitudes between 200 m and 500 m SPIRTECH® CLIMA + 200 ZONE III SPIRTECH® BBC 200 SPIRTECH® BBC 300 CLIMA COMFORT RENO® SPAN-FLEX® 200 SPAN-FLEX® 300 - Atlantic, Channel and North Sea coastline and inland to 20 km, from Lorient to the Belgian border. - Altitudes above 500 m and below 900 m. SPAN-ALU 300 Laying tiles in a square layout For violent winds, Monier recommends going beyond the DTU recommendation and therefore fastening all tiles. Definition of sites according to the DTU (1) The wind zones concerned are those provided for in rule NV 65 and sites by the reference DTU. (2) One tile fastened every five tiles laid. Map reference NV65 SITES On verges and eaves, all tiles must be fastened. Use of Europanneton® FCR Inox recommended by Monier. Pitches in % p ≤ 100 100 < p ≤ 175 p > 175 Zones 1 and 2(1) Zones 1 and 2(1) : Exposed site(1) Protected and normal sites(1) Zones 3 and 4 : All sites Verges RunningVerges Running and eaves portion and eaves portion all free all 1/5(2) all 1/5(2)all 1/5(2) all all all all 49 18 Pinecone finial (available in 44,5 cm) 24,5 Ornamental clay cockerel Normal Plain or plateau with slight vertical intervals, whether extensive or not (valleys, undulations). Exposed Near the sea: inland to a distance of 5 km; the tops of cliffs, islands or narrow peninsulas, estuaries or sheltered bays and ria. Inland: narrow valleys into which the wind is channelled, isolated and high mountains (for example: Mont-Aigoual and Mont-Ventoux) and certain mountain passes. This breakdown into three zones should not be confused with the breakdown into Snow and Wind regions given in the NV (Snow and Wind) rules. To prevent ingress of powder snow, the DTU recommends the use of an underlay. This use is also advocated by SNEST in order to catch and lead down to the gutter any small amounts of water as well as to protect against the ingress of dust or soot. ornAments 37 DEFINITION Scheltered Low ground, entirely surrounded by hills which protect it against all wind directions. Site partially bounded by hills in the direction of the most violent winds that provide protection against winds in this direction only. 57,5 18 Fleur de Lys finial Monier reserves the right to change the technical characteristics of its range. Fabienne Alexandre - Export Manager - 67, Avenue de Fontainebleau - 94270 Le Kremlin-Bicêtre - France T : 00 33 1 58 91 20 98 - F : 00 33 1 58 91 21 42 - E : [email protected] Nathalie Bernard - Trade Export Assistant - B.P. 4 - 16270 Roumazières - France T : 00 33 1 41 86 13 88 - F : 00 33 5 45 71 88 93 - E : [email protected] Head office: 67, Avenue de Fontainebleau - 94270 Le Kremlin-Bicêtre T : 01 58 91 20 00 - F : 01 58 91 20 01 www.monier.fr This documentation, which was 04/2012, supersedes all previous issues; it is a non-contractual document that may be revised at any time. Production: DTP: Centaure - Photos: P. Zandvliet - 3D drawings: Buster Studio - X - Centaure LR = Rake length DF = Ridge batten distance = 4,5 ± 0,5 cm DL = Battening distance DE = Eaves batten distance = 35 cm To adjust for the desired overhang. d = Eaves overhang = 8 cm Sheltered35 Normal40 Exposed60 1503 d PEFC/10-31- E Sites D Monier proposes a range of preformed valleys. Laying of a ventilated eaves batten (ventilation 200 cm2/ml) on the tilt batten guarantees linear ventilation in the lower section in accordance with the DTU’s recommendations. Zones • Europanneton FCR Inox for the eaves. ® PROMOUVOIR LA GESTION DURABLE DE L A FORÊ T LR Minimum acceptable pitches in % (no underlay) D All tiles on the eaves must be fastened. Please refer to the DTU in force :