2 pulse outputs module for 2 pulse outputs module for 4 120 53 4
Transcription
2 pulse outputs module for 2 pulse outputs module for 4 120 53 4
87045 LIMOGES Cedex Telephone : 05 55 06 87 87 – Fax: 05 55 06 88 88 2 pulse outputs module for 4 120 53 Cat. N°: 4 120 59 Contents Pages 1. Description - Use................................... 1 2. Range ................................................... ................................ 1 3. Overall dimensions................................ 1 4. Preparation - Connection ...................... 1 5. General characteristics.......................... characteristics 2 6. Compliance and approvals .................... 2 1. DESCRIPTION - USE 4. FIXING - CONNECTION 2 pulse outputs module. Fixing: Allows the remote repetition of the energy counting Each module is equipped with two independent and isolated outputs, associable to the count of active and/or reactive energy, positive and/or negative. 2. RANGE . Cat. N° 4 120 59:: 2 pulse outputs module; associable only to multifunction measuring device 4 120 53. . It is possible to connect a maximum of two modules 4 120 59 obtaining four pulse outputs. Auxiliary supply: . Supplied by the multifunction measuring device 4 120 53 3. OVERALL DIMENSIONS Note: modules must be connected with the device 4 120 53 not supplied. Associability table: Operating position: . Technical data sheet: F02174EN/00 Updated: - Vertical Horizontal Upside down On the side Created: 18/09/2015 1 / 2 2 pulse outputs module for 4 120 53 Cat. N°: 4 120 59 4. FIXING - CONNECTION Screw terminals: 5. GENERAL CHARACTERISTICS Variables associable to the pulse output: (continued) (continued) . Terminal depth: 8 mm. . Stripping length: 8 mm . Positive active energy (Ea+) . Positive reactive energy (Er+) . Negative active energy (Ea-) . Negative reactive energy (Er-) Screw head: . Screw slotted. Pulse output’s characteristics: Recommended tightening torque: . 0,6 Nm. Tools required: . Optorelays with potential-free SPST-NO contact . Type S0 (IEC/EN62053-31) . Voltage U : max. 27 Va.c./d.c. . Current I : max. 50 mA . Programmable pulse weight, possible values: 10 – 100 - 1k - 10k 100k - 1M - 10M Wh/imp or varh/imp . Programmable pulse duration, possible values: 50 - 100 - 200 - 300 ms. imp . For terminals: flat screwdriver 3,5 mm . For fixing the modules to the measuring device: flat screwdriver max. 5 mm. Connectable section: section: . Copper cables. imp Plastic material: Without ferrule With ferrule Rigid cable 0,05 to 4,5 mm² - Flexible cable 0,05 to 2,5 mm² 0,05 to 2,5 mm² . Self-extinguishing polycarbonate. Ambient operating temperature: . Min. = - 5 °C Max. = + 55 °C. Ambient storage temperature: Wiring diagrams: . Min. = - 25 °C Max. = + 70 °C. . Terminals identifications Impulse withstand voltage: . Supply / Out 1 - Out 2: alternate current 50 Hz / 1 min.: 2 kV . Measuring inputs / Out 1 - Out 2: alternate current 50 Hz / 1 min.: 2 kV Note: values referred to combination measuring device + add-on module. Average weight per device: . 0,030 kg. Volume when packed: . 0,30 dm3 . Wirings Consumption: . Module 4 120 59: ≤ 1 VA . Measuring device 4 120 53 + 1 Module 4 120 59: ≤ 5 VA . Measuring device 4 120 53 + 2 Modules 4 120 59: ≤ 6 VA 6. COMPLIANCE AND APPROVALS Compliance to standards: 5. GENERAL CHARACTERISTICS Terminals marking: . Compliance with Directive on electromagnetic compatibility (EMC) n° 2004/108/EC . Compliance with low voltage directive no. 73/23/CEE dated 19 February 1973, modified by directive no. 93/68/CEE dated 22 July 1993, modified by directive n° 2006/95/CE. . By permanent ink pad printing. Technical data sheet: F02174EN/00 Updated: - Created: 18/09/2015 2/2