L5000-RS422 Communications Module INSTALLATION GUIDE
Transcription
L5000-RS422 Communications Module INSTALLATION GUIDE
800-10232 Rev. A 10/11 L5000-RS422 Communications Module INSTALLATION GUIDE About the Communications Module The L5000-RS422 communications module is intended to provide connection between compatible Safewatch QuickConnect Touch or Honeywell control panels and the ADT Pulse Interactive Solutions Pulse Gateway. NOTE: ADT’s internet service not evaluated by ETL. Compatible Controls Control QuickConnect Touch LYNX Touch Installation Guide 800-10044 or higher 800-10044-1 or higher The module connects directly to the control panel and is powered via the control panel’s connection. It is connected to the Pulse Gateway via the provided cable and the Pulse Gateway RS422 terminals. Mounting the Module Mount the module in the control panel as shown in Figure 1. Ensure that module’s receptacle is securely seated on the control’s edge connector. L5000-RS422 CABLE ASSEMBLY RECEPTACLE EDGE CONNECTOR LYNX TOUCH 5000-100-206-V0 Figure 1. Installing the L5000-RS422 Communications Module Wiring the Module 1. Plug the connector end of the provided 5-wire cable into the receptacle on the L5000-RS422 Communications Module as shown in Figure 1. 2. Route the cable as shown on Figure 2 and secure with tie wraps. 3. Connect the four TX and RX wires of the provided 5-wire cable to the appropriate RS422 TX and RX terminals on the Pulse Gateway as shown in Figure 2. Note: If additional wire is required in order to connect the L5000-RS422 module to the Pulse Gateway, do not exceed 200 ft maximum using 24AWG wire. TIE WRAPS RS422 CONNECTIONS GND TX TX RX RX to iHub RX to iHub RX to iHub TX to iHub TX BLACK ORANGE WHITE/ORANGE GREEN WHITE/GREEN L5000-RS422 CABLE L5000-RS422 CABLE Pulse Gateway 5000-400-208-V0 Figure 2. L5000-RS422 Cable Connections Programming Notes Programming associated with the L5000-RS422 module is accomplished as part of the Control Panel Programming. Refer to the Control Panel Installation and Setup Guide for additional information. 1. The Remote Access Serial option must be set to “Enabled”. 2. The Multi Mode Serial option must be set to “Enhanced Reports”. Specifications Board Dimensions: Current Drain: Input Voltage: Wire Run Length: Temperature: 1.25” W x 2.875” L x 0.3125” D 15mA nominal; 60mA max 3.3VDC supplied by the control panel 200 ft max with 24 AWG unshielded wire 32°F (0°C) to 140°F (60°C) REFER TO THE INSTALLATION AND SETUP GUIDE FOR THE CONTROL WITH WHICH THIS DEVICE IS USED FOR WARRANTY INFORMATION AND LIMITATIONS OF THE ENTIRE SYSTEM. ADT Security Services, Inc. One Town Center Road Boca Raton, FL 33486 Copyright © 2011 Ê800-10232YŠ 800-10232 10/11 Rev. A