L5000-RS422 Communications Module INSTALLATION GUIDE

Transcription

L5000-RS422 Communications Module INSTALLATION GUIDE
800-10232 Rev. A 10/11
L5000-RS422
Communications Module
INSTALLATION GUIDE
About the Communications Module
The L5000-RS422 communications module is intended to provide connection between compatible
Safewatch QuickConnect Touch or Honeywell control panels and the ADT Pulse Interactive Solutions
Pulse Gateway.
NOTE: ADT’s internet service not evaluated by ETL.
Compatible Controls
Control
QuickConnect Touch
LYNX Touch
Installation Guide
800-10044 or higher
800-10044-1 or higher
The module connects directly to the control panel and is powered via the control panel’s connection.
It is connected to the Pulse Gateway via the provided cable and the Pulse Gateway RS422 terminals.
Mounting the Module
Mount the module in the control panel as shown in Figure 1. Ensure that module’s receptacle is securely
seated on the control’s edge connector.
L5000-RS422
CABLE
ASSEMBLY
RECEPTACLE
EDGE CONNECTOR
LYNX TOUCH
5000-100-206-V0
Figure 1. Installing the L5000-RS422 Communications Module
Wiring the Module
1. Plug the connector end of the provided 5-wire cable into the receptacle on the L5000-RS422
Communications Module as shown in Figure 1.
2. Route the cable as shown on Figure 2 and secure with tie wraps.
3. Connect the four TX and RX wires of the provided 5-wire cable to the appropriate RS422 TX and RX
terminals on the Pulse Gateway as shown in Figure 2.
Note: If additional wire is required in order to connect the L5000-RS422 module to the Pulse Gateway, do
not exceed 200 ft maximum using 24AWG wire.
TIE
WRAPS
RS422
CONNECTIONS
GND
TX
TX
RX
RX
to iHub RX
to iHub RX
to iHub TX
to iHub TX
BLACK
ORANGE
WHITE/ORANGE
GREEN
WHITE/GREEN
L5000-RS422 CABLE
L5000-RS422
CABLE
Pulse Gateway
5000-400-208-V0
Figure 2. L5000-RS422 Cable Connections
Programming Notes
Programming associated with the L5000-RS422 module is accomplished as part of the Control Panel
Programming. Refer to the Control Panel Installation and Setup Guide for additional information.
1. The Remote Access Serial option must be set to “Enabled”.
2. The Multi Mode Serial option must be set to “Enhanced Reports”.
Specifications
Board Dimensions:
Current Drain:
Input Voltage:
Wire Run Length:
Temperature:
1.25” W x 2.875” L x 0.3125” D
15mA nominal; 60mA max
3.3VDC supplied by the control panel
200 ft max with 24 AWG unshielded wire
32°F (0°C) to 140°F (60°C)
REFER TO THE INSTALLATION AND SETUP GUIDE FOR THE CONTROL WITH WHICH THIS DEVICE IS
USED FOR WARRANTY INFORMATION AND LIMITATIONS OF THE ENTIRE SYSTEM.