Site Specific

Transcription

Site Specific
NOT PROTECTIVELY MARKED
BEG/SPEC/OPSV/EPG/002/016
Revision 003
Page 1 of 6
Nuclear Generation Limited
Company Specification
Generic Emergency Handbook
(Nuclear Generation)
Section 16 Emergency Equipment
Originated by:
John Babb
Emergency Planning Group
Date: January 2013
Reviewed by:
EP Peer Group
Date: January 2013
Approved by:
John Skegg
Head of Emergency Planning Group
Date: January 2013
Revision
Amendment
Impact level
Date
003
Document converted to current EDF NG template
Changes include company name and organisational
updates
Minor
January 2013
© 2013 Published in the United Kingdom by EDF Energy Nuclear Generation Ltd.
All rights reserved. No part of this publication may be reproduced or transmitted in any form or by any means, including photocopying and recording,
without the written permission of the copyright holder, EDF Energy Nuclear Generation Ltd, application for which should be addressed to the publisher.
Such written permission must also be obtained before any part of this publication is stored in a retrieval system of any nature. Requests for copies of this
document should be referred to Barnwood Document Centre, Location 12, EDF Energy Nuclear Generation Ltd, Barnett Way, Barnwood, Gloucester GL4
3RS (Tel: 01452-652791). The electronic copy is the current issue and printing renders this document uncontrolled. Controlled copy-holders will continue
to receive updates as usual.
LIMITATION OF LIABILITY – Whilst EDF Energy Nuclear Generation Ltd believes that the information given in this document is correct at the date of
publication it does not guarantee that this is so, nor that the information is suitable for any particular purpose. Users must therefore satisfy themselves as to
the suitability of the information for the purpose for which they require it and must make all checks they deem necessary to verify the accuracy thereof.
EDF Energy Nuclear Generation Ltd shall not be liable for any loss or damage (except for death or personal injury caused by negligence) arising from any
use to which the information is put.
NOT PROTECTIVELY MARKED
Parent Document Ref: BEG/ICP/QUA/DM/003
Template Ref: BEG/FORM/QUA/002 Rev 022
NOT PROTECTIVELY MARKED
BEG/SPEC/OPSV/EPG/002/016
Revision 003
Page 2 of 6
Contents
16.1
Emergency Control Centre And Alternative Emergency Control Centre.................. 3
16.2
Central Control Room / Main Control Room............. Error! Bookmark not defined.
16.3
Muster Points ......................................................................................................... 3
16.4
On-Site Survey Vehicle........................................................................................... 4
16.5
Equipment List: Off-Site Survey Vehicle ................................................................. 5
16.6
Access Control Point .............................................................................................. 6
16.7
Incident Response Team........................................................................................ 6
16.8
Standby Emergency Response Team .................................................................... 6
16.9
First Aid And Medical Decontamination Centres ..................................................... 6
16.10
Gatehouse.............................................................................................................. 6
16.11
Breathing Apparatus............................................................................................... 6
16.12
FLASK/NAIR .......................................................................................................... 6
16.13
Miscellaneous......................................................................................................... 6
edfenergy.com
NOT PROTECTIVELY MARKED
NOT PROTECTIVELY MARKED
16.1
BEG/SPEC/OPSV/EPG/002/016
Revision 003
Page 3 of 6
Emergency Control Centre And Alternative Emergency Control Centre
(Site Specific)
16.2
Central Control Room / Main Control Room
(Site Specific)
16.3
Muster Points
(Site Specific)
edfenergy.com
NOT PROTECTIVELY MARKED
NOT PROTECTIVELY MARKED
16.4
BEG/SPEC/OPSV/EPG/002/016
Revision 003
Page 4 of 6
On-Site Survey Vehicle
Dedicated electric enclosed vehicle or near equivalent
UHF radio
Air sampler (R&M EASL 50 12v)
Air sample volume meter (see Off-Site Survey list for details)
Timer
NE 710 BP4 castle (set of 10% 4 using BNL C1-36 Maypack source)
Mini Instruments 6-90 scaler (with modification to give 899.99 fsd)
100 : 1 attenuator
Castle Maypack jig
Castle GFA air sample counting tray
Maypack air sample adaptor
Normal GFA air sample head
Dose rate meter type RO2
Dose rate meter type RM5/BP4
Dose meter type ......
20 Maypacks in sealed containers
BNL C1-36 check-source Maypack
CO2 detector
Respirators with charcoal filters
Waterproof nylon coveralls with hoods
PVC overshoes
Rubber gloves
Disposable gloves
Safety helmets
Pens
50 x forms EP/10.2/2
25 x preliminary sample forms EP/10.2/1
On-site Survey sample point map
Torch and spare batteries
10 Potassium Iodate tablets and water
Assorted polythene bags
Installed BA bottle trolley system
2 x escape BA sets
edfenergy.com
NOT PROTECTIVELY MARKED
NOT PROTECTIVELY MARKED
16.5
BEG/SPEC/OPSV/EPG/002/016
Revision 003
Page 5 of 6
Equipment List: Off-Site Survey Vehicle
Suitable vehicle with amber beacon and internal fluorescent lights
Air Sampler (R & M EASL 50, 12v)
Air Sample Volume meter (Parkinson Cowen Gasmeter U6 synthetic diaphragm without CLWs
m scale)
(delete “m3”) and decimal point from scale to give litres)
NE 710 BP4 Castle (set to 10% Eff using BNL Cl-36 Maypack) with PB4/4 probe
Mini Instruments Type 6 – 9 (modified 6-90) scaler (set for operation with NE Technology probe
BP4/4).
100 : 1 Attenuator
Castle Maypack Jig
Maypack air sample adaptor
NE PDR1 dose rate meter
NE PDR2 dose rate meter
DRCD
20 Maypacks (Centrally assembled)
BNL C1 – 36 Check-source Maypack to give 1,000 cps (all sites and vehicles to have BNL
sources giving the same count rate).
2 x Waterproof Nylon coveralls (06/06/09 – series)
10 prs PVC overshoes
100 prs Disposable gloves
Large self-seal polythene bags
6 x pens
50 Forms
1 : 2500 Map showing Off-site Sampling Points/Sample Point Schedule and descriptions
1 Box Potassium Iodate tablets
1 Bottle Water
1 10 min Timer
1 Radio
1 Fire Extinguisher
1 First Aid Kit
When supporting other sites the following additional equipment will be carried
1.
Reception Centre kit as listed in EP/10/9/2
2.
District Survey kit as listed in EP/8.2.6
edfenergy.com
NOT PROTECTIVELY MARKED
NOT PROTECTIVELY MARKED
16.6
BEG/SPEC/OPSV/EPG/002/016
Revision 003
Page 6 of 6
Access Control Point
(Site Specific)
16.7
Incident Response Team
(Site Specific)
16.8
Standby Emergency Response Team
(Site Specific)
16.9
First Aid And Medical Decontamination Centres
(Site Specific)
16.10 Gatehouse
(Site Specific)
16.11 Breathing Apparatus
(Site Specific)
16.12 FLASK/NAIR
(Site Specific)
16.13 Miscellaneous
(Site Specific)