TECHNICAL CHARACTERISTICS
The photograph may not match the reference
exactly. Please read the product description to
identify the finish.
Type:
Pendant
IP Protection degrees:
IP20
Location:
DRY
Light source 1:
1 x E26
MAX 100W
Maximum lamp length: 200.00 mm
Maximum lamp diameter: 150.00 mm
Total power consumption (W):
100
Voltage / Frequency:
120V/60Hz
Units per box:
1
Pes net (lb):
8.28
EAN:
8435381436933
MATERIALS / FINISHES
Download photometric file .ldt /.ies
Structure
material:
Steel
Polycarbonate
Diffuser material: ABS
Structure finish:
Matt white
Transparent
Diffuser finish:
LEDS-C4 reserves the right to make the necessary technical changes they deem adequate, in order to improve the features of
the product.
Please consult the sales team to clarify any doubt.
White
(+34) 973 468 100
[email protected]
www.leds-c4.com
Luminaire
Code
00-3543-BW-BW
Name
Colgante ANGIE 100W A55 E27
Line
- LEDS-C4
Measurem.
Code 00-3543-BW-BW
Name Colgante ANGIE 100W A55 E27
Date 12-06-2015
Lamp
Code
Number
Position
Efficiency
45.83%
Coordinate system
CG
Total Flux
Maximum value
242.79 cd
Position
C=15.00 G=25.00
Double Symmetrical
500 mm
280 mm
Height
Height
STANDAR GOC 100W O
1
Universal
1340.00 lm
Round Luminaire
Round Luminous Area
Diam.
Diam.
Horizontal Luminous Area
Emitting area on Plane 0°
Emitting area on Plane 90°
0.061575 m2
0.000000 m2
0.000000 m2
Emitting area on Plane 180°
Emitting area on Plane 270°
Glare area at 76°
0.000000 m2
0.000000 m2
0.014896 m2
Symmetry Type
Measurement Distance
Double Symmetrical
6.44
Maximum Gamma Angle
Measurement Flux
180
1271.00 lm
Operator
Temperature
Humidity
Notes
Asselum T2
25.00 °C
54.00 %
Source voltage
Source current
Photocell
230.00 V
Prc
Luminaire Lamps
Code
Name
STANDAR GOC 100W O
STANDAR GOCCIA 100W E27 OPALE
Line
PHILIPS 2005 ILCOS IA,IB,IC
C.I.E.
F UTE
440 mm
0 mm
55 79 94 86 46
0.39 D + 0.06 T
D DIN 5040
B NBN
Flux [lm]
1340.00
Pow. [W] Q.ty
100.00
1
B41
BZ 3 / 0.8 / BZ 4
Diam=500mm
90
Gamma Angles
180°
120°
0
50
105°
105°
180
270
90°
90°
C Halfplanes
180.0
0.0
270.0
90.0
50
75°
75°
100
60°
60°
150
ULOR
6.46 %
DLOR
39.37 %
RN
14.10 %
45°
45°
200
cd
250
30°
LITESTAR
(c)OxyTech Srl www.oxytech.it
15°
0°
15°
30°
Page 1
LEDS, C4 S.A.
CIF/VAT: A-59.410.910
C/ Afueras s/n -TORA- 25750
(LLEIDA) SPAIN
TEL: 34 (73) 46 81 02
FAX: 34 (73) 46 81 06
SHEET: 1/1
EDITION: 01
REF: 00-3543U
FIGURE Nº 1. UNPACK THE FIXTURE: CHECK THE
CONTENTS OF THE BOX. YOU SHOULD RECEIVE:
FIGURE Nº 1. DÉBALLER LE PLAFONIER: VÉRIFIER LE
CONTENU DU CARTON, VOUS DEVEZ RECEVOIR:
FIGURE 7
FIGURE 6
FIGURE 8
INSTALLATION INSTRUCTIONS FOR
HANGING FIXTURES
FIGURE 3, 4 AND 5 MOUNTING HARDWARE.
NOTE: TEST THE CONNECTOR BY GENTLY PULLING IT. IF IT PULLS OUT THE CONNECTION, TRY
AGAIN TILL YOU HAVE A FIRM CONNECTION. MAKE SURE NO BARE STRANDS OF WIRE STICK OUT
FROM UNDER THE CONNECTORS.
WHITE OR MARKED WIRE
FROM FIXTURE
WHITE WIRE FROM
OUTLET BOX
FIGURE 3
BLACK OR UNMARKED WIRE
BLACK
FIGURE 4
FIGURE 5
INSTRUCTIONS D'INSTALLATION POUR
PLAFONIERS
FIGURE 3, 4 ET 5 MONTAGE DE L'ÉQUIPE.
IMPORTANT: ESSAYER DE TIRER LE CÂBLE D'ALIMENTATION DOUCEMENT.S'IL SORT DE LA
CONNECTION, IL FAUDRAIT ASSURER QUE LA CONNECTION SOIT FERME. S'ASSUSER QUE LES FILS
DES CÂBLES NE SONT PAS À DÉCOUVERT DU CONNECTEUR.
CÂBLE BLANC OU MARQUÉ
DU PLAFONIER
CÂBLE BLANC DE LA BOÎTE
FIGURE 3
CÂBLE NOIRE OU
NOU-MARQUÉ
FIGURE 4
NOIRE
FIGURE 5
CAUTION:
ATTENTION:
"Warning", "This product is to be
installed by a qualified electrician
only."
"Suitable for dry locations only"
"Attention", le raccordement
électrique sera effectué par un
téchnicien électricien qualifié"
"Adéquat seulement en lieux secs."
CAUTION:
1.- Wrong lighting installation can be dangerous for your safety.
2.- Before starting, disconnect the power by turning off the general switch of the
electric installation.
3.- Install light bulbs (not provided) that must not exceed markings on the fixture.
4.- To change the bulbs, disconnect the power by turning off the general switch and
wait for the bulbs cool down.
INSTALLATION:
1.- Make electrical connections, carefully read the Electrical Connection section.
2.- Assemble lighting onto the outlet box as shown on fig. 6, & 7.
ELECTRICAL CONNECTIONS: (See fig. 3,4 y 5)
1.- Connect the white wire from the fixture to the white wire of the electric installation.
2.- Connect the black wire from the fixture to the black wire of the electric installation.
3.- Connect the grounding conductor from the fixture to the grounding wire of the
electric installation.
4.- Spread out the electrical wires so that the black ones are on one side of the outlet
box and the white ones are on the other side, and carefully introduce them into the
outlet box.
ATTENTION:
1. Une mauvaise installation peut compromettre votre sécurité.
2. Déconnecter la tension du réseau d'alimentation avant de réaliser toute opération.
3. Installer les ampoules (non fournies), ne pas utiliser d'ampoules d'un autre type ou
d'une puissance supérieure à celle indiquée sur l'étiquette de la lampe.
4. Pour changer les ampoules, déconnecter la tension du réseau d'alimention et
laisser refroider les ampoules.
INSTALLATION:
1. Connecter au réseau, lire attentivement la section de "Raccordements électriques"
2. Installer l'appareil à la boîte de distribution comme indiqué dans les dessins 6 et 7.
RACCORDEMENTS ÉLECTRIQUES (dessins 3,4 et 5)
1. Connecter le câble blanc de l'appareil au câble blanc de l'installation électrique.
2. Connecter le câble noir de l'appareil au câble noir de l'installation électrique.
3. Connecter le câble conducteur de prise de terre au câble de prise de terre de
l'installation électrique.
4. Distribuer les câbles pour que tout le câblage noir soit par dehors et le câblage
blanc soit par dedans. Ajuster et immobiliser à la boîte sans coincer aucun câble.