Micro Lab Lit Sept04
Transcription
Micro Lab Lit Sept04
MicroLab The world’s most versatile portable Spirometer MicroLab A new generation Spirometer designed for the professional Child incentive animatio In-built high resolution printer MicroLab Cat. No. ML3500 Features Developed for the professional, the new • High resolution printer generation MicroLab employs Micro Medical’s • Text entry, enabling comment writing acclaimed precision Gold Standard Digital Volume Transducer which is especially suited to measuring very low flow rates in patients with COPD. • Internationally recognised on-screen test quality assurance prompts for poor test attempts (e.g. slow start, abrupt end etc.) • Bronchodilator and/or steroid assessment The MicroLab has a class-leading, very high resolution screen and can display both Volume/Time and complete Flow/Volume Loops (using either the open or closed loop test techniques).The instrument can measure up to 36 • Predicted value and language selection • Body mass index and dyspnoea score calculation • Lung age assessment and textual result interpretation by ATS10, BTS-NICE11 or Enright12 parameters and has a database storage capacity for over 1000 patients. A built-in high resolution printer delivers hard copy results. A4 sized • Fully customisable printout format • Complete with all accessories in a sturdy carry case printouts can be obtained directly via Hewlet Packard or Canon printers. (compatible models specified by Micro Medical). • Optional Spida 5 spirometry PC software • SpidaXpert interpretation and diagnostic upgrade available for Spida 5 A new child incentive graphical display is featured and an optional Airway Resistance measurement module is offered. Offered as an option for MicroLab is Spida 5, a powerful Spirometry PC software package. Available as an upgrade for Spida 5 is SpidaXpert, an advanced interpretation and diagnostic Text and number entry keys program for spirometry. A new child incentive graphical display is featured and an optional Airway Resistance measurement module is offered. A comprehensive range of advanced features normally only seen on more expensive laboratory Setting new standards in spirometry based equipment are included in MicroLab (of The new Gold Standard transducer from Micro Medical gives the most pr measurements for your Asthma and COPD patients. which there are more than 40,000 units in use around the world). Especially effective at low flows, it complies with all current ATS and othe for accuracy. This means that Micro Medical’s world beating spirometers accurate respiratory measurement - bar none. The new generation of portable precision Spirometers are here – NOW ! Digital Volume Transducer Spirometers are NOT ALL THE SAME ive animation Built-in internationally recognised test quality prompts Audio alarm 1. Open loop spirometry 6. Comprehensive results screen 2. Closed loop spirometry 7. Patient data entry screen 3. Relaxed inspiratory/expiratory 8. Airway resistance results screen High Visibility Screen Screen function keys Screen navigation keys vital capacity (with optional MicroRint module) Rechargeable battery Indicator light 4. Simple parameter selection 9. Airway Resistance waveform (with optional MicroRint module) es the most precise volume and flow ATS and other recognised international standards spirometers are the definitive benchmark for L THE SAME. 5. Easy system customisation Spida 5 - SpidaXpert Very user-friendly, advanced features Spida 5 is the highest quality advanced Spirometry software you can buy.The 32-bit package is simple to use and employs a state Fully searchable Patient Database Animated child incentive window Previous tests of the art multi-window, screen interface. Best volume time curve Up to 41 Spirometry indices can be measured, previous test curves overlaid for comparison and both open and closed Flow/Volume Loop test techniques used. Three types of animated child incentive devices and the long term trending of patient results also feature Spida 5 can be easily linked to other patient journal or GP administration systems, occupational health systems or other medical databases. Spida 5 is compatible with Microsoft Windows 95, 98, 2000, Me, XP and NT and will link to all Micro Medical Spirometers* Offered as an optional upgrade for Spida 5 is SpidaXpert a comprehensive, quality assurance, interpretation and diagnostic software program for spirometry. Developed in partnership with a prestigious group of Dutch Respiratory Physicians13, SpidaXpert automatically assesses the quality and reproducibility of the spirometry tests according to international standards. Concise analysis and diagnosis is achieved using clear coloured graphical Results analysis Predicted area Amendable notes Spida 5 Cat. No. SD5000 indicators and comprehensive textual interpretation. Features SpidaXpert which includes all the features of Spida5, is a powerful support tool, a true physicians friend. • Multi-window layout is extremely easy and fast to use • Animated child incentive display • Real-time Flow/Volume and Volume/Time traces • Open and closed Flow/Volume loop test technique is possible System Requirements • Overlaying of previous test curves for comparison • Processor: Pentium 133 MHz • Long term trending facility • Ram: 32 MB • CD-ROM: 4x or faster • Free Disk Space: 50MB • Video: SVGA 800x600, 256 colours • One free serial port for standard Spirometers • One free USB port and USB Supported Operating System, for USB enabled Spirometers. * Spida 5 and SpidaXpert are compatible with all Micro Medical spirometers except the Micro and Micro DiaryCard. • Lung age calculation and textual interpretation • Powerful search capability • Up to 41 spirometry parameters can be measured • Can be easily linked to other patient journal or GP administration systems, occupational health systems or other medical databases • Configurable printout format • SpidaXpert interpretation and diagnostic upgrade available for Spida 5 (Cat. No. SD5000XP) or as a complete product including Spida 5 features All flow volume loops Best flow volume loop MicroRint A simple test to measure airway resistance Available for MicroLab is the optional MicroRint module for the easy measurement of airway MicroRint Module Cat. No. MRT6000 resistance. Features Micro Medical’s unique design has taken a hitherto specialised measurement out of the pulmonary function laboratory and into the clinic or home. MicroRint enables airway resistance to be • Rechargeable battery or mains usage • Bacteriological viral filters to eliminate cross infection fears • Predicted values with pre-and post- bronchodilator analysis • Configurable measurement methodology without effort or technique from the patient.The • 1000+ test memory with results printout direct to Canon or Hewlett Packard printers – compatible models specifiied by Micro Medical subject simply breathes passively through a • Optional Rida, database and analysis software measured with the same ease as peak flow but mouthpiece or facemask.The result is automatically computed and displayed against predicted normal values.The procedure, that can be performed on neonates to adults, takes only a few minutes. Available as an option for the MicroRint module is Rida, a comprehensive database and analysis software package. In this method airway resistance is determined by a momentary interruption to flow (Q) in the airways. At this point alveolar pressure (Pa) equilibrates with the pressure in the airways and the mouth (PaO) and airway resistance (kPa/1/s) is calculated from PaO/Q (pressure/flow). Results using MicroRint correlate well with other airway resistance methods7 and with other measurements of lung function such as FEV1.8 To know more about MicroRint please visit www.micromedical.co.uk Bibliography Specifications 1 Dirksen A, Madsen F, Pedersen OF,Vedel AM, Jenson AK. Spirometry Long term performance of a hand held Spirometer.Thorax Measurements: VC, FEV0.75, FEV1, FEV3, FEV6, FVC, PEF FEV0.75/VC, FEV0.75/FVC, FEV1/VC, FEV1/FVC, 1996;51:973-976. FEV3/VC, FEV3/FVC, FEV0.75/FEV6, FEV1/FEV6, MEF75, MEF50, MEF25, MEF25-75, Tests per subject: FEF50/VC, FEF50FVC, MVVind, FET, MET, IC, FIV1, FIVC, PIF, FIV1,/FIVC, FIF25, FIF50, 2 Otulana BA, Higenbottam T, Ferrari L.The use of home FIF75, FIF50/MEF50,VT, ERV, IRV [all expiratory measurements with baseline, post Spirometry in detecting acute lung rejection and infection bronchodilator 1 and 2, % predicted, % change and normal range] following heart-lung transplantation. Chest 1990;97:953-7. VC-unlimited (best reported) FVC-unlimited (best 3 from baseline, post 1 and post 2 tests) 3 Pollard AJ, Mason NP, Barry PW, Pollard RC, Collier DJ, Fraser RS, Miller MR, Milledge JS. Effect of altitude on spirometric parameters and the performance of peak flow Predicted Values: Various – depends upon national preference (Including NHANES III) Transducer: Micro Medical Gold Standard Bi-Directional Digital Volume Resolution: 10ml volume 0.03l/s flow Accuracy: +/-3%.To ATS recommendations – Standardisation of spirometry 1994 update for meters.Thorax 1996;51:175-178. 4 Godschalk, L, Brackel HJL, Peters JCK, Bogaard JM. Assessment of accuracy and applicability of a portable electronic diary card Spirometer for Asthma treatment. Respiratory Medicine, 1996;90:619-622. flows and volumes 5 Morris JF,Temple W. Spirometric ‘Lung Age’ estimation for motivating smoking cessation. Preventative Medicine, 1995;14 655-662. General 6 BTS Guidelines for the management of Chronic Storage : 1000 patients’ tests including Flow/Volume loops and Volume/Time curves Printer Output: For the latest listing of compatible Canon and Hewlett Packard printers please visit Group of the Standards of Care Committee of the BTS) the Micro Medical website at www.micromedical.co.uk Thorax 1997;53 (Suppl 5):S4-6. Display: High resolution graphic LCD 240x160 pixels Power Supply: 100-240V, 0.5A, 50-60Hz. Output 9V 1.12A (Class 1) Battery Pack: Rechargeable NiMH 7.2V 1A-HR Dimensions: 150 x 251 x 40 mm.Transducer 50 x 60 x 90mm Weight: Unit weight 0.75kg. Packed weight 2.55kg Obstructive Pulmonary Disease (The COPD Guidelines 7 Wilson CM, Bakewell SE, Mr Miller etal.Increased resting bronchial tone in normal subjects acclimatised to altitude. Thorax 2002, 57: 400-404. 8 Bent Klug and Hans Bisgaard. Measurement of Lung Function in Awake 2-4 Year-Old Asthmatic Children During Methacholine Challenge and Acute Asthma. Paediatric Pulmonology 21:290-300 (1996). Temperature: 0 0 0 to +40 C 9 Edward R. Carter, Arlene A. Stecenko, Brad H. Pollock, Marc J. Jaeger. Evaluation of the Interrupter Technique for the Use of Assessing Airway Obstruction in Children. Paediatric Pulmonology 17:211-217 (1994). Operating Humidity: 30% to 90% RH 0 0 Storage Temperature: 0 to +70 C 10 American Thoracic Society. Standardization of spirometry: 1994 update. Am J Respir Crit Care Med 1995; 152: 1107-1136. Storage Humidity: 10% to 90% RH 11 National clinical guideline on management of chronic obstructive pulmonary disease in primary and secondary care (National Institute of Clinical Excellence (NICE) /British Thoracic Society (BTS) Thorax 2004;59(Suppl l): 1-232 doi: The MicroLab (Cat. No. ML3500 ) is part of an extensive range of respiratory monitoring equipment manufactured by Micro Medical Ltd. Micro Medical Ltd pursues a policy of continuing improvement in design, production and performance of its products.The right is therefore reserved to vary details at any time and without notice. 10.1136/thx.2004.022707 12 Office spirometry, a practical guide of the selection and use off spirometers. Paul Enright 13 Members of the Dutch consensus group can be found by visiting ww.spirxpert.com/spirxpertgroup.htm Micro Medical Limited PO BOX 6, Rochester, Kent, ME1 2AZ, UK Telephone 01634 893500 Fax 01634 893600 International +44 1634 893500 Email [email protected] www.micromedical.co.uk ML3500 09/04