Résumés
Transcription
Résumés
N ° 2 6 1 - Av r i l / A p r i l 2 0 1 2 N°261 - Avril / April 2012 >>> Résumés Abstracts © alphaspirit.folio.com SUMMARY – TB N° 491 - WG A1.16 Generator End-Winding Retaining Rings – A Literature Survey and Care Guideline Proper care and management of generator rotor end-winding retaining rings, the most highly stressed component of a generator, is essential to avoid failure, and potential resultant damage to other generator parts and harm to power plant personnel. This guideline recommends precautions to be taken to prevent such failures, and details tests and inspections, as well as guidance to developing end ring management policies and strategies. RESUME – BT N° 491 - GT A1.16 Capots d’extrémité des générateurs: une analyse bibliographique et un guide de maintenance Une maintenance et une gestion adaptées des capots d’extrémité des générateurs, qui sont le composant le plus contraint d’un générateur, sont essentielles pour éviter les défaillances, avec des risques de dommages sur les autres parties du générateur, ainsi que des blessures du personnel de la centrale. Ce guide présente les précautions recommandées pour prévenir ces défaillances, et précise les essais et les inspections, ainsi que les directives pour mettre au point des politiques et des stratégies de gestion des capots d’extrémité. SUMMARY - TB N° 492 – WG B4.46 Voltage Source Converter (VSC) HVDC for Power Transmission – Economic Aspects and Comparison with other AC and DC Technologies The objective of the WG was to develop an assessment process to evaluate the beneficial impact of VSC-HVDC on power systems. The proposed methodology includes a straightforward analysis of important environmental facts that have to be taken into account for an appropriate assessment. Case studies have been provided in order to demonstrate the application of the proposed methodology. This WG gives a snapshot on the current technology, application areas and economic values. With ongoing developments it can be expected that VSC-HVDC will become even more attractive for bulk power transmission and might become an economic feasible alternative to other technologies. RÉSUMÉ - BT N° 492 – GT B4.46 Convertisseurs à source de tension (VSC) CCHT pour le transport d’électricité – Aspects économiques et comparaisons avec les autres technologies CA et CC L’objectif du GT est de développer un processus d’évaluation pour estimer l’impact bénéfique des systèmes VSC CCHT sur les systèmes électriques. La méthodologie proposée comporte une analyse directe d’éléments environnementaux importants que l’on doit prendre en compte pour réaliser une évaluation adéquate. Des études de cas sont données de façon à illustrer l’application de la methodologie proposée. Le GT donne un aperçu de la technologie actuelle, des domaines d’application et des valeurs économiques. Avec les développements en cours on peut s’attendre à ce que le VSC CCHT devienne encore plus attractif pour le transport de fortes puissances et puisse devenir une technologie alternative aux autres technologies viable. SUMMARY - TB 493 - JWG D1/B1.20 Non destructive water-tree detection in XLPE cable insulation Water treeing is one of the major causes of premature failures in cross-linked polyethylene (XLPE) cables operating in a wet environment and widespread replacement of failed cables has been very costly to many utilities. There are several techniques presently available to detect water treeing in cables that could help prioritize their cable replacement programme. The TB provides information to select the best water tree detection method and improve the interpretation of the test results to get an accurate assessment of the condition of cable systems. RESUME - BT N° 493 - GTC D1/B1.20 Détection non destructive des arborescences d’eau dans les isolants PR des câbles Les arborescences d’eau sont une des causes majeures des défauts prématurés dans les câbles isolés au polyéthylène réticulé (PR) opérant en ambiance humide. Pour de nombreuses compagnies le remplacement à grande échelle de câbles défaillants a été très coûteux. Il existe aujourd’hui plusieurs techniques disponibles pour détecter les arborescences d’eau dans les câbles, qui pourraient permettre de prioriser le programme de remplacement des câbles. La BT donne des informations permettant de sélectionner la meilleure méthode de détection et d’améliorer l’interprétation des résultats des essais pour obtenir une évaluation précise de l’état des systèmes de câbles. SUMMARY – TB 494 - WG D1.03 Furanic Compounds for Diagnosis The analysis of furanic compounds in the insulating oil of power transformers is used to characterize the thermal degradation of the solid paper insulation in transformers. In this Brochure, different aspects (analysis, factors of influence, diagnosis methods, statistical approach and user’s experiences) have been considered to make the interpretation easier. The formation, detection and behavior of these components in a transformer are described. A survey was conducted to present how these compounds are currently being used by utilities. Finally, No. 261 - April 2012 ELECTRA 1 real cases are given which demonstrate the usefulness and limitation of the technique. RESUME – BT N° 494 - GT D1.03 Diagnostics basés sur les Composés Furanniques On se sert du dosage des composés furanniques dans l’huile d’isolement des transformateurs de puissance pour caractériser la dégradation thermique des isolants papiers dans les transformateurs. Dans cette Brochure, on s’est intéressé à différents aspects (analyse, facteurs d’influence, méthodes de diagnostic, approche statistique et expériences des utilisateurs) en vue de rendre l’interprétation plus facile. On décrit la formation, la détection et le comportement de ces composés dans un transformateur. On a effectué une enquête afin de présenter la manière dont les sociétés d’électricité utilisent actuellement ces composés. Enfin, on indique quelques cas réels qui prouvent l’utilité et les limites de cette technique. SUMMARY – TB N° 495 - WG D2.29 Communications Access to Electrical Energy Consumers and Producers Today, the examination of communications access to consumers and producers has to be carried out in the context of the vision for smartgrid. In developing this technical brochure, the WG has defined the smartgrid and developed a view of the evolutionary process which could lead to implementation. Communication technologies have been considered as part of the development, indeed they are considered to be the key enabler for smart energy networks. RESUME – BT N° 495 - GT D2.29 Accès par Télécommunications aux Consommateurs et aux Producteurs d’Energie Electrique De nos jours, l’examen de l’accès par télécommunications aux consommateurs et aux producteurs doit se faire dans le contexte de la perspective des réseaux intelligents (smartgrids). En préparant cette brochure technique, le GT a donné une définition d’un réseau intelligent et a établi une présentation du processus d’évolution qui pourrait conduire à leur réalisation. Les technologies de télécommunications ont été considérées comme une partie de ce développement et elles sont en fait considérées comme un point clé pour rendre possible des réseaux électriques intelligents. ABSTRACT – TB N°. 496 – WG B1.32 Recommendations for Testing DC Extruded Cable Systems for Power Transmission at a Rated Voltage up to 500 kV In 2003, TB 219 was issued to give recommendations for testing HVDC extruded cables up to 250 kV. The trend for higher voltage levels in DC extruded cables systems resulted in a need for new test recommendations covering the highest voltage levels. Based on same principles as TB 219, this new Technical Brochure provides recommendations for the following tests on extruded cables for DC power transmission systems up to 500 kV : development test, prequalification test, type test, routine test, sample test and after installation test. 2 No. 261 - April 2012 ELECTRA RESUME – BT N°. 496 – GT B1.32 Recommandations Concernant les Essais des Câbles Extrudés de Transport d’énergie à Courant Continu pour des Tensions Assignées Jusqu’a 500 kV Publiée en 2003, la BT 219 donne des recommandations concernant les essais de câbles HTCC à isolation synthétique extrudée jusqu’à 250 kV. L’évolution vers des câbles extrudés à Courant Continu de niveaux de tensions supérieurs a fait apparaître la nécessité d’établir des recommandations qui couvrent les tensions assignées les plus élevées. Sur les mêmes principes de base que la BT 219, cette nouvelle Brochure Technique couvre désormais les niveaux de tension pour câbles extrudés jusqu’à 500 kV pour lesquels elle établit les recommandations en matière d’essais de préqualification, d’essais de type, de routine et sur prélèvements, et d’essais après pose. ANNONCES - ADVERTISING Page Advert Annonce 2ème de couverture 2nd Cover SERGI p15 Bentley p23 Albatros p31 DOW p35 ACDC p37 Ergon p44 Eureletric p45 Meetings of interest p87 Amec p96 Advertisement of Electra 3ème de couverture 3rd Cover CIGRE Session 44 4ème de couverture 4th Cover Siemens