ENGLISH A Register Sensor Device RS25 Quickstart www.mysick.com/en/RS2 Initial setup of IP-address (Node ID) The IP-address of the sensor is set by the following workflow 1-7 below, thereafter the communication with the PLC can start. 19,15 -------------------------------------------------------- 8015779.YLM9 0815 COMAT ------------------------------------------------------- 4 [mm] 37 RS25 Intended Use The register sensor RS25 is an optoelectronic sensor intended for noncontact recognition of print marks in the print industry. The warranty is no longer valid if the fiber optical cable is separated from the sensor housing (broken seal) or if the sensor housing has been opened (broken seal). The product version RS25-WL334000 may be used in gas explosive areas (e. g. using solvent ink) but not the RS25-WF334000 version. RS25-WL334000: Optical head: II 2G Ex op is IIB T4 Gb, Sensor housing: II (2) G [Ex op is Gb] IIB 14 Err 74 1 126 Menu 152 2 200 3 188 Please find detailed addresses and additional representatives and agencies in all major industrial nations at www.sick.com 000 d Node ID++ Node ID - - 5 = save % Diagnosis all on 88 Light Toggle R/G/B/all on ø 5,5 (4x) Toggle R/G/B/all on 6. Reboot (power ON/OFF > 5 seconds) 7. Ready for PLC communication 1 8 8 The optical register mark sensor system contains a separate analysis unit in a robust metal housing and an optical sensor head attached via fibre optics to the analysis unit. The triangular marks are used for side- and length register control in a printing machine. The detection of the front edge is used to calculate a shift in the longitudinal alignment and the left to right changing diameter of the detected mark is used to control the side register. 7,9 5 6,5 Mounting NodeID 15 Commissioning 4 surface anodized free 100 RS25 register sensor devices are no safety components pursuant to the EC machinery directive (2006 / 42 / EG). No modifications and conversions must be performed. All uses not described as intended use are forbidden. The company SICK takes no responsibility for the damages that may be caused by installing RS25-WF334000 in environments where it’s not intended to be used. The register sensor version RS25-WF334000 must not be used in potentially explosive areas. Netherlands Phone +31 (0)30 229 25 44 New Zealand Phone +64 9 415 0459 Norway Phone +47 67 81 50 00 Poland Phone +48 22 837 40 50 Romania Phone +40 356 171 120 Russia Phone +7-495-775-05-30 Singapore Phone +65 6744 3732 Slovakia Phone +421 482 901201 Slovenia Phone +386 (0)1-47 69 990 South Africa Phone +27 11 472 3733 South Korea Phone +82 2 786 6321 Spain Phone +34 93 480 31 00 Sweden Phone +46 10 110 10 00 Switzerland Phone +41 41 619 29 39 Taiwan Phone +886 2 2375-6288 Thailand Phone +66 2645 0009 Turkey Phone +90 (216) 528 50 00 United Arab Emirates Phone +971 (0) 4 88 65 878 USA/México Phone +1(952) 941-6780 Vietnam Phone +84 8 62920204 BZ int44 Australia Phone +61 3 9457 0600 Austria Phone +43 (0)22 36 62 28 8-0 Belgium/Luxembourg Phone +32 (0)2 466 55 66 Brazil Phone +55 11 3215-4900 Canada Phone +1 905 771 14 44 Czech Republic Phone +420 2 57 91 18 50 Chile Phone +56 2 2274 7430 China Phone +86 4000 121 000 +852-2153 6300 Denmark Phone +45 45 82 64 00 Finland Phone +358-9-2515 800 France Phone +33 1 64 62 35 00 Germany Phone +49 211 5301-301 Great Britain Phone +44 (0)1727 831121 Hong Kong Phone +852 2153 6300 Hungary Phone +36 1 371 2680 India Phone +91–22–4033 8333 Israel Phone +972-4-6881000 Italy Phone +39 02 27 43 41 Japan Phone +81 (0)3 5309 2112 Malaysia Phone +603 808070425 Non-intended Use –Mount the sensor via the fixing holes. –Wire the silver hole at the upper right corner to ground. See also illustration A. –The operating distance for the optical sensor head is 10 mm. – For normal paper background (somewhat matt), please mount the fiber optical head perpendicular to the background surface, see illustration (I). –For highly shiny backgrounds, please consider to mount the fiber optical head at a tilted angle (5 – 15°) according to the illustrations (II-IV). 47 Safety notes >> Read the Quickstart before performing any work with the register sensor device. >> Connection, assembly and settings must only be performed by specialist staff. >> Wiring work must only be performed when powered down. >> Only connect and separate line connections when powered down. >> Only use shielded lines for data transfer. For suitable accessories, see the operating instructions (Nr. 8015888). C Very light blue colored paper/foil background SICK AG, Erwin-Sick-Strasse 1, D-79183 Waldkirch XDD-File pink black bright yellow bright blue Orange/red 3,2 3 ver Receiver cei 30° R G Re Transmitter Transm. 30 SICK sensors are maintenance-free. We recommend – cleaning the optical surfaces (lenses and reflectors) and – checking the screw and plug connections at regular intervals. blue 3 27 Maintenance More representatives and agencies at www.sick.com ∙ Subject to change without notice ∙ The specified product features and technical data do not represent any guarantee. Weitere Niederlassungen finden Sie unter www.sick.com ∙ Irrtümer und Ä nderungen vorbehalten ∙ Angegebene Produkteigenschaften und technische Daten stellen keine Garantieerklärung dar. Plus de représentations et d’agences à l’adresse www.sick.com ∙ Sujet à modification sans préavis ∙ Les caractéristiques de produit et techniques indiquées ne constituent pas de déclaration de garantie. Para mais representantes e agências, consulte www.sick.com ∙ Alterações poderão ser feitas sem prévio aviso ∙ As características do produto e os dados técnicos apresentados não constituem declaração de garantia. Altri rappresentanti ed agenzie si trovano su www.sick.com ∙ Contenuti soggetti a modifiche senza preavviso ∙ Le caratteristiche del prodotto e i dati tecnici non rappresentano una dichiarazione di garanzia. Más representantes y agencias en www.sick.com ∙ Sujeto a cambio sin previo aviso ∙ Las características y los datos técnicos especificados no constituyen ninguna declaración de garantía. 欲了解更多代表机构和代理商信息,请登录 www.sick.com ∙ 如有更改 , 不另行通知 ∙ 对所给出的产品特性和技术参数 的正确性不予保证。 その他の営業所は www.sick.com よりご覧ください ∙ 予告なし に変更されることがあります ∙ 記載されている製品機能およ び技術データは保証を明示するものではありません。 B TW 10 XDD (XML Device Description) is a standardized file-format to describe the configuration of POWERLINK devices for easy usage in any POWERLINK master environment. The XDD file is adapted to the directive specified by the EPSG - Ethernet POWERLINK Standardization Group (www.ethernet-powerlink.org), download at www.sick.com. 37 analogue 40 digital output Bad side register Bad length register The fiber optical cable is 3.2 m long, minimum bend radius is 40 mm. NFPA79 applications only. Adapters providing field wiring leads are available. Refer to the product information. Enclosure Type 1. DEUTSCH Register Sensor Device RS25 Quickstart www.mysick.com/de/RS25 " 5-15° 0° B (I) (II) Sicherheitshinweise >> Lesen Sie die Quickstart-Anleitung, bevor Sie den Register-Sensor verwenden. >> Der Anschluss, die Montage und die Einstellungen dürfen nur von Fachpersonal vorgenommen werden. >> Die Verdrahtung darf nur bei ausgeschaltetem Strom durchgeführt werden. >> Anschlüsse nur bei ausgeschaltetem Strom verbinden und trennen. >> Für die Datenübertragung nur abgeschirmte Kabel verwenden. Für die passenden Zubehörteile, siehe Betriebsanleitung (Nr. 8015888). Verwendungszweck Der Register-Sensor RS25 ist ein optoelektronischer Sensor, der für die kontaktfreie Erkennung von Druckmarken im Druckwesen bestimmt ist. Die Garantie erlischt, wenn das Glasfaserkabel vom Sensorgehäuse getrennt wird (zerstörtes Siegel) oder wenn das Sensorgehäuse geöffnet wird (zerstörtes Siegel). Die Produktversion RS25-WL334000 kann an Orten verwendet werden, an denen die Gefahr von Gasexplosionen besteht (z. B. Lösungsmitteltinte), nicht jedoch die Version RS25-WF334000. RS25-WL334000: Optischer Sensorkopf: II 2G Ex op is IIB T4 Gb, Sensor Gehäuse: II (2) G [Ex op is Gb] IIB Nicht bestimmt für folgende Zwecke Die RS25-Register-Sensoren sind keine Sicherheitsbauteile im Sinne der EG-Maschinenrichtlinie (2006 / 42 / EG). Es dürfen keine Veränderungen oder Umwandlungen vorgenommen werden. Das Gerät darf nur für den Zweck verwendet werden zu dem es bestimmt ist. Das Unternehmen SICK übernimmt keine Haftung für Schäden, die durch die Installation des RS25-WF334000 in Umgebungen verursacht werden, für die das Gerät nicht bestimmt ist. Die Version RS25-WF334000 des Register-Sensors darf nicht an explosionsgefährdeten Orten verwendet werden. 5-10° Inbetriebnahme Connection diagramm Befestigung M12 Power supply – Befestigen Sie den Sensor durch Befestigungsbohrung. –S chließen Sie als Erdung das silberne Loch der rechten oberen Ecke an eine Erdung an. Siehe Abbildung A. –D er Tastabstand des Sensorkopfes beträgt 10 mm. –B ei normalem Papierhintergrund (matt) ist der Lichtleiterkopf senk-recht zur Hintergrundfläche anzubringen, siehe Darstellung (l). – F ür stark glänzende Hintergründe sollten Sie den Sensorkopf aus Glasfaser in einem schrägen Winkel (5 – 15°) befestigen gemäß Darstellung (II-IV). XDD-File XDD (XML Device Description) ist ein Standard-Dateiformat für die Konfiguration von POWERLINK-Geräten, um eine einfache Bedienung in POWERLINK-Master-Umgebungen zu gewährleisten. Die XDD-Datei entspricht der Richtlinie der EPSG - Ethernet POWERLINK Standardization Group (www.ethernet-powerlink.org), Download unter www.sick.com Specular=15-20° Ethernet plug-in 4 3 2 WH 1 BN 3 BU Contact Mark 1 1 2 5 GY 4 BK L+ Wire color Description Brown Voltage: 24 V +/– 20% Max current: 250 mA ø 20 Contact Mark Wire color 2 Not connected White – 1 RX+ Gray Wartung 3 M Blue Ground 2 TX+ White Die Sensoren von SICK sind wartungsfrei. Wir empfehlen: – d ie Reinigung der optischen Oberflächen (Linsen und Reflektoren) und – eine regelmäßige Überprüfung der Schraub- und Steckverbindungen. 4 Not connected Black – 3 RX- Red 5 Not connected Grey – 4 Tx- Blue (III) (IV) RS25-WL334000 / RS25-WF334000 Dimension Light spot size Sensing distance Sensing distance tolerance Light source Maximum No. of marks in register Start code configurable Data Interface Shape of head Front window Ambient temperature Abmessungen Lichtfleckgröße Tastabstand Tastabstand – Toleranz Lichtquelle Maximale Anzahl von Markierungen im Register Parametrierbarer Startcode Datenschnittstelle Form des Sensorkopfes Frontscheibe Umgebungstemperatur Length of fiber optical cable Diameter of fiber optical cable Bending radius (static) Bending radius (dynamic) Weight Output power on optic head ATEX Housing material Supply voltage VS 6) Power consumption 7) Precision 8) Input, teach-in (ET) Connection type Connector Protection class Circuit protection 9) Enclosure rating Länge des Glasfaserkabels Durchmesser des Glasfaserkabels Biegeradius (statisch) Biegeradius (dynamisch) Gewicht Ausgangsleistung am Optikkopf ATEX Gehäusematerial Versorgungsspannung UV 6) Leistungsaufnahme7) Präzision 8) Input, teach-in (ET) Anschlussart der Anschlusstechnik Schutzklasse Schutzschaltungen 9) Schutzart 1) 2) 3) 4) 5) 6) 1) 2) 3) 4) 5) 6) 7) 8) 9) *) Quadratic Glass Fiber optical cable included Aluminium Aluminium alloy, sandblasted Limit values: Operation in short-circuit protected network max. 8 A; Ripple max. 5 VSS Without load Signal transit time with resistive load VS connections reverse-polarity protected interference suppression Outouts overcurrent and short-circuit protected only RS25-WL334000 7) 8) 9) *) Quadratisch Glas Glasfaserkabel inbegriffen Aluminium Aluminiumlegierung, sandgestrahlt Grenzwerte: Betrieb im kurzschlussgeschützen Netz max. 8 A; Restwelligkeit max. 5 VSS Ohne Last Signalübertragungszeit bei Wirklast VS-Anschlüsse verpolsicher Entstörung Ausgänge überstrom- und kurzschlussfest nur RS25-WL334000 Sensor Sensorhead 200 x 100 x 47 mm 40 mm x 30 mm x 15 mm 1.1 mm x 2.0 mm 10 mm +/– 1 mm LED red, green, blue 20 Yes Ethernet POWERLINK 1) 2) Operation / Betrieb: –10 … +55 °C *) Storage / Lager: –20 … +70 °C 3200 mm 8 mm 40 mm 80 mm 1000 g 450 g 3) < 35 mW Ex II (2)G [Ex op is Gb] IIB * ) Ex II 2G Ex op is IIB T4 Gb * ) 4) 24 V +/- 20% < 250mA ≤ 40 µm Ethernet Powerlink M12, 8-pin IP 65 5)