safety data sheet dioleyl succinate
Transcription
safety data sheet dioleyl succinate
SAFETY DATA SHEET DIOLEYL SUCCINATE SDS DS ester Version NA 1.0 Creation date 12/09/2012 Page 1/5 1. IDENTIFICATION 1.1 Product identification Product Name Chemical name Dioleyl succinate Dioleyl succinate 1.2 Recommended Use and/or Restrictions on Use For Research & Development purposes only 1.3 Details of the supplier and manufacturer Name BIOAMBER S.A.S Address 3850 Annapolis Lane North Plymouth, MN 55447, USA Contact email [email protected] 1.4 Emergency phone number For Hazardous Materials Incidents Spill, Leak, Fire, Exposure, or Accident Call CHEMTREC Day or Night Within USA and Canada: 1-800-424-9300 Outside USA and Canada: +1 703-527-3887 (collect calls accepted) 2. HAZARD IDENTIFICATION 2.1 Hazard Classification: Not classified. 2.2 Acute Health Effects: No specific information is available in our data base regarding the toxic effects of this material for humans. However, exposure to any chemical should be kept to a minimum. Skin and eye contact may result in irritation. May be harmful if inhaled or ingested. Always follow safe industrial hygiene practices and wear proper protective equipment when handling this compound. 2.3 Chronic Health Effects: CARCINOGENIC EFFECTS : Not available. MUTAGENIC EFFECTS : Not available. TERATOGENIC EFFECTS : Not available. DEVELOPMENTAL TOXICITY: Not available. There is no known effect from chronic exposure to this product. Repeated or prolonged exposure to this compound is not known to aggravate existing medical conditions. 3. COMPOSITION/INFORMATION ON INGREDIENTS Chemical Name Dioleyl succinate Common name/Synonyms Diester of C18 unsaturated alcohol Diester of 9-octadecenol and succinic acid CAS number unlisted EC number unlisted [%] 98-100 The specific chemical identity and exact percentage (concentration) of composition has been withheld as a trade secret. Date of creation: 12/09/2012 BioAmber Copyright© 2012 All Rights Reserved SAFETY DATA SHEET DIOLEYL SUCCINATE SDS DS ester Version NA 1.0 Creation date 12/09/2012 Page 2/5 4. FIRST AID MEASURES 4.1 Eye contact 4.2 Skin Contact 4.3 Inhalation 4.4 Ingestion Check for and remove any contact lenses. IMMEDIATELY flush eyes with running water for at least 15 minutes. Keeping eyelids open. COLD water may be used. DO NOT use an eye ointment. Flush eyes with running water for a minimum of 15 minutes, occasionally lifting the upper eyelids. Seek medical attention. Treat symptomatically and supportively. After contact with skin, wash immediately with plenty of water. Gently and thorough wash the contaminated skin with running water and non-abrasive soap. Be particularly careful to clean folds, crevices, creases and groin. COLD water may be used. Cover the irritated skin with an emollient. Seek medical attention. Treat symptomatically and supportively. Wash any contaminated clothing before reusing. If the victim is not breathing, perform artificial respiration. Loosen tight clothing such as a collar, tie, belt or waistband. If breathing is difficult, oxygen can be administered. Seek medical attention. Treat symptomatically and supportively. INDUCE VOMITING by sticking finger in throat. Lower the head so that the vomit will not re-enter the mouth and throat. Loosen tight clothing such as a collar, tie, belt, or waistband. If the victim is not breathing, administer artificial respiration. Examine the lips and mouth to ascertain whether the tissues are damaged, a possible indication that the toxic material was ingested; the absence of such signs, however, is not conclusive. Seek immediate medical attention and, if possible, show the chemical label. Treat symptomatically and supportively. 5. FIREFIGHTING MEASURES Flammability: Flash Point Suitable extinguishing media: Hazardous combustion products Fire Hazards Explosion hazards Maybe combustible at high temperatures No data available SMALL FIRE: Use DRY chemicals, CO2, water spray or foam. LARGE FIRE: Use water spray, fog or foam. DO NOT use water jet.. These products are toxic carbon oxides (CO, CO2) No data available Sensitivity to mechanical impact: no data available Sensitivity to static discharge : no data available No additional information is available regarding the risks of explosion. 6. ACCIDENTAL RELEASE MEASURES Spill Cleanup Instructions In case of a spill and/or a leak, always shut off any sources of ignition, ventilate the area, and exercise caution. Absorb with an inert material and put the spilled material in an appropriate waste disposal. Finish cleaning the spill by rinsing any contaminated surfaces with copious amounts of water. Consult federal, state, and/or local authorities for assistance on disposal. no data available 7. HANDLING AND STORAGE Handling and Storage Information Date of creation: 12/09/2012 Keep away from heat and sources of ignition. Mechanical exhaust required. When not in use, tightly seal the container and store in a dry, cool place. Avoid excessive heat and light. Do not breathe gas, fumes, vapor or spray. Always store away from incompatible compounds such as oxidizing agents. BioAmber Copyright© 2012 All Rights Reserved SAFETY DATA SHEET DIOLEYL SUCCINATE SDS DS ester Version NA 1.0 Creation date 12/09/2012 Page 3/5 8. EXPOSURE CONTROLS/PERSONAL PROTECTION 8.1. Control parameters Exposure limits OSHA: Not established ACGIH: Not established 8.2. Personal protection Appropriate engineering measures Provide exhaust ventilation or other engineering controls to keep the airborne concentrations of vapors below their respective threshold limit value. Ensure that eyewash station and safety shower is proximal to the work-station location. Personal protection equipment Splash goggles. Lab coat. Vapor respirator. Boots. Gloves. Suggested protective clothing might not be sufficient; consult a specialist BEFORE handling this product. 9. PHYSICAL AND CHEMICAL PROPERTIES 9.1. Information about the essential physical and chemical properties Physical state Colour Odour pH Melting point/freezing point Boiling point Flash point Vapour pressure Relative density Solubility in water Partition coefficient: n-octanol/water Solid White Not available Not available Not available Not available Not available Not available Not available Not available Not available 10. STABILITY AND REACTIVITY Chemical stability Stable under the recommended storage conditions. Conditions of instability Avoid excessive heat and light. Incompatible materials No data available 11. TOXICOLOGICAL INFORMATION 11.1. Information about toxicological effects Routes of Entry Inhalation, ingestion, and dermal and eye contact Acute toxicity Oral LD50: no data available Inhalation LC50: no data available Dermal LD50: no data available Intravenous (mouse) LD50 : no data available Date of creation: 12/09/2012 BioAmber Copyright© 2012 All Rights Reserved SAFETY DATA SHEET DIOLEYL SUCCINATE Skin corrosion/skin irritation No data available Severe eye injuries/eye irritation No data available Respiratory or cutaneous sensitisation No data available Stem cell mutagenicity No data available Carcinogenicity Reproductive toxicity IARC: no data available ACGIH: no data available No data available. Teratogenicity/Embryotoxicity No data available. Specific toxicity for various target organs - single exposure (GHS) No data available Specific toxicity for various target organs - repeated exposure (GHS) No data available Hazards due to aspiration No data available Toxicologically Synergistic Materials No data available SDS DS ester Version NA 1.0 Creation date 12/09/2012 Page 4/5 There is no known effect from chronic exposure to this product. Repeated or prolonged exposure to this compound is not known to aggravate existing medical conditions. 12. ECOLOGICAL INFORMATION Ecotoxicity No data available Environmental Fate No data available 13. DISPOSAL CONSIDERATIONS Waste handling methods Respect the regulations in force. Offer surplus and non-recyclable solutions to a licensed disposal company. Contact an accredited service professional for disposal of this product. Contaminated packaging: dispose of with unused product 14. INFORMATION FOR TRANSPORT DOT Classification Not a DOT controlled material (US) PIN Number Not applicable Proper shipping name Not applicable Packing group Not applicable 15. REGULATORY INFORMATION TSCA Chemical Inventory (EPA) Not listed. For Research & Development purposes only. WHMIS Classification: Not available Date of creation: 12/09/2012 BioAmber Copyright© 2012 All Rights Reserved SAFETY DATA SHEET DIOLEYL SUCCINATE SDS DS ester Version NA 1.0 Creation date 12/09/2012 Page 5/5 16. OTHER INFORMATION BIOAMBER laboratory chemicals are for research purposes only and are NOT intended for use as drugs, food additives, households, or pesticides. The information herein is believed to be correct, but does not claim to be all inclusive and should be used only as a guide. Neither the above named supplier nor any of its subsidiaries assumes any liability whatsoever for the accuracy or completeness of the information contained herein. Final determination of suitability of any material is the sole responsibility of the user. All chemical reagents must be handled with the recognition that their chemical, physiological, toxicological, and hazardous properties have not been fully investigated or determined. All chemical reagents should be handled only by individuals who are familiar with their potential hazards and who have been fully trained in proper safety, laboratory, and chemical handling procedures. Although certain hazards are described herein, we cannot guarantee that these are the only hazards which exist. Our SDS sheets are based only on data available at the time of shipping and are subject to change without notice as new information is obtained. Avoid long storage periods since the product is subject to degradation with age and may become more dangerous or hazardous. It is the responsibility of the user to request updated SDS sheets for products that are stored for extended periods. Disposal of unused product must be undertaken by qualified personnel who are knowledgeable in all applicable regulations and follow all pertinent safety precautions including the use of appropriate protective equipment (e.g. protective goggles, protective clothing, breathing equipment, facial mask, fume hood). For proper handling and disposal, always comply with federal, state, and local regulations. Date of creation: 12/09/2012 BioAmber Copyright© 2012 All Rights Reserved