Place de la ventilation dans l`ACR Nouvelles perspectives
Transcription
Place de la ventilation dans l`ACR Nouvelles perspectives
Place de la ventilation dans l’ACR Nouvelles perspectives Résultat d'une étude comparative entre l'utilisation du BAVU et d’un ventilateur à déclenchement manuel Docteur Marjanovic Nicolas Service d’Accueil des Urgences / SAMU 29 CHRU de la Cavale Blanche, Brest Pas de conflit d’intérêt DES RECOMMANDATIONS SUR LA VENTILATION PRIORITE AU MASSAGE GÉNÉRALITÉS SUR LA VENTILATION AU BAVU • Quand intervient la ventilation au BAVU ? – Avant l’intubation : • Par les paramédicaux • Ventilation au masque – Après l’intubation • Pas de ventilateur sur place • Ventilateur en panne DE LA QUALITÉ DE LA VENTILATION The Performances of Standard and ResMed Masks During Bag-Valve-Mask Ventilation Vol. 17, No. 2 , Pages 235-240 Hyoung Youn Lee, Kyung Woon Jeung, Byung Kook Lee, Seung Joon Lee, Yong Hun Jung, Geo Sung Lee, Yong Il Min, Tag Heo JAMA (2005) 293, 305-10 Gastric inflation would be expected to rise proportionally, with the increase of peak airway pressure and peak flow. RÉSULTATS DE L’ÉTUDE BRESTOISE EasyCPR • Dispositif de ventilation à déclenchement manuel • Réglage couple Vt/FR • Alarme de pression • Gâchette de déclenchement au niveau du masque • Utilisation de la gâchette limitée par la fréquence réglée • Poumon test ASL5000 (IngMar Med©) • 3 séquences (normal, restrictive, obstructive) • 5 groupes professionnels (n=10/groupe) • Analyse : – Performance (Vt, Ppeak; Fréquence, Volume Résiduel, Volume Total) – Ergonomie Volume insufflé 800 700 Vt Moyen (mL) 600 500 BAV 400 CPR 300 200 100 0 EMD EMR AP EDN PM TOUS Volume insufflé BAV EMD Vt Moyen(±SD) % dans l'intervalle 400-600mL EMR Vt Moyen(±SD) % dans l'intervalle 400-600mL AP Vt Moyen(±SD) % dans l'intervalle 400-600mL EDN Vt Moyen(±SD) % dans l'intervalle 400-600mL PM Vt Moyen(±SD) % dans l'intervalle 400-600mL Tous Moyenne Total % dans l'intervalle 400-600mL * test non paramétrique § Chi² 450±170mL 45,8% 347±164mL 21,7% 474±227,5mL 42,0% 305±170mL 27,1% 440±243mL 18,5% 405±194mL 31,6% CPR 399±150mL 42,6% 336±113mL 34,0% 398±150mL p <0,001* 0,36§ 0,422* <0,001§ <0,001* 61,7% <0,001§ 444±87mL <0,001* 80,3% <0,001§ 402±156mL 68,0% 392±141mL 56,7% 0,009* <0,001§ 0,482* <0,001 Séquence Obstructive 56,7% CPR 42,7% Répartition des observations (%) 0,6% ² 31,6% BAV 51% 17,4% Volume courant (mL) p<0.001 22,4% CPR ² 20,5% p<0.21 BAV Ensemble des séquences (Normal, restrictive, Obstructive) BAV CPR Volume insufflé Results The mean inspiratory Vt was measured below 500 ml with both devices and for all pathological conditions. […] Distribution was significantly different for both devices. Discussion This experimental bench-test study describes improved compliance with guidelines when an automatic, manually-triggered ventilation device is used ([…] more regular Vt values, less overdistension), when compared to a BVM. Several studies have shown that resuscitation using both hands may be more efficient than that using one hand, in terms of Vt delivery (higher mean value and lower variation). Our results show that the EasyCPR is more efficient in terms of Vt delivery, since with this device all professionals used both hands to keep the mask in place and control leaks. Volume insufflé Volume insufflé D’après CD. Deakin et al. Resuscitation 81 (2010) – adult Advanced life support. Fréquence de ventilation BAV p < 0.001 CPR Fréquence de ventilation Results The ventilation rate fell consistent with the guidelines while using the EasyCPR, between 9 and 11 breaths/min for 93% of the recording, but not with BVM. (10±2 versus 18±6; p<0.001) Discussion […] as a result of its controlled ventilation rate. This outcome may be of importance since hyperinflation is a known prolem in CPR because it increases intrathoracic pressure which reduces the haemodynamic effectiveness of chest compression [and] hyperventilation decreased coronary perfusion pressures […] thus resulting of lower survival rates. O'Neill JF, Deakin CD. Resuscitation 2007;73 Aufderheide TP, Lurie KG. Crit Care Med 2004;32 Aufderheide TP et al. Circulation 2004;109 Pression Inspiratoire de Pointe Distension Pulmonaire Volume résiduel A volume insufflé équivalent, la PIP est plus faible avec EasyCPR, en rapport avec un Ti plus long qu’avec BAVU Pression Inspiratoire de Pointe Distension Pulmonaire Volume résiduel Volume résiduel p<0.001 Normal BAV 266±268mL CPR 82±69mL Obstructive BAV Restrictive p<0.001 198±204mL CPR 76±73mL BAV 9±26mL CPR 8±31mL p<0,001 p<0,001 NS Volume pulmonaire total 570±358mL 394±164mL 602±333mL 467±177mL 302±180mL 283±107mL p<0,001 p<0,001 NS Ergonomie EVALUATION ERGONOMIQUE COMMENTAIRES LIBRES BAVU - Contrôle de la ventilation - Fatiguant EasyCPR - Simple - Contrôle des fuites Biais & Limites • Etude sur mannequin • Pas d’évaluation de l’insufflation gastrique • La compliance pulmonaire baisse au cours de l’ACR (Melker RJ & Banner MJ; Ann Emerg Med 1985) • L’ESOP chute au cours de tous les ACR après quelques minutes (Deakin CD et al. Resuscitation 2010) Conclusion • Pas de différence de Vt moyen – Distribution plus régulière avec EasyCPR • Meilleur contrôle des fuites – Maintien du masque à 2 mains à la bouche du patient • Surdistension moindre • Pression inspiratoire plus faible • Evaluation subjective des deux dispositifs différentes