Canada - T3P Construction

Transcription

Canada - T3P Construction
NOTE POUR LA PLOMBERIE
Gouvernement Government
du Canada
of Canada
TUYAUTERIE VERS LE BAS
TUYAUTERIE VERS LE HAUT
TUYAUTERIE EXISTANTE SOUS-DALLE
NOUVELLE TUYAUTERIE DE DRAINAGE
This drawing is an instrument of service and is protected by copyright, copyright for the consultant's
instrument of service belongs to the consultant. Copies including electronic copies, may only be used
for the purpose intended and for a one-time use, on the same site, and for the same project and may
not be offered for sale or transfer without the express written consent of the consultant.
NOUVELLE TUYAUTERIE DE DRAINAGE SOUS-DALLE
VANNE VERTICAL
TUYAUTERIE D'EAU FROIDE DOMESTIQUE EXISTANTE
ROBINET D'ARROSAGE
NOUVELLE TUYAUTERIE D'EAU FROIDE DOMESTIQUE
TUYAUTERIE D'EAU CHAUDE DOMESTIQUE EXISTANTE
S
NOUVELLE TUYAUTERIE D'EAU CHAUDE DOMESTIQUE
207
205
202
207A
3
1
2
1
2
3
EXISTING SINK TO BE RELOCATED, FAUCET TO BE DEMOLISHED.
EXISTING DISHWASHER TO BE RELOCATED C/W PIPING.
DRAINAGE PIPING TO BE REMOVED UP TO GROUND FLOOR CEILING.
208
4
208A
5
5
DOMESTIC COLD AND HOT WATER PIPING TO BE REMOVED UP TO GROUND FLOOR CEILING.
TOILET TO BE REMOVED AND KEPT FOR REINSTALLATION.
203
6
204
7
6
5
S
S
8
9
S
8
EXISTING BATHROOM SINK AND FAUCET TO BE RELOCATED.
DRAINAGE PIPING TO BE REMOVED UP TO FLOOR.
DOMESTIC COLD AND HOT WATER PIPING TO BE REMOVED UP TO FLOOR.
PLUMBING VENT COLUMN. VERTICAL SECTION BETWEEN FLOOR AND ROOF VENT TO BE DEMOLISHED.
S
7
9
10
10
10
TEMPERATURE SENSOR ON THE RADIATOR CABINET TO BE REMOVED AND KEPT FOR REINSTALLATION.
1
401B
PLUMBING - EXISTING / DEMOLITION
1:50
SCALE: 1:50
NOTES, NOUVEAU:
1
RELOCATED EXISTING SINK. INSTALL NEW COLD AND HOT WATER PIPING, DRAIN AND VENT PIPING, P-TRAP, ISOLATION
VALVES, FLEXIBLE PIPING AND WATER HAMMER ARRESTER.
2
ROB-1
RELOCATED EXISTING DISHWASHER AND PIPING.
3
DRAINAGE PIPING TO BE CONNECTED TO THE EXISTING DRAINAGE PIPING IN THE GROUND FLOOR CEILING.
2
1
4
DOMESTIC COLD AND HOT WATER PIPING TO BE CONECTED TO THE EXISTING DOMESTIC COLD AND HOT WATER PIPING IN
THE GROUND FLOOR CEILING.
5
207
205
202
14
PIPING IN THE GROUND FLOOR CEILING.
1
2016/08/26
S.R.
6
207A
RELOCATED EXISTING BATHROOM SINK AND FAUCET. INSTALL NEW COLD AND HOT WATER PIPING, DRAIN AND VENT
PIPING, P-TRAP, ISOLATION VALVES, FLEXIBLE PIPING AND WATER HAMMER ARRESTER.
7
REINSTALL THE EXISTING TOILET C/W NEW WAX RING.
8
9
EXISTING RADIATOR BRACKETS TO BE MODIFIED. THE TOP SCREW NEEDS TO BE LOCALIZED BEHIND THE EXISTING
RADIATOR.
10
208
11
12
DARHC
7
208A
203
204
8
11
13
6
14
S
12
7
S
NOUVELLE TUYAUTERIE INSTALLER DANS LE NOUVEAU CABINET ARCHITECTURAL.
NEW PIPING IN THE NEW ARCHITECTURAL CABINET.
DRAINAGE PIPING TO BE CONNECTED TO THE EXISTING DRAINAGE PIPING AT FLOOR LEVEL.
D'EAU CHAUDE DOMESTIQUE EXISTANTE AU PLANCHER.
DOMESTIC COLD AND HOT WATER PIPING TO BE CONNECTED TO THE EXISTING DOMESTIC COLD AND HOT WATER PIPING
AT FLOOR LEVEL.
EXISTING SENSOR TO REINSTALL ON THE NEW ARCHITECTURAL CABINET.
NEW VENT PIPING IN THE CEILING.
15
14
14
S
S
15
13
13
DISPOSITIF ANTI-REFOULEMENT
S. RICHARD, ing.
NOMENCLATURE DE PLOMBERIE:
TYPE
MANUF.
DARHC
APOLLO
REMARQUES
S. RICHARD, ing.
ROB-1
9
2
401B
PLOMBERIE - NOUVEAU
PLUMBING - NEW
1:50
SCALE: 1:50
9
V. SAVARIA, tech.
7.6L/min. (2.0 usgpm),
FAUCET WITH LEVER STYLE HANDLE, 203mm ENTRAXE, AERATOR IS LIMITED TO 7.6L/min. (2.0 usgpm), "CHATEAU
SINGLE-HANDLE KITCHEN FAUCET" SERIE, MOEN MODEL 7430.
EQUIVALENT:
AMERICAN STANDARD, ZURN
HBDUC34
20mm
1, 2, 3, 4
EQUIVALENT:
WATTS, WILKINS
NO. OTP | WBS NO.
2. CORPS EN LAITON.
3. COMPOSANTES DU DISPOSITIF ANTI-REFOULEMENT EN ACIER INOXYDABLE.
NO. DESSIN | DWG. NO.
Canada
de .

Documents pareils