SEL-3421 Motor Relay HMI (With LCD Display) Quick
Transcription
SEL-3421 Motor Relay HMI (With LCD Display) Quick
SEL-3421 Motor Relay HMI (With LCD Display) Quick-Start Guide Overview The SEL-3421 Motor Relay HMI can: ➤ Read metering and monitoring data. ➤ Inspect targets. ➤ Control relay operations. ➤ Display diagnostics. ➤ Display, trigger, or clear events. The SEL-3421 has ten LEDs, eight of which are tricolor and programmable, with configurable labels. ENABLED and TRIP are the two fixed LEDs. This module has a graphical display with six pushbuttons for navigation, five soft keys for functions, and four pushbuttons for control. What’s in the Box? ➤ Gasket (1) ➤ Label Removal Tool ➤ Screws for Panel Mounting (4) ➤ Panel Cutout Sheet ➤ DIN Rail Clips (2) ➤ SEL-3421 Motor Relay HMI (With LCD Display) Quick-Start Guide Safety Information Dangers, Warnings, and Cautions See the product manual for additional safety information. This manual uses three kinds of hazard statements, defined as follows: DANGER Indicates an imminently hazardous situation that, if not avoided, will result in death or serious injury. Date Code 20160509 WARNING Indicates a potentially hazardous situation that, if not avoided, could result in death or serious injury. *PLS3421-01* CAUTION Indicates a potentially hazardous situation that, if not avoided, may result in minor or moderate injury or equipment damage. SEL-3421 Motor Relay HMI 2 Safety Symbols The following symbols are often marked on SEL products. CAUTION ATTENTION Refer to accompanying documents. Se reporter à la documentation. Earth (ground) Terre Protective earth (ground) Terre de protection Direct current Courant continu Alternating current Courant alternatif Both direct and alternating current Courant continu et alternatif Instruction manual Manuel d’instructions Safety Marks The following statements may apply to this device. General Safety Marks For use in Pollution Degree 2 environment. Pour l'utilisation dans un environnement de Degré de Pollution 2. Terminal Ratings Tightening Torque Compression Plug: 0.5–1.0 Nm (4.4–8.8 in-lb) Compression Plug Mounting Ear Screw: 0.18–0.25 Nm (1.6–2.2 in-lb) Spécifications des bornes Couple de serrage Fiche à compression : 0,5–1,0 Nm (4,4–8,8 livres-pouce) Vis à oreille de montage de la fiche à compression : 0,18–0,25 Nm (1,6–2,2 livres-pouce) Stripping Length: 8 mm Longueur de dénudement : 8 mm Holes in the enclosure for mounting and wiring the HMI shall not be greater than 775 mm2. Les trous dans boîtier pour le montage et le câblage de l’IHM ne doivent pas dépasser 775 mm2. SEL-3421 Motor Relay HMI Date Code 20160509 3 Installation Drawings Panel Mount DIN Rail Mount Date Code 20160509 SEL-3421 Motor Relay HMI 4 Connection Navigation ➤ The SEL-3421 connects to the HMI Ethernet port on the SEL-849 relay and receives power from the HMI port. Figure 1 shows the main menu screen. Using the Up Arrow or Down Arrow and ENT pushbuttons, you can navigate to specific menu items in the main menu. ➤ Connection to the relay requires an RJ45 Ethernet cable, such as the SEL-C627M, double-shielded, 600 V, MCC-rated, category 5e Ethernet cable, with a maximum length of 7.62 meters (25 feet). ➤ When the relay is turned on, the HMI displays with default settings, as shown in the product photo in Overview. Refer to Section 8: Human Machine Interface and Section 1: Introduction and Specifications, in the SEL-849 Instruction Manual for more details on the HMI operation and specifications. NOTE: Make sure the relay, HMI, and SELBOOT firmware revisions are compatible. Refer to Appendix A: Firmware and Manual Versions in the SEL-849 Instruction Manual. Accessories ➤ For customizing the LED labels on the SEL-3421 and SEL-3422 modules, order Configurable Label Kit, P/N 915900268. ➤ Order P/N 915900269 for replacement screws and DIN rail clips and supports for as many as five SEL-3421/SEL-3422 HMIs. ➤ The SEL-3421 does not ship standard with an SEL-C627M Ethernet cable. To purchase an SEL-C627M Ethernet cable, please visit https://selinc.com/products/category-5e-ethernet/. Using the Arrow Key Monitor Targets Control Status Meter Events Monitor Targets METER TRGTS STATUS CTRL Pressing Soft Key 5 (MORE) METER TRGTS STATUS CTRL MORE Monitor Targets Control Status METER TRGTS STATUS CTRL Figure 1 MORE MORE Main Menu Factory Assistance We appreciate your interest in SEL products and services. If you have questions or comments, please contact us at: Schweitzer Engineering Laboratories, Inc. 2350 NE Hopkins Court Pullman, WA 99163-5603 U.S.A. Telephone: +1.509.332.1890 Fax: +1.509.332.7990 Internet: selinc.com Email: [email protected] 2016 by Schweitzer Engineering Laboratories, Inc. All rights reserved. All trademarks are the property of their respective holders. SEL products appearing in this document may be covered by U.S. and Foreign patents. The information in this document is provided for informational use only and is subject to change without notice. Date Code 20160509