CONTINUING EDUCATION AND
TRAINING IN PHYSIOTHERAPY
1 day (7 hours)
Motor control and ankle joint protection
Update on scientific knowledge and practical consequences for
physiotherapists
Pascal TOSCHI, Physiotherapist
Romain TERRIER, PhD
CEVRES santé : systèmes pour l’évaluation et la réadaptation musculaire
CEVRES BP 322 SAVOIE TECHNOLAC 73 377 LE BOURGET DU LAC Cedex
Tel 04 79 25 25 47 Fax 04 79 65 76 08 Email : [email protected]
SA au capital de 120 882 € Siret 42250545300031 RC CHAMBERY 422505453
www . myolux .com
Motor control and ankle joint protection
Training session on the use of Myolux™ devices
Trainers
Pascal TOSCHI: physiotherapist
Romain TERRIER: PhD in motor control
The contents of the training session have been developed in collaboration with:
Brice PICOT: sport physiotherapist
Nicolas FORESTIER: research Professor in motor control (Université de Savoie, France).
Objectives
The objective of this training session is to present an update on the latest scientific knowledge in the
field of joint protection and ankle sprain rehabilitation. With this knowledge, the trainers will
present the requirements that are essential in the management of efficient ankle sprain
rehabilitation. The contents of the training will enable trainees to integrate this new knowledge into
their daily practice in very practical ways.
Training recognized by the physiotherapy profession
This course is already taught in the following Physiotherapy Schools and Continuing Education
structures:
-
ENKRE - Saint-Maurice, France
-
IFMK - Grenoble, France
-
CEERRF - Saint-Denis, France
-
HES-SO - Loeche-les-Bains, Switzerland
-
Sport physiotherapy training, SFMKS (French Society of Sport Masseurs-Physiotherapists)
-
Sports Physiotherapy training - Marseille, France
CEVRES santé : systèmes pour l’évaluation et la réadaptation musculaire
CEVRES BP 322 SAVOIE TECHNOLAC 73 377 LE BOURGET DU LAC Cedex
Tel 04 79 25 25 47 Fax 04 79 65 76 08 Email : [email protected]
SA au capital de 120 882 € Siret 42250545300031 RC CHAMBERY 422505453
www . myolux .com
Contents of the training session
The session is scheduled on one day (7 hours)
I. Ankle sprain
1.
Functional anatomy of the ankle
2.
Medico-economic challenges of ankle sprain
3.
History of rehabilitation management
II. Motor control and ankle joint protection
1.
Limits of the conventional management strategies
2.
Strengthening optimization of ankle eversor muscles
3.
Optimization of ankle proprioceptive training
4.
Integration of efficient neuromuscular re-programming: pro-activation
and unloading strategies
III. Practical tests of the Myolux™ devices
1.
Field testing of the Myolux™ Medik I, Medik II, and Soft devices.
2.
Objective measurements of proprioceptive quality and strength
production capacity of eversor muscles with a laboratory instrumented-tool
CEVRES santé : systèmes pour l’évaluation et la réadaptation musculaire
CEVRES BP 322 SAVOIE TECHNOLAC 73 377 LE BOURGET DU LAC Cedex
Tel 04 79 25 25 47 Fax 04 79 65 76 08 Email : [email protected]
SA au capital de 120 882 € Siret 42250545300031 RC CHAMBERY 422505453
www . myolux .com
Related publications
The contents of this training session are the results of a continual collaboration between
physiotherapists and researchers in motor control (Exercise Physiology Laboratory - Savoy, France)
and were the subject of numerous publications:
Forestier N, Toschi P. The effects of an ankle destabilization device on muscular activity while
walking (2005). International Journal of Sport Medicine, 6:464-470.
Forestier N, Terrier R. Peroneal reaction time measurement in unipodal stance for two
destabilization axes (2011). Clinical Biomechanics, 26: 766-771.
Terrier R, Forestier N, Bavazzano P, Toschi P. La cheville: de la prévention des entorses externes à
l’optimisation de la performance sportive (2011). Revue de l’Association des Entraineurs Français
d’Athlétisme, 202 : 32-36. (The ankle: from lateral ankle sprain prevention to sport performance
enhancement (2011).
Terrier R, Toschi P, Forestier N. Stratégies de protection de la cheville : des connaissances
scientifiques à la prise en charge kinésithérapique (2011). Kinésithérapie Scientifique, 527 : 5-10.
(Ankle protection strategies : from scientific knowledge to physiotherapy management. (2011).
Terrier R, Toschi P, Forestier N. Réathlétisation suite à une entorse externe de la cheville (2011).
Kinésithérapie du Sport Information, 8-10. (Re-athletization after ankle sprain (2011).
Picot B, Terrier R, Forestier N. Le contrôle moteur et la protection articulaire de la cheville. 1Concepts de base (2012). Kinésithérapie Scientifique, 530 : 57-58. (Motor control and ankle joint
protection. 1- General concepts (2012).
CEVRES santé : systèmes pour l’évaluation et la réadaptation musculaire
CEVRES BP 322 SAVOIE TECHNOLAC 73 377 LE BOURGET DU LAC Cedex
Tel 04 79 25 25 47 Fax 04 79 65 76 08 Email : [email protected]
SA au capital de 120 882 € Siret 42250545300031 RC CHAMBERY 422505453
www . myolux .com
Picot B, Terrier R, Toschi P, Forestier N. Des réactions posturales suite à une inversion soudaine de
cheville? (2012). Kinésithérapie Scientifique, 531 : 29-32 (Postural reactions following a sudden
ankle inversion? (2012).
Terrier R, Picot B, Forestier N. Le contrôle moteur et la protection articulaire de la cheville. 1Optimisation du renforcement des muscles fibulaires (2012). Kinésithérapie Scientifique, 532, sous
presse. (Motor control and ankle joint protection. 1- Strengthening optimization of the fibulars.
Forthcoming 2012
Terrier R, Toschi P, Forestier N. Prise en charge des entorses externes de cheville : étude clinique
préliminaire sur l’efficacité du dispositif Myolux™. Journal de Traumatologie du Sport, (2012).,
sous presse. (Management of lateral ankle sprains: a preliminary clinical study on the efficiency of
the Myolux device. Forthcoming 2012.)
CEVRES santé : systèmes pour l’évaluation et la réadaptation musculaire