SunStar25 Wall Sconce

Transcription

SunStar25 Wall Sconce
Wall sconce 25 - “WS25” - Low Voltage Surface Mounted Luminaire
Important Safety Instructions - Save These Instructions
Use only with Class 2 Power Unit
• These products are only suitable for connection to a Class 2 power
source and have not been evaluated for use when connected to a
power source that does not comply with Class 2 voltage and energy
limited supplies.
all installations of sunstar25 should be
performed by a certified electrician and be in
compliance with the national electricians code as
well as local codes.
Solid State LED
WS25
Interior / Exterior
Wall sconce
Suitable for Wet locations
CONSIGNES DE SÉCURITÉ IMPORTANTES - CONSERVEZ SOIGNEUSEMENT CES INSTRUCTIONS
A UTILISER UNIQUEMENT AVEC UNE SOURCE D’ALIMENTATION
DE CLASSE 2
• Ces produits doivent être branchés uniquement à une source d’alimentation de classe 2 et n’ont pas été testés pour une utilisation lors d’une
connexion à une source d’énergie non conforme à la tension de classe
2 et à l’approvisionnement en énergie limitées.
Ce produit doit Étre installÉ selon le code
d’installation pertinent, par une personne qui connaÍt
bien le produit et son fonctionnement ainsi que les
risques inhÉrents.
COMPATIBLE AVEC DES ENVIRONNEMENTS MOUILLES.
Model
Max Input Voltage (Vdc)
Max Current (mA)
Max Wattage
WS25
24
1400
15
Fixture Wiring:
E338721
R(+)
Driver
Contact:
R(+)
WS25
B(-)
B(-)
To Driver
Certification:
R(+)
R(+)
WS25
4811 Quail Crest Place
Lawrence, KS 66049
www.sunlitest.com
T:785.856.0219
UL and cUL
Wet Location Listed
IP66 Rated
B(-)
B(-)
Energy:
>0.9 Power Factor
700mA / ~ 20VDC
-30° C to 40°C
Suggested wiring utilizes bullet connections in alignment with the direction of current flow from the driver.
Fixture Installation Instructions:
Turn power off before any installation, inspection or removal of fixture/wiring.
single-gang box, #8-32 Hanger Bolts and Acorn Finishing Nuts are supplied by others.
single-gang box should be completely installed before attempting to install this fixture.
1
Once single-gang box is completely installed, outfit the
exposed wires with bullet connections.
•Red (+) with a female bullet connector.
•Black (-) with a male bullet connector.
2
Push wires back into wall and screw in acorn finishing
nuts over the hanger bolts to secure fixture on wall.
3
Outfit the fixture wires with bullet connections and then
connect bullet connections from fixture wires and driver
wires together.
Dimming Wiring:
Switch to Driver Diagrams:
B
A
E
C
D
A
C
F
H
E
F
B
G
D
H
G
Accessories: Recommended Switch is Leviton Slide Dimmer with Locator Light On/Off Preset Switch (IP710-DLZ)
A
B
C
D
Red Individually Capped 3-Way Switch when not used
Green Ground Wire
120 VAC Hot Black
Red to Black VAC Connection between Switch and Driver
E
F
G
H
0-10 VDC Grey and Purple Dimming Wires
Black and Red to Lamps
120 VAC Neutral Wire
Orange Individually Capped TS Wire
0-10V Dimmer Switch Installation Instructions:
1
2
For Dimming, a 0-10V Dimmer must be used.
Wire Switches are as shown in the image:
• Wires that are not being utilized must be capped
individually.
• If dimming function of LED drive is not being utilized, cap
grey and purple wires individually.
Driver Recommendations:
Non-Dimmable
Driver Suggestion
1 Module with 1 Chip
1 Module with 2 Chips
1 module with 3 or 6 Chips
3 to 8 in a series
2 to 4 in a series
1 or 2 in a series
LPLC-18-700
9 to 15 in a series
4 to 7 in a series
3 to 5 in a series
LPC-35-700
2 series of 10/11/12/13/14 fixtures in parallel
total fixtures: 20/22/24/26/28
2 series of 10/12/14 fixtures in parallel
total fixtures: 20/24/28
2 series of 3/4/5 fixtures in parallel
total fixtures: 6/8/10
PLN-60-48
6 to 8 in a series
3 or 4 in a series
2 in a series
RSLD035-7A
8 to 10 in a series
5 in a series
3 in a series
RSLD035-9A
10 to 13 in a series
5 or 6 in a series
4 in a series
RSLD035-12
14 to 18 in a series
7 to 9 in a series
5 or 6 in a series
RSLD035-16
2 series of 12/13/14 fixtures in parallel
total fixtures: 24/26/28
2 series of 6/7 fixtures in parallel
total fixtures: 12/14
2 series of 4/5 fixtures in parallel
total fixtures: 8/10
RSLD070-14
Dimmable
Number of Fixtures
Number of Chips
www.Sunlitest.com
Connect
4811 Quail Crest Place
Lawrence, KS 66049
T: 785.856.0219
08/19/14

Documents pareils