SunStar25 Wall Sconce
Transcription
SunStar25 Wall Sconce
Wall sconce 25 - “WS25” - Low Voltage Surface Mounted Luminaire Important Safety Instructions - Save These Instructions Use only with Class 2 Power Unit • These products are only suitable for connection to a Class 2 power source and have not been evaluated for use when connected to a power source that does not comply with Class 2 voltage and energy limited supplies. all installations of sunstar25 should be performed by a certified electrician and be in compliance with the national electricians code as well as local codes. Solid State LED WS25 Interior / Exterior Wall sconce Suitable for Wet locations CONSIGNES DE SÉCURITÉ IMPORTANTES - CONSERVEZ SOIGNEUSEMENT CES INSTRUCTIONS A UTILISER UNIQUEMENT AVEC UNE SOURCE D’ALIMENTATION DE CLASSE 2 • Ces produits doivent être branchés uniquement à une source d’alimentation de classe 2 et n’ont pas été testés pour une utilisation lors d’une connexion à une source d’énergie non conforme à la tension de classe 2 et à l’approvisionnement en énergie limitées. Ce produit doit Étre installÉ selon le code d’installation pertinent, par une personne qui connaÍt bien le produit et son fonctionnement ainsi que les risques inhÉrents. COMPATIBLE AVEC DES ENVIRONNEMENTS MOUILLES. Model Max Input Voltage (Vdc) Max Current (mA) Max Wattage WS25 24 1400 15 Fixture Wiring: E338721 R(+) Driver Contact: R(+) WS25 B(-) B(-) To Driver Certification: R(+) R(+) WS25 4811 Quail Crest Place Lawrence, KS 66049 www.sunlitest.com T:785.856.0219 UL and cUL Wet Location Listed IP66 Rated B(-) B(-) Energy: >0.9 Power Factor 700mA / ~ 20VDC -30° C to 40°C Suggested wiring utilizes bullet connections in alignment with the direction of current flow from the driver. Fixture Installation Instructions: Turn power off before any installation, inspection or removal of fixture/wiring. single-gang box, #8-32 Hanger Bolts and Acorn Finishing Nuts are supplied by others. single-gang box should be completely installed before attempting to install this fixture. 1 Once single-gang box is completely installed, outfit the exposed wires with bullet connections. •Red (+) with a female bullet connector. •Black (-) with a male bullet connector. 2 Push wires back into wall and screw in acorn finishing nuts over the hanger bolts to secure fixture on wall. 3 Outfit the fixture wires with bullet connections and then connect bullet connections from fixture wires and driver wires together. Dimming Wiring: Switch to Driver Diagrams: B A E C D A C F H E F B G D H G Accessories: Recommended Switch is Leviton Slide Dimmer with Locator Light On/Off Preset Switch (IP710-DLZ) A B C D Red Individually Capped 3-Way Switch when not used Green Ground Wire 120 VAC Hot Black Red to Black VAC Connection between Switch and Driver E F G H 0-10 VDC Grey and Purple Dimming Wires Black and Red to Lamps 120 VAC Neutral Wire Orange Individually Capped TS Wire 0-10V Dimmer Switch Installation Instructions: 1 2 For Dimming, a 0-10V Dimmer must be used. Wire Switches are as shown in the image: • Wires that are not being utilized must be capped individually. • If dimming function of LED drive is not being utilized, cap grey and purple wires individually. Driver Recommendations: Non-Dimmable Driver Suggestion 1 Module with 1 Chip 1 Module with 2 Chips 1 module with 3 or 6 Chips 3 to 8 in a series 2 to 4 in a series 1 or 2 in a series LPLC-18-700 9 to 15 in a series 4 to 7 in a series 3 to 5 in a series LPC-35-700 2 series of 10/11/12/13/14 fixtures in parallel total fixtures: 20/22/24/26/28 2 series of 10/12/14 fixtures in parallel total fixtures: 20/24/28 2 series of 3/4/5 fixtures in parallel total fixtures: 6/8/10 PLN-60-48 6 to 8 in a series 3 or 4 in a series 2 in a series RSLD035-7A 8 to 10 in a series 5 in a series 3 in a series RSLD035-9A 10 to 13 in a series 5 or 6 in a series 4 in a series RSLD035-12 14 to 18 in a series 7 to 9 in a series 5 or 6 in a series RSLD035-16 2 series of 12/13/14 fixtures in parallel total fixtures: 24/26/28 2 series of 6/7 fixtures in parallel total fixtures: 12/14 2 series of 4/5 fixtures in parallel total fixtures: 8/10 RSLD070-14 Dimmable Number of Fixtures Number of Chips www.Sunlitest.com Connect 4811 Quail Crest Place Lawrence, KS 66049 T: 785.856.0219 08/19/14