fire station no. 66 addition
Transcription
fire station no. 66 addition
C C INSULATED WALL SYSTEM Cx Cx PRE-FINISHED METAL JAMB TRIM BY METAL BUILDING SYSTEM MANUFACTURER CAULKING + BACKER ROD EXTERIOR 16 22 22 184 50 N.I.C. SHIM SPACE c/w SPRAY FOAM INSULATION W1 PAINTED 16mm GYPSUM WALL BOARD WINDOW SILL 380 102 Cx STEEL SUPPORT COVER SUPPORT BY METAL BUILDING SYSTEM MANUFACTURER SHIM SPACE c/w SPRAY FOAM INSULATION PRE-FINISHED METAL EDGE COVER BY METAL BUILDING SYSTEM MANUFACTURER CAULKING + BACKER ROD FIBERGLASS WINDOW FOR / POUR PRE-FINISHED METAL HEADER FLASHING C/W DRIP EDGE BY METAL BUILDING SYSTEM MANUFACTURER CAULKING + BACKER ROD SHIM SPACE c/w SPRAY FOAM INSULATION 19mm PLYWOOD BOX STEEL JAMB SUPPORT BY METAL BUILDING SYSTEM MANUFACTURER 184 CAULKING + BACKER ROD 380 PRE-FINISHED METAL HEADER FLASHING C/W DRIP EDGE BY METAL BUILDING SYSTEM MANUFACTURER CAULKING + BACKER ROD CITY OPERATIONS PORTFOLIO FIRE SERVICES BRANCH C 50 W1 102 FIBERGLASS WINDOW INFRASTRUCTURE SERVICES & COMMUNITY SUSTAINABILITY / SERVICES D'INFRASTRUCTURE ET VIABILITÉ DES COLLECTIVITÉS INFRASTRUCTURE SERVICES BRANCH / DIRECTION D'INFRASTRUCTURE DESIGN AND CONSTRUCTION DIVISION / DIVISION DE LA CONCEPTION ET DE LA CONSTRUCTION KENT KIRKPATRICK, CITY MANAGER / DIRECTEUR DES SERVICES MUNICIPAUX WAYNE NEWELL, DIRECTOR / DIRECTEUR ROBERT VAILLANCOURT, O.A.A. MANAGER / GESTIONNAIRE O.A.O. SELF ADHERED AIR / VAPOUR BARRIER 19mm PLYWOOD BOX 19mm PLYWOOD BOX N.I.C. W1 N.I.C. `ps=^o`efqb`qp EXTERIOR 16 PAINTED 16mm GYPSUM WALL BOARD WINDOW HEAD PAINTED 16mm GYPSUM WALL BOARD 22 22 STEEL SILL SUPPORT BY METAL BUILDING SYSTEM MANUFACTURER SELF ADHERED AIR VAPOUR BARRIER FIBERGLASS WINDOW 16 22 22 184 50 102 380 pìëí~áå~ÄäÉ=ÇÉëáÖå `çåÅÉéíáçå=ÉÅçäçÖáèìÉ SNPKTOVKPPSO ïïïKÅëîKÅ~ SNPKRSQKUNNU QMOJNMSS=pçãÉêëÉí=píK=tI=líí~ï~I=lk=hNv=QqP `lkpriq^kqp 1 A802 SECTION DETAIL - TYPICAL WINDOW HEAD SECTION DETAIL - TYPICAL WINDOW SILL 2 1:5 A802 3 1:5 A802 PLAN DETAIL - TYPICAL WINDOW JAMB NK=`fsfi ===j`fkqlpe=mboov 1:5 OK=pqor`qro^i ===j`fkqlpe=mboov 5 5 380 380 190 190 190 88 GALVANIZED STEEL SECTIONAL DOOR FRAME 190 GALVANIZED STEEL SECTIONAL DOOR FRAME STEEL BRACKET WELDED TO FRAME AND ANCHORED TO CONCRETE STEEL BRACKET WELDED TO FRAME AND ANCHORED TO CONCRETE FILL VOID WITH SPRAY FOAM INSULATION FILL VOID WITH SPRAY FOAM INSULATION LINE OF WALL ABOVE CONTINUOUS CALKING PK=jb`e^kf`^iJbib`qof`^i pjfqe=C=^kaboplk 5 102 88 EXTERIOR LINE OF EXTERIOR WALL PANEL LINE OF DOOR FRAME ABOVE CONTINUOUS CALKING NEW APPARATUS BAY 101 CONTROL JOINT W1* PRE-FINISHED METAL JAMB TRIM BY METAL BUILDING SYSTEM MANUFACTURER CONTINUOUS CALKING LINE OF EXTERIOR WALL ABOVE LINE OF DOOR FRAME ABOVE T/O CONCRETE SLAB 0 PRE-FINISHED METAL JAMB TRIM BY METAL BUILDING SYSTEM MANUFACTURER CONTINUOUS CALKING CONTINUOUS CALKING PRE-FINISHED METAL END CAP. EXTENDED FROM DOOR HEAD DOWN TO W1* BLOCK WALL CONTINUOUS CALKING NEW APPARATUS BAY 101 2x4" WOOD BLOCKING DESIGNED BY / CONCU PAR CONCRETE PER STRUCTURAL 140 51mm RIGID INSULATION 102 324 50 184 UNDERSLAB INSULATION 22 22 19 51 380 4 A802 PLAN DETAIL - SECTIONAL DOOR JAMB AT W1* WALL 1:5 A802 200 15mil POLY VAPOUR BARRIER PLAN DETAIL - SECTIONAL DOOR JAMB AT W1 WALL 5 DETAIL NUMBER SHEET NUMBER NEW 45mm SECTIONAL DOOR WITH 75mm TRACK 50 =N=W=R GRANULAR PER GEOTECHNICAL INSULATED WALL SYSTEM 102 SCALE 1 DRAWING TITLE A1.1 SCALE: W1 INSULATED WALL SYSTEM oKcK oKkK=L=jK`K 50mm SAND STEEL COLUMN - BY METAL BUILDING SYSTEM MANUFACTURER DATE: (Y/M/D) INITIALS/ (A/M/J) INITIALES CHECKED BY / VERIFIE PAR oKkK ASPHALT DRIVEWAY OMNSLMPLNM OMNSLMPLMN OMNSLMNLOV MILESTONE / FAIT SAILLANT DRAWN BY / DESSINE PAR WOOD BLOCKING W1* NUMBER/ NUMÉRO 2% 75 STEEL COLUMN - BY METAL BUILDING SYSTEM MANUFACTURER fpprba=clo=qbkabo fpprba=clo=_rfiafkd=mbojfq fpprba=clo=VVB=`ifbkq=obsfbt 200 LINE OF EXTERIOR WALL ABOVE S R Q 6 1:5 A802 THIS DRAWING IS THE PROPERTY OF THE CITY OF OTTAWA AND ALL COPYRIGHT IS RESERVED. DIMENSIONS ON DRAWING ARE FOR ESTIMATING PURPOSES ONLY. IT IS THE RESPONSIBILITY OF EACH CONTRACTOR AND SUB-CONTRACTOR OR CONSULTANT TO CHECK AND VERIFY ALL DIMENSIONS AND CONDITIONS ON SITE. NOTIFY OWNER OF ANY ERRORS OR OMISSIONS PRIOR TO COMMENCING THE WORK. DO NOT SCALE THE DRAWINGS. CE DESSIN CONSTITUE LA PROPRIÉTÉ DE LA VILLE D'OTTAWA ET TOUT DROIT D'AUTEUR EST RÉSERVÉ. LES DIMENSIONS UTILISÉES LE SONT À DES FINS D'ESTIMATION SEULEMENT. IL INCOMBE À CHAQUE ENTREPRENEUR, SOUS-CONTRACTANT OU CONSULTANT DE VÉRIFIER TOUTES LES DIMENSIONS ET LES CONDITIONS SUR LE CHANTIER. VEUILLEZ INFORMER LE PROPRIÉTAIRE DE TOUTE ERREUR OU OMISSION AVANT D'ENTAMER LES TRAVAUX. NE DRESSEZ PAS LES PLANS À L'ÉCHELLE. SECTION DETAIL: DOOR SILL AT SECTIONAL DOOR 1:5 `lkpqor`qflk=ao^tfkd CAULKING + BACKER ROD 5 N.I.C. PRE-FINISHED METAL EDGE COVER TRIM BY METAL BUILDING SYSTEM MANUFACTURER 380 184 22 CAULKING + BACKER ROD 22 19 Cx PRESSED STEEL THERMALLY BROKEN DOOR FRAME SHIM SPACE c/w SPRAY FOAM INSULATION PROJECT / LOCATION / PROJET / ENDROIT 380 19mm EXTERIOR GRADE PLYWOOD CAULKING + BACKER ROD PRE-FINISHED METAL END N.I.C. CAP. EXTENDED FROM DOOR HEAD DOWN TO W1* BLOCK WALL SELF ADHERED AIR VAPOUR BARRIER PRE-FINISHED METAL HEADER TRIM C/W DRIP EDGE 19mm PLYWOOD BOX CONTINUOUS CALKING STEEL DOOR JAMB SUPPORT BY METAL BUILDING SYSTEM MANUFACTURER CONTINUOUS CALKING N.I.C. 184 PRE-FINISHED METAL EDGE COVER TRIM C 50 2 LAYERS OF 2x4 WOOD BLOCKING CONTINUOUS CALKING PAINTED MDF CASING GALVANIZED STEEL SECTIONAL DOOR FRAME 16 `WyrëÉêëyÅ~êÇÉ~äyaçÅìãÉåíëyOMNRJMSRM=aìåêçÄáå=cáêÉ=pí~íáçå||Å~êÇÉ~äKêîí PRE MANUFACTURED INSULATED WALL PANEL `ps=^o`efqb`qp 102 W1 2x4" WOOD BLOCKING cáäÉ=k~ãÉ=~åÇ=içÅ~íáçåW EXTERIOR 22 22 STEEL BEAM - BY PRE-ENGINEERED STEEL FRAMING MANUFACTURER 50 W1 102 THIS "ISSUED FOR CONSTRUCTION" ISSUE IS SOLELY FOR THE CONVENIENCE OF THE CONTRACTOR AND DOES NOT ALLEVIATE THE RESPONSIBILITY OF THE CONTRACTOR FOR ENSURING THAT ALL ADDENDUM ITEMS AND APPROVED CCN BE INCORPORATED AS PART OF THE CONTRACT. FIRE STATION NO. 66 ADDITION 3285 Dunrobin Road Ottawa, Ontario CSV Project No: 2015-0650 DRAWING / DESSIN LINE OF EXTERIOR WALL BEHIND STEEL BRACKET WELDED TO FRAME AND ANCHORED TO CONCRETE N.I.C. TAPED CORNER allo=^ka=tfkalt=abq^fip FILL VOID WITH SPRAY FOAM INSULATION LINE OF DOOR FRAME BEHIND 7 A802 SECTION DETAIL - DOOR HEADER AT SECTIONAL DOOR 1:5 8 A802 PLAN DETAIL - TYPICAL DOOR JAMB DETAIL BUSINESS ENTITY / NUMÉRO DE L'ENTITÉ SHEET NO. / FEUILLE No. BUILDING NUMBER / NUMÉRO DU BÂTIMENT 1:5 PROJECT NO. / NUMÉRO DE PROJET ^UMO mäçííÉÇ=låW MVLMPLOMNS=NNWNVWPR=^j