CPF-38 Lennox Peninsula

Transcription

CPF-38 Lennox Peninsula
MERIT™ SERIES CPF-38
Appliance Specifications
12 ¹⁄₂"
(318 mm)
12 ¹⁄₂"
(318 mm)
10 ¹⁄₂"
(267 mm)
5 ¹⁄₄"
(133 mm)
48 ³⁄₄"
(1238 mm)
48 ³⁄₄"
(1238 mm)
32"
(813 mm)
42 ¹⁄₂"
(1080 mm)
Combustion Air
21"
(533 mm)
3 ⁷⁄₈"
(98 mm)
5 ³⁄₄"
(146 mm)
8 ⁹⁄₁₆"
(217 mm)
8 ¹³⁄₁₆"
(224 mm)
38" (965 mm)
39 ¹⁄₄" (997 mm)
End View
Front View
23 ¹⁵⁄₁₆"
(608 mm)
25 ³⁄₁₆"
(640 mm)
8"
(203 mm)
Model
CPF-38
Part Number
052011
Weight
210 lbs.
39 ¹⁄₄"
(997 mm)
Top View
Note: All specifications, ratings and dimensions are subject to change without notice.
Fireplace Finishes
Mantels And Trim
Vertical Surround Limitations
Hearth Extensions & Wall Shields
Combustible mantels and trim may be installed 12" (305 mm) above the fireplace
opening as per NFPA 211; Section 7-2.3.3.
and the Mantel limitation diagram. If a mantel is of a noncombustible material, it is exempt from these requirements as long as it
does not interfere with the installation or operation of glass doors.
Combustible materials may project
beyond the sides of the fireplace opening
as long as they are kept within the shaded
areas illustrated in the diagram below.
A hearth extension must be installed with all
fireplaces. Its purpose is twofold. It protects a
combustible floor in front of the fireplace from
both radiant heat and sparks and it distinguishes the prescribed hearth extension area
from other non-protected surfaces.
Combustible
Materials Allowed
in Shaded Area
1" (25 mm)
8"
(203 mm)
Max.
1 ¹⁄₂"
(38 mm)
Combustible
Mantel
and Trim
12"
(305 mm)
Min.
Side Wall
8" (203 mm) Min.
to Fireplace Opening
Spacer
30˚
False
Header
End Opening
Hearth
Extension
8" (203 mm)
Minimum Distance
to Side Wall
25 ³⁄₁₆"
Finished Wall
5 ¹⁄₄"
(133 mm)
C
B
C
Fireplace Opening
U.S. Mantel Limitations
(See Installation Instructions for Canadian Installation)
A
Opening Width
A - 16" (406 mm)
B - 28 ¹⁄₂" (724 mm)
C - 8" (203 mm)
D - 44 ¹⁄₂" (1130 mm)
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
775,624M Rev. A 04/07
MERIT™ SERIES CPF-38
Framing Specifications
Note: All framing dimensions calculated for ¹⁄₂" dry wall at the
appliance face. If sheathing the chase or finishing with other thickness
materials, calculations will need to be made.
Typical Installation
Chimney and
Termination
49"
(1245 mm)
End View
42 ³⁄₄"
(1086 mm)
Framing Dimensions for Roof
Right Front View
FTF8 at 2" (51 mm)
Pitch
C
D*
0/12
16 ¹⁄₂"
(419 mm)
16 ¹⁄₂"
(419 mm)
6/12
16 ¹⁄₂"
(419 mm)
19"
(483 mm)
12/12
16 ¹⁄₂"
(419 mm)
23 ¹⁄₂"
(597 mm)
D
C
4 x 4 Header
Roof Framing
2x4
False Header
(Optional)
* Perpendicular to Roof Ridge.
Framing Dimensions for Ceiling
Ceiling Opening
Flue Type
A
B
FTF8,
Vertical
at 2"
(51 mm)
16 ¹⁄₂"
(419 mm)
16 ¹⁄₂"
(419 mm)
FTF8,
Offset
At 2"
(51 mm)
16 ¹⁄₂"
(419 mm)
*24 ³⁄₁₆"
(614 mm)
Maximum
B
7" Min.
(178 mm)
27"
(686 mm)
*39 ¹⁄₄"
(997 mm)
Maximum
49"
(1245 mm)
42 ³⁄₄"
(1086 mm)
A
Ceiling Framing
*Dimensions Calculated For 1/2” Drywall
Framing
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
775,624M Rev. A 04/07