Control with LCD display - Voltage - Current
Transcription
Control with LCD display - Voltage - Current
Control with LCD display - Voltage - Current ➜ HDU / HDI ■ ■ ■ ■ ■ ■ Displays the current value and the preset value on LCD Controls AC and DC signals (automatic detection) Selectable overload or underload mode Threshold and hysteresis can be adjusted separately Memory function in case of fault Delay on threshold crossing le ilab a v a a ny n N o e rm in G le lab v a i ny a Non erma in G Specifications HDU - L HDU - H HDI - L HDI - H Measurement ranges Supply voltage 24 DC 24 VAC 120 VAC 230 VAC 0.2 to 60 V 15 to 600 V 2 to 500 mA 0.1 to 10 A 84 872 301 84 872 302 84 872 304 84 872 305 84 872 306 84 872 307 84 872 309 84 872 310 84 871 301 84 871 302 84 871 304 84 871 305 84 871 306 84 871 307 84 871 309 84 871 310 Input circuits E1-M : 0.2 - 2 V E2-M : 1 - 10 V E3-M : 6 - 60 V E1-M : 2 kΩ E2-M : 10kΩ E3-M : 60kΩ E1-M : 4 V E2-M : 20 V E3-M : 120 V E1-M : 50 V E2-M : 100 V E3-M : 300 V Mains 277 / 480 VAC E1-M : 15 - 150 V E2-M : 30 - 300 V E3-M : 60 - 600 V E1-M : 100 kΩ E2-M : 300 kΩ E3-M : 650 kΩ E1-M : 200 V E2-M : 350 V E3-M : 650 V E1-M : 2 kV E2-M : 2 kV E3-M : 2 kV Mains 277 / 480 VAC E1-M : 2 - 20 mA E2-M : 10 - 100 mA E3-M : 50 - 500 mA E1-M : 5 Ω E2-M : 1 Ω E3-M : 0,2 Ω E1-M : 40 mA E2-M : 200 mA E3-M : 1 A E1-M : 1 A E2-M : 5 A E3-M : 8 A Mains 277 / 480 VAC E1-M : 0,1 - 1 A E2-M : 0,5 - 5 A E3-M : 1 - 10 A E1-M : 0,1 Ω E2-M : 0,02 Ω E3-M : 0,01 Ω E1-M : 2 A E2-M : 10 A E3-M : 14 A E1-M : 17 A E2-M : 20 A E3-M : 50 A Mains 277 / 480 VAC Input resistance 4 Maximum permanent voltage at 20 oC Peak overload < 1ms at 20 oC Max. line voltage Dimensions HDI / HDU 66 36 11 E3 E2 E1 45 81 A1 A2 14 12 M 3 3 130 50 For more information www.crouzet.com Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com General characteristics Supply Supply voltage Operating range Maximum power consumption Immunity from micro power cuts Delay on pick-up Insulation coordination Output circuit Output Minimum current Mechanical life (operations) Maximum rate Electrical life (A) General characteristics Delay on threshold crossing Display on LCD Class of protection (529) - Term. block Protection class (IEC 529) - Panel-mounted Class of protection (IEC 529) - Casing Material housing Weight (g) Terminal capacity Tightening Temperature limits used (°C) Temperature limits stored (°C) Relative humidity (no condensation) Dielectric strength Hysteresis Frequency of measured signal Threshold display accuracy Repetition accuracy (with constant parameters) Drift Temperature Drift Voltage For more information www.crouzet.com 230, 120, 24 V AC 50 / 60 Hz 24 V DC no galvanic isolation protected against polarity reversal 0.85 to 1.10 x Un 3 VA at 230, 120 and 24 V AC 1 W at 24 VDC 10 ms 500 ms Category III Degree of pollution 2 according to IEC 664-1 VDE 0110 : 4 KV/2 1 AgCdO changeover relay 5 A - 250 V 100 mA 5 x 106 360 operations / h at full load AC 12 : 1250 VA - 105 operations AC 15 : cosϕ = 0.3 - 6000 operations DC 13 : L/R = 300 ms - 6000 operations 0.1 to 3 sec ± 10 % Relay status OVER or UNDER mode Memory function Type of signal (AC or DC) Measurement overflow IP 20 IP 40 IP 50 Self-extinguishing 160 2 x 1.5 mm2 with ferrule 2 x 2.5 mm2 without ferrule 0.6 mN max. - 20 ● + 60 oC -30 ● +70 °C 93 % (+2 % -3 %) CEI 255.5, 2.5 KV / 1 min / 1 mA / 50 Hz Adjustable from 5 to 50 % of threshold 40 ➞ 500 Hz ± 10 % ±0.1 % ±0.05 % / °C ≤ 0.5 % 4 131 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com Connections HDI / HDU HDU U ~ ~+ + E1 E2 E3 (+) (+) (+) A1 11 S1 L1 (+) R A1 11 U >< E1 E2 E3 R A2 M(-) 12 14 12 14 ~ DC - 1 M A2 (-) (-) OV L2 ~_ B AC or DC voltage to be controlled HDI N R S T AR D1 d1 MA 4 (+) A1 11 E1 E2 E3 R 12 14 Y2 Y1 M A2 DC U V W (-) (-) OV M 3~ 132 For more information www.crouzet.com Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com Principles Operating principle These devices are designed to control an AC or DC electrical signal : voltage using HDUs, current using HDIs. The threshold and hysteresis can be adjusted separately via two potentiometers on the front face. Before powering up the device, the operating mode should be selected using two dipswitches located under the device (with/without memory, over/under value). The mode is validated when power is applied to terminals A1 - A2. The signal to be monitored is connected between terminals E1, E2, or E3 (depending on the range) and terminal M. Control of voltage (HDU) or current (HDI) without memory T When the value of the controlled signal, AC or DC, reaches the threshold set on the front face, the output relay opens (failsafe) at the end of time delay T. It closes immediately when the signal goes below (or above in under value mode) the threshold minus hysteresis (plus hysteresis in under value mode). T U 5 Notes 1 The threshold crossing time delay T, which can be adjusted on the front face from 0.1 to 3 sec, ensures immunity to transients and other inferference, thus preventing spurious triggering of the output relay. 2 In "under value" mode, the absolute value of the hysteresis cannot be more than the maximum of 3 5 the measurement range. 4 B Threshold C Oper. R Overload D Threshold E Oper. R Underload F Hysteresis Control of voltage (HDU) or current (HDI) with memory 4 When the threshold is reached, the output relay opens at the end of time-out T and remains in that position. To reset the relay, the supply must be cut. This operating mode enables the detection of over or under values of short duration. 6 T U 5 1 2 3 5 B Threshold C Oper. R Overload D Threshold E Oper. R Underload F Hysteresis G Memory 4 T For more information www.crouzet.com 6 133 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com