Control with LCD display - Voltage - Current

Transcription

Control with LCD display - Voltage - Current
Control with LCD display - Voltage - Current
➜ HDU / HDI
■
■
■
■
■
■
Displays the current value and the preset value on LCD
Controls AC and DC signals (automatic detection)
Selectable overload or underload mode
Threshold and hysteresis can be adjusted separately
Memory function in case of fault
Delay on threshold crossing
le
ilab
a v a a ny
n
N o e rm
in G
le
lab
v a i ny
a
Non erma
in G
Specifications
HDU - L
HDU - H
HDI - L
HDI - H
Measurement ranges
Supply voltage
24 DC
24 VAC
120 VAC
230 VAC
0.2 to 60 V
15 to 600 V
2 to 500 mA
0.1 to 10 A
84 872 301
84 872 302
84 872 304
84 872 305
84 872 306
84 872 307
84 872 309
84 872 310
84 871 301
84 871 302
84 871 304
84 871 305
84 871 306
84 871 307
84 871 309
84 871 310
Input circuits
E1-M : 0.2 - 2 V
E2-M : 1 - 10 V
E3-M : 6 - 60 V
E1-M : 2 kΩ
E2-M : 10kΩ
E3-M : 60kΩ
E1-M : 4 V
E2-M : 20 V
E3-M : 120 V
E1-M : 50 V
E2-M : 100 V
E3-M : 300 V
Mains 277 / 480 VAC
E1-M : 15 - 150 V
E2-M : 30 - 300 V
E3-M : 60 - 600 V
E1-M : 100 kΩ
E2-M : 300 kΩ
E3-M : 650 kΩ
E1-M : 200 V
E2-M : 350 V
E3-M : 650 V
E1-M : 2 kV
E2-M : 2 kV
E3-M : 2 kV
Mains 277 / 480 VAC
E1-M : 2 - 20 mA
E2-M : 10 - 100 mA
E3-M : 50 - 500 mA
E1-M : 5 Ω
E2-M : 1 Ω
E3-M : 0,2 Ω
E1-M : 40 mA
E2-M : 200 mA
E3-M : 1 A
E1-M : 1 A
E2-M : 5 A
E3-M : 8 A
Mains 277 / 480 VAC
E1-M : 0,1 - 1 A
E2-M : 0,5 - 5 A
E3-M : 1 - 10 A
E1-M : 0,1 Ω
E2-M : 0,02 Ω
E3-M : 0,01 Ω
E1-M : 2 A
E2-M : 10 A
E3-M : 14 A
E1-M : 17 A
E2-M : 20 A
E3-M : 50 A
Mains 277 / 480 VAC
Input resistance
4
Maximum permanent voltage at 20 oC
Peak overload < 1ms at 20 oC
Max. line voltage
Dimensions
HDI / HDU
66
36
11 E3 E2 E1
45
81
A1
A2 14 12
M
3
3
130
50
For more information www.crouzet.com
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
General characteristics
Supply
Supply voltage
Operating range
Maximum power consumption
Immunity from micro power cuts
Delay on pick-up
Insulation coordination
Output circuit
Output
Minimum current
Mechanical life (operations)
Maximum rate
Electrical life (A)
General characteristics
Delay on threshold crossing
Display on LCD
Class of protection (529) - Term. block
Protection class (IEC 529) - Panel-mounted
Class of protection (IEC 529) - Casing
Material housing
Weight (g)
Terminal capacity
Tightening
Temperature limits used (°C)
Temperature limits stored (°C)
Relative humidity (no condensation)
Dielectric strength
Hysteresis
Frequency of measured signal
Threshold display accuracy
Repetition accuracy (with constant parameters)
Drift Temperature
Drift Voltage
For more information www.crouzet.com
230, 120, 24 V AC 50 / 60 Hz
24 V DC no galvanic isolation
protected against polarity reversal
0.85 to 1.10 x Un
3 VA at 230, 120 and 24 V AC
1 W at 24 VDC
10 ms
500 ms
Category III
Degree of pollution 2
according to IEC 664-1
VDE 0110 : 4 KV/2
1 AgCdO changeover relay 5 A - 250 V
100 mA
5 x 106
360 operations / h
at full load
AC 12 : 1250 VA - 105 operations
AC 15 : cosϕ = 0.3 - 6000 operations
DC 13 : L/R = 300 ms - 6000 operations
0.1 to 3 sec ± 10 %
Relay status
OVER or UNDER mode
Memory function
Type of signal
(AC or DC)
Measurement overflow
IP 20
IP 40
IP 50
Self-extinguishing
160
2 x 1.5 mm2 with ferrule
2 x 2.5 mm2 without ferrule
0.6 mN max.
- 20 ● + 60 oC
-30 ● +70 °C
93 % (+2 % -3 %)
CEI 255.5, 2.5 KV / 1 min / 1 mA / 50 Hz
Adjustable from 5 to 50 % of threshold
40 ➞ 500 Hz
± 10 %
±0.1 %
±0.05 % / °C
≤ 0.5 %
4
131
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
Connections
HDI / HDU
HDU
U
~
~+
+
E1 E2 E3
(+) (+) (+)
A1
11
S1
L1
(+)
R
A1 11
U ><
E1 E2 E3
R
A2
M(-)
12
14
12 14
~
DC
-
1
M A2
(-)
(-) OV
L2
~_
B AC or DC voltage to be controlled
HDI
N
R S
T
AR
D1
d1
MA
4
(+)
A1 11
E1 E2 E3
R
12 14 Y2 Y1 M A2
DC
U V W
(-)
(-) OV
M
3~
132
For more information www.crouzet.com
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
Principles
Operating principle
These devices are designed to control an AC or DC electrical signal : voltage using HDUs, current using HDIs.
The threshold and hysteresis can be adjusted separately via two potentiometers on the front face. Before powering up the device, the operating mode
should be selected using two dipswitches located under the device (with/without memory, over/under value). The mode is validated when power is
applied to terminals A1 - A2.
The signal to be monitored is connected between terminals E1, E2, or E3 (depending on the range) and terminal M.
Control of voltage (HDU) or current (HDI) without memory
T
When the value of the controlled signal, AC or DC, reaches the threshold set on the front face, the
output relay opens (failsafe) at the end of time delay T. It closes immediately when the signal goes
below (or above in under value mode) the threshold minus hysteresis (plus hysteresis in under
value mode).
T
U
5 Notes
1
The threshold crossing time delay T, which can be adjusted on the front face from 0.1 to 3 sec,
ensures immunity to transients and other inferference, thus preventing spurious triggering of the
output relay.
2
In "under value" mode, the absolute value of the hysteresis cannot be more than the maximum of
3
5 the measurement range.
4
B Threshold
C Oper. R Overload
D Threshold
E Oper. R Underload
F Hysteresis
Control of voltage (HDU) or current (HDI) with memory
4
When the threshold is reached, the output relay opens at the end of time-out T and remains in that
position.
To reset the relay, the supply must be cut.
This operating mode enables the detection of over or under values of short duration.
6
T
U
5
1
2
3
5
B Threshold
C Oper. R Overload
D Threshold
E Oper. R Underload
F Hysteresis
G Memory
4
T
For more information www.crouzet.com
6
133
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com