PXA30-RS, PXA30-RS1,PXA30-RS2 Extension modules for

Transcription

PXA30-RS, PXA30-RS1,PXA30-RS2 Extension modules for
9
281
DESIGO™ PX
Extension modules
for RS232 and RS485
PXA30-RS
PXA30-RS1
PXA30-RS2
.
.
.
.
.
.
.
.
for the integration of third-party products
•
Integration of third-party equipment and systems into the DESIGO building
automation and control system at the automation level
•
Plugs into the PXC00-U system controller or thePXC64-U and PXC128-U
modular automation stations
Functions
Integration of third-party equipment and systems into the BACnet automation level
• Mapping and monitoring of third-party disciplines such as HVAC, lighting, PLCs etc.
• Operates as a freely programmable system controller (like an automation station but
without physical inputs and outputs) for standard or proprietary protocol solutions
• Supports the monitoring of communications on the third-party bus with the
PX Open Monitor tool.
CM1N9281en_02
30.03.2007
Building Technologies
.
.
.
Topology
DESIGO INSIGHT
PXM20, PXM20-E
BACnet / LON, BACnet / IP
QAX...
PPS2
PXC...
PXC...-U
9281z01 en
PXA30-RS
PXC...-U
PX-OPEN Monitor
... bus
Third party devices / systems
Types
PXA30-RS
PXA30-RS1
PXA30-RS2
Extension module for RS232 and RS485, up to 100 data points
Extension module for RS232 and RS485, up to 400 data points
Extension module for RS232 and RS485, up to 2000 data points
(SCL: 1000 data points)
.
.
.
.
.
.
.
Compatibility
The module is plugged into a PXC00-U system controller or a PXC64-U or
PXC128-U automation station.
Ordering
When ordering, please specify the quantity, product name and type code.
Example:
30
Extension modules
PXA30-RS
2/8
Siemens
Building Technologies
PXA30-RS, PXA30-RS1, PXA30-RS2 – Extension modules for RS232 and RS485
CM1N9281en_02
30.03.2007
.
.
.
Mechanical design
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
• Two-part snap-together housing (plastic)
• Cover for contact protection
• PCB with electronic components
• RS485 connection terminals, 3-pole
• RS232 D-sub 9-pin male connector
• LED indication
RX
TX
9281Z02
9281Z06
S
Mounting
The extension module is plugged into the PXC00-U system controller or PXC64-U or
PXC128-U automation station.
It is important to follow the instructions supplied with the device, in particular:
.
.
.
• Avoid touching the connector pins (ESD precautions)
• Push the module firmly into position (1.5 mm) and check that it is securely in place
so that the fine contact pins interlock properly.
2
1 Plug-in unit
1
4
2 Device base
3
.
.
.
9281z02
3 PXA30-RS… extension module
(always to the right)
4 Other extension modules (commonly PXA30-N)
Note:
The PXA30-T and PXA30-NT also
have a D-sub 9-pin connector.
However, this is used for the modem
connection to DESIGO.
3/8
Siemens
Building Technologies
PXA30-RS, PXA30-RS1, PXA30-RS2 – Extension modules for RS232 and RS485
CM1N9281en_02
30.03.2007
Engineering
Engineering is carried out with the DESIGO TOOLSET (DTS):
• The project is created with SYSTEM DESIGN (DTS-SD)
• The completed project is exported to DTS-PX
Development environment
• PX SCL is available for free programming on PXC00-U, PXC64-U and PXC128-U
modules fitted with the PXA30-RS… extension module
• The PXA30-RS… extension modules do not support software tools for development
of custom applications. These individual applications must be developed on the
PXE-CRS platform.
Commissioning on the BACnet side
Commissioning on the automation side (BACnet) is carried out with DESIGO
TOOLSET (DTS).
• An address is assigned to the device
• The application (for the coordination of the HVAC functions at the automation level)
and the mapping tables for the field level are downloaded.
Addressing
Node setup via DESIGO TOOLSET
Third-party commissioning
Third-party systems are commissioned with the third-party manufacturer’s
commissioning tool.
Siemens Building Technologies provides a tool, PX OPEN Monitor, for the monitoring
and analysis of data traffic on the third-party bus. The connector for this tool is on the
front of the automation station.
Disposal
The device includes electrical and electronic components and must not be disposed of
as domestic waste.
Current local legislation must be observed.
4/8
Siemens
Building Technologies
PXA30-RS, PXA30-RS1, PXA30-RS2 – Extension modules for RS232 and RS485
CM1N9281en_02
30.03.2007
.
.
.
.
.
Technical data
RS232 interface
Use
Baud rate
Data bits
Stop bits
Parity
Flow control
Wiring
RS485 interface
Housing
protection standard
Protection class
Ambient conditions
Industry standards
Dimensions
Weight
Cable type
Cable length
Use
Baud rate, data bits / stop bit(s), parity
Wiring
Cable type
Cable length
Protection standard to EN 60529
Insulation protection class
Normal operation
Temperature
Humidity
Transport
Temperature
Humidity
Product safety
Automatic electronic controls for
household and similar use
Electromagnetic compatibility
Interference immunity
Emitted interference
CE marking
Electromagnetic compatibility
See "Dimensions"
With / without packaging
Third party
300, 600, 1200, 2400, 4800, 9600,
19200, 38400
(depends on software)
7 or 8 (depending on software)
1 or 2 (depending on software)
None, even or odd
(depending on software)
Xon/Xoff, hardware or none
(depending on software)
9-core standard screened cable
Max. 3 m
Third party (electrically separated)
As for RS232 (depends on software)
Standard RS bus cable
Max. 1200 m
IP30
.
.
.
.
.
.
.
III
Class 3K5 to IEC 721
0 ... 50 °C
< 85 % rh
Class 2K3 to IEC 721
– 25 ... 65 °C
< 95 % rh
.
.
_
_
EN 60950-1
EN 61000-6-2
EN 61000-6-2
89/336/EEC
_
_
75 g / 95 g
5/8
Siemens
Building Technologies
PXA30-RS, PXA30-RS1, PXA30-RS2 – Extension modules for RS232 and RS485
CM1N9281en_02
30.03.2007
Connections
1
2
7
4
8
1
2
3
4
5
5
9
DCD
RXD
TXD
DTR
GND
Data carrier detect
Received data
Transmit data
Data terminal ready
Signal ground
6
7
8
9
DSR
RTS
CTS
NC
Data set ready
Request to send
Clear to send
Not connected
9281Z05
6
3
9281z04
RS232 serial
RS485
+ Tx
– Rx
S Screen
S
STOP
Note
The "S" terminal is not connected to the circuit. The cable screen must be earthed in
the cabinet .
Screening
9281z20
Screen clamp
9281z22
S
Support rail
9281z21
Screen bus
S
Avoid screen pigtails!
6/8
Siemens
Building Technologies
PXA30-RS, PXA30-RS1, PXA30-RS2 – Extension modules for RS232 and RS485
CM1N9281en_02
30.03.2007
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Dimensions
111
Dimensions in mm
62
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
33
9281M01
28
S
7/8
Siemens
Building Technologies
PXA30-RS, PXA30-RS1, PXA30-RS2 – Extension modules for RS232 and RS485
CM1N9281en_02
30.03.2007
8/8
© 2006 - 2007 Siemens Switzerland Ltd.
Subject to change
Siemens
Building Technologies
PXA30-RS, PXA30-RS1, PXA30-RS2 – Extension modules for RS232 and RS485
CM1N9281en_02
30.03.2007