Tebis TS - Edmundson Electrical

Transcription

Tebis TS - Edmundson Electrical
modular devices
Tebis TS
intelligent building system
160
163
164
165
167
Tebis
Tebis
Tebis
Tebis
Tebis
TS
TS
TS
TS
TS
-
introduction
input modules
input devices
output devices
system devices
159
Tebis TS a system for residential &
commercial applications
Hager has many years
experience developing and
installing products based on Bus
technology.
Tebis TS brings the following
benefits :
■ integrate within one system
services and functions which
previously worked
independently from each other;
B
EI
EDF
■ make modifications easier ;
■ make the electrical installation
more reliable, reducing the
chance of electrocution;
The command bus transmits
information to each of the
appliances.
■ tailoring the switch commands
to ensure greater user comfort
To obtain these benefits means
installing two separate circuits, a
supply circuit to distribute
energy and the control circuit to
carry information and
instructions.
The advantages of the two
distinct circuits are many :
The supply cabling is
simplified
The only devices cabled on the
LV (240V ac) side are the loads
which need power (lights,
garage doors...)
The controls for these loads
(by push switches, thermostats. )
are connected to the bus circuit.
Grouping of instructions
One order (from a push-button.. )
can control a set of lights or
other loads or both at once (a
scenario).
Flexibility
By controlling loads using Tebis
TS, the electrical installation can
be modified and the use or configuration of the building
changed, without touching the
LV wiring.
Remote Controls
Remote control receivers (radio
or infrared) can be placed
anywhere on the bus. Any load
in the installation can then be
controlled by remote control
When Tebis TS is used. the
degree of automation is no
longer limited by the complexity
of cabling: new benefits can be
offered, which were previously
impractical...
Electrical installation with a command bus
ventilation
movable shutters,
shutters, blinds
heating
lighting
230/400 V
Bus
push button
switch
the power circuit
the control bus
160
remote control
wind strength
temperature
Tebis TS is based on simple
principles:
■ the input devices react to
orders, controls and
measures. They act on an
ON/OFF order from a switch,
measure the variation of
ambient temperature or of
light level, and transmit
orders onto the bus.
■
the output devices receive
all information and orders
travelling on the bus and
execute orders which are
addressed to them.
■
the installation Bus is the
twisted-pair cable which
serves as the information
network.
Electrical installation with bus
technology:
A developing concept
After proving itself in industrial
applications, this installation
concept is spreading to include
domestic and commercial
premises.
A concept with accumulating
advantages
■ adapts easily to the
requirements of current and
future occupants
■
gives greater conceptual
freedom to the architect
■
easy to install for the
electrician
Tebis TS uses bus technology
for the control of lighting,
heating and roller-shutters and
other similar loads, in both
residential and commercial
applications.
A small number of products
for many applications
The Tebis TS system uses only 3
types of products:
Input devices,
for transmitting to the output
devices the orders from
push-buttons or information
from thermostats or other
sensors
Bus technology offers benefits
that a traditional installation
cannot provide.
Tebis TS is easy to install.
Electrical contractors can
continue to use familiar materials
and gain precious time in
planning, then wiring, as there is
only one cable connecting each
push button to the next. Right
up to - and after - completion of
wiring, any switch can be made
to control any load : the building
user can decide at the last
minute.
Advanced lighting control
Tebis TS enables the creation of
ambient lighting as desired.
Each push-button controls a set
of lights or controls the dimming
of lights.
The Tebis TS system is particularly suitable for the home and for small
commercial premises.
Output devices,
which control the electrical loads
System devices,
for setting the relations between
inputs and outputs, or for
providing the 29V supply
Benefits of choosing Tebis TS
■
Flexibility for the user:
A single load can be
controlled from several
positions. Conversely,
several loads can be controlled from a single point.
■
Update: The function of
each switch can be changed
at any time, without touching
the wiring
Flexibility in shutter control
Shutters can be controlled
individually, by group or all
together. From push-buttons, or
even from a wind meter.
■
Larger number of
applications: Tebis TS works
with any brand of
push-buttons and electrical
load available
■
Safety : The control wiring
voltage is 29V, eliminating
the danger of electrocution
from the control circuit.
Heating at your command
From a heating regulator, Tebis
TS enables :
■ setting in comfort or
economy mode.
■
override of heaters to frost
setting
■
override of heaters to ‘off’.
Grouped controls (Scenario
Switching)
In addition to the individual
controls each Tebis TS product
offers, Tebis TS also allows
simultaneous control of several
different loads (example : lighting
& heating) from one push-button
or sensor.
161
Tebis TS examples of residential &
commercial switching scenarios
Tebis TS: a system which is
easy to install
■ All the control units are
linked to 2 bus wires via
input modules
■
All the electrical loads are
linked to the output modules
■
The allocation of links
between the push buttons
and the loads are carried out
by means of an easy to use
modular device called a
configurator
■
The configurator will make it
possible to define, for each
input, which outputs are to
be commanded and in which
way (relay, dimmer, up,
down, etc.)
After down loading this data to
the different products, the
installation is functional.
Changes or future developments
to adapt the installation to the
needs of the client are achieved
by simply reprogramming.
A system easy to configure
The configurator defines or modifies
the electrical installation
Some applications:
the "leaving home" scenario.
A single gesture is enough to:
■ Turn out all the lights
■ Lower all the shutters
■ Reduce the heating
■ Etc.
The scenario, which can be
changed at will, can be activated
with a push button in the hall, at
the garage door or by radio
remote control.
1/2.
In a sports hall
the lighting must be adapted to
the activity taking place (tennis,
volleyball, basketball, etc.) as
well as for the occasion
(matches, training, preparation,
etc).
To assist Specifiers and
Installers, Hager run
complementary training
sessions. Talk to your
Hager representative for a
current schedule of
seminars.
162
1/2.
training. matches
By assigning a push button to
each sport, it is possible to
implement the most suitable
lighting for the sport being played
with a single action, without the
need to operate several switches
which are each dedicated to a
part of the playing area.
The "projection" scenario
This makes it possible to move straight from a meeting sequence to a
projection sequence and vice-versa with a single command. As well as
managing the lighting, this command can also drive the motorised
screen and supply power to the projector.
Benefits that can be sold to the final user:
■ Tebis TS offers the highest level of comfort possible
■ Tebis TS ensures that inevitable future modifications can be
handled at least cost are are easy to do
■ Tebis TS offers the most economical control of electricity
■ Using remote controls to simplify your life
■ Adding new push buttons without touching your decor
■ Access all loads from anywhere
Tebis TS - input modules
Input devices send orders,
received from push-buttons or
sensors, to the Tebis TS output
devices, via the
twisted pair cable.
for technical details
see pages 249-264.
Description
characteristics
No. of
inputs
pack
qty.
cat.
ref.
input device flush-mounted
functions :
Inputs :
- 2 or 4 volt-free contacts
2
1
TS302
4
1
TS304
- enables connection of volt free
contacts (example : push-button)
- interprets orders and transmits
them to the output devices to
control lighting, shutters or other
electrical loads.
- all the connections are for extra
low voltage.
Supply :
- 29V bus (twisted pair)
Installation :
fits behind standard wall wiring
devices (push-button or switch)
in a wall box of minimum depth
35mm. An insulated box is
recommended
TS302
TS304
TS314
Description
characteristics
size in ❚
17.5 mm
pack
qty.
cat.
ref.
input devices, DIN-rail mounted
Inputs :
- 4 terminals rated at 230Vac
2
1
TS314
functions :
- interprets orders at 230Vac
and transmits them to the out
put devices to control lighting,
shutters or other electrical
loads.
Supply :
- 29V bus (twisted pair)
4
1
TS316
the TS314 and TS316 signals
the state of the inputs when the
29V twisted pair is switched on.
Thus, it is well adapted to
controlling
automatic devices (timers,
telephone remote-control, solar
cells, anemometers ...) It can
also be connected to
push-buttons with indicator
lamps.
Installation :
- DIN-rail
Inputs :
- 6 terminals rated at 230Vac
Supply :
- 29V bus (twisted pair)
Installation :
- DIN-rail
Note: TS310
available to satisfy
existing installations
163
Tebis TS - input devices
description
characteristics
Thermostat TS322
Used in conjunction with the
output device TS244.
TS330
TU 202
functions:
- local temperature level
adjustment.
- manual selection of comfort,
reduced and frost settings
on front face.
- remote setting via the bus of
comfort, reduced and frost
settings.
- indication of selected setting
by 2 LED’s.
Outside temperature transmission kit size in ❚
17.5 mm
pack
qty
cat.
ref.
For control of convector heaters
or underfloor heating
1
TS320
For control of conventional hot
water radiators
1
TS321
For electrical heating by
convectors, radiator panel,
radiating ceiling, etc...
1
TS322
1
TS330
supply :
- 29Vdc Bus
maximum of 4 inputs per receiver
1
TS350
supply :
- 29Vdc Bus
maximum of 12 inputs per receiver
1
TS351
key ring type:
- 2 buttons, 2 inputs
- with battery
- attaches to key ring
1
TU202
4 buttons, 4 inputs
- with battery
- wall mounting bracket
- a label for the function
of each button
1
TU204
8 buttons, 3 channels, 24 inputs
- with battery
- wall mounting bracket
- a label for the function
of each button
1
TU209
Temperature settings :
- comfort : 21OC, adjustable +
4OC
- reduced : comfort - 4OC
- frost : 7OC
Supply :
- twisted pair 29V
- indication of the setting by 2
LED’s
Installation :
- surface-mounted, on a flush
wall box 60mm dia 50mm deep
Supply :
- twisted pair 29V
4
Used in conjunction with
temperature controllers TS320,
TS321 and TS322 this kit
enables regulation of heating,
depending on the weather.
TU 204
front
rear
radio receiver (RF)
- receives orders from TU202,
TU204, TU209 and transmits
them to the bus.
TU 209
front
rear
remote control (RF)
TS 350
TS 351
164
Tebis TS - output devices
Enable control of electrical
loads, following orders from
input devices.
There are 3 types of output
devices :
- for lighting
- for small motor loads
e.g. shutters, curtains etc.
- for heating
All output devices are provided
with LED indication of the
output status and a manual
override, on the front face. The
outputs can be connected to
different phases.
description
characteristics
size in ❚
17.5 mm
pack
qty.
cat.
ref.
output devices for, ON/OFF
switching
outputs :
- 4 volt-free contacts 4A
AC1
power supply :29Vdc bus
4
1
TS204A
outputs :
- 4 volt-free contacts 16A
AC1
power supply : 29Vdc bus
4
1
TS204C
outputs :
- 6 volt-free contacts 4A
AC1
power supply : 29Vdc bus
4
1
TS206A
outputs :
- 6 volt-free contacts 10A
AC1
power supply : 29Vdc bus
4
1
TS206B
outputs :
- 6 volt-free contacts 16A
AC1
power supply : 29Vdc bus
4
1
TS206C
outputs :
- 6 volt-free contacts
3 x 16A AC1 + 3 x 6A AC1
power supply : 29Vdc bus
4
1
TS206D
outputs :
3, 1-10V outputs designed to
drive:
- EV102 and EV104 dimmers
- transformers and electronic
ballasts with 1-10V control (in
conjunction with volt free 16A
AC1 contact)
6
1
TS211
For control of :
- lighting
- power outlets
- any load controlled by a simple
contact
TS204C
Functions :
- on/off switching
- on/off override
- LED indication of each output
state
TS206B
Output modules for dimmed
lighting
Function :
- ON/OFF switching
- dimming
- dimming scenarios
power supply:
- 240Vac 50Hz
- 29Vdc Bus
TS211
TS 210
for technical details
see pages 249-264.
For :
- 240V incandescent and
halogen lamps
- ELV halogen lamps with
electronic or ferromagnetic
transformers
outputs:
- 1 direct output
- 20 - 600W/VA (30oC)
20 - 500W/VA (40oC)
240V/50Hz
power supply:
- 29Vdc bus
4
1
TS210
For :
- 240V incandescent and
halogen lamps
- ELV halogen lamps with
electronic or ferromagnetic
transformers
outputs:
- 1 direct output
- 20 - 300W/VA (40oC)
240V/50Hz
power supply:
- 29Vdc bus
4
1
TS210A
165
Tebis TS - output devices
description
characteristics
size in ❚
17.5 mm
pack
qty
cat.
ref.
Output device for 4 movable
blinds or canopy blinds
outputs :
- for 4 motors 240Vac (6A AC1)
4
1
TS223
Functions :
- operating and closing by
pressing briefly
- STOP by pressing briefly
- manual override
UP/DOWN/STOP
- LED indication of each output
state
- wind safety function
supply :
- 29Vdc Bus
Output modules for 4 slat
blinds
outputs :
- for 4 motors 240Vac (6A AC1)
4
1
TS224
Functions :
- opening and closing by
pressing for an extended time
(400ms)
- STOP by pressing briefly
- manual override
UP/DOWN/STOP
- LED indication of each output
state
- wind safety function
supply :
- 29Vdc Bus
4 output device, for heating
outputs :
- 4 volt-free contacts 16A AC1
4
1
TS244
1
TS400
1
TS003
TS223
For control of :
- underfloor heating
- electric convectors
- radiating panels
- association with TS320, TS321
and Ts322 thermostats
TS400
Functions :
- On/OFF control switching
- On/OFF override on front face
- LED indication of each output
state
4 way indicator panel Functions :
- reproduces on/off contact
status of associated output by
LED indication
telephone interface unit
application:
by linking this product to a Tebis
input device, you can control
specific Tebis system loads
remotely from a touch tone
telephone
TS003
166
supply :
- 29Vdc Bus
functions:
- 3 channel remote control
interface with voice guide
- restricted access via 4 digit
user code
- circuit status indicator light
- manual override push button
- on/off switching
- timed off switching
(1-100hours)
supply :
- 29V twisted pair (bus)
installation :
- surface mounted on a flush
wall box = 60mm dia 50mm deep
outputs:
3 volt free changeover contacts
5A 250V AC1
supply:
230V ac 50Hz
Tebis TS - system devices
description
characteristics
size in ❚
17.5 mm
pack
qty
cat.
ref
Control device supply :
- 230Vac 50Hz
- 29V twisted pair (bus)
6
1
TS100
supply :
- 230Vac 50Hz
output :
- 29Vdc extra low voltage
- 640mA, resistant to shortcircuits - 128 Tebis products
7
1
TS110
supply :
- 230Vac 50Hz
output :
- 29Vdc extra low voltage
- 320mA, resistant to shortcircuits - 64 Tebis products
4
1
TS111
100m long
1
TG018
500m long
1
TG019
2 plug-in terminals for 4
connections.
1
TG008
1
TG050
Functions :
- sets the relationships between
the input and output devices
- displays the relations and the
type of control offered
TS100
Supply Functions :
- generates the 29V system
supply voltage
- opens circuit in case of shortcircuit or overload
TS110
Twisted pair bus cable EIB-Y (ST) Y x 2 x 2 x 0.8mm
(test voltage 4kV)
TS111
For wiring of the control cabling.
Connectors for twisted pair
termination (pack = 50 pieces)
Connection capacity : 0.6 to
0.8mm single-core wire.
TG008
Wind strength set functions :
- enables protection of shutters
and canopies against high
winds
- consists of an anemometer
and electronic control unit.
TG050
supply :
- 230Vac 50Hz
detection level :
- adjustable from 5 to 55km/h
(factory-adjusted at 25km/h)
Note: used in conjunction with a Tebis TS310 input device
167
Tebis TS - description of the system
Tebis TS is a new installation system providing enhanced
functionality for controlling lighting, shutters and heating.
The method of wiring a Tebis TS installation is always identical,
independent of the functions needed, which reduces the time for
planning and installation.
Thus, with Tebis TS, any push button can deliver any command (on,
off, up/down variation, as an individual, group, master or scenario
command) to any installation load.
These new possibilities simplify life for current and future occupants
by freeing them from certain tasks while guaranteeing that the
electrical installation has a high level of adaptation and development
potential.
Tebis TS offers simple solutions for complex and changing needs.
The more demanding the user, the more evident the benefits. In a
traditional installation, the functions are fixed once the cabling is
finished. In the simplest installations, loads are directly connected to
the control devices. As the users become more demanding, their
needs change. Central or grouped controls are required, cabling and
labour increase rapidly.
How is a Tebis TS installation structured?
N Ph
supply
L
N
distribution board
230 V ~
TS 110
PB PB
1 2
230 V
50/60 Hz
L N
I > I max
ON
4
inputs
1 3
BUS 29 V
reset
PB PB
3 4
11 13
1
reset
3
17 19
2
4
6T0090 a
29 V
12 14
18 20
Bus EIB 29 V ...
TS 320
1 3
1
3
11
TS 100
13
15
17
19
auto
11 13 15 17 19
1
2
3
4
reset
12 14 16 18 20
prog.
0...9...
1
2
1
2
1
2
3
4
3
4
5
6
7
8
A
B
C
CL
TS 350
OK
+
1 3
11 13
1
3
configurator
(programmer)
Entry products are attached to control units.
12 14
System products provide the 29V
bus supply and allow the
installation to be configured.
Input products
Register the information coming from the control units (push button,
switch, timer, etc). These orders are then carried via the bus cable to
the output modules.
17 19
2
4
18 20
Output products supply power to
the loads.
Electrical connection
N Ph
Output products
Interpret the information transmitted by the input products, convert
them into action and power the connected loads. The output
products are divided into three large families: lighting, shutters/blinds
and heating.
System products
They are of two types:
-
The power supply supplies the 29 V dc to power the bus.
E1
-
The configurator connects the input and output modules.
In other words, it enables the operation of the installation.
E3
7 9
13 15
S1
S2
E2
E4
Operating principle
The Tebis TS installation differs from the traditional installation in that
it separates control and power.
The power circuit comprises the protection and the power supply to
the electrical loads by means of the output modules. The control
circuit (bus) joins all the input products and sends orders to the
appropriate output contacts.
4 output S3
module
4 input
module
8 10
S4
14 16
Bus 2 wire 29 V
TBTS
The control circuit (bus) joins all the input modules together to which
the control units and the output modules are attached. After wiring,
simply program the installation according to the desired operation.
249
Tebis TS - how the system works
The Tebis TS system
movement
detector
luminous buttons
or switches
240 V
240V contact
inputs
PB
twilight
switch
wind gauge
240 V
PB
240 V AC
window and
door contacts
240 VM
lighting
outputs
TS 316
2
inputs
.....
TS 302
standard
buttons
and switches
240V input timer switch
module
PBPB
4
inputs
TS 304
TS 210
N
L
temperature
regulator
dimmed
outputs
bus supply module
PB PB
.....
230 V M
TS 110
TS 320
230 V
50/60 Hz
L N
I > I max
ON
TS 320
BUS 29 V
movable shutter
outputs
reset
reset
6T0090 a
thermostat
20
25
10
5
15
2
INPUTS
30
°C
29 V
1
3
11
TS 100
13
15
17
heating
outputs
19
TS 244
auto
reset
radio remote
control
.....
29 V DC
.....
prog.
0...9...
TS 350
CL
1
2
3
4
TS 350
TU 204
OK
controlled load
+
outputs
inputs
configurator module
Configuration principle
Configuration is concerned with associating each input with the
outputs which are to be controlled as well as with the type of control.
In other words, specifying the required action (on/off command,
dimmer, up/down, etc.).
The choice of "type of control" is carried out directly on the
configurator matrix. Using easily understandable symbols, the
electrician can choose the essential functions in the three fields of
application.
Whatever the functions may be, which are to be carried out, the
configuration principle remains identical and is based on the creation
of configuration links.
A configuration link connects an input to "n" outputs ( n >1) by
carrying a "type of control".
Operation principle
Configuration
Is carried out at the end of the construction with the help of the TS
100 configurator. The TS 100 module is the only necessary
programming tool required to carry out all the logical links which
define the function of the installation.
The configuration takes place in 3 successive stages.
The mode selector of the configurator allows the passage from one
stage to the other.
Creation of a configuration link
prog.
0...9...
- auto
downloading
-
established links
- prog.
programming of the links
lighting
shutters
CL
heating
OK
+
selection keys for “type of
command”
1 link =
selection of
an input no.
+ selection of + selection of a
control type
outputs
+ OK
ok
1/10 V
auto
OK
prog.
STOP
-
+
The inputs and the types of control are selected on the configurator.
The outputs are designated by the keys of the modules concerned.
- 0… 9… numbering of the inputs
1. Numbering of the inputs
This operation gives a unique number to identify each input
connected to the installation. Done by simply closing the input
contacts once whilst in numbering mode
2. Programming the links
This involves creating all the configuration links (see the principle).
250
auto
prog.
0...9...
0...9...
The steps
auto
TS 100
3. Downloading of the program
When the selector is moved to Auto mode, the programming data is
transferred to the different input and output products in the
installation.
After downloading, the installation is operational. All the information
is decentralised to each product. Each module is autonomous. The
configurator simply facilitates subsequent program changes.
Tebis TS - system description
Tebis TS has been further enriched with version 8.2. The following
functions are now available on any outputs:
- Priority commands (override), represented by the symbol “P” on
the display
- Adjustable delay times from 1 sec to 12 hr represented by the
symbol “t” on the display
-
Dimming scenarios allow preset lighting levels to be called upon
at the push of a button (dimmed loads only). Symbol “S”
The new functions are available on the configurator's display. Press
the desired control function (
, ) button for more than 3 seconds
and the new functions appear.
Applications, functions and product offers
applications
lighting
control units
functions
input products
output products
on, off, on/off, dimming
delay time on or off
scenario
TS 302 - TS 304 - TS 310
TS 340 - TS 350 - TS 314
TS316
TS 200 - TS 204 - TS 206
(ON/OFF control)
TS 210 - TS 211 (dimmers)
TS 204A - TS 204C
TS 206A - TS 206B
TS 206C - TS206D
TS 302 - TS 304 - TS 310
TS 340 - TS 350 - TG050
TS 223
(shutters and canopy
blinds)
TS 224
(blinds with adjustable
slats)
TS
TS
TS
TS
TS 240 - TS 244
on, off
priority on/off
shutters &
blinds
up, down, stop
delay time down
up/down
priority up/down
wind safety
heating
comfort, minimum
delay time comfort or minimum
comfort/min, non-freeze
stop, priority, comfort, min
The above functions can be integrated into the individual, group,
master or scenario controls:
- The individual (local) control corresponds to : one or more inputs
controlling a single output
- The group (zone) control corresponds to : one or more inputs
controlling a group of outputs
-
302
340
303
321
-
TS
TS
TS
TS
304 - TS 310
350
320
322 - TS 330
The master control corresponds to : one or more inputs
controlling all the outputs
The scenario function: this is a multi-action command which can
act simultaneously on lighting, shutters and heating .
Tebis TS : Overview of the types of control
- lighting and small power
symbol on TS 100
type of control
input connected to
ON
A press of the button or closing of the contact always switches the
assigned outputs ON
Push Buttons
Switch contact (switch clock, twilight
switch...)
OFF
A press of the button or closing of the contact always switches the
assigned outputs OFF
Push Buttons
Switch contact (switch clock, twilight
switch...)
ON/OFF
Closing of the contact switches the assigned outputs ON. Opening
of the contact switches the assigned outputs OFF
Switch contacts
(switch clock, twilight switch...)
ON/OFF (remote switch control)
Push buttons
Each press of button changes the assigned output status ON/OFF ,
(tactile switches, remote controls...)
Assigned output is ON with one press of the button,OFF with next etc
+
+
Dimming
A short press of the push button switches ON/OFF. A long press of
the button dims BRIGHTER/DARKER
Priority ON
Closing the contact switches the assigned outputs ON (remain ON
whilst switch is closed). Opening contact assigns: OFF with inversion
mode, remains ON if the hold mode is selected
Priority OFF
Closing the contact switches assigned outputs OFF (remain OFF
whilst switch is closed). Opening contact assigns: ON with inversion
mode, remains OFF if the hold mode is selected
Push buttons
(tactile switches, remote controls...)
Switch contacts
(switch clock, twilight switch...)
Switch contacts
(switch clock, twilight switch...)
+
Timer ON
Push buttons
A pressed button or closed contact always switches assigned output Switch contact (switch clock, twilight
ON for time delay (1s to 12h) outputs switch OFF at end of time delay switch...)
+
Timer OFF
Push buttons
A pressed button or closed contact always switches assigned output Switch contact (switch clock, twilight
OFF during time delay (1s to 12h) outputs switch ON at end of delay switch...)
+
ambients
Press button or closed contacts restores preset levels on the
assigned dimming outputs. Three different levels can be memorised
Push Buttons
switch contact (switch clock, twilight
switch...)
251
Tebis TS - installation notes
Tebis TS : Overview of the types of control - Venetian blind or roller-shutter control
symbols on TS 100
type of control
input connected to
UP
A longer press of the push button or closing contact commands UP. Continues
to the upper stop position until stopped. Short press stops movement. After
stopping every short press adjusts the blade angle.
Push Button
Switch control (switch clock, twilight
switch, wind sensor...)
DOWN
Push Button
A longer press of the push button or closing contact commands DOWN.
Switch control (switch clock, twilight
Continues to the lower stop position until stopped. Short press stops movement. switch, wind sensor...)
After stopping every short press adjusts the blade angle.
UP/DOWN
Switch contacts
Closing contact commands DOWN (close). Open contact commands UP (open). (switch clock, twilight switch...)
Command will continue to stop position. Stopping movement is only possible
through separate push buttons controlling UP or DOWN.
Wind Safety*
Closing of the anemometer’s contact commands UP to the upper stop
position (security position). All controls are ignored until anemometer’s
contact opens
Priority UP
Closing contacts commands UP. Remains UP whilst switch is closed.
Opening contacts commands: DOWN in inversion mode, remains UP if hold
mode is selected
Wind strength set TG 050
Switch
+
Priority DOWN
Switch
Closing contacts commands DOWN. Remains DOWN whilst switch is
closed. Opening contacts commands: UP in inversion mode, remains DOWN
if hold mode is selected
+
Timer
Press button or close contact commands UP to upper stop position. Preset
time delay commands DOWN to stop position
Switch
Tebis TS : Overview of the types of control - individual room temperature regulation
symbols on TS 100
type of control
input connected to
Day temperature
Switch contacts
A press of the button or closing of the contact activates the day temperature (switch clock, buttons)
Drop temperature
Switch contacts
A press of the button or closing of the contact activates the drop temperature (switch clock, buttons)
Day/Drop*
Temperature regulator: Short press of button for day/drop. Switch contact:
closing contact activates day temperature, opening contact activates drop
temperature
Temperature regulator
Switch contact (switch clock..)
Frost protection*
Temperature regulator
Temperature regulator: Long press for frost protection. Next press returns to Switch contact (window contact,
currently applicable state. Switch contact: closing contact activates frost
switch clock...)
protection. Opening contact returns to currently selected state
STOP*
Closing contact stops the heating, opening the contact re-activates the
currently selected day, drop or frost protection temperature.
This function has priority over the day, drop or frost protection temperature.
Switch contacts
(switch clock, twilight switch...)
Priority Day Temperature
Closing contact activates day temperature and remains while switch is
closed. Opening contact: changes to drop if inversion mode is selected,
remains to day temperature if hold mode is selected
Switch contacts
(switch clock, twilight switch..)
Priority Drop Temperature
Closing contact activates drop temperature and remains while switch is
closed. Opening contact: changes to day if inversion mode is selected,
remains to drop temperature if hold mode is selected
Switch contacts
(switch clock, twilight switch..)
+
Timer Day Temperature
Press button or close contacts activates the day temperature during a time
delay 1s to 12h. After time delay drop temperature is activated
Push Button
Switch contact (switch clock, twilight
switch..)
+
Timer Drop Temperature
Press button or close contacts activates the drop temperature during a time
delay 1s to 12h. After time delay day temperature is activated
Push Button
Switch contact (switch clock, twilight
switch..)
STOP
+
+
252
* The configuration unit TS100 only allows one relationship with those type of control
Tebis TS - the scenario function
The scenario function
The scenario function is a multi-action, multi-application command.
It enables up to 13 different commands to be associated with any
input in the system.
Example: in the evening it is dark and you are leaving your home. By
pressing the PB at the front door, the garage door and/or the radio
remote control, with one gesture you will be able to:
between 2 and 13 different commands
Any input in the system
can transmit
PB PB
1 2
PB PB
3 4
- Turn on the exterior lights on a timer
- Turn off all the lights in the house
- Turn on a controlled socket outlet to simulate your presence (radio
and light)
- Lower all the shutters
- Switch all the heating to the minimum mode
function scenario
1 3
11 13
1
4
input
3
12 14
types of commands available
- group turning out of lights first floor
- time delay OFF "x" circuit
17 19
2
4
- lighting ground floor
- time delay ON "y" circuit
18 20
TS 200
TS 304
9
1 3
11 13 15 17 19
1
10
3
2
- scenario level 1 group 1
- scenario level 2 group 2
- scenario level 3 group 3
3
12 14 16 18 20
2
1
TS 211
1
3
2
TS 350
4
1 3
- lowering shutters first floor
11 13 15 17 19
1
2
3
4
1
- raising shutters ground floor
3
5
12 14 16 18 20
2
A
B
C
7
4
6
8
TS 220
Bus
1 3
11 13
1
3
12 14
- comfort zone 1
- comfort restart 4 hours zone 2
17 19
2
4
- minimum zone 3
- minimum restart 8 hours zone 4
18 20
TS 240
Advantages and application situations
The scenario function frees the user from small daily constraints
each time s/he is obliged to carry out multiple and repetitive tasks.
This is particularly the case for all small businesses. In the morning
and evening it is necessary to operate the metal shutters, the lighting
for the shop, the shop window, the storeroom and the shop sign, the
power supply for the cash register, video cameras, etc.
These successive operations can be replaced by a single command,
thus eliminating any oversights.
In a Tebis TS installation, the scenario function can be allocated to
any one of the system's inputs, including remote control. It enables
the number of control points to be reduced and simplifies repetitive
procedures; this increases the level of comfort for the user.
The diversity of activities in the service sector enables each user to
imagine situations in his professional environment where he is called
on to start up different technical equipment once or several times a
day.
Examples in multi-purpose rooms: 1 PB per practical activity,
occupancy scenario (non-occupancy of hotel room), projection
scenario in a meeting room or classroom.
Configuration
20 scenario functions are available per installation. The scenario
functions exploit the "types of controls" corresponding to the first
two columns in the configurator's matrix.
To program a scenario, you only need to ok the first configuration
link by holding down the OK key > 2 secs. In these conditions the
input number does not increment; this enables the association of
several links to the one input. The final link of the scenario is
recorded by pressing the key normally.
"Leaving" scenario
1 3
11 13
2
3
4
12 14
TS 302 / TS 304
1 3
PB
BP
17 19
1
.....
turning out all the lights
18 20
11 13 15 17 19
1
2
3
4
.....
lowering all the shutters
12 14 16 18 20
1 3
13 15 17
1
2
3
4
.....
heating switches moved to
minimum mode
14 16 18
253
Tebis TS - technical data
Tebis TS : technical data
Maximum number of products per installation
- 64 products with a TS111 power supply
- up to 128 products with a TS110 power supply
Max. 300 input numbers
Total bus width : 1000m max.
Max. distance between the power supply and the TS products:
350m.
TS100 TS204 TS204
Bus power supply
TS304
TS204
TS110
350 m
TS304
TS204
The EIB Y (ST) Y 2 x 2 x 0.8 (ref. TG 018, TG019) bus cable can be
laid within immediate proximity of the low voltage network. However,
you are advised to make provision for wall boxes which are separate
or fitted with separating partitions for the bus cable connections and
the LV cable connections. The EIB cable is insulated to 4 kV.
(NFC 3209)
Transmission technique
EIB bifilary technique, metal-clad twisted pair.
Command information modulated symmetrically, superimposed on
the system voltage of 29 V - (VLV), transmission of serial asynchronic
data (time-division multiplex), CSMA/ CA access process,
transmission speed 9600 BPS.
350 m
700 m
Recommendations for implementing a TS installation
1. Install the TS products in the base of the cabinet to avoid an
excessively high operating temperature.
2. Connect all the input/output products to the 29 V bus.
3. Connect the electrical cables to the different outputs in the output
modules.
4. Follow the configuration instructions for the system.
254
Structure of the bus wiring
It can be star-shaped, linear, tree or ring-shaped.
Immunity to interference in accordance with IEC and EIBA standards.
Joints in the bus cable
Where joints in the bus cable are required, we recommend (in order
to minimise any conductor damage) the use of the EIB screwless
terminal TG008 within a suitable junction box.
Tebis TS - Radio remote control
Technical characteristics
Remote control TU 202
- Transmission frequency: 433 MHz
- Transmission security: open - ended / encoding and
encryption
- Keys: 2 keys - numbered 1 and 2
- Range in a free field: 50m
- Power supply: 3V CR 1620 lithium cell power
- Degree of protection: IP30
- Operating temperature: -20°c to +70°C
- Storage temperature: -20°C to +70°C
- Dimensions: 61 x 29 x 16
- Weight :25 9
- Key ring chain
- Comply with EN 300 220-1
- LED to indicate radio transmission
LED to indicate radio transmission
1
2
Remote control TU 204
- Transmission frequency :433 MHz
- Transmission security: open - ended / encoding and
encryption
- Keys: 4 keys - numbered 1 to 4
- Range in a free field: 100m
- Power supply: 3V CR 1620 lithium cell power
- Degree of protection: IP30
- Operating temperature: -20°c to +70°C
- Storage temperature: -20°C to +70°C
- Dimensions: 111 x 51 x 18
- Weight: 60 9
- Supplied with wall-mounting bracket
- Comply with EN 300 220-1
- LED to indicate radio transmission
LED to indicate radio transmission
Remote control TU 209
- Transmission frequency :433 MHz
- Transmission security: open - ended / encoding and
encryption
- Keys: 8 keys - numbered 1 to 8
1 group selection key
- Range in a free field: 100m
- Power supply: 3V CR 1620 lithium cell power
- Degree of protection: IP30
- Operating temperature: -20°c to +70°C
- Storage temperature: -20°C to +70°C
- Dimensions: 111 x 51 x 18
- Weight: 70 9
- Supplied with wall-mounting bracket
- Comply with EN 300 220-1
- LED to indicate radio transmission
2
3
4
1
2
3
4
5
6
7
8
A
B
C
LEDs to indicate radio transmission
and to visualise the group
TS 350
2
Bus
2
1
3
2
20
4
4
TU
1
3
2
7
20
4
9
5
6
A
B
8
C
TU
TU
20
1
Remote control TS 350
- Transmission frequency: 433 MHz
- Transmission security: open - ended / encoding and
encryption
- Keys: 4 keys - numbered 1 to 4
- Degree of protection: IP54
- Operating temperature: 0°c to +70°C
- Storage temperature: -20°C to +70°C
- Dimensions: 130 x 80 x 35
- Dimension of antenna: 110mm
- Comply with EN 300 220-1
- LED to indicate radio transmission
- wall mounted with 4 screws
1
255
Tebis TS - input devices
The TS303 is an input device with 2 inputs with period transmitting.
The status of the inputs are transmitted automatically every
15 minutes as well as after each change of status of one of the
inputs.
The product dedicated to heating is particularly suited to
manage traditional automation products like thermostats, programmable thermostats regulations. During configuration, it can only be
connected to the outputs of the TS240 device.
Up to 4 conventional push buttons or switches or other voltage free
contacts can be connected with the push button input TS304
TS 302
599302 1
E1
E2
+
-
}
Test / adressing
button
indication of
function
red
Function
Up to 2 conventional push buttons or switches or other voltage free
contacts can be connected with the push button input TS302.
Layout TS302
- +
System
voltage
29 V DC (SELV)
Bus presence test
conventional
push-button or switch
(the black/white connection
wires have the same
reference potential)
yellow
Input modules TS302 / TS303 /TS304
These devices are fitted into a flush box - e.g. behind a connected
switch.
Operation characteristics
- min. closing time: 50ms
- length of cable extendible up to 5m by twisted pair wire
Dimensions
size; 38 x 35 x 12mm
E2
+
-
}
Test / adressing
button
indication of
function
- +
System
voltage
29 V DC (SELV)
(the black/white connection
t° wires have the same
reference potential)
Note: for the connection of one push button,
isolate all unused wires
Layout TS304
TS 304
599304 1
-
E1
E2
E3
E4
}
+
- +
System
Test / adressing
button
indication of
function
bleu
voltage
29 V DC (SELV)
Bus presence test
conventional
push-button or switch
(the black/white connection
wires have the same
reference potential)
Note: for the connection of one push button,
isolate all unused wires
256
Bus presence test
conventional
push-button or switch
vert
Electrical characteristics
- supply voltage: 230V~ 50Hz system voltage 29V
- connectable type of contacts: push-buttons and switches
- inquiry voltage 5V is generated by the device
- contact current: 0.5mA
E1
red
Connection
- connection to the Bus by red/black plugable TG008 terminal
- connection of the inputs by plugable connector, the connecting
- cable connector / device is supplied with the product.
It includes:
- the plugable connector
- csa conductor 0.22mm2 - length: 200mm
TS 303
599303 1
red
Environment
- working temperature: 0 to +45ºC
- storage temperature: -20 to +70ºC
- ingress protection IP: IP 20
Layout TS303
yellow
Technical specifications
Voltage
Supply
product supply via the EIB Bus
Note: for the connection of one push button,
isolate all unused wires
yellow
These devices transfer the operation information and control the
allocated outputs over the bus system.
Tebis TS - input devices
6 inputs module TS 310
Function
The input device TS 310 provides 6 inputs for 230V AC for the
connection with time lag switches, air speed indicator, light sensitive
switches or other 230V contacts.
Electrical connection
System voltage:
Bus 29 V and 230 V~ /50 Hz
selection switch:
up : normal function
or programming
down : manual
handling with
push-buttons
Characteristics of an entry
- Un: 230V~ - 15% 50/ 60Hz (open contact ), entries can be
connected on different phases,
- In: 1 mA (closed contact)
- levels for entries E1 to E3:
0...30V~ = 0 80 ... 230 V~ = 1
- levels for entries E4 to E6 and for the detection entry:
a0 ... 130 V~ = 0
80 ... 230 V~ = 1
- maximum length between probe and entry: 100 m
( connection of push-buttons on the entries E4, E5, E6:
up to 10 push buttons with indication light in parallel
( 1 mA per neon lamp ).
Ambient temperature controller TS 320, TS 321 et TS 322
Function In association 4 output modules TS 240, these controllers
regulate the heating of either electric heaters or hot water radiators
equipped with electro-thermal actuators mounted directly on the
radiator or on the hot water boilers.
The TS 240 and the controllers communicate with one another via
the bus 29V.
The controllers must be chosen according to the heater types. The
selection of the settings comfort ECO
or frost protection can be done either remotely over the bus or
locally by push-buttons on the controllers
- soft press: switching from comfort to ECO or vice versa - hard
press (2 sec.): switching to frost protection (reset by soft press). The
push-button on the front allows numbering the controller while
programming with configurator TS 100;
Supply voltage:
Bus 29 V
Functional characteristics
Pl regulation with integral time action
Time basis:
- TS 320: 20 min
- TS 321: 10 min
- TS 322: 5 min set values:
21ºC ± 4ºC
- ECO: comfort -4ºC
- frost protection: 7ºC
adjusting range of the potentiometer: 0ºC to ± 45ºC
regulation class: Class B
input 3
input 2
input 1
1 2
11
15
19
auto
2
4
5
6
16
input 5
System
voltage
29 V DC (SELV) further bus
connection
operating push button:
a) programming
b) monual operation
3
12
indication of switch
state
20
input 6
1
input 4
Connection
- connection to the Bus via the TG 008 plugable terminal
- connection of the 230V supply contacts on the entries by cage
terminals
- cage terminals:
flexible: 1mm2 to 6mm2
rigid:
1,5mm2 to 10mm2
watched
phase
illuminated
push button
Note: the inputs can be connected to different phases. In case of
power failure:
the entries connected on the same phase as the supply
phase of the device will not be affected by the power failure
(no unwished instructions are sent). The initial status of the
entries are systematically resent after the power failure.
Product presentation
81
2
= comfort
= ECO
3
81
Environment
- Working temperature: 0ºC to +45ºC
- Storage temperature: -20ºC to +70ºC
- Ingress of protection IP: IP 40
Ph
N
= Anti-frost
1
➀ selection push-button
➁ potentiometer ±4°C
➂ actual setting
Electrical connection
seal the sheath
connection
flush mounting box: ø 60mm;
fixing by screws
comfort :
s
tebi
60
er
hag
Environment
- Ingress of protection IP: IP 302
- Working temperature: 0°C to + 45 °C
- Storage temperature: -20°C to +70 °C
257
Tebis TS - outside temperature
transmitting kit
Outside temperature transmitting kit TS 330
Function
The TS 330 kit measures the outside temperature and sends it to the
ambient temperature controllers ( TS 320, TS 321, TS 322 ) to limit
the energy consumption. This product, preseted in the factory,
transmits automatically the outside temperature to all the controllers
of the installation. They integrate the energy limiting
function based on the settings indicated on the curve below.
Connection
BUS 29 V
009
TG
09
5870
330
TS
4
30
5993
Contents of the kit:
- 1 temperature transmitter + probe
- 1 TG 009 connector
- 1 printed circuit for DIN rail + adaptor + blanking clip
6
4
8
Technical specifications:
- supply voltage: Bus 29V
- max. distance to the probe: 50m
- withstanding of the probe at 25°C: 10 kΩ
- measure transmission periodicity: 15 min.
- measure: - 30°C to + 50°C
operating rate
Environment:
- Working temperature: -5 °C to +45 °C,
- Storage temperature: -20 °C to +70 °C,
- ingress protection of the probe: IP65
Connection:
- of the probe: cage terminal with flexible of rigid cable max. 1,5mm2
- of the Bus: on printed circuit in the bottom of the rail + TG 009
connector
100 %
50 %
outside
temperature
0%
set T˚
-27 C
set T˚
-13.5 C
activ
set T˚
Tebis TS:
output devices for lighting
Display unit TS 400
Electrical characteristics:
Supply voltage: Bus 29V
connection
flush mounting box: ø 60mm;
fixing by screws
Functional characteristics:
- display by 4 red LED’s ø 3 mm,
- setting by 4 CMS push-buttons under the cover
s
tebi
er
hag
60
Environment:
- Working temperature: -5°C to + 45ºC
- Storage temperature: -25ºC to +75ºC.
Display of the outputs
When installed this device allows to check from a distance the
switching ON or OFF of the 4 lighting circuits ( status ON or OFF ) by
4 LED’s.
The TS 400 setting is similar to the setting of the output device TS
204. The LED’s are selected via the push buttons located beneath
the removable cover when setting the links.
To visualise the status of an output, the LED must be included in all
the links concerned by this output.
258
push-button for programming
81
Display of an input
The TS 400 also allows to display on an output LED the status of
one entry of the system.
A simple link between the concerned input and output of the TS 400
has to be made by using the “ switch “ command (3rd column of the
configurator’s matrix ).
81
visual indicator
Tebis TS - output devices for lighting
Output devices for lighting TS 204 or TS 206
Function
The output devices TS 204 or TS 206 allow:
- “ ON “ / “ OFF “ switching
- temporary “ ON “ or “ OFF “ from 1 second to 12 hours
- “ ON “ or “ OFF “ overrides
These devices are controlled over the system line by allocated bus
inputs. They also provide a manual override facility and a visual indicator ON/ OFF
Technical characteristics
References
TS 204A
TS 204C
TS 206A
TS 206B
TS 206C
Number of output contacts
4 voltage free 4 voltage free 6 voltage free 6 voltage free 6 voltage free
contacts
contacts
contacts
contacts
contacts
Contact’s loading capacity
and electrical endurance
4A
300000
cycles
10A
250000
cycles
4A
1000000
cycles
6A
20000
cycles
10A
20000
cycles
- incandescent
1000W
100000
cycles
1800W
70000
cycles
600W
30000
cycles
1800W
18000
cycles
1800W
18000
cycles
- halogen
1000W
100000
cycles
1800W
70000
cycles
600W
30000
cycles
1800W
18000
cycles
1800W
18000
cycles
- fluo non compensated
cos + 0.3
-
-
-
-
-
- fluo in parallel
compensated µf
-
-
-
-
-
Supply voltage
29V
29V
29V
29V
29V
Consumption
-
-
-
-
-
Watts loss
<8W
<8W
6W
6W
6W
Working temperature
0 to +45°C
0 to +45°C
0 to +45°C
0 to +45°C
0 to +45°C
Storage temperature
0 to +45°C
0 to +45°C
0 to +45°C
0 to +45°C
0 to +45°C
Dimensions
4
4
4
4
4
Connection: flexible
rigid
1 to 6mm
1.5 to 10mm2
2
1 to 6mm
1.5 to 10mm2
Connection
TS204A and TS204C
Ph
N
2
1 to 6mm
1.5 to 10mm2
2
1 to 6mm
1.5 to 10mm2
2
TS206A, TS206B and TS206C
Ph
N
output 1 output 2
indicaion of
switch state
auto
test /
adressing
button
System
voltage
29 V DC (SELV)
operating push-button for
manual operation
6 8 10 12 14 16
output 3 output 4
output 1 output 2 output 3
1 3 5 7 9 11 13 15
1 3 5 7 9 11 13 15
selection switch
TS 204
Auto / Manu
1 to 6mm2
1.5 to 10mm2
selection switch TS 206
Auto / Manu
auto
test / adressing
button
1
2
3
4
5
6
indication of
switch state
operating push-button for
manual operation
6 8 10 12 14 16
System
voltage
29 V DC (SELV) output 4 output 5 output 6
259
Tebis TS - output devices for lighting
Dimming output devices TS 210 and TS210A direct output,
TS211 3 outputs 1-10V
The TS 210 and TS 211 are piloted via push-buttons connected to
the input devices.
One single push-button can pilot a dimming circuit:
- short pushes will switch “ ON “ and “ OFF “
- long pushes will increase or decrease the lighting level
An “ ON “ order will bring back the luminosity to the initial level.
Technical characteristics
references
TS 210 and TS210A
TS 211
number of outputs
1 direct output protected against overloads
2 outputs (per output : 1 contact TOR+1 - 10V)
contact rating
600 W (see chart below) TS210
300W TS210A
contact TOR 16A AC1 250 V
same characteristics as TS200)
output 1 - 10V : max. current 50mA
supply voltage
Bus + 230V 50Hz
Bus + 230V 50Hz
consumption
0.5VA
5VA
power dissipation
<5W
10 W
working temperature
0 to +45 °C
0 to +45 °C
storage temperature
-20 to + 70 °C
-20 to + 70 °C
dimensions
4
6
connection:
flexible
1 to 6mm2
1 to 6mm2
rigid
1.5 to 10mm2
1.5 to 10mm2
Connection
TS210
TS211 + dimmer
Ph
N
Ph
N
output 1 output 2 output 3
selection switch
Auto / Manu
indication of overload or
overheating:
- switched on for overheating
- flashing for overload or
short-circuit
operating
push-button for
manual operation
1 3
TS 210
auto
load
load type
indication
Adressing
button
14 16
1
3
TS 211
9
11 13 15 17 19
1
2
10
- +
- +
EV101
EV103
cd 3
load
TS 211 + electronic ballast
Ph
N
output 1 output 2 output 3
Working temperature
35 °C
45 °C
mini load
+
System
cd1 cd2
voltage
29 V DC (SELV)
further bus
connection
Push-button load
for configurat
of load type (load select)
Technical characteristics of load contacts TS 210
1
maxi load
incandescent
20 W
600 W
500 W
VL halogen
20 W
600 W
500 W
Hal. VLV +
convention. transfor.
transfo 20VA
Load 15 W
transfo 600VA
load 480 W
transfo 500VA
load 400 W
Hal. VLV + electronic transfo 25VA
transformer
load 20 W
transfo 600VA
load 540 W
transfo 500VA
load 450 W
260
2 4 6 8 10 12
EV 103
Note: before using the TS 210, it has to be configured by specifying
the load to be controlled.
Type of load
3
12 14 16 18 20
-
System
voltage
29 V DC
(SELV)
1 3 5 7 9 11
auto
commut.
Auto /
Manu
3
TS 211
9
L
N
auto
1
10
-
System
voltage
29 V DC (SELV)
11 13 15 17 19
2
3
12 14 16 18 20
+
cd1 cd2
further bus
connection
-+
-+
cd 3
1-10 V
+ -
electronic ballasts
fluorescent tube
indication of switch
state
operating
push-button for manu
operation
Tebis TS - output devices for
blinds and shutters
output for 4 blinds, shutters TS 223, TS 224,
The range of products blinds and shutters covers two applications:
- the unit TS 223 manage the orders rise, coming down, and stop.
They will pilot rolling shutters, blinds.
- the units TS 224 manage the orders rise, coming down, stop as
well as tilting blinds. They will pilot blinds.
In “ Auto “ mode the commands are supplied from the input devices
of the Tebis system (TS304 or TS310).
In the “ Manual “ mode, the commands are supplied locally from the
push-buttons on the front of the device ( override ).
Technical characteristics
References
TS 223, TS 224
number of output
4
contact rating
6 A AC1 250 V ~
electrical endurance
100 000 operations
alimentation
Bus
consumption
<02W
power dissipation
<1W
working temperature
0 to +45 °C
storage temperature
-20 to +70 °C
dimensions
4
Connection:
flexible
rigid
1 to6mm2
1.5 to 10mm2
Connection
TS223 / TS224
Ph
N
selection
switch
Auto/Manu
1 3 5 7 9 11 13 15
1
2
3
4
load type indication
adressing
button
System
voltage
29 V DC (SELV)
6 8 10 12 14 16
indication of
switch state
operating push-button for
a) programming
b) manual operation
- 1 push :down
- 2 push :stop
- 3 push :up
- 4 push :stop
- 5 push : down
261
Tebis TS - output devices for heating
Output device for heating TS 244
Connections
The output device TS 244 will carry out the “ ON “, “ OFF “
instructions given by:
- the temperature controllers TS 320, TS 321 or TS 322
- traditional temperature controllers connected to the periodical
pulsed entry module TS 303
Bus
L
The “ Manu “ mode allows the override of the different outputs.
After 1 hour, in case of defect or absence of controllers, the TS 240
will ensure a no frost protection ( 1 minute “ ON “ - 4 minutes
“ OFF “ ). The indication light of the output related to this protection
is flashing.
Bus
7
TS 244
number of output contacts
4 voltage free contacts
contact rating
16 A AC1 250 V
electrical endurance
20 000 operations
supply voltage
29V
consumption
5 VA
power dissipation
<8 W
working temperature
0 °C to +45 °C
storage temperature
-20 °C to f70 °C
dimensions
4 mod
connection: flexible
1 to 6mm2
1,5 to 10mm2
13 15
auto
1
2
3
4
8 10
reference
262
9
TS 244
Technical characteristics
rigid
L
System
voltage
29 V DC (SELV)
L
14 16
L
Bus
Bus
Tebis TS - system devices
Configuration unit TS 100
The configuration unit TS 100 defines the allocation and functions
between the Tebis TS inputs and outputs ( for example TS 304 and
TS 206 ).
Connection
Ph
N
BUS
0...9...
Electrical characteristics:
- supply voltage: 230 V~ 50 Hz, Bus 29 V,
- power consumption: 7 VA,
- power dissipation: 7 W.
Operating data
contact rating indicator output: 1 A 250 V~
Environment:
- working temperature: 0 °C to +45 °C,
- storage temperature: -20 °C to +70 °C.
Connection - flexible : 1 to 6mm2
- rigid : 1.5 to 10mm2
1 3
11 13
reset
1/10 V
STOP
CL
OK
+
System
voltage
29 V DC (SELV)
Power supply units TS 110, TS 111
Function
The power supply units TS 110 and TS 111 generates the system
voltage, which is necessary for the operation of the Tebis TS
devices. The system voltage generated by the TS 110 and TS 111
meets the requirements of the protection measures SELV
(separated extra-low voltage).
TS 111
supply voltage
230 V~ 50 Hz
230V 50 Hz
output voltage
29 V 640 mA
29 V 320 mA
BUS indicator output
clamps 17/19 : the contact is closed
in case of system voltage loss.
To indicate the loss a bell or an
indicator light can be connected
BUS
further bus
connection
Connection TS110, TS111
Ph
N
Ph
N
L N
TS 110
17 19
auto
prog.
0...9...
indicator (ex: ref SU213)
output contact 11/13 : when
programming the inputs, the output
contact is closed with every audible
confirmation of the TS100. A horn or
a bell can be connected here which
can be heard in the whole building.
The indicaor output has no function
in regular service.
Q
L1 N
Q
TS 111
TS 110
230 V
50/60 Hz
230 V 50 Hz
L N
I > I max.
M
OK
Q
M
BUS 29 V
reset
OK
reset
power consumption
24 VA
15 VA
connection:
flexible
rigid
quick connection
1.5mm2
2.5mm2
screw terminals
0.75 to 2.5mm2
0.75 to 4mm2
System
"reset" switch
voltage
29 V DC (SELV)
System
voltage
29 V DC (SELV)
working temperature -5 °C to +45 °C
storage temperature -20 oC to +70 °C
263
Tebis TS - remote telephone interface
TS003
Technical specifications
Electrical characteristics:
- supply voltage :230 V~ +10/-1.S’
50/60 Hz
- consumption: < 4 VA
- output: 3 changeover contact
voltfree contact
max: 5A/250 V~ AC
mini:100mA-12V~.
Presentation
TS 003
Line connection
1
2
Français
Deutsch
English
Italiano
ON OFF
ON OFF
ON OFF
C1
C2
C3
-
6
5
Environment
- Operating temperature 10 °C to +50°C
- Storage temperature: -20 °C to +60°C
Connection
- capacity: flexible :1 to 2.5mm2
rigid:
1 to a 4mm2
Main characteristics
•
•
•
Voice assistance
Fitted with a voice assistance to guide you in your choices and
inform you about the status of the 3 circuits. Choice of 4 languages ( English, French, German, Italian ).
Access code
To limit usage only to the people having the code:
- code set in factory
- easy to personalise
Timed switch-off
Possibility to program each of the circuits to switch-off automatically after 1 to 100 hours.
Manual control
On the main unit press the ON or the OFF button corresponding
to the circuit you want to turn either ON of OFF If the circuit is
programmed for timed switch-off pressing the ON button starts
the timer.
•
Use with a telephone answering machine
The TS 003 can be installed on the same line as an answering
machine, a fax or a modem without disturbances.
•
In case of power failure
Your access code and the circuit programs remain stored in the
memory.
•
Remote control
Can be piloted via any cellular phone(GSM) without using the
TU 001 decoder.
Working principle
Allows you to select your language, takes the line after 6 to 7 rings
when you call your phone. A secret code allows you to limit the
access to the persons of your choice. Provides ON/OFF or timed
switch-off commands for 3 different circuits from any touchtone
telephone to suit your requirements. Will automatically give the line
free once you hang up.
264
4
3
➀ On-line indicator light
➁Circuit operation indicator light
➂ Manual control push buttons
➃ Manual OFF push button
➄ Reset button, back to factory setting code 0000
⑥ Language selection cursor
wiring diagrams
11 12 13 14 15
16
17 18 19 20
TS 003
1
•
Reset
2
3
4
5
6
7
8
9
10
The equipment has been approved in accordance with Council
Decision 98/482/EC for pan-European single terminal connection to
the public switched telephone network (PSTN). However, due to
differences between the individual PSTNs provided in different
countries, the approval does not, of itself, give an un-conditional
assurance of successful operation on every PSTN network
termination point.
In the event of problems, you should contact your equipment
supplier in the first instance.

Documents pareils