Tebis TS - Edmundson Electrical
Transcription
Tebis TS - Edmundson Electrical
modular devices Tebis TS intelligent building system 160 163 164 165 167 Tebis Tebis Tebis Tebis Tebis TS TS TS TS TS - introduction input modules input devices output devices system devices 159 Tebis TS a system for residential & commercial applications Hager has many years experience developing and installing products based on Bus technology. Tebis TS brings the following benefits : ■ integrate within one system services and functions which previously worked independently from each other; B EI EDF ■ make modifications easier ; ■ make the electrical installation more reliable, reducing the chance of electrocution; The command bus transmits information to each of the appliances. ■ tailoring the switch commands to ensure greater user comfort To obtain these benefits means installing two separate circuits, a supply circuit to distribute energy and the control circuit to carry information and instructions. The advantages of the two distinct circuits are many : The supply cabling is simplified The only devices cabled on the LV (240V ac) side are the loads which need power (lights, garage doors...) The controls for these loads (by push switches, thermostats. ) are connected to the bus circuit. Grouping of instructions One order (from a push-button.. ) can control a set of lights or other loads or both at once (a scenario). Flexibility By controlling loads using Tebis TS, the electrical installation can be modified and the use or configuration of the building changed, without touching the LV wiring. Remote Controls Remote control receivers (radio or infrared) can be placed anywhere on the bus. Any load in the installation can then be controlled by remote control When Tebis TS is used. the degree of automation is no longer limited by the complexity of cabling: new benefits can be offered, which were previously impractical... Electrical installation with a command bus ventilation movable shutters, shutters, blinds heating lighting 230/400 V Bus push button switch the power circuit the control bus 160 remote control wind strength temperature Tebis TS is based on simple principles: ■ the input devices react to orders, controls and measures. They act on an ON/OFF order from a switch, measure the variation of ambient temperature or of light level, and transmit orders onto the bus. ■ the output devices receive all information and orders travelling on the bus and execute orders which are addressed to them. ■ the installation Bus is the twisted-pair cable which serves as the information network. Electrical installation with bus technology: A developing concept After proving itself in industrial applications, this installation concept is spreading to include domestic and commercial premises. A concept with accumulating advantages ■ adapts easily to the requirements of current and future occupants ■ gives greater conceptual freedom to the architect ■ easy to install for the electrician Tebis TS uses bus technology for the control of lighting, heating and roller-shutters and other similar loads, in both residential and commercial applications. A small number of products for many applications The Tebis TS system uses only 3 types of products: Input devices, for transmitting to the output devices the orders from push-buttons or information from thermostats or other sensors Bus technology offers benefits that a traditional installation cannot provide. Tebis TS is easy to install. Electrical contractors can continue to use familiar materials and gain precious time in planning, then wiring, as there is only one cable connecting each push button to the next. Right up to - and after - completion of wiring, any switch can be made to control any load : the building user can decide at the last minute. Advanced lighting control Tebis TS enables the creation of ambient lighting as desired. Each push-button controls a set of lights or controls the dimming of lights. The Tebis TS system is particularly suitable for the home and for small commercial premises. Output devices, which control the electrical loads System devices, for setting the relations between inputs and outputs, or for providing the 29V supply Benefits of choosing Tebis TS ■ Flexibility for the user: A single load can be controlled from several positions. Conversely, several loads can be controlled from a single point. ■ Update: The function of each switch can be changed at any time, without touching the wiring Flexibility in shutter control Shutters can be controlled individually, by group or all together. From push-buttons, or even from a wind meter. ■ Larger number of applications: Tebis TS works with any brand of push-buttons and electrical load available ■ Safety : The control wiring voltage is 29V, eliminating the danger of electrocution from the control circuit. Heating at your command From a heating regulator, Tebis TS enables : ■ setting in comfort or economy mode. ■ override of heaters to frost setting ■ override of heaters to ‘off’. Grouped controls (Scenario Switching) In addition to the individual controls each Tebis TS product offers, Tebis TS also allows simultaneous control of several different loads (example : lighting & heating) from one push-button or sensor. 161 Tebis TS examples of residential & commercial switching scenarios Tebis TS: a system which is easy to install ■ All the control units are linked to 2 bus wires via input modules ■ All the electrical loads are linked to the output modules ■ The allocation of links between the push buttons and the loads are carried out by means of an easy to use modular device called a configurator ■ The configurator will make it possible to define, for each input, which outputs are to be commanded and in which way (relay, dimmer, up, down, etc.) After down loading this data to the different products, the installation is functional. Changes or future developments to adapt the installation to the needs of the client are achieved by simply reprogramming. A system easy to configure The configurator defines or modifies the electrical installation Some applications: the "leaving home" scenario. A single gesture is enough to: ■ Turn out all the lights ■ Lower all the shutters ■ Reduce the heating ■ Etc. The scenario, which can be changed at will, can be activated with a push button in the hall, at the garage door or by radio remote control. 1/2. In a sports hall the lighting must be adapted to the activity taking place (tennis, volleyball, basketball, etc.) as well as for the occasion (matches, training, preparation, etc). To assist Specifiers and Installers, Hager run complementary training sessions. Talk to your Hager representative for a current schedule of seminars. 162 1/2. training. matches By assigning a push button to each sport, it is possible to implement the most suitable lighting for the sport being played with a single action, without the need to operate several switches which are each dedicated to a part of the playing area. The "projection" scenario This makes it possible to move straight from a meeting sequence to a projection sequence and vice-versa with a single command. As well as managing the lighting, this command can also drive the motorised screen and supply power to the projector. Benefits that can be sold to the final user: ■ Tebis TS offers the highest level of comfort possible ■ Tebis TS ensures that inevitable future modifications can be handled at least cost are are easy to do ■ Tebis TS offers the most economical control of electricity ■ Using remote controls to simplify your life ■ Adding new push buttons without touching your decor ■ Access all loads from anywhere Tebis TS - input modules Input devices send orders, received from push-buttons or sensors, to the Tebis TS output devices, via the twisted pair cable. for technical details see pages 249-264. Description characteristics No. of inputs pack qty. cat. ref. input device flush-mounted functions : Inputs : - 2 or 4 volt-free contacts 2 1 TS302 4 1 TS304 - enables connection of volt free contacts (example : push-button) - interprets orders and transmits them to the output devices to control lighting, shutters or other electrical loads. - all the connections are for extra low voltage. Supply : - 29V bus (twisted pair) Installation : fits behind standard wall wiring devices (push-button or switch) in a wall box of minimum depth 35mm. An insulated box is recommended TS302 TS304 TS314 Description characteristics size in ❚ 17.5 mm pack qty. cat. ref. input devices, DIN-rail mounted Inputs : - 4 terminals rated at 230Vac 2 1 TS314 functions : - interprets orders at 230Vac and transmits them to the out put devices to control lighting, shutters or other electrical loads. Supply : - 29V bus (twisted pair) 4 1 TS316 the TS314 and TS316 signals the state of the inputs when the 29V twisted pair is switched on. Thus, it is well adapted to controlling automatic devices (timers, telephone remote-control, solar cells, anemometers ...) It can also be connected to push-buttons with indicator lamps. Installation : - DIN-rail Inputs : - 6 terminals rated at 230Vac Supply : - 29V bus (twisted pair) Installation : - DIN-rail Note: TS310 available to satisfy existing installations 163 Tebis TS - input devices description characteristics Thermostat TS322 Used in conjunction with the output device TS244. TS330 TU 202 functions: - local temperature level adjustment. - manual selection of comfort, reduced and frost settings on front face. - remote setting via the bus of comfort, reduced and frost settings. - indication of selected setting by 2 LED’s. Outside temperature transmission kit size in ❚ 17.5 mm pack qty cat. ref. For control of convector heaters or underfloor heating 1 TS320 For control of conventional hot water radiators 1 TS321 For electrical heating by convectors, radiator panel, radiating ceiling, etc... 1 TS322 1 TS330 supply : - 29Vdc Bus maximum of 4 inputs per receiver 1 TS350 supply : - 29Vdc Bus maximum of 12 inputs per receiver 1 TS351 key ring type: - 2 buttons, 2 inputs - with battery - attaches to key ring 1 TU202 4 buttons, 4 inputs - with battery - wall mounting bracket - a label for the function of each button 1 TU204 8 buttons, 3 channels, 24 inputs - with battery - wall mounting bracket - a label for the function of each button 1 TU209 Temperature settings : - comfort : 21OC, adjustable + 4OC - reduced : comfort - 4OC - frost : 7OC Supply : - twisted pair 29V - indication of the setting by 2 LED’s Installation : - surface-mounted, on a flush wall box 60mm dia 50mm deep Supply : - twisted pair 29V 4 Used in conjunction with temperature controllers TS320, TS321 and TS322 this kit enables regulation of heating, depending on the weather. TU 204 front rear radio receiver (RF) - receives orders from TU202, TU204, TU209 and transmits them to the bus. TU 209 front rear remote control (RF) TS 350 TS 351 164 Tebis TS - output devices Enable control of electrical loads, following orders from input devices. There are 3 types of output devices : - for lighting - for small motor loads e.g. shutters, curtains etc. - for heating All output devices are provided with LED indication of the output status and a manual override, on the front face. The outputs can be connected to different phases. description characteristics size in ❚ 17.5 mm pack qty. cat. ref. output devices for, ON/OFF switching outputs : - 4 volt-free contacts 4A AC1 power supply :29Vdc bus 4 1 TS204A outputs : - 4 volt-free contacts 16A AC1 power supply : 29Vdc bus 4 1 TS204C outputs : - 6 volt-free contacts 4A AC1 power supply : 29Vdc bus 4 1 TS206A outputs : - 6 volt-free contacts 10A AC1 power supply : 29Vdc bus 4 1 TS206B outputs : - 6 volt-free contacts 16A AC1 power supply : 29Vdc bus 4 1 TS206C outputs : - 6 volt-free contacts 3 x 16A AC1 + 3 x 6A AC1 power supply : 29Vdc bus 4 1 TS206D outputs : 3, 1-10V outputs designed to drive: - EV102 and EV104 dimmers - transformers and electronic ballasts with 1-10V control (in conjunction with volt free 16A AC1 contact) 6 1 TS211 For control of : - lighting - power outlets - any load controlled by a simple contact TS204C Functions : - on/off switching - on/off override - LED indication of each output state TS206B Output modules for dimmed lighting Function : - ON/OFF switching - dimming - dimming scenarios power supply: - 240Vac 50Hz - 29Vdc Bus TS211 TS 210 for technical details see pages 249-264. For : - 240V incandescent and halogen lamps - ELV halogen lamps with electronic or ferromagnetic transformers outputs: - 1 direct output - 20 - 600W/VA (30oC) 20 - 500W/VA (40oC) 240V/50Hz power supply: - 29Vdc bus 4 1 TS210 For : - 240V incandescent and halogen lamps - ELV halogen lamps with electronic or ferromagnetic transformers outputs: - 1 direct output - 20 - 300W/VA (40oC) 240V/50Hz power supply: - 29Vdc bus 4 1 TS210A 165 Tebis TS - output devices description characteristics size in ❚ 17.5 mm pack qty cat. ref. Output device for 4 movable blinds or canopy blinds outputs : - for 4 motors 240Vac (6A AC1) 4 1 TS223 Functions : - operating and closing by pressing briefly - STOP by pressing briefly - manual override UP/DOWN/STOP - LED indication of each output state - wind safety function supply : - 29Vdc Bus Output modules for 4 slat blinds outputs : - for 4 motors 240Vac (6A AC1) 4 1 TS224 Functions : - opening and closing by pressing for an extended time (400ms) - STOP by pressing briefly - manual override UP/DOWN/STOP - LED indication of each output state - wind safety function supply : - 29Vdc Bus 4 output device, for heating outputs : - 4 volt-free contacts 16A AC1 4 1 TS244 1 TS400 1 TS003 TS223 For control of : - underfloor heating - electric convectors - radiating panels - association with TS320, TS321 and Ts322 thermostats TS400 Functions : - On/OFF control switching - On/OFF override on front face - LED indication of each output state 4 way indicator panel Functions : - reproduces on/off contact status of associated output by LED indication telephone interface unit application: by linking this product to a Tebis input device, you can control specific Tebis system loads remotely from a touch tone telephone TS003 166 supply : - 29Vdc Bus functions: - 3 channel remote control interface with voice guide - restricted access via 4 digit user code - circuit status indicator light - manual override push button - on/off switching - timed off switching (1-100hours) supply : - 29V twisted pair (bus) installation : - surface mounted on a flush wall box = 60mm dia 50mm deep outputs: 3 volt free changeover contacts 5A 250V AC1 supply: 230V ac 50Hz Tebis TS - system devices description characteristics size in ❚ 17.5 mm pack qty cat. ref Control device supply : - 230Vac 50Hz - 29V twisted pair (bus) 6 1 TS100 supply : - 230Vac 50Hz output : - 29Vdc extra low voltage - 640mA, resistant to shortcircuits - 128 Tebis products 7 1 TS110 supply : - 230Vac 50Hz output : - 29Vdc extra low voltage - 320mA, resistant to shortcircuits - 64 Tebis products 4 1 TS111 100m long 1 TG018 500m long 1 TG019 2 plug-in terminals for 4 connections. 1 TG008 1 TG050 Functions : - sets the relationships between the input and output devices - displays the relations and the type of control offered TS100 Supply Functions : - generates the 29V system supply voltage - opens circuit in case of shortcircuit or overload TS110 Twisted pair bus cable EIB-Y (ST) Y x 2 x 2 x 0.8mm (test voltage 4kV) TS111 For wiring of the control cabling. Connectors for twisted pair termination (pack = 50 pieces) Connection capacity : 0.6 to 0.8mm single-core wire. TG008 Wind strength set functions : - enables protection of shutters and canopies against high winds - consists of an anemometer and electronic control unit. TG050 supply : - 230Vac 50Hz detection level : - adjustable from 5 to 55km/h (factory-adjusted at 25km/h) Note: used in conjunction with a Tebis TS310 input device 167 Tebis TS - description of the system Tebis TS is a new installation system providing enhanced functionality for controlling lighting, shutters and heating. The method of wiring a Tebis TS installation is always identical, independent of the functions needed, which reduces the time for planning and installation. Thus, with Tebis TS, any push button can deliver any command (on, off, up/down variation, as an individual, group, master or scenario command) to any installation load. These new possibilities simplify life for current and future occupants by freeing them from certain tasks while guaranteeing that the electrical installation has a high level of adaptation and development potential. Tebis TS offers simple solutions for complex and changing needs. The more demanding the user, the more evident the benefits. In a traditional installation, the functions are fixed once the cabling is finished. In the simplest installations, loads are directly connected to the control devices. As the users become more demanding, their needs change. Central or grouped controls are required, cabling and labour increase rapidly. How is a Tebis TS installation structured? N Ph supply L N distribution board 230 V ~ TS 110 PB PB 1 2 230 V 50/60 Hz L N I > I max ON 4 inputs 1 3 BUS 29 V reset PB PB 3 4 11 13 1 reset 3 17 19 2 4 6T0090 a 29 V 12 14 18 20 Bus EIB 29 V ... TS 320 1 3 1 3 11 TS 100 13 15 17 19 auto 11 13 15 17 19 1 2 3 4 reset 12 14 16 18 20 prog. 0...9... 1 2 1 2 1 2 3 4 3 4 5 6 7 8 A B C CL TS 350 OK + 1 3 11 13 1 3 configurator (programmer) Entry products are attached to control units. 12 14 System products provide the 29V bus supply and allow the installation to be configured. Input products Register the information coming from the control units (push button, switch, timer, etc). These orders are then carried via the bus cable to the output modules. 17 19 2 4 18 20 Output products supply power to the loads. Electrical connection N Ph Output products Interpret the information transmitted by the input products, convert them into action and power the connected loads. The output products are divided into three large families: lighting, shutters/blinds and heating. System products They are of two types: - The power supply supplies the 29 V dc to power the bus. E1 - The configurator connects the input and output modules. In other words, it enables the operation of the installation. E3 7 9 13 15 S1 S2 E2 E4 Operating principle The Tebis TS installation differs from the traditional installation in that it separates control and power. The power circuit comprises the protection and the power supply to the electrical loads by means of the output modules. The control circuit (bus) joins all the input products and sends orders to the appropriate output contacts. 4 output S3 module 4 input module 8 10 S4 14 16 Bus 2 wire 29 V TBTS The control circuit (bus) joins all the input modules together to which the control units and the output modules are attached. After wiring, simply program the installation according to the desired operation. 249 Tebis TS - how the system works The Tebis TS system movement detector luminous buttons or switches 240 V 240V contact inputs PB twilight switch wind gauge 240 V PB 240 V AC window and door contacts 240 VM lighting outputs TS 316 2 inputs ..... TS 302 standard buttons and switches 240V input timer switch module PBPB 4 inputs TS 304 TS 210 N L temperature regulator dimmed outputs bus supply module PB PB ..... 230 V M TS 110 TS 320 230 V 50/60 Hz L N I > I max ON TS 320 BUS 29 V movable shutter outputs reset reset 6T0090 a thermostat 20 25 10 5 15 2 INPUTS 30 °C 29 V 1 3 11 TS 100 13 15 17 heating outputs 19 TS 244 auto reset radio remote control ..... 29 V DC ..... prog. 0...9... TS 350 CL 1 2 3 4 TS 350 TU 204 OK controlled load + outputs inputs configurator module Configuration principle Configuration is concerned with associating each input with the outputs which are to be controlled as well as with the type of control. In other words, specifying the required action (on/off command, dimmer, up/down, etc.). The choice of "type of control" is carried out directly on the configurator matrix. Using easily understandable symbols, the electrician can choose the essential functions in the three fields of application. Whatever the functions may be, which are to be carried out, the configuration principle remains identical and is based on the creation of configuration links. A configuration link connects an input to "n" outputs ( n >1) by carrying a "type of control". Operation principle Configuration Is carried out at the end of the construction with the help of the TS 100 configurator. The TS 100 module is the only necessary programming tool required to carry out all the logical links which define the function of the installation. The configuration takes place in 3 successive stages. The mode selector of the configurator allows the passage from one stage to the other. Creation of a configuration link prog. 0...9... - auto downloading - established links - prog. programming of the links lighting shutters CL heating OK + selection keys for “type of command” 1 link = selection of an input no. + selection of + selection of a control type outputs + OK ok 1/10 V auto OK prog. STOP - + The inputs and the types of control are selected on the configurator. The outputs are designated by the keys of the modules concerned. - 0… 9… numbering of the inputs 1. Numbering of the inputs This operation gives a unique number to identify each input connected to the installation. Done by simply closing the input contacts once whilst in numbering mode 2. Programming the links This involves creating all the configuration links (see the principle). 250 auto prog. 0...9... 0...9... The steps auto TS 100 3. Downloading of the program When the selector is moved to Auto mode, the programming data is transferred to the different input and output products in the installation. After downloading, the installation is operational. All the information is decentralised to each product. Each module is autonomous. The configurator simply facilitates subsequent program changes. Tebis TS - system description Tebis TS has been further enriched with version 8.2. The following functions are now available on any outputs: - Priority commands (override), represented by the symbol “P” on the display - Adjustable delay times from 1 sec to 12 hr represented by the symbol “t” on the display - Dimming scenarios allow preset lighting levels to be called upon at the push of a button (dimmed loads only). Symbol “S” The new functions are available on the configurator's display. Press the desired control function ( , ) button for more than 3 seconds and the new functions appear. Applications, functions and product offers applications lighting control units functions input products output products on, off, on/off, dimming delay time on or off scenario TS 302 - TS 304 - TS 310 TS 340 - TS 350 - TS 314 TS316 TS 200 - TS 204 - TS 206 (ON/OFF control) TS 210 - TS 211 (dimmers) TS 204A - TS 204C TS 206A - TS 206B TS 206C - TS206D TS 302 - TS 304 - TS 310 TS 340 - TS 350 - TG050 TS 223 (shutters and canopy blinds) TS 224 (blinds with adjustable slats) TS TS TS TS TS 240 - TS 244 on, off priority on/off shutters & blinds up, down, stop delay time down up/down priority up/down wind safety heating comfort, minimum delay time comfort or minimum comfort/min, non-freeze stop, priority, comfort, min The above functions can be integrated into the individual, group, master or scenario controls: - The individual (local) control corresponds to : one or more inputs controlling a single output - The group (zone) control corresponds to : one or more inputs controlling a group of outputs - 302 340 303 321 - TS TS TS TS 304 - TS 310 350 320 322 - TS 330 The master control corresponds to : one or more inputs controlling all the outputs The scenario function: this is a multi-action command which can act simultaneously on lighting, shutters and heating . Tebis TS : Overview of the types of control - lighting and small power symbol on TS 100 type of control input connected to ON A press of the button or closing of the contact always switches the assigned outputs ON Push Buttons Switch contact (switch clock, twilight switch...) OFF A press of the button or closing of the contact always switches the assigned outputs OFF Push Buttons Switch contact (switch clock, twilight switch...) ON/OFF Closing of the contact switches the assigned outputs ON. Opening of the contact switches the assigned outputs OFF Switch contacts (switch clock, twilight switch...) ON/OFF (remote switch control) Push buttons Each press of button changes the assigned output status ON/OFF , (tactile switches, remote controls...) Assigned output is ON with one press of the button,OFF with next etc + + Dimming A short press of the push button switches ON/OFF. A long press of the button dims BRIGHTER/DARKER Priority ON Closing the contact switches the assigned outputs ON (remain ON whilst switch is closed). Opening contact assigns: OFF with inversion mode, remains ON if the hold mode is selected Priority OFF Closing the contact switches assigned outputs OFF (remain OFF whilst switch is closed). Opening contact assigns: ON with inversion mode, remains OFF if the hold mode is selected Push buttons (tactile switches, remote controls...) Switch contacts (switch clock, twilight switch...) Switch contacts (switch clock, twilight switch...) + Timer ON Push buttons A pressed button or closed contact always switches assigned output Switch contact (switch clock, twilight ON for time delay (1s to 12h) outputs switch OFF at end of time delay switch...) + Timer OFF Push buttons A pressed button or closed contact always switches assigned output Switch contact (switch clock, twilight OFF during time delay (1s to 12h) outputs switch ON at end of delay switch...) + ambients Press button or closed contacts restores preset levels on the assigned dimming outputs. Three different levels can be memorised Push Buttons switch contact (switch clock, twilight switch...) 251 Tebis TS - installation notes Tebis TS : Overview of the types of control - Venetian blind or roller-shutter control symbols on TS 100 type of control input connected to UP A longer press of the push button or closing contact commands UP. Continues to the upper stop position until stopped. Short press stops movement. After stopping every short press adjusts the blade angle. Push Button Switch control (switch clock, twilight switch, wind sensor...) DOWN Push Button A longer press of the push button or closing contact commands DOWN. Switch control (switch clock, twilight Continues to the lower stop position until stopped. Short press stops movement. switch, wind sensor...) After stopping every short press adjusts the blade angle. UP/DOWN Switch contacts Closing contact commands DOWN (close). Open contact commands UP (open). (switch clock, twilight switch...) Command will continue to stop position. Stopping movement is only possible through separate push buttons controlling UP or DOWN. Wind Safety* Closing of the anemometer’s contact commands UP to the upper stop position (security position). All controls are ignored until anemometer’s contact opens Priority UP Closing contacts commands UP. Remains UP whilst switch is closed. Opening contacts commands: DOWN in inversion mode, remains UP if hold mode is selected Wind strength set TG 050 Switch + Priority DOWN Switch Closing contacts commands DOWN. Remains DOWN whilst switch is closed. Opening contacts commands: UP in inversion mode, remains DOWN if hold mode is selected + Timer Press button or close contact commands UP to upper stop position. Preset time delay commands DOWN to stop position Switch Tebis TS : Overview of the types of control - individual room temperature regulation symbols on TS 100 type of control input connected to Day temperature Switch contacts A press of the button or closing of the contact activates the day temperature (switch clock, buttons) Drop temperature Switch contacts A press of the button or closing of the contact activates the drop temperature (switch clock, buttons) Day/Drop* Temperature regulator: Short press of button for day/drop. Switch contact: closing contact activates day temperature, opening contact activates drop temperature Temperature regulator Switch contact (switch clock..) Frost protection* Temperature regulator Temperature regulator: Long press for frost protection. Next press returns to Switch contact (window contact, currently applicable state. Switch contact: closing contact activates frost switch clock...) protection. Opening contact returns to currently selected state STOP* Closing contact stops the heating, opening the contact re-activates the currently selected day, drop or frost protection temperature. This function has priority over the day, drop or frost protection temperature. Switch contacts (switch clock, twilight switch...) Priority Day Temperature Closing contact activates day temperature and remains while switch is closed. Opening contact: changes to drop if inversion mode is selected, remains to day temperature if hold mode is selected Switch contacts (switch clock, twilight switch..) Priority Drop Temperature Closing contact activates drop temperature and remains while switch is closed. Opening contact: changes to day if inversion mode is selected, remains to drop temperature if hold mode is selected Switch contacts (switch clock, twilight switch..) + Timer Day Temperature Press button or close contacts activates the day temperature during a time delay 1s to 12h. After time delay drop temperature is activated Push Button Switch contact (switch clock, twilight switch..) + Timer Drop Temperature Press button or close contacts activates the drop temperature during a time delay 1s to 12h. After time delay day temperature is activated Push Button Switch contact (switch clock, twilight switch..) STOP + + 252 * The configuration unit TS100 only allows one relationship with those type of control Tebis TS - the scenario function The scenario function The scenario function is a multi-action, multi-application command. It enables up to 13 different commands to be associated with any input in the system. Example: in the evening it is dark and you are leaving your home. By pressing the PB at the front door, the garage door and/or the radio remote control, with one gesture you will be able to: between 2 and 13 different commands Any input in the system can transmit PB PB 1 2 PB PB 3 4 - Turn on the exterior lights on a timer - Turn off all the lights in the house - Turn on a controlled socket outlet to simulate your presence (radio and light) - Lower all the shutters - Switch all the heating to the minimum mode function scenario 1 3 11 13 1 4 input 3 12 14 types of commands available - group turning out of lights first floor - time delay OFF "x" circuit 17 19 2 4 - lighting ground floor - time delay ON "y" circuit 18 20 TS 200 TS 304 9 1 3 11 13 15 17 19 1 10 3 2 - scenario level 1 group 1 - scenario level 2 group 2 - scenario level 3 group 3 3 12 14 16 18 20 2 1 TS 211 1 3 2 TS 350 4 1 3 - lowering shutters first floor 11 13 15 17 19 1 2 3 4 1 - raising shutters ground floor 3 5 12 14 16 18 20 2 A B C 7 4 6 8 TS 220 Bus 1 3 11 13 1 3 12 14 - comfort zone 1 - comfort restart 4 hours zone 2 17 19 2 4 - minimum zone 3 - minimum restart 8 hours zone 4 18 20 TS 240 Advantages and application situations The scenario function frees the user from small daily constraints each time s/he is obliged to carry out multiple and repetitive tasks. This is particularly the case for all small businesses. In the morning and evening it is necessary to operate the metal shutters, the lighting for the shop, the shop window, the storeroom and the shop sign, the power supply for the cash register, video cameras, etc. These successive operations can be replaced by a single command, thus eliminating any oversights. In a Tebis TS installation, the scenario function can be allocated to any one of the system's inputs, including remote control. It enables the number of control points to be reduced and simplifies repetitive procedures; this increases the level of comfort for the user. The diversity of activities in the service sector enables each user to imagine situations in his professional environment where he is called on to start up different technical equipment once or several times a day. Examples in multi-purpose rooms: 1 PB per practical activity, occupancy scenario (non-occupancy of hotel room), projection scenario in a meeting room or classroom. Configuration 20 scenario functions are available per installation. The scenario functions exploit the "types of controls" corresponding to the first two columns in the configurator's matrix. To program a scenario, you only need to ok the first configuration link by holding down the OK key > 2 secs. In these conditions the input number does not increment; this enables the association of several links to the one input. The final link of the scenario is recorded by pressing the key normally. "Leaving" scenario 1 3 11 13 2 3 4 12 14 TS 302 / TS 304 1 3 PB BP 17 19 1 ..... turning out all the lights 18 20 11 13 15 17 19 1 2 3 4 ..... lowering all the shutters 12 14 16 18 20 1 3 13 15 17 1 2 3 4 ..... heating switches moved to minimum mode 14 16 18 253 Tebis TS - technical data Tebis TS : technical data Maximum number of products per installation - 64 products with a TS111 power supply - up to 128 products with a TS110 power supply Max. 300 input numbers Total bus width : 1000m max. Max. distance between the power supply and the TS products: 350m. TS100 TS204 TS204 Bus power supply TS304 TS204 TS110 350 m TS304 TS204 The EIB Y (ST) Y 2 x 2 x 0.8 (ref. TG 018, TG019) bus cable can be laid within immediate proximity of the low voltage network. However, you are advised to make provision for wall boxes which are separate or fitted with separating partitions for the bus cable connections and the LV cable connections. The EIB cable is insulated to 4 kV. (NFC 3209) Transmission technique EIB bifilary technique, metal-clad twisted pair. Command information modulated symmetrically, superimposed on the system voltage of 29 V - (VLV), transmission of serial asynchronic data (time-division multiplex), CSMA/ CA access process, transmission speed 9600 BPS. 350 m 700 m Recommendations for implementing a TS installation 1. Install the TS products in the base of the cabinet to avoid an excessively high operating temperature. 2. Connect all the input/output products to the 29 V bus. 3. Connect the electrical cables to the different outputs in the output modules. 4. Follow the configuration instructions for the system. 254 Structure of the bus wiring It can be star-shaped, linear, tree or ring-shaped. Immunity to interference in accordance with IEC and EIBA standards. Joints in the bus cable Where joints in the bus cable are required, we recommend (in order to minimise any conductor damage) the use of the EIB screwless terminal TG008 within a suitable junction box. Tebis TS - Radio remote control Technical characteristics Remote control TU 202 - Transmission frequency: 433 MHz - Transmission security: open - ended / encoding and encryption - Keys: 2 keys - numbered 1 and 2 - Range in a free field: 50m - Power supply: 3V CR 1620 lithium cell power - Degree of protection: IP30 - Operating temperature: -20°c to +70°C - Storage temperature: -20°C to +70°C - Dimensions: 61 x 29 x 16 - Weight :25 9 - Key ring chain - Comply with EN 300 220-1 - LED to indicate radio transmission LED to indicate radio transmission 1 2 Remote control TU 204 - Transmission frequency :433 MHz - Transmission security: open - ended / encoding and encryption - Keys: 4 keys - numbered 1 to 4 - Range in a free field: 100m - Power supply: 3V CR 1620 lithium cell power - Degree of protection: IP30 - Operating temperature: -20°c to +70°C - Storage temperature: -20°C to +70°C - Dimensions: 111 x 51 x 18 - Weight: 60 9 - Supplied with wall-mounting bracket - Comply with EN 300 220-1 - LED to indicate radio transmission LED to indicate radio transmission Remote control TU 209 - Transmission frequency :433 MHz - Transmission security: open - ended / encoding and encryption - Keys: 8 keys - numbered 1 to 8 1 group selection key - Range in a free field: 100m - Power supply: 3V CR 1620 lithium cell power - Degree of protection: IP30 - Operating temperature: -20°c to +70°C - Storage temperature: -20°C to +70°C - Dimensions: 111 x 51 x 18 - Weight: 70 9 - Supplied with wall-mounting bracket - Comply with EN 300 220-1 - LED to indicate radio transmission 2 3 4 1 2 3 4 5 6 7 8 A B C LEDs to indicate radio transmission and to visualise the group TS 350 2 Bus 2 1 3 2 20 4 4 TU 1 3 2 7 20 4 9 5 6 A B 8 C TU TU 20 1 Remote control TS 350 - Transmission frequency: 433 MHz - Transmission security: open - ended / encoding and encryption - Keys: 4 keys - numbered 1 to 4 - Degree of protection: IP54 - Operating temperature: 0°c to +70°C - Storage temperature: -20°C to +70°C - Dimensions: 130 x 80 x 35 - Dimension of antenna: 110mm - Comply with EN 300 220-1 - LED to indicate radio transmission - wall mounted with 4 screws 1 255 Tebis TS - input devices The TS303 is an input device with 2 inputs with period transmitting. The status of the inputs are transmitted automatically every 15 minutes as well as after each change of status of one of the inputs. The product dedicated to heating is particularly suited to manage traditional automation products like thermostats, programmable thermostats regulations. During configuration, it can only be connected to the outputs of the TS240 device. Up to 4 conventional push buttons or switches or other voltage free contacts can be connected with the push button input TS304 TS 302 599302 1 E1 E2 + - } Test / adressing button indication of function red Function Up to 2 conventional push buttons or switches or other voltage free contacts can be connected with the push button input TS302. Layout TS302 - + System voltage 29 V DC (SELV) Bus presence test conventional push-button or switch (the black/white connection wires have the same reference potential) yellow Input modules TS302 / TS303 /TS304 These devices are fitted into a flush box - e.g. behind a connected switch. Operation characteristics - min. closing time: 50ms - length of cable extendible up to 5m by twisted pair wire Dimensions size; 38 x 35 x 12mm E2 + - } Test / adressing button indication of function - + System voltage 29 V DC (SELV) (the black/white connection t° wires have the same reference potential) Note: for the connection of one push button, isolate all unused wires Layout TS304 TS 304 599304 1 - E1 E2 E3 E4 } + - + System Test / adressing button indication of function bleu voltage 29 V DC (SELV) Bus presence test conventional push-button or switch (the black/white connection wires have the same reference potential) Note: for the connection of one push button, isolate all unused wires 256 Bus presence test conventional push-button or switch vert Electrical characteristics - supply voltage: 230V~ 50Hz system voltage 29V - connectable type of contacts: push-buttons and switches - inquiry voltage 5V is generated by the device - contact current: 0.5mA E1 red Connection - connection to the Bus by red/black plugable TG008 terminal - connection of the inputs by plugable connector, the connecting - cable connector / device is supplied with the product. It includes: - the plugable connector - csa conductor 0.22mm2 - length: 200mm TS 303 599303 1 red Environment - working temperature: 0 to +45ºC - storage temperature: -20 to +70ºC - ingress protection IP: IP 20 Layout TS303 yellow Technical specifications Voltage Supply product supply via the EIB Bus Note: for the connection of one push button, isolate all unused wires yellow These devices transfer the operation information and control the allocated outputs over the bus system. Tebis TS - input devices 6 inputs module TS 310 Function The input device TS 310 provides 6 inputs for 230V AC for the connection with time lag switches, air speed indicator, light sensitive switches or other 230V contacts. Electrical connection System voltage: Bus 29 V and 230 V~ /50 Hz selection switch: up : normal function or programming down : manual handling with push-buttons Characteristics of an entry - Un: 230V~ - 15% 50/ 60Hz (open contact ), entries can be connected on different phases, - In: 1 mA (closed contact) - levels for entries E1 to E3: 0...30V~ = 0 80 ... 230 V~ = 1 - levels for entries E4 to E6 and for the detection entry: a0 ... 130 V~ = 0 80 ... 230 V~ = 1 - maximum length between probe and entry: 100 m ( connection of push-buttons on the entries E4, E5, E6: up to 10 push buttons with indication light in parallel ( 1 mA per neon lamp ). Ambient temperature controller TS 320, TS 321 et TS 322 Function In association 4 output modules TS 240, these controllers regulate the heating of either electric heaters or hot water radiators equipped with electro-thermal actuators mounted directly on the radiator or on the hot water boilers. The TS 240 and the controllers communicate with one another via the bus 29V. The controllers must be chosen according to the heater types. The selection of the settings comfort ECO or frost protection can be done either remotely over the bus or locally by push-buttons on the controllers - soft press: switching from comfort to ECO or vice versa - hard press (2 sec.): switching to frost protection (reset by soft press). The push-button on the front allows numbering the controller while programming with configurator TS 100; Supply voltage: Bus 29 V Functional characteristics Pl regulation with integral time action Time basis: - TS 320: 20 min - TS 321: 10 min - TS 322: 5 min set values: 21ºC ± 4ºC - ECO: comfort -4ºC - frost protection: 7ºC adjusting range of the potentiometer: 0ºC to ± 45ºC regulation class: Class B input 3 input 2 input 1 1 2 11 15 19 auto 2 4 5 6 16 input 5 System voltage 29 V DC (SELV) further bus connection operating push button: a) programming b) monual operation 3 12 indication of switch state 20 input 6 1 input 4 Connection - connection to the Bus via the TG 008 plugable terminal - connection of the 230V supply contacts on the entries by cage terminals - cage terminals: flexible: 1mm2 to 6mm2 rigid: 1,5mm2 to 10mm2 watched phase illuminated push button Note: the inputs can be connected to different phases. In case of power failure: the entries connected on the same phase as the supply phase of the device will not be affected by the power failure (no unwished instructions are sent). The initial status of the entries are systematically resent after the power failure. Product presentation 81 2 = comfort = ECO 3 81 Environment - Working temperature: 0ºC to +45ºC - Storage temperature: -20ºC to +70ºC - Ingress of protection IP: IP 40 Ph N = Anti-frost 1 ➀ selection push-button ➁ potentiometer ±4°C ➂ actual setting Electrical connection seal the sheath connection flush mounting box: ø 60mm; fixing by screws comfort : s tebi 60 er hag Environment - Ingress of protection IP: IP 302 - Working temperature: 0°C to + 45 °C - Storage temperature: -20°C to +70 °C 257 Tebis TS - outside temperature transmitting kit Outside temperature transmitting kit TS 330 Function The TS 330 kit measures the outside temperature and sends it to the ambient temperature controllers ( TS 320, TS 321, TS 322 ) to limit the energy consumption. This product, preseted in the factory, transmits automatically the outside temperature to all the controllers of the installation. They integrate the energy limiting function based on the settings indicated on the curve below. Connection BUS 29 V 009 TG 09 5870 330 TS 4 30 5993 Contents of the kit: - 1 temperature transmitter + probe - 1 TG 009 connector - 1 printed circuit for DIN rail + adaptor + blanking clip 6 4 8 Technical specifications: - supply voltage: Bus 29V - max. distance to the probe: 50m - withstanding of the probe at 25°C: 10 kΩ - measure transmission periodicity: 15 min. - measure: - 30°C to + 50°C operating rate Environment: - Working temperature: -5 °C to +45 °C, - Storage temperature: -20 °C to +70 °C, - ingress protection of the probe: IP65 Connection: - of the probe: cage terminal with flexible of rigid cable max. 1,5mm2 - of the Bus: on printed circuit in the bottom of the rail + TG 009 connector 100 % 50 % outside temperature 0% set T˚ -27 C set T˚ -13.5 C activ set T˚ Tebis TS: output devices for lighting Display unit TS 400 Electrical characteristics: Supply voltage: Bus 29V connection flush mounting box: ø 60mm; fixing by screws Functional characteristics: - display by 4 red LED’s ø 3 mm, - setting by 4 CMS push-buttons under the cover s tebi er hag 60 Environment: - Working temperature: -5°C to + 45ºC - Storage temperature: -25ºC to +75ºC. Display of the outputs When installed this device allows to check from a distance the switching ON or OFF of the 4 lighting circuits ( status ON or OFF ) by 4 LED’s. The TS 400 setting is similar to the setting of the output device TS 204. The LED’s are selected via the push buttons located beneath the removable cover when setting the links. To visualise the status of an output, the LED must be included in all the links concerned by this output. 258 push-button for programming 81 Display of an input The TS 400 also allows to display on an output LED the status of one entry of the system. A simple link between the concerned input and output of the TS 400 has to be made by using the “ switch “ command (3rd column of the configurator’s matrix ). 81 visual indicator Tebis TS - output devices for lighting Output devices for lighting TS 204 or TS 206 Function The output devices TS 204 or TS 206 allow: - “ ON “ / “ OFF “ switching - temporary “ ON “ or “ OFF “ from 1 second to 12 hours - “ ON “ or “ OFF “ overrides These devices are controlled over the system line by allocated bus inputs. They also provide a manual override facility and a visual indicator ON/ OFF Technical characteristics References TS 204A TS 204C TS 206A TS 206B TS 206C Number of output contacts 4 voltage free 4 voltage free 6 voltage free 6 voltage free 6 voltage free contacts contacts contacts contacts contacts Contact’s loading capacity and electrical endurance 4A 300000 cycles 10A 250000 cycles 4A 1000000 cycles 6A 20000 cycles 10A 20000 cycles - incandescent 1000W 100000 cycles 1800W 70000 cycles 600W 30000 cycles 1800W 18000 cycles 1800W 18000 cycles - halogen 1000W 100000 cycles 1800W 70000 cycles 600W 30000 cycles 1800W 18000 cycles 1800W 18000 cycles - fluo non compensated cos + 0.3 - - - - - - fluo in parallel compensated µf - - - - - Supply voltage 29V 29V 29V 29V 29V Consumption - - - - - Watts loss <8W <8W 6W 6W 6W Working temperature 0 to +45°C 0 to +45°C 0 to +45°C 0 to +45°C 0 to +45°C Storage temperature 0 to +45°C 0 to +45°C 0 to +45°C 0 to +45°C 0 to +45°C Dimensions 4 4 4 4 4 Connection: flexible rigid 1 to 6mm 1.5 to 10mm2 2 1 to 6mm 1.5 to 10mm2 Connection TS204A and TS204C Ph N 2 1 to 6mm 1.5 to 10mm2 2 1 to 6mm 1.5 to 10mm2 2 TS206A, TS206B and TS206C Ph N output 1 output 2 indicaion of switch state auto test / adressing button System voltage 29 V DC (SELV) operating push-button for manual operation 6 8 10 12 14 16 output 3 output 4 output 1 output 2 output 3 1 3 5 7 9 11 13 15 1 3 5 7 9 11 13 15 selection switch TS 204 Auto / Manu 1 to 6mm2 1.5 to 10mm2 selection switch TS 206 Auto / Manu auto test / adressing button 1 2 3 4 5 6 indication of switch state operating push-button for manual operation 6 8 10 12 14 16 System voltage 29 V DC (SELV) output 4 output 5 output 6 259 Tebis TS - output devices for lighting Dimming output devices TS 210 and TS210A direct output, TS211 3 outputs 1-10V The TS 210 and TS 211 are piloted via push-buttons connected to the input devices. One single push-button can pilot a dimming circuit: - short pushes will switch “ ON “ and “ OFF “ - long pushes will increase or decrease the lighting level An “ ON “ order will bring back the luminosity to the initial level. Technical characteristics references TS 210 and TS210A TS 211 number of outputs 1 direct output protected against overloads 2 outputs (per output : 1 contact TOR+1 - 10V) contact rating 600 W (see chart below) TS210 300W TS210A contact TOR 16A AC1 250 V same characteristics as TS200) output 1 - 10V : max. current 50mA supply voltage Bus + 230V 50Hz Bus + 230V 50Hz consumption 0.5VA 5VA power dissipation <5W 10 W working temperature 0 to +45 °C 0 to +45 °C storage temperature -20 to + 70 °C -20 to + 70 °C dimensions 4 6 connection: flexible 1 to 6mm2 1 to 6mm2 rigid 1.5 to 10mm2 1.5 to 10mm2 Connection TS210 TS211 + dimmer Ph N Ph N output 1 output 2 output 3 selection switch Auto / Manu indication of overload or overheating: - switched on for overheating - flashing for overload or short-circuit operating push-button for manual operation 1 3 TS 210 auto load load type indication Adressing button 14 16 1 3 TS 211 9 11 13 15 17 19 1 2 10 - + - + EV101 EV103 cd 3 load TS 211 + electronic ballast Ph N output 1 output 2 output 3 Working temperature 35 °C 45 °C mini load + System cd1 cd2 voltage 29 V DC (SELV) further bus connection Push-button load for configurat of load type (load select) Technical characteristics of load contacts TS 210 1 maxi load incandescent 20 W 600 W 500 W VL halogen 20 W 600 W 500 W Hal. VLV + convention. transfor. transfo 20VA Load 15 W transfo 600VA load 480 W transfo 500VA load 400 W Hal. VLV + electronic transfo 25VA transformer load 20 W transfo 600VA load 540 W transfo 500VA load 450 W 260 2 4 6 8 10 12 EV 103 Note: before using the TS 210, it has to be configured by specifying the load to be controlled. Type of load 3 12 14 16 18 20 - System voltage 29 V DC (SELV) 1 3 5 7 9 11 auto commut. Auto / Manu 3 TS 211 9 L N auto 1 10 - System voltage 29 V DC (SELV) 11 13 15 17 19 2 3 12 14 16 18 20 + cd1 cd2 further bus connection -+ -+ cd 3 1-10 V + - electronic ballasts fluorescent tube indication of switch state operating push-button for manu operation Tebis TS - output devices for blinds and shutters output for 4 blinds, shutters TS 223, TS 224, The range of products blinds and shutters covers two applications: - the unit TS 223 manage the orders rise, coming down, and stop. They will pilot rolling shutters, blinds. - the units TS 224 manage the orders rise, coming down, stop as well as tilting blinds. They will pilot blinds. In “ Auto “ mode the commands are supplied from the input devices of the Tebis system (TS304 or TS310). In the “ Manual “ mode, the commands are supplied locally from the push-buttons on the front of the device ( override ). Technical characteristics References TS 223, TS 224 number of output 4 contact rating 6 A AC1 250 V ~ electrical endurance 100 000 operations alimentation Bus consumption <02W power dissipation <1W working temperature 0 to +45 °C storage temperature -20 to +70 °C dimensions 4 Connection: flexible rigid 1 to6mm2 1.5 to 10mm2 Connection TS223 / TS224 Ph N selection switch Auto/Manu 1 3 5 7 9 11 13 15 1 2 3 4 load type indication adressing button System voltage 29 V DC (SELV) 6 8 10 12 14 16 indication of switch state operating push-button for a) programming b) manual operation - 1 push :down - 2 push :stop - 3 push :up - 4 push :stop - 5 push : down 261 Tebis TS - output devices for heating Output device for heating TS 244 Connections The output device TS 244 will carry out the “ ON “, “ OFF “ instructions given by: - the temperature controllers TS 320, TS 321 or TS 322 - traditional temperature controllers connected to the periodical pulsed entry module TS 303 Bus L The “ Manu “ mode allows the override of the different outputs. After 1 hour, in case of defect or absence of controllers, the TS 240 will ensure a no frost protection ( 1 minute “ ON “ - 4 minutes “ OFF “ ). The indication light of the output related to this protection is flashing. Bus 7 TS 244 number of output contacts 4 voltage free contacts contact rating 16 A AC1 250 V electrical endurance 20 000 operations supply voltage 29V consumption 5 VA power dissipation <8 W working temperature 0 °C to +45 °C storage temperature -20 °C to f70 °C dimensions 4 mod connection: flexible 1 to 6mm2 1,5 to 10mm2 13 15 auto 1 2 3 4 8 10 reference 262 9 TS 244 Technical characteristics rigid L System voltage 29 V DC (SELV) L 14 16 L Bus Bus Tebis TS - system devices Configuration unit TS 100 The configuration unit TS 100 defines the allocation and functions between the Tebis TS inputs and outputs ( for example TS 304 and TS 206 ). Connection Ph N BUS 0...9... Electrical characteristics: - supply voltage: 230 V~ 50 Hz, Bus 29 V, - power consumption: 7 VA, - power dissipation: 7 W. Operating data contact rating indicator output: 1 A 250 V~ Environment: - working temperature: 0 °C to +45 °C, - storage temperature: -20 °C to +70 °C. Connection - flexible : 1 to 6mm2 - rigid : 1.5 to 10mm2 1 3 11 13 reset 1/10 V STOP CL OK + System voltage 29 V DC (SELV) Power supply units TS 110, TS 111 Function The power supply units TS 110 and TS 111 generates the system voltage, which is necessary for the operation of the Tebis TS devices. The system voltage generated by the TS 110 and TS 111 meets the requirements of the protection measures SELV (separated extra-low voltage). TS 111 supply voltage 230 V~ 50 Hz 230V 50 Hz output voltage 29 V 640 mA 29 V 320 mA BUS indicator output clamps 17/19 : the contact is closed in case of system voltage loss. To indicate the loss a bell or an indicator light can be connected BUS further bus connection Connection TS110, TS111 Ph N Ph N L N TS 110 17 19 auto prog. 0...9... indicator (ex: ref SU213) output contact 11/13 : when programming the inputs, the output contact is closed with every audible confirmation of the TS100. A horn or a bell can be connected here which can be heard in the whole building. The indicaor output has no function in regular service. Q L1 N Q TS 111 TS 110 230 V 50/60 Hz 230 V 50 Hz L N I > I max. M OK Q M BUS 29 V reset OK reset power consumption 24 VA 15 VA connection: flexible rigid quick connection 1.5mm2 2.5mm2 screw terminals 0.75 to 2.5mm2 0.75 to 4mm2 System "reset" switch voltage 29 V DC (SELV) System voltage 29 V DC (SELV) working temperature -5 °C to +45 °C storage temperature -20 oC to +70 °C 263 Tebis TS - remote telephone interface TS003 Technical specifications Electrical characteristics: - supply voltage :230 V~ +10/-1.S’ 50/60 Hz - consumption: < 4 VA - output: 3 changeover contact voltfree contact max: 5A/250 V~ AC mini:100mA-12V~. Presentation TS 003 Line connection 1 2 Français Deutsch English Italiano ON OFF ON OFF ON OFF C1 C2 C3 - 6 5 Environment - Operating temperature 10 °C to +50°C - Storage temperature: -20 °C to +60°C Connection - capacity: flexible :1 to 2.5mm2 rigid: 1 to a 4mm2 Main characteristics • • • Voice assistance Fitted with a voice assistance to guide you in your choices and inform you about the status of the 3 circuits. Choice of 4 languages ( English, French, German, Italian ). Access code To limit usage only to the people having the code: - code set in factory - easy to personalise Timed switch-off Possibility to program each of the circuits to switch-off automatically after 1 to 100 hours. Manual control On the main unit press the ON or the OFF button corresponding to the circuit you want to turn either ON of OFF If the circuit is programmed for timed switch-off pressing the ON button starts the timer. • Use with a telephone answering machine The TS 003 can be installed on the same line as an answering machine, a fax or a modem without disturbances. • In case of power failure Your access code and the circuit programs remain stored in the memory. • Remote control Can be piloted via any cellular phone(GSM) without using the TU 001 decoder. Working principle Allows you to select your language, takes the line after 6 to 7 rings when you call your phone. A secret code allows you to limit the access to the persons of your choice. Provides ON/OFF or timed switch-off commands for 3 different circuits from any touchtone telephone to suit your requirements. Will automatically give the line free once you hang up. 264 4 3 ➀ On-line indicator light ➁Circuit operation indicator light ➂ Manual control push buttons ➃ Manual OFF push button ➄ Reset button, back to factory setting code 0000 ⑥ Language selection cursor wiring diagrams 11 12 13 14 15 16 17 18 19 20 TS 003 1 • Reset 2 3 4 5 6 7 8 9 10 The equipment has been approved in accordance with Council Decision 98/482/EC for pan-European single terminal connection to the public switched telephone network (PSTN). However, due to differences between the individual PSTNs provided in different countries, the approval does not, of itself, give an un-conditional assurance of successful operation on every PSTN network termination point. In the event of problems, you should contact your equipment supplier in the first instance.