PC Personal 120V 600VA 375W Standby UPS with Pure

Transcription

PC Personal 120V 600VA 375W Standby UPS with Pure
PC Personal 120V 600VA 375W Standby UPS with
Pure Sine Wave Output, Tower, 6 Outlets
NUMÉRO DE MODÈLE: BC600SINE
Points principaux
600VA tower 120V standby UPS
with SINE WAVE output
Maintains AC output during power
failures
3 UPS battery supported outlets,
3 surge-only outlets
USB port, Active PFC power
supply compatible, 97% efficient
NEMA 5-15P input plug and 6
NEMA 5-15R outlets
Inclut dans l'emballage
BC600SINE UPS System
USB Cable
Owner's manual
Présentation générale
Tripp Lite's BC600SINE UPS system provides long-lasting battery backup for professional workstations, PCs, networking equipment and other sensitive
electronics. Sine wave output in both line and battery power modes provides compatibility with all electronic loads, including PC and Mac systems fitted with
Active Power Factor Corrected (PFC) power supplies. Uninterruptible Power Supply switches to battery derived sine wave AC output during power failures and
severe voltage fluctuations so that connected equipment can be operated normally and shut down without data loss. Provides 18 minutes battery runtime with
a typical desktop computer system (100 watts). Includes 3 battery-supported outlets for computer, monitor and one vital system peripheral, plus 3 additional
surge suppression-only outlets for printers and other system accessories not requiring battery support. Built-in USB port enables data-saving unattended
shutdown when used with Tripp Lite's PowerAlert software, available via FREE download fromwww.tripplite.com/poweralert. USB port also enables integration
with built-in power management and auto shutdown features of Windows and Mac OS X. Built-in audible alarm and 4 front-panel LEDs indicate line power
status, battery power status, overload status and battery low/replace status. 650VA/375W power handling ability supports professional workstations, desktop
PCs, point-of-sale equipment, small business phone systems, audio/video equipment and home theater systems. Supports user battery replacement via
built-in access panel.
Fonctionnalités
Tripp Lite's BC600SINE tower, sine wave UPS system provides long-lasting battery backup for a variety of computer and electronic applications
Sine wave output in both line and battery modes provides compatibility with all electronic loads, including PC and Mac systems fitted with Active Power
Factor Corrected (PFC) power supplies
BC600SINE UPS system switches to battery derived sine wave AC output during power failures and severe voltage fluctuations with enough time to shut
down without data loss
650VA / 375 watt UPS capacity with 3.3 minutes runtime at 100% load and 11.1 minutes at 50% load
Provides 18 minutes battery runtime with a typical desktop computer system consuming 100 watts
Includes 3 battery-supported outlets for computer, monitor and one vital system peripheral, plus 3 additional surge suppression-only outlets for printers
and other system accessories not requiring battery support
Built-in USB port enables data-saving unattended shutdown when used with Tripp Lite's PowerAlert software, available via FREE download from
www.tripplite.com/poweralert
HID-compliant USB port enables integration with built-in power management and auto-shutdown of Windows and Mac OS X
PowerAlert software CD included
1/5
PowerAlert software CD included
Built-in audible alarm with cancel switch warns of power failure conditions; once silenced, alarm will re-sound as batteries approach full discharge
Alarm can be permanently silenced via PowerAlert interface
4 front panel LEDs indicate line power status, battery power status, overload status and battery low/replace status
Supports user hot-swappable battery replacement via built-in access panel
Optional PDUB15 bypass PDU enable hot-swappable UPS replacement with no disruption to connected equipment
$150,000 Ultimate Lifetime Insurance (U.S., Canada, and Puerto Rico only)
Caractéristiques
Sortie
Puissance en volts-ampères (VA)
600
Capacité en sortie (Watts)
375
Tension(s) de sortie nominale(s)
prise(s) en charge
110 V; 115 V; 120 V
Détails de la tension nominale
120v nominal output in battery mode
Compatibilité avec fréquences
60 Hz
Régulation de la tension de sortie
(mode batterie)
+/- 5%
Prises de sortie
(6) 5-15R
Prises de sortie pour onduleur
(Protection contre les surtensions
uniquement)
3 prises alimentées par la batterie de l'onduleur, 3 prises anti-surtension uniquement
Options de PDU échangeable à
chaud
PDUB15 (2U / 8 prises 5-15R)
Forme d'onde CA de sortie (mode
CA)
Sine wave
Forme d'onde de sortie CA (mode
Batterie)
Signal sinusoïdal pur
Entrée
Courant d'entrée nominal (charge
maximale)
10A Max (UPS and surge-only loads combined)
Tension(s) d'entrée nominale(s)
prise(s) en charge
120 V CA
Type de connexion d'entrée de
l'onduleur (UPS)
5-15P; À angle droit
Longueur du cordon d'entrée de
l'onduleur (pi)
6
Longueur du cordon d'entrée de
l'onduleur (m)
1.8
Service électrique recommandé
15A 120V
Phase en entrée
Monophasé
2/5
Batterie
Durée de fonctionnement à pleine
charge (min.)
3.3 min. (375 watts)
Durée de fonctionnement à
demi-charge (min.)
11.1 min. (190 watts)
Tension du système CC (V CC)
12
Taux de recharge des batteries
(Batteries incluses)
Less than 9 hours from 10% to 90%
Cartouche de batterie de rechange
de l'onduleur interne
RBC51
Accès aux batteries
Battery access door
Description du remplacement de la
batterie
Hot-swappable, user replaceable batteries
Autonomie extensible
Non
Interface Utilisateur, Alarmes et Contrôles
Switches
2 Switches control off/on power status and alarm-cancel/self-test operation
Fonctionnement de l'annulation
d'alarme
Power-fail alarm can be silenced during a power failure using alarm-cancel switch; alarm can be permanently
disabled via PowerAlert software interface
Alarme sonore
Audible alarm indicates power failure and overload conditions
Indicateurs LED
LINE POWER (green), INVERTER MODE (yellow), OVERLOAD (red), REPLACE BATTERY (red)
Suppression de Bruit / Surtensions
Coefficient de suppression Joules
CA onduleur
252
Temps de réponse suppression CA
onduleur
Instantaneous
Suppression de bruit CA RFI / IEM
Oui
Physiques
Facteurs de forme d'installation pris
en charge avec accessoires inclus
Tour
Facteur de forme primaire
Tour
Dimensions du module
d'alimentation de l'onduleur (hlp, po)
10.75 x 5.25 x 7.5
Dimensions du module
d'alimentation de l'onduleur (hlp, cm)
27.3 x 13.3 x 19.1
Poids du module d'alimentation de
l'onduleur (livres)
14.6
Poids du module d'alimentation de
l'onduleur (kg)
6.62
3/5
Dimensions d'expédition de
l'onduleur (hlp / po)
14 x 10.5 x 8.25
Dimensions d'expédition de
l'onduleur (hlp / cm)
35.6 x 26.7 x 21
Poids d'expédition (livres)
15.7
Poids d'expédition (kg)
7.1
Méthode de refroidissement
Fan
Matériau du boîtier de l'onduleur
PVC
Hauteur de l'onduleur principal (mm)
273
Largeur de l'onduleur principal (mm)
133
Profondeur de l'onduleur principal
(mm)
190
Hauteur d'expédition (mm)
356
Largeur d'expédition (mm)
267
Profondeur d'expédition (mm)
210
Ecologique
Plage de température de
fonctionnement
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Plage de température de stockage
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Humidité relative
0 to 95%, non-condensing
BTU mode CA / Hr. (pleine charge)
33
BTU mode batterie / Hr. (pleine
charge)
361
Coefficient de rendement mode CA
(Charge 100 %)
97%
Communication
Interface de communication
USB (compatible HID)
Logiciel PowerAlert
For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at
http://www.tripplite.com/poweralert
Câble de communications
USB cable included
Compatibilité WatchDog
Supports Watchdog application, OS and hard-reboot restart options for remote applications
Compatibilité outils onduleur réseau
NUT compatible. See the full list of Tripp Lite NUT compatible UPS systems at
http://www.networkupstools.org/stable-hcl.html?manufacturer=Tripp Lite
Transfert Ligne / Batterie
Temps de transfert
Battery to line mode: 2 milliseconds / Line to battery mode: 5 milliseconds
Transfert basse tension vers
alimentation batterie (Consigne)
99V
4/5
Transfert haute tension vers
alimentation batterie (Consigne)
139V
Fonctions spéciales
Démarrage à froid (Démarrage en
mode batterie pendant une coupure
de courant)
Cold-start operation supported
Fonctions de haute disponibilité de
l'onduleur
Batteries remplaçables à chaud
Fonctions d'économie d'énergie
Efficacité supérieure à 95% - UPS ECOLOGIQUE
Certifications
Certifications onduleur
Testé selon la norme UL1778 (États-Unis); Testé selon les normes CSA (Canada); Testé selon les normes NOM
(Mexique); Certifié FCC Part 15 Category B (EMI); ROHS (limitation de l'utilisation des substances dangereuses)
Garantie
Période de garantie du produit
(États-Unis et Canada)
Garantie limitée de 3 ans
Période de garantie du produit
(Amérique Latine)
Garantie limitée de 3 ans
Période de garantie du produit
(Internationale)
Garantie limitée de 2 ans
Période de garantie du produit
(Mexique)
3-year limited warranty
Assurance équipements connectés
(États-Unis, Canada et Porto Rico)
$150,000 Ultimate Lifetime Insurance
© 2016 Tripp Lite. Tous les droits sont réservés. Tous les noms de produits et de sociétés sont des marques commerciales ou des marques déposées de leurs
détenteurs respectifs. Leur utilisation ne comporte aucune affiliation avec ou approbation par eux. Tripp Lite a une politique d'amélioration continue. Les
spécifications sont sujettes à modification sans préavis. Tripp Lite utilise les agences primaires et de tiers pour tester ses produits pour conformité aux normes.
Voir la liste des agences d’essais de Tripp Lite:
5/5