scheda offerta hot runner cc

Transcription

scheda offerta hot runner cc
SCHEDA OFFERTA HOT RUNNER
CC____/_____
SIPA S.p.A. - Via Caduti del Lavoro, 3 - 31029 Vittorio Veneto (Italy)
Tel: +39 0438911511 Fax: +39 0438912273- www.sipamolds.com
CLIENTE___________________Via___________________Cap_________Città________
Rif. Cliente_____________Tel______________Fax____________e-mail______________
Agente_________________Data_________Firma__________Data Consegna__________
Descrizione_________________ Materiale_______________ Produttore_____________
Temp. Fusione °C________ Temp. Stampo °C________ MFI_______ Viscosità______ IV
Cambio colore
Sì
No ___________________ Caricati
Sì
No _________
N° Impronte ________ N° Ugelli______ Peso iniettato per ogni ugello gr.____________
Spes. Medio ______________________________________________________________
Tipologia Iniezione Diretta sul pezzo Con bugna Su materozza Su parete inclinata
Tempo ciclo richiesto___________sec. Tempo ciclo per iniezione________________sec.
NOZZLES
HOT HALF
HOT MANIFOLD
Thermal Gate TTN-BTTN-TBN-BTBN-TSN-BTSN- TTN A10
Dim. hot half (LxBxH)________________
Otturazione TVN
N° File______________Passo ________
Flusso libero SFNT-SFNB-SFNS
Passo Centrale_______Interasse______
Multipoint MPN
N° Gate ____________
Laterale SGN
N° Gate ____________
Codice ugello ________________________
Ø Gate_________
H. ugello __________
Body
Flat
O-Ring
Radius
Flangia ugello
Si
No
Sede tip In figura
Ricavata in matrice
Uscita cavi ugelli
Adiacente matrice
Sottotesta ugello
Int. Centrale ______________________
Codice __________________________
Ø Anello di centraggio ______________
Ingresso camera calda Ø______R_____
Piastra isolante Sì
No Dim._______
Uscita cavi
Alto Stampo
Lato operatore
Lato op. operat.
ALTO STAMPO
VALORI ESPRESSI IN mm
LATO OPERATORE
CENTRALINA
SI – codice _____________________
NO (Fornire schemi elettrici )
Zone di termoregolazione:
NOZZLE n° ______ INGRESSO n° _____
HOT MANIFOLD n° _________________
Max. Amp. per zona _________________
Termocoppie
J
K
a massa
isolate
VISTA DA UGELLO PRESSA
NOTE
__________________________________
__________________________________
__________________________________
__________________________________
__________________________________
I valori espressi nelle tabella e rappresentazioni sopra indicate sono da confermarsi in fase di progetto.
Above metioned values shall be confirmed.
Les valeurs mentionnées dans la table et les illustrations supra doivent être validées au moment de la conception.
Die in den Tabellen und Abbildungen angegebenen Werte sind in der Projektphase zu bestätigen.
THERMODYNE HotRunner Systems - SIPA Division
October 2011
Sez. 6
Via Caduti del Lavoro 3, 31029 Vittorio Veneto Tel: +39 0438911511 Fax: +39 0438912273
www.thermodyne.it - e-mail [email protected]
Pag. 1
OFFER CARD HOT RUNNER
CC____/______
SIPA S.p.A. - Via Caduti del Lavoro, 3 - 31029 Vittorio Veneto (Italy)
Tel: +39 0438911511 Fax: +39 0438912273- www.sipamolds.com
CUSTOMER________________Address ________________________________________
Contacted person _____________Tel____________Fax____________e-mail_____________
Agent_______________Date_________Signature_____________Delivery_____________
Description _________________ Material________________ Producer_______________
Melt Temp. °C________ Mould Temp. °C________ MFI_______ Viscosity______ IV
Color change
Yes
No ________________ Mineral charge
Sì
No _________
N° Cavity ________ N° Nozzle______ Injected weight for each nozzle gr.____________
Medium thicness mm_________________________________________________________
Injection type: Flat surface
Excellent gate vestige
In sprue
In sidewall-inclination
Cicle time _______________sec. Injection Time ________________sec.
NOZZLES
HOT HALF
HOT MANIFOLD
Thermal Gate TTN-BTTN-TBN-BTBN-TSN-BTSN- TTN A10
Dimen. hot half (LxHxW)______________
Valve Gate TVN
N° Rows______________Pitch ________
Straight Flow SFNT-SFNB-SFNS
Central Pitch_______Dist. Bet. Row_____
Multipoint MPN
N° Gate ___________
Side Gate SGN
N° Gate ___________
Nozze code __________________________
Ø Gate________ Height Nozzle __________
Body
Flat
O-Ring
Radius
Nozzle flange
Yes
No
Tip
In figure
In cavity plate
Cable nozzle exit
Adjacent cavity plate
Underhead nozzle
Central Dist. bet.Rows _______________
Code ____________________________
Ø Centering ring ____________________
Hot manifold inlet Ø______R______
Insulating plate Yes
No Dim._______
Cable hot half exit
Top of the mould
Operator side
Opposite of Op. side
TOP OF THE MOULD
METIONED VALUES IN mm
OPERATOR SIDE
CONTROLLER
Yes – code _____________________
NO (Please send electrical diagram)
Thermoregulation zone:
NOZZLE n° ___ SPRUE INLET n° _____
HOT MANIFOLD n° _________________
Max. Amp. for zona _________________
Thermocouples
J
K
not-insulated
insulated
VIEW FROM NOZZLE EXTRUDER
NOTE
__________________________________
__________________________________
__________________________________
__________________________________
__________________________________
I valori espressi nelle tabella e rappresentazioni sopra indicate sono da confermarsi in fase di progetto.
Above metioned values shall be confirmed.
Les valeurs mentionnées dans la table et les illustrations supra doivent être validées au moment de la conception.
Die in den Tabellen und Abbildungen angegebenen Werte sind in der Projektphase zu bestätigen.
THERMODYNE HotRunner Systems - SIPA Division
October 2011
Sez. 6
Pag. 2
BULLETIN D’OFFRE HOT RUNNER
CC____/______
SIPA S.p.A. - Via Caduti del Lavoro, 3 - 31029 Vittorio Veneto (Italy)
Tel: +39 0438911511 Fax: +39 0438912273- www.sipamolds.com
CLIENT________________Adresse ______________________________________________
Personne à contacter _____________Tél____________Fax____________e-mail_____________
Agent______________Date_________Signature_____________Date de livraison__________
Description _________________ Matériel________________ Fabricant__________________
T fusion °C___________ T moule °C___________ MFI__________ Viscosité____________ IV
Change de couleur
Oui
Non ___________ Charge minérale
Oui
Non _________
N.bre d’empreintes ________ N.bre de buses______ Poids injecté par buse g ___________
Epaisseur moyenne mm_________________________________________________________
Type d’injection : Directe
Avec panneau Sur carotte
Sur paroi inclinée
Durée du cycle _______________s. Durée de l’injection _________________s.
BUSES
Thermal Gate TTN-BTTN-TBN-BTBN-TSN-BTSN- TTN A10
PARTIE CHAUDE
HOT MANIFOLD
Dim. Partie chaude (LxHxW)______________
Valve Gate TVN
N° Files______________Pas ____________
Straight Flow SFNT-SFNB-SFNS
Pas central __________Entraxe __________
Multipoint MPN
Entraxe central _______________________
N° Gate ___________
N° Gate ___________
Side Gate SGN
Code buse __________________________
Ø Trou________ Hauteur Buse __________
Corps
Flat
O-Ring
Radius
Flasque buse
Oui
Non
Tip
En figure
Dans matrice
Sortie câble buses
Côté matrice
Sous tête buse
Code _______________________________
Ø Bague de centr. _____________________
Entrée chambre chaude Ø______R________
Plaque isolante Oui
Non Dim.____ ____
Sortie câbles
Sommet du moule
Côté opérateur
Côté op. opérateur
SOMMET DU MOULE
VALEURS EXPRIMEES EN MM
COTE OPERATEUR
REGULATEUR
Oui – code _____________________
NON (Envoyer le schéma électr. SVP)
Zone de régulation thermique:
BUSE n° ___ ENTREE COULEE n° _____
HOT MANIFOLD n° __________________
Max. Amp. zone ____________________
Thermocouples
J
K
non isolé
isolé
VUE DEPUIS LA BUSE DE LA PRESSE
NOTES
__________________________________
__________________________________
__________________________________
__________________________________
__________________________________
I valori espressi nelle tabella e rappresentazioni sopra indicate sono da confermarsi in fase di progetto.
Above metioned values shall be confirmed.
Les valeurs mentionnées dans la table et les illustrations supra doivent être validées au moment de la conception.
Die in den Tabellen und Abbildungen angegebenen Werte sind in der Projektphase zu bestätigen.
THERMODYNE HotRunner Systems - SIPA Division
October 2011
Sez. 6
Pag. 3
HOT RUNNER ANGEBOTSFORMULAR
CC____/______
SIPA S.p.A. - Via Caduti del Lavoro, 3 - 31029 Vittorio Veneto (Italy)
Tel: +39 0438911511 Fax: +39 0438912273- www.sipamolds.com
KUNDE________________Addresse ________________PLZ_____________Ort___________
Kontakperson_____________Tel____________Fax____________E-Mail_____________
Vertreter_______________Datum______Unterschrift_____________Lieferdatum___________
Beschreibung _________________ Material________________ Hersteller_______________
Schmelztemp. °C________ Formtemp. °C________ MFI_______ Viskosität______ IV
Farbveränderung
Ja
Nein ________________ Mineralladung
Ja
Nein_________
Anz. Eindrücke ______ Anz. Düsen _____ Schussgewicht für jede Düse Gr.____________
Durchschn. Dicke mm_________________________________________________________
Spritzgießtyp: Direkt auf das Werkstück
Mit Überhang
Auf Speiser
Auf Schrägwand
Erforderte Zykluszeit _______________sec. Zykluszeit für Einspritzen ________________sec.
DÜSEN
HOT HALF
HOT MANIFOLD
Thermal Gate TTN-BTTN-TBN-BTBN-TSN-BTSN- TTN A10
Abmess. Hot Half (LxHxW)______________
Ventilverschluss TVN
Anz. Reihen____________Abstand________
Freier Fluss SFNT-SFNB-SFNS
Zentraler Abstand______Mittenabstand_____
Multipoint MPN
Zentr. Mittenabstand _______________
Anz. Gates ___________
Seitlich SGN
Anz. Gates ___________
Düsencode __________________________
Ø Verschluss_____ Düsenhöhe __________
Körper
Flach
O-Ring
Radius
Düsenflansch
Ja
Nein
Tip-Sitz
Am Werkstück In Matrize
Ausgang Düsenkabel
An Matrize anliegend
Düsen-Unterkopf
Code ____________________________
Ø Zentrierring ____________________
Eingang Warmkammer Ø______R______
Isolierplatte Ja
Nein Abm._______
Kabelausgang
Oberseite Form
Bedienerseite
Gegenüber Bedienerseite
OBERSEITE DER FORM
WERTE IN MM AUSGEDRÜCKT
BEDIENERSEITE
STEUERUNG
Ja – Code _____________________
NEIN (Bitte Schaltschemen beilegen)
Zonen der Temperaturregelung:
DÜSE Nr. ___ EINGANG Nr. _____
HOT MANIFOLD Nr. _________________
Max. Amp. pro Zone _________________
Thermoelemente
J
K
nicht isoliert
isoliert
ANSICHT VON DER DÜSE DER PRESSE
ANMERKUNGEN
__________________________________
__________________________________
__________________________________
__________________________________
__________________________________
I valori espressi nelle tabella e rappresentazioni sopra indicate sono da confermarsi in fase di progetto.
Above metioned values shall be confirmed.
Les valeurs mentionnées dans la table et les illustrations supra doivent être validées au moment de la conception.
Die in den Tabellen und Abbildungen angegebenen Werte sind in der Projektphase zu bestätigen.
THERMODYNE HotRunner Systems - SIPA Division
October 2011
Sez. 6
Pag. 4