Manual
Transcription
Manual
PRO ACID System USER GUIDE Service / Site Référence Version Date version Page : QUAL / France : 0016 : V.04.0 : 07/07/2014 : 1/9 Pro ACID System - Installation GB 140 75 Filter gasket A 3 wall plugs S7 3 S/st screws 5,5x38 E 244 Water pressure 2 to 6 bars B WATER 1700 Fiber gasket Quick coupler D C F IMPORTANT ! Ajuster IMPORTANT ! la longueur du tuyau Adjust thepour lenght d’aspiration queof la hosecrépine to the yellow repose filter verticalement sur le that rest upright onfond the du bidon bottom 2 wall plugs S7 2 S/st screws 5,5x38 2 rondelles L6 inox. Les cotes installation d’installation (endimensions mm) sont données titre indicatif These are àindicative FILTER MONTAGE GASKET DU JOINT ASSEMBLY FILTRE A FIBER MONTAGE GASKET DU JOINT ASSEMBLY FIBRE Outillage Needednécessaire tools : 1 drill : 1 forêt Ø 7mm Ø 7mm and 1etscrew 1 tournevis driver cruciforme cruciform DILUTION DESTIP BUSES MONTAGE BLUE RING DU COUPLEUR QUICK COUPLER RAPIDE A MONTAGE DE ASSEMBLY DILUTION BAGUE ASSEMBLY BLEUE C B 150 OPTION S/st can holder. (5L) 500 © All rights reserved 160 Fiber gasket Adaptator Coupler Coupler Blue ring Hose insertion Clamping ring IMPORTANT ! Respect the gasket orientation D WAND ASSEMBLY E Check valve Tip PERÇAGE HOLE OF THE DES BOUCHONS TAPE F Handle Nut + gasket Wand 1 trou Ø10mm Hose PACKING LIST OF THE PULV ACIDE SYSTEM 1_PULV ACIDE Sy stem (PVC) 1_Bag w ith connection kit = 1_Suction line (cry stal hose) L:2,5m 1_Inlet hose of w ater (L: 2m) Ø12/19mm 1_Yellow filter w ith w eight. 1_Ø12/19mm Discharge hose, 10, 15 or 25m according to model 1_Bag of 15 tips 1_Stainless steel lance no-scratch L: 60 or 120cm according to model 1_Nipple for quick coupler M-F3/4" 1_Instruction sheet 1_Quick coupler ring blue 1_Quick coupler ring red 1_Bag w ith screw s and gaskets1 Rubber gasket blue 3/4" 1_Green fiber gasket 3/4" 3 S/st screw s. Ø5,5x 37 3 w all plugs S7 NTPUASLB V.04.0 p.6/9 Pro ACID System - Use GB A Water pressure 2 to 6 bars Maximum temperature working= 20°C CLOSE B OPEN Safety rules S36/37/39 Wear protection coat Wear protection gloves © All rights reserved Wear protection glasses and mask CAUTION ALWAYS orientate spray in direction of surfaces to treat. NEVER orientate spray in direction of people, animals or plants USE 1° Open the valve inlet water « A » 2° Press the lever « B » handle spraying. 3° Wait a few seconds the rise of production in the suction line. 4° Close the inlet vale « A » after use. ALWAYS w ait few seconds for a good product and w ater mix ing. ALWAYS close w ater inlet v alv e after each use. WATER PRESSURE must be included on 2 bar to 6 bar. MAXIMUM w orking temperature is 50°C ALWAYS keep the unit on frost protection METHOD OF DILUTION CALCUL TABLEAU DE DILUTION PULV ACIDE Couleur Produit Couleur Produit Pink 0,5% Blue 9,4% Purple 1,3% White 10,4% Turquoise 1,5% Red 12,6% Dark brow n 2,2% Beige 15,3% Yellow 2,6% Black 16,4% Orange 3,8% Grey 16,6% Green 5,8% Without tip 17,0% Light brow n 7% Incolore Bouchon This table is done to help you to choose a tip according to expected concentration EXEMPLE: 15 (A) x 100%= 1.5% 1000 (B) (This drawing is an exemple) Volume B (1000 cl ou 10 000 ml) Volume A (15 cl ou 150 ml) CONDITIONS DES TESTS Dynamic water pressure = 2,5 bars 25m hose 60cm et 120 cm wand Volume A : breathed product Volume B : solution (water + breathed product) NTPUASLB V.04.0 p.7/9 Pro ACID - Troubles GB Water pressure 2 bars to 6 bars © All rights reserved Maximum temperature working: 20°C Check valve cleaning Spring MAINTENANCE ? PULV ACIDE system does not aspire product. 1° Check the pressure of the water system (minimum : 2 bar, max : 6 bar) 2° Check that the filter gasket is not dirty or scaled. (clean or replace) 3° Check that the yellow filter of the suction line is submerged in the product, and the hose is not pinched, folded, or closed. 4° Verify that the tip is not clogged. (clean or replace) 5° Check that the yellow filter of the suction line is not dirty. (clean or replace) 6° Check that the spray handle is not dirty or calcified. (clean or replace) 7° Check that the flat spray nozzle is not dirty or calcified. (clean or replace) ? The product can filled with water.. 8° Verify that the check valve is not dirty or calcified. (clean or replace) Ceramical O ring ball Spray nozzle cleaning Nut of lance Gasket Flat spray nozzle Nozzle holder NTPUASLB V.04.0 p.8/9 Pro ACID- Description GB 1 3 2 19 Water pressure 2 bars to 6 bars 16 WATER 4 5 9 7 10 6 8 11 18 12 13 14 17 Safety rules S36/37/39 15 Wear protection coat © All rights reserved 20 Wear protection gloves Wear protection glasses and mask PULV ACIDE system is intended for the determination and application of shampoo for automobile bodies. ACCESSORIES AND SPARE PARTS PULV ACIDE Designation Repère Back plate PULV ACIDE - White PVC Personnal logo Hose connection Ø12/19 - Lg 2m - Green Fiber gasket 3/4" black (bag of 10) Nipple for quick coupler 3/4" Brass quick coupler blue Stop vlave Venturi assembly PVDF Dilution tips (bag of 15) Check valve White/Yellow (gasket FPM) S/st screw M5x45 (x2) Hose blocker (PVDF) Hose connection nut Suction line Lg: 2m (Cristal hose Ø 6/9) Yellow filter with weight Spray handle with quick coupler PVC wand no-scratch. Lg: 60 or 120 cm (depend of version) Blue discharge hose Ø12/19 PVC. 10,15, or 25m (depend of version) Filter gasket 3/4" black (bag of 5) Spray nozzle (60° - 9,8L/mn) spray nozzle holder 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 20 NTPUASLB V.04.0 p.9/9