Synthèse organique micro-ondes Organic Microwave
Transcription
Synthèse organique micro-ondes Organic Microwave
54, rue Roger Salengro - BP 115 - 94126 -FONTENAY-SOUS-BOIS CEDEX– Synthèse organique micro-ondes Organic Microwave Synthesis SYNTHEWAVE 1000 NOTICE TECHNIQUE SERVICE MANUAL P78962 02 B20546 NOMENCLATURE / REFERENCES Principaux composants du module micro-ondes SYNTHEWAVE 1000 Main components of the SYNTHEWAVE 1000 microwave module SYNTHEWAVE 1000 PROLABO 300 302 497 596 301 597 598 304 SYNTHEWAVE 1000 2 P78 962 02 NOMENCLATURE / REFERENCES REPERE CODE 497 300 301 302 598 597 596 304 17239327 06402635 06402657 00963143 19093417 19093678 19093667 06402646 REF CODE 497 300 301 302 598 597 596 304 17239327 06402635 06402657 00963143 19093417 19093678 19093667 06402646 SYNTHEWAVE 1000 DESIGNATION Cristallisoir inox Doigt de gant quartz à hublot équipé Agitateur pour liquides Bouchons verre 29/32 Cordon RS232 Adaptateur RJ45/SUBD9 Adaptateur RJ45/SUBD25 Réacteur quartz NAME Stainless steel crystallizing pan Quartz glove finger with équipped porthole Liquid stirrer Glass stoppers 29/32 RS232 lead RJ45/SUBD9 pin adaptor RJ45/SUBD25 pin adaptor Quartz reactor 3 P78 962 02 TABLEAU DE DIAGNOSTIC DEFAUTS Le voyant jaune de l’interrupteur secteur du module à micro-ondes ne s’allume pas CAUSES POSSIBLES Fusible secteur F1 endommagé (repère 578) Voyant défectueux Problème arrivé secteur Le voyant vert est éteint, bien La porte de l’appareil n’est que le voyant jaune soit pas verrouillée en position allumé, affichage à l’écran du message porte ouverte ou surchauffe du magnétron. Un switch de fermeture de porte est défectueux. (repère 545) Le thermo-contact de surchauffe magnétron est endommagé. (repère 550) Surchauffe du magnétron: ventilation commune pour le magnétron et la carte de puissance. (repère 565) Un des 5 swicths de sécurité porte n’est pas en position Voyant défectueux Le voyant vert est allumé mais le voyant rouge reste éteint malgré une puissance micro-onde programmée. Voyant défectueux ACTIONS CORRECTIVES Contrôler la position électrique des switchs de porte Changer le fusible F1 (voir chapitres entretien maintenance et pièces de rechange) Verrouiller complètement la porte de l’appareil, si le voyant vert s’allume, faire changer l’interrupteur. Vérifier le branchement et l’état du cordon secteur.Vérifier la tension secteur Vérifier le bon positionnement de la porte et manoeuvrer les vis de bridage. – Si le voyant reste éteint; Vérifier la commande mécanique des switchs. La puissance micro-onde est sollicitée, – Les voyants vert et rouge restent éteints; Changer le switch de porte, voir le SAV. Les 2 voyants sont éteints la porte est fermée, si le voyant vert ne s’allume pas après 5 à 10 minutes d’arrêt; Changer le thermo-contact, voir le SAV. Les voyants vert et rouge s’éteignent pendant le déroulement du programme, – Dégager les prises d’air autour de l’appareil – Le S1000 est installé dans une zone chaude. – Vérifier le fonctionnement du ventilateur; Changer la ventilation, voir le SAV. Le fusible F2 est détruit Contacter le SAV Lors de la commande de puissance, si le voyant rouge s’allume, faire changer le voyant vert. Si le produit chauffe faire changer le voyant rouge. La programmation n’est pas correctement effectuée. Le voyant vert est allumé, affichage à l’écran d’un message: Erreur de communication SYNTHEWAVE 1000 Le programme n’a pas démarré, – Vérifier sur la notice, de l’utilisation correct du programme. Mauvais fonctionnement de la Faire appel au service après vente. carte de puissance (repère 570) Le cordon de la liaison RS232 Démonter la trappe sur le coté de l’appareil, est défectueux. (repère 598) – Le cordon RS232 est-il branché ?, – Vérifier le cordon et l’adaptateur sur le PC; Changer l’élément défectueux. 4 P78 962 02 TABLEAU DE DIAGNOSTIC DEFAUTS L’éclairage du guide ne fonctionne pas, malgré sa commande actionnée La température est asservie, mais la valeur affichée à l’écran reste inférieure à la valeur de consigne, ou la montée en température est très lente. La température réelle dans le matras est plus haute que la valeur affichée. SYNTHEWAVE 1000 CAUSES POSSIBLES ACTIONS CORRECTIVES Les lampes sont hors d’usage (repère 501) Démonter le capotage et le déflecteur (voir chapitre maintenance) - vérifier le branchement des lampes, et remplacer les lampes usagées. Le produit chauffé est non Faire un essai avec de l’eau dans le matras en polaire. asservissement de température; – Pour une consigne de 70°C et 300ml d’eau, la température stabilise en 9 minutes environ. Programmation en puissance Augmenter la valeur de la puissance maxi.; trop faible. – Vérifier que la température monte plus vite. Le magnétron ne délivre plus Qu’elle que soit la consigne affichée, la montée la puissance nécessaire. en température est très lente; (repère 555) Changer le magnétron, voir le SAV. L’écran de renvoi de spot sur Démonter la trappe sous l’appareil, la zone de mesure est peut– Dévisser l’écran de renvoi de spot, être souillé. – Nettoyer l’écran avec de l’alcool et un frotter (repère 138) avec un chiffon doux. La fenêtre du doigt de gant est Démonter la fenêtre du doigt de gant, souillée. (repère 213+402) – Nettoyer la fenêtre avec de l’alcool et frotter avec un chiffon doux. 5 P78 962 02 TROUBLE-SHOOTING FAULT The yellow lamp on the on/off switch will not come on. POSSIBLE CAUSES CORRECTIVE ACTION Check the position of électrical swiches of the door. Change fuse 1(see maintenance and spare part chapters) Indicator failure Completely close the instrument door, if the green indicator lights up, change the main switch There is a problem on the If the green lamp remains off, mains feed check the connection of the main lead, the state of the lead, and the main voltage. The green lamp is off, even The door of the apparatus is Check the proper position of the door and turn though the yellow lamp is on, not locked in position the and a screen clamping screws. - If the signal lamp is still off, check the mechanical control of the switch . The microwave power is being drawn used, but message says "Door open or The door-closing switch is faulty (Ref. 545) the red and green lamps remain off. Change the magnetron overheating". door switch or consult the after-sales service. The thermal contact on the Both lamps are off though the door is closed. If magnetron is damaged the lamp does not come on after 5 minutes at a (Ref. 550). halt, then change the thermal contact or consult the after-sales service. Overheating of magnetron:the The green and red lamps go off while the ventilation is the same for the program is running. magnetron and the power – Clear the air intakes around the instrument, supply board.(ref.565) – the S1000 has been located in an excessively hot area. – Check the operation of the fans. Change the ventilation components or consult the after-sales service. One of the door’s 5 safety Fuse F2 is destroyed: contact the after sales switches is not in position. service. Indictor failure During a power command, if the red indicator lights up, change the green indicator. The green lamp is on, but the Indicator failure If the product heats, change the red indicator red lamp stays off even though microwave heating has been programmed. Programming has not been The program has not started up. done correctly Check with the operating instructions for correct execution of the program. Malfunction of digester Call the after-sales service power board (ref: 570) The green lamp is on, and a The RS232 lead is faulty Remove the cover at the right side of the (Ref. 598) instrument. "Transmission problem" - Is the RS232 lead connected? message appears on the - Check the lead and the connector on the screen. computer. Change any faulty parts. SYNTHEWAVE 1000 F1 main fuse dammaged (ref:578) 6 P78 962 02 TROUBLE-SHOOTING FAULT POSSIBLE CAUSES Guide lighting is not working,even though its control has been operated The lamps has blown (ref:501) The temperature is being controlled, but the value displayed on the screen remains below that of the setpoint, or the temperature rise is very slow The substance being heated is non-polar. The actual temperature in the flask is higher than the value displayed. SYNTHEWAVE 1000 The programmed power is too low. The magnetron is not delivering the required power (Ref. 555) The window for spot transmission to the measurement zone may be dirty (Ref. 138) The window of the glove finger is dirty (Ref. 213+402) 7 CORRECTIVE ACTION Remove the covering and the deflector (see maintenance chapter). -Check the connection of the bulbs, and replace used bulbs. Do a test with water in the flask and controlling the temperature. For a setpoint of 70°C and 300 ml of water, the temperature should stabilise within about 9 minute. Increase the maximum power value. Check that the temperature rises faster. Whatever the setpoint displayed, the temperature rise is very slow. Change the magnetron, and finally consult the after-sales service. Remove the cover on the bottom of the instrument. Unscrew the spot transmission screen. Clean this screen wit alcohol and wipe it with a soft cloth. Remove the window of the glove finger. Clean the window with alcohol, and wipe it with a soft cloth. P78 962 02 SCHEMAS ECLATES / EXPLODED VIEWS 146 420 209 421 501 405 154 SYNTHEWAVE 1000 PROLABO 213+402 134 407 520 147 406 138 503 545 404 593 506 560 137 565 408 555 550 500 211 403 570 579 578 535 525 135 SYNTHEWAVE 1000 8 P78 962 02 PIECES DE RECHANGE REPERE CODE 154 146 147 134 135 209 211 213 402 137 403 404 405 406 407 408 138 420 421 425 --500 17239010 17239021 17239076 17239087 17239098 17239112 17239134 17239156 19671610 17239167 19615855 19615866 17239178 17239180 19747678 17239271 17233145 19573121 09838106 19573440 08504287 19514468 17233282 17231503 17231605 19112664 19013161 19073076 19048002 19015032 570 570 520 501 545 593 555 550 506 560 560 578 578 579 579 503 565 535 535 525 525 SYNTHEWAVE 1000 19044783 19181593 19181605 19082727 19082751 19082443 19082454 19671107 19900747 19048946 19048935 19093703 19093510 DESIGNATION Cavité Porte Platine Support interrupteur général avec polyester Carénage de prises+ embase jack Joint de porte avec vis de serrage et gaines Vis de serrage agitateur Fixation hublot étanche Hublot ZnSe Ø19x2 (paquet de 5) Capot de cavité inox avec étiquette et écran Capot de porte inox équipé Couronne inox Capot supérieur PVC peint avec étiquettes et grille Capot inférieur PVC peint avec étiquettes Cuvette PVC Ecran PVC transparent Miroir inox Joint viton Ø12 Joint PTFE avec âme souple Joint viton Ø19.5 Rodet PTFE 29/32 (paquet de 10) Carte logique avec EPROM programmée S1000 Disquette logiciel avec notice Carte de puissance 200/230V Carte de puissance 100/120V Interrupteur général Ampoule (paquet de 4) avec 2 culots Switch de porte avec levier de commande Condensateur Magnétron avec thermo-contrôleur et bride Résistance de sécurité porte Transformateur filament 200/230V Transformateur filament 100/120V Fusible F1: 12.5 AT 6.3x32 Fusible F1: 15AT 6.3x32 Fusible F2: 1 AT (5x20) (par 10) Fusible F2: 2 AT (5x20) (par 10) Lunette infrarouge Ventilateur Filtre secteur 200/230V Filtre secteur 100/120V Cordon secteur 200/230V Cordon secteur 100/120V 9 TYPE A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A P78 962 02 SPARE PARTS REF CODE 154 146 147 134 135 209 211 213 402 137 403 404 405 406 407 408 138 420 421 425 --500 17239010 17239021 17239076 17239087 17239098 17239112 17239134 17239156 19671610 17239167 19615855 19615866 17239178 17239180 19747678 17239271 17233145 19573121 09838106 19573440 08504287 19514468 17233010 17231503 17231605 19112664 19013161 19073076 19048002 19015032 570 570 520 501 545 593 555 550 506 560 560 578 578 579 579 503 565 535 535 525 525 SYNTHEWAVE 1000 19044783 19181593 19181605 19082727 19082751 19082443 19082454 19671107 19900747 19048946 19048935 19093703 19093510 NAME Chamber Door Module base Main switch support holder Outlet and jack frame Door seal with tightening screws and sheaths Stirrer tightening screw Sealed porthole fixing assembly Porthole (packet of 5) Stainless steel chamber cover with label and window Stainless steel door cover assembly Stainless steel frame retainer Painted PVC top cover with labels and grating Painted PVC bottom cover with labels PVC cuvette Transparent PVC window Miroir Viton seal, Ø12 PTFE seal with flexible core Viton seal, Ø19.5 PTFE 29/32 strap (packet of 10) Logic board with programmed EPROM, S1000 Synsoft floppy disk with user's manuel Power card 200/230V Power card 100/120V Main switch Bulb (packet of 4) with two caps Door switch with control lever Capacitor Magnetron with thermal switch Door safety resistor HV transformer 200/230V HV transformer 100/120V Main fuse F1:12.5 AT 6.35x32 Main fuse F1:15 AT 6.35x32 Fuse F2: 1 AT (5x20) (by 10) Fuse F2: 2 AT (5x20) (by 10) Infra-red lens Fan Main filter 200/230V Main filter 100/120V Main lead (230V version) with grommet Main lead (100/120Vversion) with grommet 10 TYPE A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A P78 962 02