Synthèse organique micro-ondes Organic Microwave

Transcription

Synthèse organique micro-ondes Organic Microwave
54, rue Roger Salengro - BP 115 - 94126 -FONTENAY-SOUS-BOIS CEDEX–
Synthèse organique micro-ondes
Organic Microwave Synthesis
SYNTHEWAVE 1000
NOTICE TECHNIQUE
SERVICE MANUAL
P78962 02
B20546
NOMENCLATURE / REFERENCES
Principaux composants du module micro-ondes SYNTHEWAVE 1000
Main components of the SYNTHEWAVE 1000 microwave module
SYNTHEWAVE 1000
PROLABO
300
302
497
596
301
597
598
304
SYNTHEWAVE 1000
2
P78 962 02
NOMENCLATURE / REFERENCES
REPERE
CODE
497
300
301
302
598
597
596
304
17239327
06402635
06402657
00963143
19093417
19093678
19093667
06402646
REF
CODE
497
300
301
302
598
597
596
304
17239327
06402635
06402657
00963143
19093417
19093678
19093667
06402646
SYNTHEWAVE 1000
DESIGNATION
Cristallisoir inox
Doigt de gant quartz à hublot équipé
Agitateur pour liquides
Bouchons verre 29/32
Cordon RS232
Adaptateur RJ45/SUBD9
Adaptateur RJ45/SUBD25
Réacteur quartz
NAME
Stainless steel crystallizing pan
Quartz glove finger with équipped porthole
Liquid stirrer
Glass stoppers 29/32
RS232 lead
RJ45/SUBD9 pin adaptor
RJ45/SUBD25 pin adaptor
Quartz reactor
3
P78 962 02
TABLEAU DE DIAGNOSTIC
DEFAUTS
Le voyant jaune de
l’interrupteur secteur du
module à micro-ondes ne
s’allume pas
CAUSES POSSIBLES
Fusible secteur F1
endommagé (repère 578)
Voyant défectueux
Problème arrivé secteur
Le voyant vert est éteint, bien La porte de l’appareil n’est
que le voyant jaune soit
pas verrouillée en position
allumé,
affichage à l’écran du
message porte ouverte ou
surchauffe du magnétron.
Un switch de fermeture de
porte est défectueux. (repère
545)
Le thermo-contact de
surchauffe magnétron est
endommagé. (repère 550)
Surchauffe du magnétron:
ventilation commune pour le
magnétron et la carte de
puissance. (repère 565)
Un des 5 swicths de sécurité
porte n’est pas en position
Voyant défectueux
Le voyant vert est allumé
mais le voyant rouge reste
éteint malgré une puissance
micro-onde programmée.
Voyant défectueux
ACTIONS CORRECTIVES
Contrôler la position électrique des switchs de
porte
Changer le fusible F1 (voir chapitres entretien
maintenance et pièces de rechange)
Verrouiller complètement la porte de l’appareil,
si le voyant vert s’allume, faire changer
l’interrupteur.
Vérifier le branchement et l’état du cordon
secteur.Vérifier la tension secteur
Vérifier le bon positionnement de la porte et
manoeuvrer les vis de bridage.
– Si le voyant reste éteint;
Vérifier la commande mécanique des switchs.
La puissance micro-onde est sollicitée,
– Les voyants vert et rouge restent éteints;
Changer le switch de porte, voir le SAV.
Les 2 voyants sont éteints la porte est fermée,
si le voyant vert ne s’allume pas après 5 à 10
minutes d’arrêt;
Changer le thermo-contact, voir le SAV.
Les voyants vert et rouge s’éteignent pendant le
déroulement du programme,
– Dégager les prises d’air autour de l’appareil –
Le S1000 est installé dans une zone chaude.
– Vérifier le fonctionnement du ventilateur;
Changer la ventilation, voir le SAV.
Le fusible F2 est détruit
Contacter le SAV
Lors de la commande de puissance, si le voyant
rouge s’allume, faire changer le voyant vert.
Si le produit chauffe faire changer le voyant
rouge.
La programmation n’est pas
correctement effectuée.
Le voyant vert est allumé,
affichage à l’écran d’un
message: Erreur de
communication
SYNTHEWAVE 1000
Le programme n’a pas démarré,
– Vérifier sur la notice, de l’utilisation correct du
programme.
Mauvais fonctionnement de la Faire appel au service après vente.
carte de puissance
(repère 570)
Le cordon de la liaison RS232 Démonter la trappe sur le coté de l’appareil,
est défectueux. (repère 598)
– Le cordon RS232 est-il branché ?,
– Vérifier le cordon et l’adaptateur sur le PC;
Changer l’élément défectueux.
4
P78 962 02
TABLEAU DE DIAGNOSTIC
DEFAUTS
L’éclairage du guide ne
fonctionne pas, malgré sa
commande actionnée
La température est asservie,
mais la valeur affichée à
l’écran reste inférieure à la
valeur de consigne,
ou la montée en température
est très lente.
La température réelle dans le
matras est plus haute que la
valeur affichée.
SYNTHEWAVE 1000
CAUSES POSSIBLES
ACTIONS CORRECTIVES
Les lampes sont hors d’usage
(repère 501)
Démonter le capotage et le déflecteur (voir
chapitre maintenance)
- vérifier le branchement des lampes, et
remplacer les lampes usagées.
Le produit chauffé est non
Faire un essai avec de l’eau dans le matras en
polaire.
asservissement de température;
– Pour une consigne de 70°C et 300ml d’eau, la
température stabilise en 9 minutes environ.
Programmation en puissance Augmenter la valeur de la puissance maxi.;
trop faible.
– Vérifier que la température monte plus vite.
Le magnétron ne délivre plus Qu’elle que soit la consigne affichée, la montée
la puissance nécessaire.
en température est très lente;
(repère 555)
Changer le magnétron, voir le SAV.
L’écran de renvoi de spot sur Démonter la trappe sous l’appareil,
la zone de mesure est peut– Dévisser l’écran de renvoi de spot,
être souillé.
– Nettoyer l’écran avec de l’alcool et un frotter
(repère 138)
avec un chiffon doux.
La fenêtre du doigt de gant est Démonter la fenêtre du doigt de gant,
souillée. (repère 213+402)
– Nettoyer la fenêtre avec de l’alcool et frotter
avec un chiffon doux.
5
P78 962 02
TROUBLE-SHOOTING
FAULT
The yellow lamp
on the on/off switch
will not come
on.
POSSIBLE CAUSES
CORRECTIVE ACTION
Check the position of électrical swiches of the
door.
Change fuse 1(see maintenance and spare part
chapters)
Indicator failure
Completely close the instrument door, if the
green indicator lights up, change the main switch
There is a problem on the
If the green lamp remains off,
mains feed
check the connection of the main lead, the state
of the lead, and the main voltage.
The green lamp is off, even
The door of the apparatus is
Check the proper position of the door and turn
though the yellow lamp is on, not locked in position
the
and a screen
clamping screws.
- If the signal lamp is still off, check the
mechanical control of the switch .
The microwave power is being drawn used, but
message says "Door open or The door-closing switch is
faulty (Ref. 545)
the red and green lamps remain off. Change the
magnetron overheating".
door switch or consult the after-sales service.
The thermal contact on the
Both lamps are off though the door is closed. If
magnetron is damaged
the lamp does not come on after 5 minutes at a
(Ref. 550).
halt, then change the thermal contact or consult
the after-sales service.
Overheating of magnetron:the The green and red lamps go off while the
ventilation is the same for the program is running.
magnetron and the power
– Clear the air intakes around the instrument,
supply board.(ref.565)
– the S1000 has been located in an excessively
hot area.
– Check the operation of the fans.
Change the ventilation components or consult the
after-sales service.
One of the door’s 5 safety
Fuse F2 is destroyed: contact the after sales
switches is not in position.
service.
Indictor failure
During a power command, if the red indicator
lights up, change the green indicator.
The green lamp is on, but the Indicator failure
If the product heats, change the red indicator
red lamp stays off even
though microwave heating
has been programmed.
Programming has not been
The program has not started up.
done correctly
Check with the operating instructions for correct
execution of the program.
Malfunction of digester
Call the after-sales service
power board (ref: 570)
The green lamp is on, and a
The RS232 lead is faulty
Remove the cover at the right side of the
(Ref. 598)
instrument.
"Transmission problem"
- Is the RS232 lead connected?
message appears on the
- Check the lead and the connector on the
screen.
computer. Change any faulty parts.
SYNTHEWAVE 1000
F1 main fuse dammaged
(ref:578)
6
P78 962 02
TROUBLE-SHOOTING
FAULT
POSSIBLE CAUSES
Guide lighting is not
working,even though its
control has been operated
The lamps has blown
(ref:501)
The temperature is being
controlled, but the value
displayed on the screen
remains below that of the
setpoint, or the temperature
rise is very slow
The substance being heated is
non-polar.
The actual temperature in the
flask is higher than the value
displayed.
SYNTHEWAVE 1000
The programmed power is too
low.
The magnetron is not
delivering the required power
(Ref. 555)
The window for spot
transmission to the
measurement zone may be
dirty (Ref. 138)
The window of the glove
finger is dirty (Ref. 213+402)
7
CORRECTIVE ACTION
Remove the covering and the deflector (see
maintenance chapter).
-Check the connection of the bulbs, and replace
used bulbs.
Do a test with water in the flask and controlling
the temperature. For a setpoint of 70°C and 300
ml of water, the temperature should stabilise
within about 9 minute.
Increase the maximum power value.
Check that the temperature rises faster.
Whatever the setpoint displayed, the temperature
rise is very slow. Change the magnetron, and
finally consult the after-sales service.
Remove the cover on the bottom of the
instrument. Unscrew the spot transmission
screen. Clean this screen wit alcohol and wipe it
with a soft cloth.
Remove the window of the glove finger. Clean
the window with alcohol, and wipe it with a soft
cloth.
P78 962 02
SCHEMAS ECLATES / EXPLODED VIEWS
146
420
209
421
501
405
154
SYNTHEWAVE 1000
PROLABO
213+402
134
407
520
147
406
138
503
545
404
593
506
560
137
565
408
555
550
500
211
403
570
579
578
535
525
135
SYNTHEWAVE 1000
8
P78 962 02
PIECES DE RECHANGE
REPERE
CODE
154
146
147
134
135
209
211
213
402
137
403
404
405
406
407
408
138
420
421
425
--500
17239010
17239021
17239076
17239087
17239098
17239112
17239134
17239156
19671610
17239167
19615855
19615866
17239178
17239180
19747678
17239271
17233145
19573121
09838106
19573440
08504287
19514468
17233282
17231503
17231605
19112664
19013161
19073076
19048002
19015032
570
570
520
501
545
593
555
550
506
560
560
578
578
579
579
503
565
535
535
525
525
SYNTHEWAVE 1000
19044783
19181593
19181605
19082727
19082751
19082443
19082454
19671107
19900747
19048946
19048935
19093703
19093510
DESIGNATION
Cavité
Porte
Platine
Support interrupteur général avec polyester
Carénage de prises+ embase jack
Joint de porte avec vis de serrage et gaines
Vis de serrage agitateur
Fixation hublot étanche
Hublot ZnSe Ø19x2 (paquet de 5)
Capot de cavité inox avec étiquette et écran
Capot de porte inox équipé
Couronne inox
Capot supérieur PVC peint avec étiquettes et grille
Capot inférieur PVC peint avec étiquettes
Cuvette PVC
Ecran PVC transparent
Miroir inox
Joint viton Ø12
Joint PTFE avec âme souple
Joint viton Ø19.5
Rodet PTFE 29/32 (paquet de 10)
Carte logique avec EPROM programmée S1000
Disquette logiciel avec notice
Carte de puissance 200/230V
Carte de puissance 100/120V
Interrupteur général
Ampoule (paquet de 4) avec 2 culots
Switch de porte avec levier de commande
Condensateur
Magnétron avec
thermo-contrôleur et bride
Résistance de sécurité porte
Transformateur filament 200/230V
Transformateur filament 100/120V
Fusible F1: 12.5 AT 6.3x32
Fusible F1: 15AT 6.3x32
Fusible F2: 1 AT (5x20) (par 10)
Fusible F2: 2 AT (5x20) (par 10)
Lunette infrarouge
Ventilateur
Filtre secteur 200/230V
Filtre secteur 100/120V
Cordon secteur 200/230V
Cordon secteur 100/120V
9
TYPE
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
P78 962 02
SPARE PARTS
REF
CODE
154
146
147
134
135
209
211
213
402
137
403
404
405
406
407
408
138
420
421
425
--500
17239010
17239021
17239076
17239087
17239098
17239112
17239134
17239156
19671610
17239167
19615855
19615866
17239178
17239180
19747678
17239271
17233145
19573121
09838106
19573440
08504287
19514468
17233010
17231503
17231605
19112664
19013161
19073076
19048002
19015032
570
570
520
501
545
593
555
550
506
560
560
578
578
579
579
503
565
535
535
525
525
SYNTHEWAVE 1000
19044783
19181593
19181605
19082727
19082751
19082443
19082454
19671107
19900747
19048946
19048935
19093703
19093510
NAME
Chamber
Door
Module base
Main switch support holder
Outlet and jack frame
Door seal with tightening screws and sheaths
Stirrer tightening screw
Sealed porthole fixing assembly
Porthole (packet of 5)
Stainless steel chamber cover with label and window
Stainless steel door cover assembly
Stainless steel frame retainer
Painted PVC top cover with labels and grating
Painted PVC bottom cover with labels
PVC cuvette
Transparent PVC window
Miroir
Viton seal, Ø12
PTFE seal with flexible core
Viton seal, Ø19.5
PTFE 29/32 strap (packet of 10)
Logic board with programmed EPROM, S1000
Synsoft floppy disk with user's manuel
Power card 200/230V
Power card 100/120V
Main switch
Bulb (packet of 4) with two caps
Door switch with control lever
Capacitor
Magnetron with
thermal switch
Door safety resistor
HV transformer 200/230V
HV transformer 100/120V
Main fuse F1:12.5 AT 6.35x32
Main fuse F1:15 AT 6.35x32
Fuse F2: 1 AT (5x20) (by 10)
Fuse F2: 2 AT (5x20) (by 10)
Infra-red lens
Fan
Main filter 200/230V
Main filter 100/120V
Main lead (230V version) with grommet
Main lead (100/120Vversion) with grommet
10
TYPE
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
P78 962 02