Protocoles de test SNAP
IDEXX SNAP* Residue Tests Accurate residue detection in 10 minutes or less SNAP Test Drug Detection Test New SNAP Beta-Lactam * Drug Name brand penicillin G Albacillin*, ALBADRY PLUS*, Aqua-Mast II, Benza-Pen, Combicillin*, Combi-Pen-48*, Crysticillin, Flo-cillin*/Dura-biotic, Hanford/US Vet Han-Pen* B (or G), Hanford/US Vet Ultrapen, Hanford/US Vet Masti-Clear*, Microcillin, Norocillin*, Pen BP-48*, PFI-Pen G, PEN-G MAX*, Pro-Pen-G*, Procaine G penicillin, Special Formula 17900-Forte* Suspension, Quartermaster*, Heticin-K amoxicillin Amoxi-Bol, Amoxi-Inject*, Amoxi-Mast* ampicillin Polyflex*, Princillin bolus ceftiofur Excede*, Excenel*, NAXCEL*, Spectramast* DC, Spectramast* LC cephapirin Cefa-Dri*, Cefa-Lak*, ToDAY*, ToMORROW* tetracycline Panmycin* bolus, Polyotic* tablets, Polyotic* powder, Tet-Sol*, Tetra-Bac*, TetraMed*, Solu-Tet* 324, Tetracycline HCL soluble powder chlortetracycline Aureomycin*, Aureo S 700*, CLTC* 100 MR, Chlormax*, Pennchlor* oxytetracycline Agricyl, Agrymycin, Bio-mycin*, Geomycin, Liquamycin*, Maxim-200*, Medamycin*, Neo-Oxy, Neo-Terramycin*, Oxy calf bolus, OXTC*, Oxy-Tet*, Oxytetracycline HCL soluble powder, Oxyshot*, Pennox*, Promycin*, Terramycin*, Tetradure*, Tetroxy* Status SQ, LA-200* SNAP* Aflatoxin M1 aflatoxin M1 May be found in milk or milk products obtained from livestock that have ingested contaminated feed. SNAP* Gentamicin gentamicin Residues may be found in milk after the intramammary treatment of lactating cows for mastitis. SNAP* Sulfamethazine sulfamethazine Aureo* S 700 G, SulfaSure*, Sulmet*, Sustain III* SNAP* Tetracycline SNAP* Residue Tests Before you begin Test Procedure •Work space must be clean and free of drug residues. •Preheat heater block to 45°C ±5°C (113°F ±9°F). •Place SNAP device on heater block; leave on heater block for duration of test. •Make sure conjugate pellet is at the bottom of the sample tube. If not, tap tube gently to return pellet to the bottom. •Agitate the milk sample thoroughly. 1 Note: •Accurate incubation times and temperatures are essential. •Do not use a SNAP test after its expiration date. •Refer to package insert for complete instructions. Prepare sample sing pipette, draw up U milk to indicator line (450 µL ±50 µL).† Add milk to sample tube. Gently shake tube sideto-side 3–4 times to dissolve reagent pellet. Place tube on heater block and incubate: Beta-Lactam Tetracycline 5 minutes Aflatoxin M1 2 Gentamicin minutes Sulfamethazine 2 Run test Pour entire contents of sample tube into sample well of SNAP* device. Activation circle 3 Too early Snap Too late As the edge of the activation circle begins to disappear, press down firmly until you hear a distinct “snap.” If activation takes more than 60 seconds, result may be inaccurate.‡ Incubate device: Negative Sample spot is darker than or equal to control spot. No drug residue detected. Positive Sample spot is lighter than control spot. Drug residue detected. Beta-Lactam Tetracycline 4 minutes Aflatoxin M1 7 Gentamicin minutes Sulfamethazine Read results Read results within 30 seconds after incubation, either visually or using the SNAPshot* DSR Reader. Control spot Sample spot IDEXX SNAP tests are backed by a dedicated team of technical service professionals. If you have questions, call IDEXX Technical Services at 1-800-321-0207. †NCIMS-certified ‡A laboratories must use a calibrated pipette. slow flow rate may be caused by a thick sample or by using less than 450 μL of sample. © 2012 IDEXX Laboratories, Inc. All rights reserved. *SNAP and SNAPshot are registered trademarks of IDEXX Laboratories, Inc. or its affiliates in the United States and/or other countries. All other product and company names and logos are trademarks of their respective holders. The IDEXX Privacy Policy is available at idexx.com. Control spot Sample spot IDEXX Tests SNAP* de détection des résidus Détection précise de résidus en 10 minutes ou moins Tests SNAP de détection des médicaments Test Médicament Marque pénicilline G Albacilin*, ALBADRY PLUS*, Aqua-Mast II, Benza-Pen, Combicillin*, Combi-Pen-48*, Crysticillin, Flo-cillin*/Dura-biotic, Hanford/US Vet Han-Pen* B (ou G), Hanford/US Vet Ultrapen, Hanford/US Vet Masti-Clear, Microcillin, Norocillin, Pen BP-48*, PFI-Pen G, PEN-G MAX*, Pro-Pen-G*, Procaine G penicillin, Special Formula 17900-Forte* Suspension, Quartermaster*, Heticin-K amoxicilline Amoxi-Bol, Amosi-Inject*, Amoxi-Mast* ampicilline Polyfex*, Princillin bolus ceftiofur Excede*, Excenel*, NAXCEL*, Spectramast* DC, Spectramast* LC céfapirine Cefa-Dri*, Cefa-Lak*, ToDAY*, ToMORROW* tétracycline Panmycin* bolus, comprimés Polyotic*, poudre Polyotic*, Tet-Sol*, Tetra-Bac*, TetraMed*, Solu-Tet* 324, poudre soluble Tetracycline HCL chlortétracycline Aureomycin*, Aureo*-S-700, CLTC* 100 MR, Chlormax*, Pennchlor* oxytétracycline Agricyl, Agrymycin, Bio-mycin*, Geomycin, Liquamycin*, Maxim-200*, Medamycin*, Neo-Oxy, Neo-Terramycin*, Oxy calf bolus, OXTC*, Oxy-Tet, poudre soluble Oxytetracycline HCL, Oxyshot*, Pennox*, Promycin*, Terramycin*, Tetradure*, Tetroxy* Status SQ, LA-200* SNAP* Aflatoxin M1 aflatoxine M1 Peut être trouvée dans le lait ou les produits laitiers chez le bétail ayant ingéré des aliments contaminés. SNAP* Gentamicin gentamicine Des résidus peuvent être trouvés dans le lait des vaches laitières en lactation après traitement intramammaire en cas de mammites. SNAP* Sulfamethazine sulfaméthazine Aureo* S-700G, SulfaSure*, Sulmet*, Sustain III* New SNAP Beta-Lactam * SNAP* Tetracycline Tests de détection des résidus SNAP* Procédure des tests 1 Préparer l’échantillon Avant de commencer •L’espace de travail doit être propre, sans résidus de médicaments. •Préchauffez le thermobloc à 45° C ± 5° C (113° F ± 9° F). •Placez le dispositif SNAP sur le thermobloc; laissez-le sur le thermobloc pendant le test. •Assurez-vous que les granulés du conjugué se trouvent au fond du tube à échantillon. Si non, tapotez doucement sur le tube pour que les granulés du conjugué retournent au fond. •Agitez bien l’échantillon de lait. À l’aide d’une pipette, aspirez du lait jusqu’à la ligne d’indication (450 µL ± 50 µL).† Ajoutez du lait dans le tube à échantillon. 2 Secouez doucement le tube d’un côté à l’autre 3 à 4 fois jusqu’à ce que les granulés du réactif soient dissous. Note : • Il est essentiel que le temps et la température d’incubation soient exacts. • N’utilisez pas un test SNAP après sa date d’expiration. • Consultez la notice sur l’emballage pour des instructions détaillées. Placez le tube sur le thermobloc et incubez : Beta-Lactam Tetracycline 5 minutes Aflatoxin M1 2 Gentamicin minutes Sulfamethazine Effectuer le test Versez la totalité du tube à échantillon dans le puits d’échantillon du dispositif SNAP*. Cercle d’activation 3 Trop vite Snap Trop tard Lorsque le bord du cercle d’activation commence à disparaître, appuyez fermement jusqu’à ce que vous entendiez distinctement un « clic ». Si l’activation prend plus de 60 secondes, les résultats peuvent être inexacts.‡ Incubate device: Négatif La couleur de la zone de lecture de l’échantillon est égale à ou plus foncée que la couleur du contrôle. Aucun résidu de médicament détecté. Positif La couleur de la zone de lecture de l’échantillon est plus pâle que celle du contrôle. Des résidus de médicament ont été détectés. Beta-Lactam Tetracycline 4 minutes Aflatoxin M1 7 Gentamicin minutes Sulfamethazine Lire les résultats Lisez les résultats dans les 30 secondes suivant l’incubation, soit visuellement ou en utilisant le lecteur SNAPshot* DSR. Contrôl Échantillon Une équipe de professionnels de notre service technique est à votre disposition si vous avez des questions au sujet des tests SNAP d’IDEXX. N’hésitez pas à téléphoner au service technique d’IDEXX, au 1-800-321-0207. †Les ‡Un laboratoires certifiés NCIMS doivent utiliser une pipette calibrée. écoulement lent peut être dû à un échantillon épais ou à l’utilisation de moins de 450 μL d’échantillon. © 2012 IDEXX Laboratories, Inc. Tous droits réservés. • 09-80253-01 *SNAP et SNAPshot sont des marques déposées de IDEXX Laboratories, Inc. ou de ses filiales aux États-Unis et/ou dans d’autres pays. Les autres noms de sociétés, de produits ainsi que les logos reproduits dans ce document appartiennent à leurs détenteurs respectifs. La politique d’IDEXX en matière de confidentialité est disponible sur idexx.com. Contrôl Échantillon