Mise en page 1

Transcription

Mise en page 1
Collectif murales 2014_Mise en page 1 19/02/14 15:39 Page10
10 Chaudières murales
MURALES
Collectif murales 2014_Mise en page 1 19/02/14 15:39 Page11
Luna ST HTE
Initia Plus HTE
Luna Platinum HTE
Sommaire
- Guide de choix
- Luna Platinum Duo HTE 3.24 - 3.33
- Luna Platinum Max HTE 2.28 - 2.33
- Luna Platinum HTE 2.24 - 2.33
- Luna Platinum HTE 1.12 - 1.24
- Initia Plus Duo HTE 3.24 - 3.33
- Initia Plus Max HTE 2.24 - 2.28
- Initia Plus HTE 2.24 - 2.28 - 2.33
- Initia Plus Compact HTE 2.24 - 2.28 - 2.33
- Initia Plus HTE 1.12 - 1.24- 1.28
- Accessoires de régulation
- Composition
12
14
16
18
20
22
24
26
28
30
32
42
- Guide de choix
- Luna ST HTE 2.28
- Luna ST Duo 3.24 CF - VMC/ 3.28 FF
- Luna ST Max 2.24 CF- VMC- FF
- Luna ST Compact 2.24 CF - VMC - FF
- Luna ST Flirt 2.24 CF - VMC - FF
- Luna ST Prime 1.24 CF-FF
- Accessoires
- Composition
44
46
48
50
52
54
56
58
60
Chaudières murales 11
Collectif murales 2014_Mise en page 1 19/02/14 15:39 Page12
GUIDE DE CHOIX
INITIA Plus
Accumulation
Mini-accumulation
Micro-accumulation
Initia Plus
Luna Platinum
Initia Plus HTE
2.24 - 2.28 - 2.33
Luna Platinum HTE
2.24 - 2.33
Initia Plus Compact HTE
2.24 - 2.28 - 2.33
Initia Plus Max HTE
Luna Platinum Max HTE
2.24 - 2.28
2.28 - 2.33
Initia Plus Duo HTE
Luna Platinum Duo HTE
3.24 - 3.33
3.24 - 3.33
Initia Plus HTE
Luna Platinum HTE
1.12 - 1.24 - 1.28
1.12 - 1.24
* Crédit d’impôts sous réserve de la Loi de Finances en vigueur.
12 Chaudières murales
/ LUNA Platinum
Collectif murales 2014_Mise en page 1 19/02/14 15:39 Page13
ÉLIGIBLE
solution
Au crédit
d’impôt*
COMPTAGE D’ÉNERGIE
DISPONIBILITÉ AVRIL 2014, NOUS CONSULTER
selon norme EN13203
Initia Plus HTE :
Initia Plus Compact HTE
Luna Platinum HTE
Confort sanitaire :
Chaudière gaz, chauffage et ECS à microaccumulation avec gestion électronique de la
température du corps de chauffe et de consommation
ECS.
selon norme EN13203
Initia Plus Max HTE :
Luna Platinum Max HTE
Confort sanitaire :
MURALES
Confort sanitaire :
Chaudière gaz, chauffage et eau chaude à mini
accumulation.
Débit d’eau chaude exceptionnel (jusqu’ à 16.3 l / mn)
immédiatement disponible, le système breveté
“Dynamic Max” permet en effet d’atteindre en moins
de 5 secondes le niveau de température souhaité et
un niveau de confort inégalé
selon norme EN13203
Initia Plus Duo HTE :
Luna Platinum Duo HTE
Chaudière gaz, chauffage et eau chaude sanitaire à
accumulation.
Performances élevées pour plus d’économies
(rendement optimal).
L’eau chaude en abondance pour un espace occupé
minimum.
Stabilité de température pour répondre aux exigences de
confort.
Chaudières murales 13
Collectif murales 2014_Mise en page 1 19/02/14 15:39 Page14
LUNA PLATINUM Duo
3.24 - 3.33
solution
COMPTAGE D’ÉNERGIE
DISPONIBILITÉ AVRIL 2014, NOUS CONSULTER
AVANTAGES
PRODUIT
} Chauffage et ECS
} Accumulation
} Condensation
} Puissance de 2,4 à 33 kW
Solution
PMR
} Plage de régulation de 10 à 100%
} Pompe modulante
} Régulation complète déportable
} Affichage avec menu déroulant
} Système Gaz Adaptive Control
} Solaire compatible
} Sonde extérieure de série
Contrôle permanent de la combustion et gestion de
la vanne gaz pour un rendement optimal
Luna Platinum Duo HTE
avec option récepteur 5 LED
Régulation déportable Luna Platinum Duo HTE (voir
options accessoires de régulation page 32)
Caractéristiques techniques
LUNA PLATINUM DUO HTE
Type de générateur
Type de chaudière
Energie
Evacuation
Plage de puissance
kW
Puissance nominale chauffage 80/60 °C
kW
Puissance utile intermédiaire
kW
Rendement charge mini et 30°C
%
Rendement charge 30 % et 30°C
%
Rendement charge 100 % et 70°C
%
C
°C
H Plage de température chauffage
A
W
U Puissance électrique des auxiliaires hors circulateur à Pmin
F Puissance électrique des auxiliaires hors circulateur à Pn
W
F Type de circulateur
A
G Puissance circulateur maxi
W
E
Puissance circulateur mini
W
Puissance circulateur RT 2012
W
Débit minimal
l/h
Pertes à l'arrêt ∆T 30
W
Puissance électrique à charge nulle (veille)
W
Puissance nominale sanitaire sur PCI
kW
Débit spécifique à ∆T 30
L/min
Classification EN 13203
S Constante de refroidissement (justifiée)
Wh/K.l.24h
A
W
N Pertes à l'arrêt du ballon ∆T 45
I Temps de réchauffage
mn
T
A Débit soutirable en 10 mn
I Capacité de stockage
l
R
°C
E Température maxi ballon
Hauteur relative serpentin
Hystérésis du ballon
N° Zone du thermostat
Pression acoustique à 1 m Pmin
dB(A)
Poids
kg
Données
RT 2012
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
3.24
Accumulation
Condensation
Gaz naturel ou propane
Ventouse - Cheminée C13, C33, C43, C43P*, C53, C63, C83, B23, B23p, C93
2,4-24
3,3-33
20
28
6
8,4
108,5
108,5
108
108
97,7
97,7
25/80
25/80
15
15
60
70
vitesse variable et pression différentielle variable
70
70
35
35
53
53
0
0
58
61
4,1
4,1
24
33
16,6
19,5
***
***
0,78
0,78
64
64
10
10
166
200
40
40
80
80
0,7
0,7
5
5
1
1
35,5
34,7
62
64
Valeurs actualisées disponibles sur le site d'Uniclima: www.rt2012-chauffage.com - *Avec accessoire coude 3CEP page 38
14 Chaudières murales
3.33
Schéma de principe
13
16
17
18
19
20
21
22
23
12
24
25
11
FOURNITURES STANDARD
Chaudière à accumulation et
à condensation.
• Équipée d’une chambre de
combustion et échangeur spirale en
inox (316 L),
• Modulation intégrale de la puissance
entre 10 et 100 %,
• Tirage flux forcé et cheminée type
B.23,
• Fonctionnement au gaz naturel avec
possibilité de transformation au GPL.
• Filtre chauffage intégré et visitable
permet de protéger le corps de
chauffe.
FONCTIONNEMENT
EN ECS, MODÈLE LUNA
PLATINUM Duo HTE
• Mise en température du ballon. La
sonde CTN contrôle la température
du ballon et assure la priorité au
réchauffage de l’échangeur immergé
(serpentin) par mise en service de la
pompe chauffage et basculement de
la vanne 3 voies,
• Le contrôle de température ECS est
assuré par 1 sonde sanitaire CTN.
25
26
27
14
10
28
29
30
15
31
C
1
9
A
B
8
7 6
5 4
D
E 3
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
2 F
24
25
Caractéristique de la pompe de circulation
basse consommation
La pompe modulante utilisée est de grande hauteur manométrique et
convient sur n’importe quel type d’installation de chauffage monotube
ou bitube.
Le dégazeur incorporé dans le corps de la pompe permet une purge
rapide de l’installation de chauffage.
26
27
28
29
30
31
A
B
C
Luna Platinum Duo HTE 3.24 / 3.33
Raccordements
hydrauliques
D
E
F
Vanne gaz
Manomètre
By-pass automatique
Filtre retour chauffage
Pompe avec séparateur
d’air
Vase d’expansion ECS
Soupape de sécurité ECS
(8 bars)
Limiteur de débit
Robinet de vidange
ballon
Sonde ballon ECS
Ballon (40 litres)
Échangeur ECS ballon
Anode sacrificielle ballon
Robinet de remplissage
chaudière
Disconnecteur
Vase d’expansion
Sonde fumées
Raccord coaxial
Échangeur eau-fumées
Électrode d’allumage
Brûleur
Collecteur mélange airgaz
Électrode de détection de
flamme
Thermostat de sécurité
Sonde chauffage
(dép./ret.)
Ventilateur
Venturi air/gaz
Pressostat hydraulique
Soupape de sécurité
chauffage (3 bars)
Vanne trois voies
motorisée
Robinet de vidange
chaudière
Sortie eau chaude
sanitaire/Ballon
Entrée eau froide
sanitaire
Siphon avec évacuation
des condensats
Retour eau de chauffage
Départ eau de chauffage
Entrée GAZ
Dimensions
Ø 60/100
MR : départ chauffage
US : sortie eau chaude
sanitaire
GR : entrée gaz dans la
chaudière
ES : entrée eau froide
sanitaire
RR : retour installation
de chauffage
Référence
Prix € HT
Luna Platinum Duo 3.24 HTE H
Modèle
CLUP324HT
3 267
Luna Platinum Duo 3.24 HTE V
CLUP324HV
3 208
Luna Platinum Duo 3.33 HTE H
CLUP333HT
3 532
Luna Platinum Duo 3.33 HTE V
CLUP333HV
3 473
Chaudières murales 15
MURALES
Collectif murales 2014_Mise en page 1 19/02/14 15:39 Page15
Collectif murales 2014_Mise en page 1 19/02/14 15:39 Page16
LUNA PLATINUM Max
2.28 - 2.33
solution
COMPTAGE D’ÉNERGIE
DISPONIBILITÉ AVRIL 2014, NOUS CONSULTER
AVANTAGES
PRODUIT
}
}
}
}
} Plage de régulation de 10 à 100%
} Pompe modulante
} Régulation complète déportable
} Affichage avec menu déroulant
Solution
PMR
Chauffage et ECS
Mini-accumulation
Condensation
Puissance de 2,4 à 33 kW
} Système Gaz Adaptive Control
} Solaire compatible
} Sonde extérieure de série
Contrôle permanent de la combustion et gestion de
la vanne gaz pour un rendement optimal
Régulation déportable Luna Platinum Max HTE
(voir options accessoires de régulation page 32)
Caractéristiques techniques
Données
RT 2012
●
LUNA PLATINUM MAX HTE
Type de générateur
Type de chaudière
Energie
Evacuation
Plage de puissance
Puissance nominale chauffage 80/60 °C
Puissance utile intermédiaire
Rendement charge mini et 30°C
Rendement charge 30 % et 30°C
C Rendement charge 100 % et 70°C
H Plage de température chauffage
A
U Puissance électrique des auxiliaires hors circulateur à Pmin
F Puissance électrique des auxiliaires hors circulateur à Pn
F
A Type de circulateur
G Puissance circulateur maxi
E
Puissance circulateur mini
Puissance circulateur RT 2012
Débit minimal
Pertes à l'arrêt ∆T 30
Puissance électrique à charge nulle (veille)
Puissance nominale sanitaire sur PCI
Débit spécifique à ∆T 30
Classification EN 13203
Pression acoustique à 1 m Pmin
Poids
S
A
N
I
T
A
I
R
E
kW
kW
kW
%
%
%
°C
W
W
W
W
W
l/h
W
W
kW
L/min
●
●
●
●
●
●
●
●
●
●
dB(A)
kg
Valeurs actualisées disponibles sur le site d'Uniclima: www.rt2012-chauffage.com
*Avec accessoire coude 3CEP page 38
16 Chaudières murales
2.28
2.33
Mini-accumulation
Condensation
Gaz naturel ou propane
Ventouse - Cheminée C13, C33, C43, C43P*, C53, C63, C83, B23, B23p, C93
2,8-28
3,3-33
24
28
7,2
8,4
108,5
108,5
108
108
97,6
97,6
25/80
25/80
15
15
65
75
vitesse variable et pression différentielle variable
70
70
35
35
53
53
0
0
35
40
4,1
4,1
28
33
14,5
16,8
***
***
33,7
34,3
38,5
39,5
Collectif murales 2014_Mise en page 1 19/02/14 15:39 Page17
1 Pompe avec
18
19
17
20
2
3
4
21
5
22
23
6
7
16
24
FOURNITURES STANDARD
• Chaudière murale à
mini-accumulation.
• Équipée d’une chambre de
combustion et échangeur spirale en
inox (316 L),
• Modulation intégrale de la puissance
entre 10 et 100 %,
• Tirage flux forcé (FF) et cheminée
B.23,
• Fonctionnement au gaz naturel avec
possibilité de transformation au GPL.
FONCTIONNEMENT
EN ECS
La chaudière dispose d'une réserve
d'énergie primaire stockée dans le
vase d'expansion, un système de
priorité contrôle régulièrement la
température de ce stockage par une
vanne de priorité. Lors d'un puisage
sanitaire, les vannes de priorité
enclenchent la circulation sur le vase
d'expansion et l'échangeur à plaques.
La montée en température de l'eau
chaude sanitaire se fait immédiatement
(< 5 secondes).
La température de l'eau chaude est
contrôlée par 2 sondes CTN (chauffage
et eau chaude) afin de garantir une
parfaite stabilité de la température
d'eau en agissant sur l'ouverture
modulante de la vanne gaz.
La stabilité de température est
maintenue constante en cas de
puisages simultanés grâce à la
capacité en eau du système.
16
15
14
13
25
12
11
1
8
9
10
11
12
13
14
15
16
17
séparateur d’air
Robinet de vidange
chaudière
Manomètre
Soupape de sécurité 3
bars
Robinet de remplissage
installation
Filtre sanitaire et
limiteur de débit
Capteur de priorité
sanitaire
Sonde sanitaire
Pressostat hydraulique
Vanne trois voies
motorisée
Clapet anti-retour
Echangeur sanitaire
Vanne gaz
Vase d’expansion
Thermostat de sécurité
Sonde chauffage
Sonde fumées
18
19
20
21
22
Raccord coaxial
Echangeur eau-fumées
Electrode d’allumage
Brûleur
Electrode de détection
de flamme
23 Collecteur mélange airgaz
24 Ventilateur
25 Venturi
A Siphon avec évacuation
des condensats
Équipement disponible en
tant qu’accessoire :
B Robinet départ eau de
chauffage
C Sortie eau chaude
sanitaire/Ballon
D Robinet entrée GAZ
E Robinet entrée eau
froide sanitaire
F Robinet retour eau
chauffage
M
2
10
9 8
A B
7 6
C D
5
E
F
4
Raccordements hydrauliques
3
MR : départ chauffage
US : entrée eau chaude
sanitaire
GAS : entrée gaz dans la
chaudière
ES : entrée eau froide
sanitaire
RR : retour installation
de chauffage
Caractéristique de la pompe de circulation basse consommation
La pompe modulante utilisée est de grande hauteur manométrique et convient sur n’importe
quel type d’installation de chauffage monotube ou bitube. Le dégazeur incorporé dans le corps
de la pompe permet une purge rapide de l’installation de chauffage.
Luna Platinum Max HTE 2.28 / 2.33
Ø 60/100
Dimensions
Référence
Prix € HT
Luna Platinum Max 2.28 HTE H
Modèle
CLUPM228HT
2 851
Luna Platinum Max 2.28 HTE V
CLUPM228HV
2 792
Luna Platinum Max 2.33 HTE H
CLUPM233HT
3 051
Luna Platinum Max 2.33 HTE V
CLUPM233HV
2 992
Chaudières murales 17
MURALES
Schéma de principe
Collectif murales 2014_Mise en page 1 19/02/14 15:39 Page18
LUNA PLATINUM
2.24 - 2.33
solution
COMPTAGE D’ÉNERGIE
DISPONIBILITÉ AVRIL 2014, NOUS CONSULTER
AVANTAGES
PRODUIT
Solution
PMR
} Plage de régulation de 10 à 100%
} Pompe modulante
} Régulation complète déportable
} Affichage avec menu déroulant
}
}
}
}
Chauffage et ECS
Micro-accumulation
Condensation
Puissance de 2,4 à 33 kW
} Système Gaz Adaptive Control
} Solaire compatible
} Sonde extérieure de série
Contrôle permanent de la combustion et gestion de
la vanne gaz pour un rendement optimal
Régulation déportable Luna Platinum HTE
(voir options accessoires de régulation page 32)
Caractéristiques techniques
Données
RT 2012
●
LUNA PLATINUM HTE
Type de générateur
Type de chaudière
Energie
Evacuation
Plage de puissance
Puissance nominale chauffage 80/60 °C
Puissance utile intermédiaire
Rendement charge mini et 30°C
Rendement charge 30 % et 30°C
C Rendement charge 100 % et 70°C
H Plage de température chauffage
A
U Puissance électrique des auxiliaires hors circulateur à Pmin
F Puissance électrique des auxiliaires hors circulateur à Pn
F
A Type de circulateur
G Puissance circulateur maxi
E
Puissance circulateur mini
Puissance circulateur RT 2012
Débit minimal
Pertes à l'arrêt ∆T 30
Puissance électrique à charge nulle (veille)
Puissance nominale sanitaire sur PCI
Débit spécifique à ∆T 30
Classification EN 13203
Pression acoustique à 1 m Pmin
Poids
S
A
N
I
T
A
I
R
E
kW
kW
kW
%
%
%
°C
W
W
W
W
W
l/h
W
W
kW
L/min
●
●
●
●
●
●
●
●
●
●
dB(A)
kg
Valeurs actualisées disponibles sur le site d'Uniclima: www.rt2012-chauffage.com
*Avec accessoire coude 3CEP page 38
18 Chaudières murales
2.24
2.33
Micro accumulation
Condensation
Gaz naturel ou propane
Ventouse - Cheminée C13, C33, C43, C43P*, C53, C63, C83, B23, B23p, C93
2,4-24
3,3-33
20
28
6
8,4
108,5
108
97,7
97,6
25/80
15
50
75
vitesse variable et pression différentielle variable
70
35
53
0
35
40
4,1
24
33
12,1
16
***
35,1
34,3
38,5
39,5
Collectif murales 2014_Mise en page 1 19/02/14 15:39 Page19
1 Pompe avec
17
18
16
19
20
2
3
4
5
21
22
6
7
15
23
15
FOURNITURES STANDARD
Chaudière murale à condensation
micro accumulée.
• Équipée d’une chambre de
combustion et échangeur spirale en
inox (316 L),
• Modulation intégrale de la puissance
entre 10 et 100 %,
• Tirage flux forcé et cheminée B.23,
• Fonctionnement au gaz naturel avec
possibilité de transformation au GPL.
• Filtre chauffage intégré et visitable
permettant de protéger le corps de
chauffe.
24
14
25
13
12
11
1
M
10
2
9 8
A B
7 6
C D
5
E
4
8
9
10
11
12
13
14
15
16
17
18
19
20
21
Echangeur eau-fumées
Electrode d’allumage
Brûleur
Electrode de détection
de flamme
22 Collecteur mélange airgaz
23 Ventilateur
24 Venturi
25 Vase d’expansion
A Siphon avec
évacuation des
condensats
Équipement disponible en
tant qu’accessoire :
B Robinet départ eau de
chauffage
C Sortie eau chaude
sanitaire/Ballon
D Robinet entrée GAZ
E Robinet entrée eau
froide sanitaire
F Robinet retour eau
chauffage
Raccordements hydrauliques
3
F
DESCRIPTIF DU
PRINCIPE DE LA MICRO
ACCUMULATION
Le système de gestion électronique de
Luna Platinum HTE permet de
maintenir en température le système de
production d’eau chaude durant les
périodes de puisage.
Le système peut être modifié par
l’utilisateur pour passer en mode “eco”.
L’eau chaude arrive rapidement et à
température constante.
séparateur d’air
Robinet de vidange
chaudière
Manomètre
Soupape de sécurité 3
bars
Robinet de
remplissage
installation
Filtre sanitaire et
limiteur de débit
Capteur de priorité
sanitaire
Sonde sanitaire
Pressostat hydraulique
Vanne trois voies
motorisée
Clapet anti-retour
Echangeur sanitaire
Vanne gaz
Thermostat de sécurité
Sonde chauffage
Sonde fumées
Raccord coaxial
MR : départ chauffage
US : entrée eau chaude
sanitaire
GAS : entrée gaz dans la
chaudière
ES : entrée eau froide
sanitaire
RR : retour installation
de chauffage
Caractéristique de la pompe de circulation basse consommation
La pompe modulante utilisée est de grande hauteur manométrique et convient sur n’importe
quel type d’installation de chauffage monotube ou bitube. Le dégazeur incorporé dans le corps
de la pompe permet une purge rapide de l’installation de chauffage.
Dimensions
Luna Platinum HTE
Ø 60/100
Modèle
Référence
Prix € HT
Luna Platinum 2.24 HTE H
CLUP224HT
2 426
Luna Platinum 2.24 HTE V
CLUP224HV
2 367
Luna Platinum 2.33 HTE H
CLUP233HT
2 802
Luna Platinum 2.33 HTE V
CLUP233HV
2 743
Chaudières murales 19
MURALES
Schéma de principe
Collectif murales 2014_Mise en page 1 19/02/14 15:39 Page20
LUNA PLATINUM
1.12 - 1.24
solution
COMPTAGE D’ÉNERGIE
DISPONIBILITÉ AVRIL 2014, NOUS CONSULTER
AVANTAGES
PRODUIT
} Chauffage seul
} Condensation
} Puissance de 2 à 24 kW
Solution
PMR
} Plage de régulation de 10 à 100%
} Pompe modulante
} Régulation complète déportable
} Affichage avec menu déroulant
} Système Gaz Adaptive Control
} Solaire compatible
} Sonde extérieure de série
Contrôle permanent de la combustion et gestion de
la vanne gaz pour un rendement optimal
Régulation déportable Luna Platinum HTE
(voir options accessoires de régulation page 32)
ble
Compati
n Td
o
avec Ball
H
300 E
Caractéristiques techniques
Données
RT 2012
●
LUNA PLATINUM HTE
Type de générateur
Type de chaudière
Energie
Evacuation
Plage de puissance
Puissance nominale chauffage 80/60 °C
Puissance utile intermédiaire
Rendement charge mini et 30°C
Rendement charge 30 % et 30°C
Rendement charge 100 % et 70°C
Plage de température chauffage
Puissance électrique des auxiliaires hors circulateur à Pmin
Puissance électrique des auxiliaires hors circulateur à Pn
Type de circulateur
Puissance circulateur maxi
Puissance circulateur mini
Puissance circulateur RT 2012
Débit minimal
Pertes à l'arrêt ∆T 30
Puissance électrique à charge nulle (veille)
Pression acoustique à 1 m Pmin
Poids
kW
kW
kW
%
%
%
°C
W
W
W
W
W
l/h
W
W
dB(A)
kg
●
●
●
●
●
●
●
●
●
Valeurs actualisées disponibles sur le site d'Uniclima: www.rt2012-chauffage.com
*Avec accessoire coude 3CEP page 38
20 Chaudières murales
1.12
1.24
Chauffage seul
Condensation
Gaz naturel ou propane
Ventouse - Cheminée C13, C33, C43, C43P*, C53, C63, C83, B23, B23p, C93
2,0-12,0
2,4-24
12
24
3,6
7,2
108,5
108
97,7
97,6
25/80
15
25
50
vitesse variable et pression différentielle variable
70
35
53
0
35
4,1
35,2
35,1
34,5
Collectif murales 2014_Mise en page 1 19/02/14 15:39 Page21
1 Pompe avec
2
17
18
16
20
21
22
15
FOURNITURES STANDARD
Chaudière murale simple service à
condensation.
• Équipée d’une chambre de
combustion et échangeur
spiralé en inox (316 L),
• Modulation intégrale de la puissance
entre 10 et 100 %,
• Tirage flux forcé et cheminée B.23,
• Fonctionnement au gaz naturel avec
possibilité de transformation au GPL.
• Filtre chauffage intégré et visitable
permettant de protéger le corps de
chauffe.
3
4
19
23
24
15
14
25
13
9
10
12
13
14
15
16
17
18
19
20
21
22
1
23
24
25
26
A
Ventilateur
Venturi air-gaz
Vase d’expansion
By-pass automatique
Siphon avec
évacuation des
condensats
Équipement disponible en
tant qu’accessoire :
B Robinet départ eau de
chauffage avec robinet
de vidange
C Raccord sortie eau
chaude sanitaire /
Ballon
D Robinet entrée GAZ
E Robinet entrée eau
froide sanitaire
F Groupe de remplissage
chaudière
(déconnecter / robinet)
G Robinet retour eau
chauffage
M 9
10
2
4
26
26 C
A B
3
D
E
Raccordements hydrauliques
F
MR : départ
chauffage
GAS : entrée gaz
dans la
chaudière
RR : retour
installation de
chauffage
FONCTIONNEMENT
EN CHAUFFAGE
Le circulateur assure la circulation vers
les radiateurs, un By-pass automatique
garantit une circulation correcte
contrôlée par un pressostat.
La température de chauffage réglable
de 20°C à 80°C est contrôlée par la
sonde chaufage qui agit sur la mise en
marche du brûleur et l’ouverture
modulante de la vanne gaz en continu.
Lorsqu’un ballon avec échangeur est
raccordé à la chaudière, la vanne de
priorité assure la circulation vers le
ballon lorsque la sonde CTN du ballon
détecte une température ECS trop
basse.
À l’arrêt du brûleur, par un thermostat
d’ambiance, le circulateur fonctionne
3 mn en post circulation.
séparateur d’air
Robinet de vidange
chaudière
Manomètre
Soupape de sécurité 3
bars
Pressostat hydraulique
Vanne trois voies
motorisée
Échangeur sanitaire
Vanne gaz
Thermostat de sécurité
Sonde chauffage
Sonde fumées
Raccord coaxial
Échangeur eau-fumées
Électrode d’allumage
Brûleur
Électrode de détection
de flamme
Collecteur mélange airgaz
Caractéristique de la pompe de circulation basse consommation
La pompe modulante utilisée est de grande hauteur manométrique et convient sur n’importe
quel type d’installation de chauffage monotube ou bitube. Le dégazeur incorporé dans le corps
de la pompe permet une purge rapide de l’installation de chauffage.
Luna Platinum HTE
Dimensions
Modèle
Référence
Ø 60/100
Prix € HT
Luna Platinum 1.12 HTE H
CLUP112HT
2 168
Luna Platinum 1.12 HTE V
CLUP112HV
2 109
Luna Platinum 1.24 HTE H
CLUP124HT
2 257
Luna Platinum 1.24 HTE V
CLUP124HV
2 198
Chaudières murales 21
MURALES
Schéma de principe
Collectif murales 2014_Mise en page 1 19/02/14 15:39 Page22
INITIA Plus Duo
3.24 - 3.33
} Chauffage et ECS
} Accumulation 45 l
} Condensation
} Puissance de 3,8 à 33 kW
solution
COMPTAGE D’ÉNERGIE
DISPONIBILITÉ AVRIL 2014, NOUS CONSULTER
AVANTAGES
PRODUIT
} Plage de régulation de 16 à 100%
} Simplicité du tableau de commandes
} Ballon 45l inox à serpentin
} Rendement 108%
Tableau Initia Plus Duo HTE rétro-éclairé
Caractéristiques techniques
Données
RT 2012
●
INITIA PLUS DUO HTE
Type de générateur
Type de chaudière
Energie
Evacuation
Plage de puissance
Puissance nominale chauffage 80/60 °C
Puissance utile intermédiaire
Rendement charge mini et 30°C
Rendement charge 30 % et 30°C
Rendement charge 100 % et 70°C
C
H Plage de température chauffage
A
U Puissance électrique des auxiliaires hors circulateur à Pmin
F Puissance électrique des auxiliaires hors circulateur à Pn
F
A Type de circulateur
G Puissance circulateur maxi
E
Puissance circulateur mini
Puissance circulateur RT 2012
Débit minimal
Pertes à l'arrêt ∆T 30
Puissance électrique à charge nulle (veille)
Puissance nominale sanitaire sur PCI
Débit spécifique à ∆T 30
Classification EN 13203
S Constante de refroidissement (justifiée)
A
N Pertes à l'arrêt du ballon ∆T 45
I Temps de réchauffage
T
A Débit soutirable en 10 mn
I Capacité de stockage
R
E Température maxi ballon
Hauteur relative serpentin
Hystérésis du ballon
N° Zone du thermostat
Pression acoustique à 1 m Pmin
Poids
kW
kW
kW
%
%
%
°C
W
W
W
W
W
l/h
W
W
kW
L/min
Wh/K.l.24h
W
mn
l
°C
dB(A)
kg
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
3.24
Accumulation
Condensation
Gaz naturel ou propane
Ventouse - Cheminée C13, C33, C43, C43P*, C53, C63, C83, B23, B23p, C93
4.0-24.0
5.5-33.0
20
28
6
8,4
108,3
108,3
108
108
97.7
97.7
25-80°C
25-80°C
15
15
45
60
à débit constant et fonctionnement intermittent
75
75
40
40
40
40
0
0
58
61
2,1
2,1
24
33
16.6
19.5
***
***
0,78
0,78
64
64
10
10
166
200
40
40
80
80
0,7
0,7
5
5
1
1
36,1
35,3
62
64
Valeurs actualisées disponibles sur le site d'Uniclima : www.rt2012-chauffage.com - *Avec accessoire coude 3CEP page 38
22 Chaudières murales
3.33
Collectif murales 2014_Mise en page 1 19/02/14 15:39 Page23
13
16
17
18
19
20
21
22
23
12
24
25
11
25
26
27
14
10
28
29
FOURNITURES STANDARD
• Chaudière murale à accumulation.
• Équipée d’une chambre de
combustion et échangeur spirale en
inox (316 L),
• Modulation intégrale de la puissance
entre 16 et 100 %,
• Tirage flux forcé (FF) et cheminée
B.23,
• Fonctionnement gaz naturel avec
possibilité de transformation au GPL.
FONCTIONNEMENT
EN ECS
• Mise en température du ballon.
La sonde CTN contrôle la
température du ballon et assure la
priorité au réchauffage de
l’échangeur immergé (serpentin) par
mise en service de la pompe
chauffage et basculement de la
vanne 3 voies,
• Le contrôle de température ECS est
assuré par 1 sonde sanitaire CTN.
30
15
31
C
1
9
A
B
8
7
5 4
D
E 3
2 F
Caractéristique de la pompe de circulation
basse consommation
La pompe utilisée à 2 vitesses automatiques est de grande hauteur
manométrique et convient sur n’importe quel type d’installation de
chauffage monotube ou bitube.
Le dégazeur incorporé dans le corps de la pompe permet une purge
rapide de l’installation de chauffage.
Initia Plus Duo HTE
1
2
3
4
5
Vanne gaz
Manomètre
By-pass automatique
Filtre retour chauffage
Pompe avec séparateur
d’air
7 Soupape de sécurité ECS
(8 bars)
8 Limiteur de débit
9 Robinet de vidange
ballon
10 Sonde ballon ECS
11 Ballon (40 litres)
12 Échangeur ECS ballon
13 Anode sacrificielle
ballon
14 Robinet de remplissage
chaudière
15 Disconnecteur
16 Vase d’expansion
17 Sonde fumées
18 Raccord coaxial
19 Échangeur eau-fumées
20 Électrode d’allumage
21 Brûleur
22 Collecteur mélange airgaz
23 Électrode de détection de
flamme
24 Thermostat de sécurité
25 Sonde chauffage
(dép./ret.)
26 Ventilateur
27 Venturi air/gaz
28 Pressostat hydraulique
29 Soupape de sécurité
chauffage (3 bars)
30 Vanne trois voies
motorisée
31 Robinet de vidange
chaudière
A Sortie eau chaude
sanitaire/Ballon
B Entrée eau froide
sanitaire
C Siphon avec évacuation
des condensats
D Retour eau de chauffage
E Départ eau de chauffage
F Entrée GAZ
Dimensions
Raccordements
hydrauliques
Ø 60/100
MR :
US :
GR :
ES :
RR :
départ chauffage
sortie eau chaude sanitaire
entrée gaz dans la chaudière
entrée eau froide sanitaire
retour installation de chauffage
Modèle
Référence
Prix € HT
INITIA PLUS DUO 3.24 HTE H
C1PL324HT
3 069
INITIA PLUS DUO 3.24 HTE V
C1PL324HV
3 010
INITIA PLUS DUO 3.33 HTE H
C1PL333HT
3 318
INITIA PLUS DUO 3.33 HTE V
C1PL333HV
3 259
Chaudières murales 23
MURALES
Schéma de principe
Collectif murales 2014_Mise en page 1 19/02/14 15:39 Page24
INITIA Plus Max
2.24 - 2.28
}
}
}
}
solution
COMPTAGE D’ÉNERGIE
Chauffage et ECS
Mini-accumulation
Condensation
Puissance de 3,8 à 28 kW
DISPONIBILITÉ AVRIL 2014, NOUS CONSULTER
AVANTAGES
PRODUIT
} Plage de régulation de 16 à 100%
} Simplicité du tableau de commandes
} Haute performance sanitaire
} Rendement 108%
Tableau Initia Plus Max HTE rétro-éclairé
Caractéristiques techniques
Données
RT 2012
●
INITIA PLUS MAX HTE
Type de générateur
Type de chaudière
Energie
Evacuation
Plage de puissance
Puissance nominale chauffage 80/60 °C
Puissance utile intermédiaire
Rendement charge mini et 30°C
Rendement charge 30 % et 30°C
Rendement charge 100 % et 70°C
C
H Plage de température chauffage
A
U Puissance électrique des auxiliaires hors circulateur à Pmin
F Puissance électrique des auxiliaires hors circulateur à Pn
F
A Type de circulateur
G Puissance circulateur maxi
E
Puissance circulateur mini
Puissance circulateur RT 2012
Débit minimal
Pertes à l'arrêt ∆T 30
Puissance électrique à charge nulle (veille)
Puissance nominale sanitaire sur PCI
Débit spécifique à ∆T 30
Classification EN 13203
Pression acoustique à 1 m Pmin
Poids
S
A
N
I
T
A
I
R
E
kW
kW
kW
%
%
%
°C
W
W
W
W
W
l/h
W
W
kW
L/min
●
●
●
●
●
●
●
●
●
●
dB(A)
kg
Valeurs actualisées disponibles sur le site d'Uniclima: www.rt2012-chauffage.com
*Avec accessoire coude 3CEP page 38
24 Chaudières murales
2.24
2.28
Mini-accumulation
Condensation
Gaz naturel ou propane
Ventouse - Cheminée C13, C33, C43, C43P*, C53, C63, C83, B23, B23p, C93
4.0-24.0
4.7-28.0
20
24
6
7,2
108,3
108
97.7
25-80°C
15
45
55
à débit constant et fonctionnement intermittent
75
40
40
0
35
2,1
24
28
12,5
14,5
***
35,8
34,2
38,5
Collectif murales 2014_Mise en page 1 19/02/14 15:39 Page25
1 Pompe avec
18
17
19
2
20
3
4
21
5
22
23
6
7
16
24
FOURNITURES STANDARD
Chaudière murale à condensation
mini accumulée.
• Équipée d’une chambre de
combustion et échangeur spirale en
inox (316 L),
• Modulation intégrale de la puissance
entre 16 et 100 %,
• Tirage flux forcé et cheminée B.23,
• Fonctionnement gaz naturel avec
possibilité de transformation au GPL.
• Filtre chauffage intégré et visitable
permettant de protéger le corps de
chauffe.
16
15
14
13
25
12
11
1
8
9
10
11
12
13
14
15
16
17
séparateur d’air
Robinet de vidange
chaudière
Manomètre
Soupape de sécurité 3
bars
Robinet de remplissage
installation
Filtre sanitaire et
limiteur de débit
Capteur de priorité
sanitaire
Sonde sanitaire
Pressostat hydraulique
Vanne trois voies
motorisée
Clapet anti-retour
Echangeur sanitaire
Vanne gaz
Vase d’expansion
Thermostat de sécurité
Sonde chauffage
Sonde fumées
18
19
20
21
22
Raccord coaxial
Echangeur eau-fumées
Electrode d’allumage
Brûleur
Electrode de détection
de flamme
23 Collecteur mélange
air-gaz
24 Ventilateur
25 Venturi
A Siphon avec évacuation
des condensats
Équipement disponible en
tant qu’accessoire :
B Robinet départ eau de
chauffage
C Sortie eau chaude
sanitaire/Ballon
D Robinet entrée GAZ
E Robinet entrée eau
froide sanitaire
F Robinet retour eau
chauffage
M
2
10
9 8
A B
7 6
C D
5
E
F
4
Raccordements hydrauliques
3
FONCTIONNEMENT
EN ECS
La chaudière dispose d’une réserve
d’énergie primaire stockée dans le vase
d’expansion, un système de priorité
contrôle régulièrement la température
de ce stockage par une vanne de
priorité. Lors d’un puisage sanitaire
supérieur à 2 l/mn, les vannes de
priorité enclenchent la circulation sur le
vase d’expansion et l’échangeur à
plaques. La montée en température de
l’eau chaude sanitaire se fait
immédiatement (< 5 secondes).
La température de l’eau chaude est
contrôlée par 2 sondes CTN (chauffage
et eau chaude) afin de garantir une
parfaite stabilité de la température
d’eau en agissant sur l’ouverture
modulante de la vanne gaz.
La stabilité de température est
maintenue constante en cas de
puisages simultanés grâce à la
capacité en eau du système.
MR : départ chauffage
US : entrée eau chaude
sanitaire
GAS : entrée gaz dans la
chaudière
ES : entrée eau froide
sanitaire
RR : retour installation
de chauffage
Caractéristique de la pompe de circulation basse consommation
La pompe utilisée à 2 vitesses automatiques est de grande hauteur manométrique et convient
sur n’importe quel type d’installation de chauffage monotube ou bitube. Le dégazeur incorporé
dans le corps de la pompe permet une purge rapide de l’installation de chauffage.
Initia Plus Max HTE
Dimensions
Ø 60/100
Modèle
Référence
Prix € HT
INITIA PLUS MAX 2.24 HTE H
C1PLM224HT
2 539
INITIA PLUS MAX 2.24 HTE V
C1PLM224HV
2 480
INITIA PLUS MAX 2.28 HTE H
C1PLM228HT
2 678
INITIA PLUS MAX 2.28 HTE V
C1PLM228HV
2 619
Chaudières murales 25
MURALES
Schéma de principe
Collectif murales 2014_Mise en page 1 19/02/14 15:39 Page26
INITIA Plus
2.24 - 2.28 - 2.33
solution
COMPTAGE D’ÉNERGIE
}
}
}
}
Chauffage et ECS
Micro-accumulation
Condensation
Puissance de 3,8 à 33 kW
DISPONIBILITÉ AVRIL 2014, NOUS CONSULTER
AVANTAGES
PRODUIT
} Plage de régulation de 16 à 100%
} Simplicité du tableau de commandes
} Circulateur modulant classe “A” 2.28 HTE
} Pompe 2 vitesses automatiques
2.24 et 2.33 HTE
} Rendement 108%
INITIA PLUS 2.28 HTE
DISPONIBILITÉ
AVRIL 2014
Avec circulateur modulant
classe “A”, à haute efficacité
énergétique
Tableau Initia Plus HTE rétro-éclairé
UTÉ
NOUVEA
2014
Caractéristiques techniques
Données
RT 2012
●
INITIA PLUS HTE
Type de générateur
Type de chaudière
Energie
Evacuation
Plage de puissance
Puissance nominale chauffage 80/60 °C
Puissance utile intermédiaire
Rendement charge mini et 30°C
Rendement charge 30 % et 30°C
C Rendement charge 100 % et 70°C
H Plage de température chauffage
A
U Puissance électrique des auxiliaires hors circulateur à Pmin
F Puissance électrique des auxiliaires hors circulateur à Pn
F
A Type de circulateur
G
E Puissance circulateur maxi
Puissance circulateur mini
Puissance circulateur RT 2012
Débit minimal
Pertes à l'arrêt ∆T 30
Puissance électrique à charge nulle (veille)
Puissance nominale sanitaire sur PCI
Débit spécifique à ∆T 30
Classification EN 13203
Pression acoustique à 1 m Pmin
Poids
S
A
N
I
T
A
I
R
E
kW
kW
kW
%
%
%
°C
W
W
W
W
W
l/h
W
W
kW
L/min
dB(A)
kg
●
●
●
●
●
●
●
●
●
●
2.28
2.24
2.33
avec circulateur Classe “A”
Micro accumulation
Condensation
Gaz naturel ou propane
Ventouse - Cheminée C13, C33, C43, C43P*, C53, C63, C83, B23, B23p, C93
4.0-24.0
4.7-28.0
5.5-33.0
20
24
28
6
7
8,4
108,3
108
97.7
25-80°C
15
15
15
45
55
60
à débit constant et
vitesse variable et pression
à débit constant et
fonctionnement intermittent
différentielle variable
fonctionnement intermittent
75
47
75
40
3
40
40
25
40
0
35
35
40
2,1
2,1
2,1
24
28
33
12,1
14,1
16
***
35,8
34,2
34,9
38,5
38,5
39,5
Valeurs actualisées disponibles sur le site d'Uniclima: www.rt2012-chauffage.com
*Avec accessoire coude 3CEP page 38
26 Chaudières murales
Collectif murales 2014_Mise en page 1 19/02/14 15:39 Page27
1 Pompe avec
17
18
16
19
20
2
3
4
5
21
22
15
23
15
FOURNITURES STANDARD
Chaudière murale micro accumulée à
condensation.
• Équipée d’une chambre de
combustion et échangeur spiralé en
inox (316 L),
• Modulation intégrale de la puissance
entre 16 et 100 %,
• Tirage flux forcé et cheminée B.23,
• Fonctionnement gaz naturel avec
possibilité de transformation au GPL.
• Filtre chauffage intégré et visitable
permettant de protéger le corps de
chauffe.
• Circulateur modulant classe “A”, à
haute efficacité énergétique pour le
modèle Initia Plus 2.28 HTE.
24
14
25
13
12
11
1
M
10
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
Echangeur eau-fumées
Electrode d’allumage
Brûleur
Electrode de détection
de flamme
22 Collecteur mélange airgaz
23 Ventilateur
24 Venturi
25 Vase d’expansion
A Siphon avec
évacuation des
condensats
Équipement disponible en
tant qu’accessoire :
B Robinet départ eau de
chauffage
C Sortie eau chaude
sanitaire/Ballon
D Robinet entrée GAZ
E Robinet entrée eau
froide sanitaire
F Robinet retour eau
chauffage
2
9 8
A B
7 6
C D
3
5
E
F
Raccordements hydrauliques
4
DESCRIPTIF DU
PRINCIPE DE LA MICRO
ACCUMULATION
Le système de gestion électronique de
Initia Plus HTE permet de maintenir en
température le système de production
d’eau chaude durant les périodes de
puisage.
Le système peut être modifié par
l’utilisateur pour passer en mode “eco”.
L’eau chaude arrive rapidement et à
température constante.
séparateur d’air
Robinet de vidange
chaudière
Manomètre
Soupape de sécurité 3
bars
Robinet de
remplissage
installation
Filtre sanitaire et
limiteur de débit
Capteur de priorité
sanitaire
Sonde sanitaire
Pressostat hydraulique
Vanne trois voies
motorisée
Clapet anti-retour
Echangeur sanitaire
Vanne gaz
Thermostat de sécurité
Sonde chauffage
Sonde fumées
Raccord coaxial
MR : départ chauffage
US : entrée eau chaude
sanitaire
GAS : entrée gaz dans la
chaudière
ES : entrée eau froide
sanitaire
RR : retour installation
de chauffage
Caractéristique de la pompe de circulation basse consommation
La pompe utilisée à 2 vitesses automatiques est de grande hauteur manométrique et convient
sur n’importe quel type d’installation de chauffage monotube ou bitube. Le dégazeur incorporé
dans le corps de la pompe permet une purge rapide de l’installation de chauffage.
Dimensions
Initia Plus HTE
Ø 60/100
Modèle
Référence
Prix € HT
INITIA PLUS 2.24 HTE H
C1PL224HT
2 279
INITIA PLUS 2.24 HTE V
C1PL224HV
2 220
INITIA PLUS 2.28 HTE H
7614719
2 590
INITIA PLUS 2.28 HTE V
7614720
2 531
INITIA PLUS 2.33 HTE H
C1PL233HT
2 632
INITIA PLUS 2.33 HTE V
C1PL233HV
2 573
Chaudières murales 27
MURALES
Schéma de principe
Collectif murales 2014_Mise en page 1 19/02/14 15:39 Page28
INITIA Plus
Compact
2.24 - 2.28 - 2.33
solution
COMPTAGE D’ÉNERGIE
}
}
}
}
Chauffage et ECS
Micro-accumulation
Condensation
Puissance de 3,8 à 33 kW
DISPONIBILITÉ AVRIL 2014, NOUS CONSULTER
AVANTAGES
PRODUIT
} Plage de régulation de 16 à 100%
} Simplicité du tableau de commandes
} Circulateur modulant classe “A” 2.28 HTE
} Dimensions compactes (700 x 400 x 300)
} Rendement 108%
INITIA PLUS COMPACT 2.28 HTE
DISPONIBILITÉ
AVRIL 2014
Avec circulateur modulant
classe “A”, à haute efficacité
énergétique
Tableau Initia Plus Compact HTE rétro-éclairé
UTÉ
NOUVEA
Caractéristiques techniques
Données
RT 2012
●
INITIA PLUS COMPACT HTE
Type de générateur
Type de chaudière
Energie
Evacuation
Plage de puissance
Puissance nominale chauffage 80/60 °C
Puissance utile intermédiaire
Rendement charge mini et 30°C
Rendement charge 30 % et 30°C
Rendement charge 100 % et 70°C
C
H Plage de température chauffage
A
U Puissance électrique des auxiliaires hors circulateur à Pmin
F Puissance électrique des auxiliaires hors circulateur à Pn
F
A Type de circulateur
G
E Puissance circulateur maxi
Puissance circulateur mini
Puissance circulateur RT 2012
Débit minimal
Pertes à l'arrêt ∆T 30
Puissance électrique à charge nulle (veille)
Puissance nominale sanitaire sur PCI
Débit spécifique à ∆T 30
Classification EN 13203
Pression acoustique à 1 m Pmin
Poids
S
A
N
I
T
A
I
R
E
2014
kW
kW
kW
%
%
%
°C
W
W
W
W
W
l/h
W
W
kW
L/min
dB(A)
kg
●
●
●
●
●
●
●
●
●
●
2.28
2.33
avec circulateur Classe “A”
Micro accumulation
Condensation
Gaz naturel ou propane
Ventouse - Cheminée C13, C33, C43, C43P*, C53, C63, C83, B23, B23p, C93
4.0-24.0
4.7-28.0
5.5-33.0
20
24
28
6
7
8,4
108,3
108
97.7
25-80°C
15
15
15
45
55
60
à débit constant et
vitesse variable et pression
à débit constant et
fonctionnement intermittent
différentielle variable
fonctionnement intermittent
75
47
75
40
3
40
40
25
40
0
31
31
37
2,1
2,1
2,1
24
28
33
12,1
14,1
16
***
36,1
34,2
35,3
34
34
36
2.24
Valeurs actualisées disponibles sur le site d'Uniclima: www.rt2012-chauffage.com
*Avec accessoire coude 3CEP page 38
28 Chaudières murales
Collectif murales 2014_Mise en page 1 19/02/14 15:39 Page29
1 Pompe avec
17
2
16
3
4
18
19
5
20
21
22
6
7
8
15
23
24
15
14
FOURNITURES STANDARD
Chaudière murale micro-accumulée à
condensation.
• Équipée d’une chambre de
combustion et échangeur spiralé en
inox (316 L),
• Modulation intégrale de la puissance
entre 16 et 100 %,
• Tirage flux forcé et cheminée B.23,
• Fonctionnement gaz naturel avec
possibilité de transformation au GPL.
• Filtre chauffage intégré et visitable
permettant de protéger le corps de
chauffe.
• Circulateur modulant classe “A”,
à hautes efficacités énergétiques
pour le modèle Initia Plus
Compact 2.28 HTE.
DESCRIPTIF DU PRINCIPE
DE LA MICRO
ACCUMULATION
Le système de gestion électronique de
Initia Plus Compact HTE permet de
maintenir en température le système de
production d’eau chaude durant les
périodes de puisage. Le système peut
être modifié par l’utilisateur pour passer
en mode “eco”. L’eau chaude arrive
rapidement et à température constante.
25
13
1
12
2
6
7
11
A B
9 8 C D
11
12
13
14
15
16
17
18
19 Électrode d’allumage
20 Brûleur
21 Électrode de détection
de flamme
22 Collecteur mélange airgaz
Ventilateur
Venturi air-gaz
Vase d’expansion
Siphon avec
évacuation des
condensats
Équipement disponible en
tant qu’accessoire :
B Robinet départ eau de
chauffage avec robinet
de vidange
C Raccord sortie eau
chaude
sanitaire/Ballon
D Robinet entrée GAZ
E Robinet entrée eau
froide sanitaire
F Groupe de remplissage
chaudière
(déconnecter / robinet)
G Robinet retour eau
chauffage
23
24
25
A
3
5
10
9
10
séparateur d’air
Vanne motorisée à
trois voies
Manomètre
Filtre circuit chauffage
extractible
Filtre eau froide
sanitaire extractible
Capteur de priorité
sanitaire
Sonde NTC sanitaire
Soupape de retenue
sur by-pass
automatique
Pressostat hydraulique
Robinet de vidange
chaudière
Soupape de sécurité
hydraulique
Échangeur sanitaire
Vanne gaz
Thermostat de sécurité
Sonde NTC chauffage
Sonde fumées
Raccord coaxial
Échangeur eau-fumées
4
E
F
Raccordements hydrauliques
MR : départ
chauffage
GAS : entrée gaz
dans la
chaudière
RR : retour
installation de
chauffage
Caractéristique de la pompe de circulation basse consommation
La pompe utilisée à 2 vitesses automatiques est de grande hauteur manométrique et convient
sur n’importe quel type d’installation de chauffage monotube ou bitube. Le dégazeur incorporé
dans le corps de la pompe permet une purge rapide de l’installation de chauffage.
Dimensions
Initia Plus Compact HTE
Ø 60/100
Modèle
Référence
Prix € HT
INITIA PLUS COMPACT 2.24 HTE H
C1PLC224HT
2 158
2 099
INITIA PLUS COMPACT 2.24 HTE V
C1PLC224HV
INITIA PLUS COMPACT 2.28 HTE H
7614721
2 390
INITIA PLUS COMPACT 2.28 HTE V
7614722
2 331
INITIA PLUS COMPACT 2.33 HTE H
C1PLC233HT
2 427
INITIA PLUS COMPACT 2.33 HTE V
C1PLC233HV
2 368
Chaudières murales 29
MURALES
Schéma de principe
Collectif murales 2014_Mise en page 1 19/02/14 15:39 Page30
INITIA Plus
1.12 - 1.24 - 1.28
} Chauffage seul
} Condensation
} Puissance de 2 à 28 kW
solution
COMPTAGE D’ÉNERGIE
DISPONIBILITÉ AVRIL 2014, NOUS CONSULTER
AVANTAGES
PRODUIT
} Plage de régulation de 16 à 100%
} Simplicité du tableau de commandes
} Pompe 2 vitesses automatiques
} Rendement 108%
Tableau Initia Plus HTE rétro-éclairé
Caractéristiques techniques
Données
RT 2012
●
INITIA PLUS HTE
Type de générateur
Type de chaudière
Energie
Evacuation
Plage de puissance
Puissance nominale chauffage 80/60 °C
Puissance utile intermédiaire
Rendement charge mini et 30°C
Rendement charge 30 % et 30°C
Rendement charge 100 % et 70°C
Plage de température chauffage
Puissance électrique des auxiliaires hors circulateur à Pmin
Puissance électrique des auxiliaires hors circulateur à Pn
Type de circulateur
Puissance circulateur maxi
Puissance circulateur mini
Puissance circulateur RT 2012
Débit minimal
Pertes à l'arrêt ∆T 30
Puissance électrique à charge nulle (veille)
Pression acoustique à 1 m Pmin
Poids
kW
kW
kW
%
%
%
°C
W
W
W
W
W
l/h
W
W
dB(A)
kg
●
●
●
●
●
●
●
●
●
Valeurs actualisées disponibles sur le site d'Uniclima: www.rt2012-chauffage.com
*Avec accessoire coude 3CEP page 38
30 Chaudières murales
1.12
1.24
1.28
Chauffage seul
Condensation
Gaz naturel ou propane
Ventouse - Cheminée C13, C33, C43, C43P*, C53, C63, C83, B23, B23p, C93
2.0-12.0
4.0-24.0
4.7-28.0
12
24
28
3,6
7,2
8,4
108,3
108,3
108,3
108
108
108
97.8
97.6
97.6
25-80°
25-80°C
25-80°C
15
15
15
30
45
60
à débit constant et fonctionnement intermittent
75
75
75
40
40
40
40
40
40
0
0
0
35
35
40
2,1
2,1
2,1
36,1
35,8
35,2
34,5
34,5
34,5
Collectif murales 2014_Mise en page 1 19/02/14 15:39 Page31
1 Pompe avec
2
17
18
16
19
20
21
22
15
FOURNITURES STANDARD
Chaudière murale simple service à
condensation.
• Équipée d’une chambre de
combustion et échangeur spiralé en
inox (316 L),
• Modulation intégrale de la puissance
entre 16 et 100 %,
• Tirage flux forcé et cheminée B.23,
• Fonctionnement gaz naturel avec
possibilité de transformation au GPL.
• Filtre chauffage intégré et visitable
permettant de protéger le corps de
chauffe.
23
24
15
14
25
13
3
4
9
10
12
13
14
15
16
17
18
19
20
21
22
1
séparateur d’air
Robinet de vidange
chaudière
Manomètre
Soupape de sécurité
3 bars
Pressostat hydraulique
Vanne trois voies
motorisée
Échangeur sanitaire
Vanne gaz
Thermostat de sécurité
Sonde chauffage
Sonde fumées
Raccord coaxial
Échangeur eau-fumées
Électrode d’allumage
Brûleur
Électrode de détection
de flamme
Collecteur mélange
air-gaz
23
24
25
26
A
Ventilateur
Venturi air-gaz
Vase d’expansion
By-pass automatique
Siphon avec
évacuation des
condensats
Équipement disponible en
tant qu’accessoire :
B Robinet départ eau de
chauffage avec robinet
de vidange
C Raccord sortie eau
chaude sanitaire /
Ballon
D Robinet entrée GAZ
E Robinet entrée eau
froide sanitaire
F Groupe de remplissage
chaudière
(déconnecter / robinet)
G Robinet retour eau
chauffage
M 9
10
2
4
26
26 C
A B
3
D
E
Raccordements hydrauliques
F
MR : départ
chauffage
GAS : entrée gaz
dans la
chaudière
RR : retour
installation
de chauffage
FONCTIONNEMENT
EN CHAUFFAGE
Le circulateur assure la circulation vers
les radiateurs, un By-pass automatique
garantit une circulation correcte
contrôlée par un pressostat.
La température de chauffage réglable
de 20°C à 80°C est contrôlée par une
sonde CTN qui agit sur la mise en
marche du brûleur et l’ouverture
modulante de la vanne gaz en continu.
Lorsqu’un ballon avec échangeur est
raccordé à la chaudière, la vanne de
priorité assure la circulation vers le
ballon lorsque la sonde CTN du ballon
détecte une température ECS trop
basse.
À l’arrêt du brûleur, par un thermostat
d’ambiance, le circulateur fonctionne
3 mn en post circulation.
Caractéristique de la pompe de circulation basse consommation
La pompe utilisée à 2 vitesses automatiques est de grande hauteur manométrique et convient
sur n’importe quel type d’installation de chauffage monotube ou bitube. Le dégazeur incorporé
dans le corps de la pompe permet une purge rapide de l’installation de chauffage.
Dimensions
Initia Plus HTE
Ø 60/100
Modèle
Référence
Prix € HT
INITIA PLUS 1.12 HTE H
C1PL112HT
2 037
INITIA PLUS 1.12 HTE V
C1PL112HV
1 978
INITIA PLUS 1.24 HTE H
C1PL124HT
2 120
INITIA PLUS 1.24 HTE V
C1PL124HV
2 061
INITIA PLUS 1.28 HTE H
C1PL128HT
2 418
INITIA PLUS 1.28 HTE V
C1PL128HV
2 359
Chaudières murales 31
MURALES
Schéma de principe
Collectif murales 2014_Mise en page 1 19/02/14 15:39 Page32
Accessoires de régulation
INITIA PLUS
/ LUNA PLATINUM
INTERFACE DE COMMANDE FILAIRE Luna Platinum HTE
Interface 3 LED chaudière pour raccordement filaire de la régulation Luna Platinum HTE en sonde d’ambiance.
Désignation
Récepteur 3 LED et support mural Luna Platinum HTE
Référence
C7108482
Prix € HT
50
INTERFACE DE COMMANDE SANS FIL Luna Platinum HTE
Interface 5 LED chaudière pour raccordement sans fil de la régulation Luna Platinum HTE en sonde d’ambiance.
Désignation
Récepteur 5 LED et support mural Luna Platinum HTE
32 Chaudières murales
Référence
C7108484
Prix € HT
140
Collectif murales 2014_Mise en page 1 19/02/14 15:39 Page33
SONDE D’AMBIANCE Luna Platinum et Initia Plus HTE
Référence
C7108526
C7108527
C7108528
C7108529
C7108484
C7102343
Prix € HT
90
110
120
140
140
110
MURALES
Désignation
Sonde d'ambiance
Sonde d'ambiance sans fil
Sonde d'ambiance programmable
Sonde d'ambiance programmable sans fil
Récepteur 5 LED intégrable pour accessoire sans fil
Récepteur 5 LED pose murale pour accessoire sans fil
Sonde d’ambiance
Sonde d’ambiance
programmable
THERMOSTATS D’AMBIANCE Luna Platinum HTE
et Initia Plus HTE
Thermostat
Thermostat d’ambiance digital sans fil
Thermostat d’ambiance filaire
Référence
CFF000025
CFF000028
Prix € HT
231
104
Thermostat digital avec programme hebdomadaire liaison radio
• Boitier pour fixation murale en saillie ou
• Sauvegarde permanente des paramètres
boite d'encastrement. Positionnement sur
de réglage
pied possible (socle fourni)
• Protection classe III IP30
• Affichage sur grand écran LCD rétro
• Réglages par molette 7 positions et
éclairé
touches élastomères
• Fonctionnement sur piles 2x1,5V (fournies)
Thermostat d’ambiance
SONDE EXTÉRIEURE Luna Platinum HTE et Initia Plus HTE
Désignation
Référence
Prix € HT
Sonde extérieure
C7104873
37
Sonde extérieure sans fil
C7103027
175
SONDE SANITAIRE POUR BALLON EXTÉRIEUR Luna Platinum HTE
et Initia Plus HTE 1.12/1.24/1.28
Désignation
Sonde sanitaire
Référence
C14076810
Prix € HT
23
Chaudières murales 33
Collectif murales 2014_Mise en page 1 19/02/14 15:39 Page34
ACCESSOIRES D’INSTALLATION
Désignation
Référence
Prix € HT
C7108754
C7108871
C7108755
C7108753
C14058810
C7107769
C14088010
C7108756
C7108872
C7108832
C7107925
C71407971
82
82
82
82
90
72
95
30
30
42
185
97
C7107881
C7107880
C7107883
C7107845
C71414101
C7110044
C7107844
82
96
96
96
12
62
72
Luna Platinum HTE et Initia Plus HTE
Kit de remplacement Chaffoteaux Celtic
Kit de remplacement Chaffoteaux Nectra
Kit de remplacement ELM
Kit de remplacement SD
Kit de remplacement universel
Cadre écarteur avec douilles chaudières mixtes
Cadre écarteur avec douilles chaudières Duo
Connexion hydraulique pour ballon PIM sol
Connexion hydraulique pour ballon PIM mural
Kit de remplissage installation
Kit solaire thermostatique pour chaudières mixtes (standard et compact)
Vase sanitaire 2l pour chaudière Initia Plus Duo HTE
Initia Plus Compact HTE
Kit de remplacement Initia Plus Compact / Chaffoteaux Nectra
Kit de remplacement Initia Plus Compact / Chaffoteaux Celtic
Kit de remplacement Initia Plus Compact / ELM
Kit de remplacement Initia Plus Compact / SD
Clé coudée spéciale remplacement
Câche robinetterie Initia Plus Compact
Cadre écarteur Initia Plus Compact avec douilles
Kit de remplacement ELM
Kit de remplacement Chaffoteaux Celtic
Kit de remplacement SD
GUIDE SOLUTIONS DE
REMPLACEMENT
DISPONIBLE.
NOUS CONSULTER
Cache robinetterie Initia Plus Compact HTE
34 Chaudières murales
Collectif murales 2014_Mise en page 1 19/02/14 15:39 Page35
MODULE PARTAGE
Désignation
Référence
Prix € HT
C7104770
C7104769
C71098820
1 210
1 710
215
C7104770
C7108485
C7104769
C7108485
C71098820
1 210
91
1 710
91
215
Luna Platinum HTE
Module partage 1 zone HT + 1 zone BT Nu
Module partage 1 zone HT + 2 zones BT Nu
Habillage pour module partage
Module partage 1 zone HT + 1 zone BT Nu
+ Régulation Platinum (obligatoire)
Module partage 1 zone HT + 2 zones BT Nu
+ Régulation Platinum (obligatoire)
Habillage pour module partage
Luna Platinum HTE avec module partage 2 zones
Luna Platinum HTE avec module partage 3 zones
Initia Plus HTE avec module partage 2 zones
Chaudières murales 35
MURALES
Initia Plus HTE
Collectif murales 2014_Mise en page 1 19/02/14 15:40 Page36
Accessoires de régulation
INITIA PLUS
/ LUNA PLATINUM
Guide de choix accessoires de régulation Initia Plus HTE
Configuration de l'installation
Circuit 1
Sondes d'ambiance
Circuit
Hydraulique
Filaire
Sans fil
Accessoires de régulation à commander en option
Circuit 2
Sondes d'ambiance
Sondes d'ambiance
Filaire
Sondes sans fil
Sans fil
Sonde
d'ambiance
C7108527
X
-
-
Sonde
d'ambiance
programmable
C7108529
Sonde
d'ambiance
programmable
C7108528
1 sonde d'ambiance sans fil
au choix
-
X
-
-
X
-
X
-
X
-
-
X
1 sonde d'ambiance sans fil
au choix
-
X
-
X
2 sondes d'ambiance sans fil
au choix
36 Chaudières murales
Sonde
d'ambiance
C7108526
Récepteur 5 LED
pose murale pour
sonde sans fil
C7102343
Filaire
OU
C7104873
1 sonde sans fil +
1 récepteur 5 LED
(C7102343) pose
murale
1 récepteur 5 LED
pose murale
C7103027
1 sonde
filaire
1 sonde sans fil
1 sonde sans fil +
1 récepteur 5 LED
(C7102343) pose
murale
2 sondes d'ambiance
filaire au choix
1 sonde d'ambiance filaire
au choix
Sondes extérieures
Sans fil
1 sonde d'ambiance filaire
au choix
-
1 circuit
direct
1 circuit
direct
+ 1 circuit
Vanne
3 Voies
Récepteur 5 led
Sondes filaires
1 récepteur 5 LED
pose murale
1 sonde sans fil
1 récepteur 5 LED
pose murale
1 sonde sans fil
1 sonde
filaire
Collectif murales 2014_Mise en page 1 19/02/14 15:40 Page37
Guide de choix accessoires de régulation Luna Platinum HTE
Circuit 1
Accessoires de régulation à commander en option
Circuit 2
Sans fil
Filaire
Sans fil
Boitier
de
régulation
Filaire
Circuits
de chauffage
Sondes
Sondes
d'ambiance d'ambiance
X
-
-
-
-
X
-
-
Sondes d'ambiance
Sondes sans fil
Récepteur 3 et 5 LED
Sondes extérieures
Sondes filaires
Sonde
Sonde
Sonde
d'ambiance
Sonde
d'ambiance
d'ambiance programmable d'ambiance programmable
C7108527 C7108529
C7108526 C7108528
Sans fil
Récepteur
3 LED
intégrable
+ support
C7108482
Récepteur
5 LED
intégrable
+ support
C7108484
Récepteur
5 LED pose
murale pour
sonde sans fil
C7102343
1 sonde d'ambiance filaire
au choix
1 circuit
direct
1 récepteur
5 LED pose
murale
C7102343
1 sonde d'ambiance sans fil
au choix
-
1 circuit direct
+ 1 circuit Vanne 3 Voies
Sur
chaudière
En
ambiance
X
-
1 récepteur
5 LED intégrable
C7108484
-
-
X
-
X
-
-
X
1 sonde d'ambiance sans fil 1 sonde d'ambiance filaire
au choix
au choix
-
X
-
X
2 sondes d'ambiance sans
fil au choix
X
-
X
-
1 sonde d'ambiance filaire
au choix
-
X
X
-
1 sonde d'ambiance filaire
au choix
-
X
-
X
1 sonde d'ambiance
sans fil au choix
1 sonde
sans fil
1 sonde
sans fil
2 sondes d'ambiance
filaire au choix
X
Incluse dans
fourniture
C7103027 standard
1 sonde
sans fil +
1 module RF
5 LED
Incluse dans
(C7102343) fourniture
pose murale
standard
1 récepteur
3 LED
intégrable
C7108482
X
OU
1 sonde
sans fil +
1 récepteur
5 LED
Incluse dans
(C7102343) fourniture
pose murale
standard
Sur
chaudière
En
ambiance
Filaire
1 récepteur
5 LED pose
murale
C7102343
1 récepteur
5 LED pose
murale
C7102343
1 récepteur
3 LED
intégrable
C7108482
1 récepteur
5 LED intégrable
C7108484
1 récepteur
5 LED intégrable
C7108484
1 sonde
sans fil +
1 récepteur
5 LED
(C7102343)
pose murale Incluse dans
fourniture
1 sonde
standard
sans fil
1 sonde
sans fil
1 sonde
sans fil +
1 récepteur
5 LED
(C7102343)
pose murale Incluse dans
fourniture
1 sonde
standard
sans fil
1 sonde
sans fil
Chaudières murales 37
MURALES
Configuration de l'installation
Collectif murales 2014_Mise en page 1 19/02/14 15:40 Page38
Accessoires pour
INITIA PLUS
/ LUNA PLATINUM
ACCESSOIRES DE RACCORDEMENT Ø 60 X 100
Accessoires chaudières murales
Référence
Prix € HT
Condensation - Accessoires ventouse concentrique
Diamètre 60 x 100
Terminal horizontal 750 mm Ø 60 x 100
C14059610
69
Coude 90° Ø 60 x 100
C14059710
41
Coude 45° Ø 60 x 100
C14059810
38
Coude 15° Ø 60 x 100
CRN146002
74
Coude 30° Ø 60 x 100
CRN146001
74
Rallonge 1000 mm Ø 60 x 100
C14059510
49
Terminal vertical Ø 60/100 noir
C71413581
149
Solin pour toit incliné Ø 100
C14036610
67
Solin pour toit plat Ø 100
C14036710
52
7616509
120
Terminal horizontal 750 mm rénovation 60x95 et coude de départ
Diamètre 80 x 125
Adaptateur Ø 60 x 100 - 80 x 125
Diamètre 100
Rosace intérieure Ø 100
CFF000019
62
C14017710
11
Rosace intérieure Ø 100 étanche compatible RT 2012 / BBC
CFFUA0002
19
Coude clapet Ø 80/125 3 CEP
CFFUB0001
129
Coude clapet Ø 80/125 3CEP
RACCORDEMENT VENTOUSE
AB
CD
E
FG
H
I
Lmax = 10 m - Ø 60/100 mm
Lmax = 25 m - Ø 80/125 mm
Lmax = 9 m - Ø 60/100 mm
Lmax = 24 m - Ø 80/125 mm
Lmax = 10 m - Ø 60/100 mm
Lmax = 25 m - Ø 80/125 mm
Lmax = 10 m - Ø 60/100 mm
Lmax = 25 m - Ø 80/125 mm
Lmax = 8 m - Ø 60/100 mm
Lmax = 23 m - Ø 80/125 mm
Lmax = 9 m - Ø 60/100 mm
Lmax = 24 m - Ø 80/125 mm
38 Chaudières murales
Collectif murales 2014_Mise en page 1 19/02/14 15:40 Page39
ACCESSOIRES DE RACCORDEMENT VENTOUSE Ø 80/125
Référence
Prix €
HT
80/125
80/125
80/125
80/125
80/125
80/125
80/125
80/125
80/125
80/125
80/125
80/125
80/125
80/125
80/125
125
CRN994781
CRN994774
CRN995535
CRN994927
CRN994934
CRN994910
CRN994996
CRN994989
CRN994972
CRN994965
CRN994958
CRN994941
CRN907224
CRN578646
CRN603331
CRN578622
184
184
154
83
70
60
142
117
99
98
59
75
78
78
35
6
11
125
125
80
80
80
80
80
80
80
80
80
80
80
80
14
15
15
80
80
80
80
80
80
CRN941525
CRN556320
CRN998055
CFF000020
CRN994903
CRN994897
CRN994873
CRN994866
CRN994859
CRN994842
CRN994835
CRN994828
CRN994811
CRN956529
CRN578462
CRN998116
CRN998109
CRN998093
CRN998086
CRN998079
CRN998062
70
36
341
329
25
25
15
15
39
25
15
64
37
26
16
329
290
185
26
1 015
448
5
3
3
3
3
8
4
4
4
1
6
6
7
17
16
10
13
9
12
12
12
MURALES
ACCESSOIRES VENTOUSE TYPE C13-C33 Ø 80 X 125
Terminal ventouse vertical couleur brique 80/125 PPs/AL (1)
Terminal ventouse vertical couleur noire 80/125 PPs/AL (1)
Rallonge 2000 mm, Ø 80/125 PPs/AL
Rallonge 1000 mm, Ø 80/125 PPs/AL
Rallonge 250 mm, Ø 80/125 PPs/AL
Rallonge 500 mm, Ø 80/125 PPs/AL
Té à 90° avec accès maintenance Ø 80/125 PPs/AL
Élément droit avec accès maintenance Ø 80/125 PPs/AL
Coude 15°, Ø 80/125 PPs/AL
Coude 30°, Ø 80/125 PPs/AL
Coude 45°, Ø 80/125 PPs/AL
Coude 90°, Ø 80/125 PPs/AL
Solin pour toit en pente 25° - 45° couleur brique
Solin pour toit en pente 25° - 45° couleur noire
Solin pour toit plat
Collier Ø 125
ACCESSOIRES CHEMINÉE ÉTANCHE TYPE B33-C93 Ø 80,7
Prise d'air pour installation cheminée B33
Plaque de finition, Ø 125 pour installation ventouse C33
Kit de raccordement cheminée tube Ø 80 flexible*
Kit de raccordement cheminée tube Ø 80 rigide*
Coude 15°, Ø 80 PPs
Coude 30°, Ø 80 PPs
Coude 45°, Ø 80 PPs
Coude 87°, Ø 80 PPs
Rallonge 2000 mm, Ø 80 PPs
Rallonge 1000 mm, Ø 80 PPs
Rallonge 500 mm, Ø 80 PPs
Elément T pour accès maintenance, Ø 80 PPs
Ouverture pour accès maintenance, Ø 80 PPs
Ecarteur Ø 80 pour tuyau rigide
Grille d'aération
Aide pour insertion du tuyau flexible Ø 80
Ouverture pour accès maintenance, du tuyau flexible Ø 80
Coupleur pour tuyau flexible Ø 80
Ecarteur pour tuyau flexible Ø 80
Tuyau de fumées flexible Ø 80 PPs rouleau 25 m
Tuyau de fumées flexible Ø 80 PPs rouleau 12,5 m
Diamètre
• La longueur verticale droite maxi est : 18 m, la
longueur horizontale droite maxi est : 6 m.
• Pour toutes les parties horizontales, donner une
pente de 5 % vers la chaudière.
• La longueur équivalente droite est égale à la
somme des longueurs droites + les longueurs
équivalentes des coudes :
1 coude à 90 ° = 1 m
1 coude à 30 ° = 0,35 m
1 coude à 45 ° = 0,5 m
1 coude à 15 ° = 0,2 m
• Les rallonges droites ( 3 ) de 0.25, 0.5,
1 ou 2 m peuvent être coupées à la longueur
souhaitée. La coupe doit être faite sans
déformation et ébavurée.
• La longueur maxi L1 du conduit vertical est :
20 m, la longueur maxi L2 + L3 du
raccordement horizontal est : 2 m.
• La solution retenue sera soit un conduit rigide sur
toute la hauteur, soit un conduit souple sur toute la
hauteur (solution mixte interdite).
(1) obligatoire pour ventouse verticale
* Comprenant : 1 chapeau de gaine, 1 coude avec rail, 4 écarteurs. Type CRN : conduit sous avis technique ISOCOX.
• Prévoir 1 écarteur sous chaque emboîtement
femelle (tuyau rigide) ou tous les 2 m
maximum.
EXEMPLES D’INSTALLATIONS Ø 80/125
Exemple d’installation ventouse type C33
avec des conduits verticaux Ø 80/125
5
Exemple sur cheminée existante :
conduit rigide
Pour installation
cheminée B33
6
Exemple sur cheminée existante :
conduit flexible
Pour installation
ventouse C93
Pour installation
cheminée B33
16
16
1
3
9
4
2
17
3
3
4
13
10
11
1
14
12
3
8
15
9
3
10
8
3
10
13
Chaudières murales 39
Collectif murales 2014_Mise en page 1 19/02/14 15:40 Page40
Accessoires pour
INITIA PLUS
/ LUNA PLATINUM
RACCORDEMENT VENTOUSE
INSTALLATION DES CONDUITS
L’installation de la chaudière est réalisable sans difficulté grâce aux accessoires fournis qui sont décrits plus loin. La chaudière est prévue, à l’origine, pour être raccordée à
un conduit d’évacuation-aspiration de type coaxial, vertical ou horizontal. Il est également possible d’utiliser des conduits séparés grâce au séparateur de flux.
RECOMMANDATIONS
C13, C33 Les parties terminales du conduit d’évacuation dédoublé doivent être prévues à l’intérieur d’un carré de
50 cm de côté. Des instructions détaillées sont contenues dans tous les accessoires.
C53 Les parties terminales des conduits d’aspiration de l’air comburant et d’évacuation des produits de la
combustion ne doivent pas être prévues sur des murs opposés de l’édifice.
C63 La perte de charge maximale des conduits ne doit pas dépasser 100 Pa. Les conduits doivent être certifiés
pour ce type d’utilisation et pour une température supérieure à 100 °C. La partie terminale du conduit de la fumée
doit être certifiée conforme à la Norme EN 14471.
C43, C83 La cheminée ou le conduit de fumée doivent être adaptés à cet usage.
La pente minimum, vers la chaudière, du conduit d’évacuation doit être de 5 cm par mètre de
longueur.
Pour une meilleure installation, utiliser des accessoires fournis par le fabricant de l’appareil.
Pour garantir une sûreté de fonctionnement il faut que les conduits d’évacuation de fumée soient
bien fixés au mur au moyen des brides de fixation.
CONDUIT COAXIAL
Ce type de conduit permet d’évacuer les gaz brûlés et
d’aspirer l’air comburant aussi bien à l’extérieur de l’édifice
que dans des conduits de fumée de type LAS. Le coude
coaxial à 90° permet de raccorder la chaudière aux
conduits d’évacuationaspiration en toutes directions grâce
à la possibilité de rotation à 360°. Il peut également être
utilisé comme coude supplémentaire en association avec
le conduit coaxial ou le coude à 45°.
En cas d’évacuation à l’extérieur, le conduit d’évacuationaspiration doit déborder du mur d’au moins 18 mm pour
permettre de positionner la rosace en aluminium et son
scellement et éviter ainsi toute infiltration d’eau.
• L’insertion d’un coude à 90° réduit la longueur totale du conduit de 1 mètre.
• L’insertion d’un coude à 45° réduit la longueur totale du conduit de 0,5 mètre.
• Le premier coude à 90° ne rentre pas dans le calcul de la longueur maximum disponible.
40 Chaudières murales
Initia Plus 2.24 HTE
Collectif murales 2014_Mise en page 1 19/02/14 15:40 Page41
OBLIGATIONS
RECOMMANDATIONS
A = 0,40 m : distance minimum de l’axe de l’orifice d’évacuation
des gaz brûlés à toute ouverture.
D = 0,30 m : entraxe de l’orifice d’évacuation des gaz brûlés au
sol et/ou au débord du toit ou au-dessus d’un
balcon.
B = 0,60 m : distance minimum de l’axe de l’orifice d’évacuation
des gaz brûlés à tout autre orifice de ventilation.
C = 1,80 m : les orifices d’évacuation débouchant directement
sur une voie de circulation extérieure, voie publique
ou privée à moins de 1,80 mètre au-dessus du sol,
hormis pour les appareils à condensation, doivent
comporter un déflecteur inamovible donnant aux
gaz évacués une direction sensiblement parallèle
au mur.
Les orifices d’évacuation et de prise d’air des appareils à circuit
étanche débouchant à moins de 1,80 mètre au dessus du sol
doivent être protégés efficacement contre toute intervention
extérieure susceptible de nuire à leur fonctionnement normal.
E = 1,50 m : entraxe de l’orifice d’évacuation des gaz brûlés à un
mur à 90°, avec fenêtre ou orifice de ventilation.
F = 0,80 m : entraxe de l’orifice d’évacuation des gaz brûlés à un
mur à 90°, sans ouverture.
G = 2,00 m : distance de l’orifice d’évacuation des gaz brûlés à
une haie ou plantation.
H = 0,10 m : entraxe de l’orifice d’évacuation des gaz brûlés à
une gouttière ou une tuyauterie verticale.
Distance entre 2 ventouses 0,60 m.
Les distances indiquées ont pour départ l’axe de l’orifice d’évacuation des gaz brûlés.
Chaudières murales 41
MURALES
RÈGLES D’IMPLANTATION
Collectif murales 2014_Mise en page 1 19/02/14 15:40 Page42
Composition
LUNA PLATINUM
CODE
DÉSIGNATION
COMPOSANT
CORPS
CHAUDIÈRE
BARRETTE
ROBINETTERIE
CLUP112HT
Luna Platinum 1.12 HTE H
C71088090
C7108578
CLUP112HV
Luna Platinum 1.12 HTE V
C71088090
C7108578
CLUP124HT
Luna Platinum 1.24 HTE H
C71088110
C7108578
CLUP124HV
Luna Platinum 1.24 HTE V
C71088110
C7108578
CLUP224HT
Luna Platinum 2.24 HTE H
C71087940
C7107716
CLUP224HV
Luna Platinum 2.24 HTE V
C71087940
C7107716
CLUP233HT
Luna Platinum 2.33 HTE H
C71087960
C7107716
CLUP233HV
Luna Platinum 2.33 HTE V
C71087960
C7107716
CLUPM228HT
Luna Platinum Max 2.28 HTE H
C71088030
C7107716
CLUPM228HV Luna Platinum Max 2.28 HTE V
C71088030
C7107716
CLUPM233HT
Luna Platinum Max 2.33 HTE H
C71088060
C7107716
CLUPM233HV Luna Platinum Max 2.33 HTE V
C71088060
C7107716
CLUP324HT
Luna Platinum Duo 3.24 HTE H
C71087980
C14073711
CLUP324HV
Luna Platinum Duo 3.24 HTE V
C71087980
C14073711
CLUP333HT
Luna Platinum Duo 3.33 HTE H
C71088000
C14073711
CLUP333HV
Luna Platinum Duo 3.33 HTE V
C71088000
C14073711
42 Chaudières murales
COUDE
TERMINAL
CONCENTRIQUE
CONCENTRIQUE
90°
C14059710
C14059610
ROSACE
ADAPTATEUR
DOUILLES
SORTIE
SONDE
INSTALLATION
VERTICALE
EXTÉRIEURE
NEUVE
80/125
C14017710
C7104873
CFF000019
C14059710
C14059610
C7104873
C14017710
C7104873
CFF000019
C14059710
C14059610
C14017710
CFF000019
C14059710
C14059610
C14017710
CFF000019
C14059710
C14059610
C14017710
CFF000019
C14059710
C14059610
C14017710
CFF000019
C14059710
C14059610
C14017710
C14059610
C7108531
C7104873
C7108531
C7104873
C7108531
C7104873
C7108531
C7104873
C7108531
C7104873
C7108531
C7104873
C7108531
C7104873
C7108531
C7104873
C7104873
CFF000019
C14059710
C7104873
C14017710
C7104873
C7104873
CFF000019
C7104873
Collectif murales 2014_Mise en page 1 19/02/14 15:40 Page43
Composition
INITIA PLUS
DÉSIGNATION
COMPOSANT
CORPS
CHAUDIÈRE
BARRETTE
ROBINETTERIE
COUDE
CONCENTRIQUE
90°
TERMINAL
CONCENTRIQUE
ROSACE
C14059710
C14059610
C14017710
C1PL112HT
Initia Plus 1.12 HTE H
C71083570
C7108578
C1PL112HV
Initia Plus 1.12 HTE V
C71083570
C7108578
C1PL124HT
Initia Plus 1.24 HTE H
C71083580
C7108578
C1PL124HV
Initia Plus 1.24 HTE V
C71083580
C7108578
C1PL128HT
Initia Plus 1.28 HTE H
C71083590
C7108578
C1PL128HV
Initia Plus 1.28 HTE V
C71083590
C7108578
C1PL224HT
Initia Plus 2.24 HTE H
C71080490
C7107716
C1PL224HV
Initia Plus 2.24 HTE V
C71080490
C7107716
7614719
Initia Plus 2.28 HTE H
7116524
C7107716
7614720
Initia Plus 2.28 HTE V
7116524
C7107716
C1PL233HT
Initia Plus 2.33 HTE H
C71083600
C7107716
C1PL233HV
Initia Plus 2.33 HTE V
C71083600
C7107716
C1PLM224HT
Initia Plus Max 2.24 HTE H
C71083990
C7107716
C1PLM224HV
Initia Plus Max 2.24 HTE V
C71083990
C7107716
C1PLM228HT
Initia Plus Max 2.28 HTE H
C71080500
C7107716
C1PLM228HV
Initia Plus Max 2.28 HTE V
C71080500
C7107716
C1PL324HT
Initia Plus Duo 3.24 HTE H
C71086250
C14073711
C1PL324HV
Initia Plus Duo 3.24 HTE V
C71086250
C14073711
C1PL333HT
Initia Plus Duo 3.33 HTE H
C71086320
C14073711
C1PL333HV
Initia Plus Duo 3.33 HTE V
C71086320
C14073711
C1PLC224HT
Initia Plus Compact 2.24 HTE H
C71080540
C7103752
C1PLC224HV
Initia Plus Compact 2.24 HTE V
C71080540
C7103752
7614721
Initia Plus Compact 2.28 HTE H
7116525
C7103752
7614722
Initia Plus Compact 2.28 HTE V
7116525
C7103752
C1PLC233HT
Initia Plus Compact 2.33 HTE H
C71080550
C7103752
C1PLC233HV
Initia Plus Compact 2.33 HTE V
C71080550
C7103752
ADAPTATEUR
SORTIE
VERTICALE
80/125
DOUILLES
INSTALLATION
NEUVE
CFF000019
C14059710
C14059610
C14017710
CFF000019
C14059710
C14059610
C14017710
CFF000019
C14059710
C14059610
C14017710
C7108531
CFF000019
C14059710
C14059610
C14017710
C7108531
CFF000019
C14059710
C14059610
C14017710
C14059610
C14017710
C14059610
C14017710
C14059610
C7108531
C7108531
CFF000019
C14059710
C7108531
C7108531
CFF000019
C14059710
C7108531
C7108531
CFF000019
C14059710
C7108531
C7108531
C14017710
CFF000019
C14059710
C14059610
C14017710
CFF000019
C14059710
C14059610
C14017710
C7107843
CFF000019
C14059710
C14059610
C14017710
C7107843
CFF000019
C14059710
C14059610
C7107843
C14017710
C7107843
C7107843
CFF000019
C7107843
Chaudières murales 43
MURALES
CODE
Collectif murales 2014_Mise en page 1 19/02/14 15:40 Page44
GUIDE DE CHOIX
LUNA ST
Mini-accumulation(1) Micro-accumulation
Instantanée
Basse température
Condensation
ÉLIGIBLE
Au crédit
d’impôt*
Luna ST Flirt
2.24 CF-VMC-FF
Luna ST Compact
2.24 CF-VMC-FF
Luna ST Max
2.24 CF-VMC-FF
(1) Stockage tampon intégré ≤ 10 l
Luna ST Duo(2)
Accumulée
3.24 CF-VMC-FF
Luna ST Prime
1.24 CF-FF
* Crédit d’impôts sous réserve de la Loi de Finances en vigueur.
44 Chaudières murales
Luna ST HTE
2.28
MURALES
Collectif murales 2014_Mise en page 1 19/02/14 15:40 Page45
Luna ST Flirt :
Confort sanitaire :
Chaudière gaz, chauffage et eau chaude sanitaire instantanée.
Eau chaude immédiate à température constante
Une prestation eau chaude haut de gamme à coût attractif
selon norme EN13203
Luna ST HTE :
Chaudière gaz, chauffage et ECS à micro-accumulation avec
Luna ST Compact : gestion électronique de la température du corps de chauffe et de la
consommation ECS.
Luna ST Max
Confort sanitaire :
Luna ST Duo :
Chaudière gaz, chauffage et eau chaude à mini accumulation.
Débit d’eau chaude exceptionnel (jusqu’ à 16.3 l / mn)
immédiatement disponible, le système breveté “Dynamic Max”
permet en effet d’atteindre en moins de 5 secondes le niveau de
température souhaité et un niveau de confort inégalé
selon norme EN13203
Chaudière gaz, chauffage et eau chaude sanitaire à
accumulation.
Performances élevées pour plus d’économies (rendement optimal)
L’eau chaude en abondance pour un espace occupé minimum
Stabilité de température pour répondre aux exigences de confort
Chaudières murales 45
Collectif murales 2014_Mise en page 1 19/02/14 15:40 Page46
LUNA ST
} Chauffage et ECS
} Condensation gaz
} Micro accumulée
2.28
} Simplicité du tableau
} Débit spécifique élevé
AVANTAGES
PRODUIT
} Solution de remplacement Chappée
} Faibles émissions polluantes
1
2
5
3
6
12
7
8
4
9
10
1
2
3
4
5
6
7
8
9
10
11
12
Collecteur de fumées
Vase d’expansion
Électrode d’allumage
Vanne gaz modulante
Sécurité de température fumée
Corps de chauffe en acier inox
Électrode de contrôle de flamme
Ventilateur à vitesse variable
Échangeur eau-eau à plaques
Circulateur
Tableau de commandes
Isolation phonique
11
C
H
A
U
F
F
A
G
E
LUNA ST HTE
Type de générateur
Type de chaudière
Évacuation
Puissance nominale
Débit calorifique
Débit des fumées
Rendement charge 100 % et 70 °C
Rendement charge 30 % et 30 °C
Pertes à l’arrêt ∆T = 30 K
Température mini de retour chaudière
Puissance électrique auxiliaire
Puissance électrique circulateur
Débit nominal d’eau à Pn ∆T = 15 K
Pression max utilisation primaire
2.28 HTE
Micro accumulé
kW
kW
kg/h
%
%
W
°C
W
W
m3/h
bar
G 20 m3/h
Débit de gaz maximum
S
A
N
I
T
A
I
R
E
Puissance utile nominale
Débit spécifique à ∆T = 30 K
Débit à ∆T = 25 K
Régulation électronique modulante
Plage de température
Pression maximale
Pression minimale
Seuil d’enclenchement
46 Chaudières murales
3
G 25 m /h
G 31 kg/h
kW
l/mn
l/mn
°C
bar
bar
l/mn
Condensation
Ventouse - Cheminée
24
24,7
43,2
96,8
107,5
54,4
15
65
90
1,37
3
3,06
3,55
2,25
28
12,9
16,1
OUI
De 35 à 60
8
0,2
2,5
Schéma de principe
26
25
24
27
FONCTIONNEMENT
EN CHAUFFAGE
(TOUS MODÈLES)
Lors d’un puisage sanitaire supérieur à
2,5 l/mn, la vanne de priorité
enclenche la circulation vers
l’échangeur à plaques, la mise en
marche du brûleur.
La température de l’eau chaude est
contrôlée (35 à 65°C) par 2 sondes
CTN (chauffage et eau chaude) afin de
garantir une parfaite stabilité de la
température d’eau en agissant sur
l’ouverture modulante continue de la
vanne gaz.
DESCRIPTIF DU
PRINCIPE DE LA MICRO
ACCUMULATION
équipé de filtre
23
5 Robinet retour chauffage
6 Sonde CTN sanitaire /
22
21
20
7 Capteur de priorité ECS
8 Soupape de non-retour
9 Capteur de flux avec
Sonde CTN ballon
limiteur de débit d’eau
10 Soupape de sécurité
11 Manomètre
12 Robinet de vidange
16
13 Pompe avec
15
14 Soupage automatique
32
14
15 Échangeur eau-eau à
33
13
12
11
10
30
31
35 9
8
34
6
1
2
7
3
4
chaudière
séparateur d’air
de purge d’air
plaques
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
Vanne gaz
Ventilateur
Diaphragme gaz
Mélangeur avec venturi
Échangeur eau-fumée
Collecteur mélange air/gaz
Électrode de détection
de flamme
Brûleur
Électrode d’allumage
Thermostat fumées
Raccord coaxial
Vase d’expansion
Sonde CTN chauffage
Thermostat de sécurité
105°
Siphon
Pressostat hydraulique
Moteur vanne 3 voies
Vanne 3 voies
By-pass automatique
Disconnecteur
Raccordements hydrauliques
5
MR : départ chauffage
US : entrée eau chaude
sanitaire
GAS : entrée gaz dans la
chaudière
ES : entrée eau froide
sanitaire
RR : retour installation
de chauffage
Caractéristique de la pompe de circulation basse consommation
La pompe utilisée est de grande hauteur manométrique et convient sur n’importe quel type
d’installation de chauffage monotube ou bitube. Le dégazeur incorporé dans le corps de la
pompe permet une purge rapide de l’installation de chauffage.
6
5
Hauteur manomètrique mH2O
Chaudière murale à condensation
micro accumulée.
• Équipée d’une chambre de
combustion et échangeur spirale
en inox (316 L),
• Modulation intégrale de la puissance
entre 30 et 100 %,
• Tirage flux forcé et cheminée B.23,
• Fonctionnement gaz naturel avec
possibilité de transformation au GPL.
• Filtre chauffage intégré et visitable
permet de protéger le corps de
chauffe.
chaudière
4 Robinet arrivée eau
19
18
17
28
29
FOURNITURES STANDARD
1 Robinet départ chauffage
2 Robinet gaz
3 Robinet de remplissage
Dimensions
4
3
Ø 60x100
2
1
273
0
0
200
400
600
800
1000
1200 1400
177
Débit l/h
Luna ST 2.28
140
Le système de gestion électronique de
Luna ST permet de maintenir en
température le système de production
d’eau chaude durant les périodes de
puisage. Le système peut être modifié
par l’utilisateur pour passer en mode
“eco”. L’eau chaude arrive rapidement
et à température constante.
Luna ST produit de 12,9 à 15,3 litres
d’eau chaude à 35°C (eau froide à
10°C).
763
info
initia
2.33
450
Référence
Prix € HT
Luna ST 2.28 HTE H
Modèle
CLCS28HTH
2 549
Luna ST 2.28 HTE V
CLCS28HTV
2 486
FF HTE
345
Chaudières murales 47
MURALES
Collectif murales 2014_Mise en page 1 19/02/14 15:40 Page47
Collectif murales 2014_Mise en page 1 19/02/14 15:40 Page48
LUNA ST Duo
} Chauffage et ECS
} Basse température
} Accumulation 60 l
3.24 CF - VMC / 3.28 FF
AVANTAGES
PRODUIT
} Simplicité du tableau
} Haut rendement
} Débit spécifique élevé
} ECS avec ballon accumulation
1
6
1
2
3
4
5
6
7
8
9
2
7
3
8
4
Ballon inox 60 litres
Vase d’expansion chauffage
Vase d’expansion sanitaire en option
Pompe de chauffage
Manomètre
Extracteur
Échangeur en cuivre
Brûleur multirampes
Vanne gaz
9
5
Caractéristiques techniques
LUNA ST Duo
Type de générateur
3.24 CF
Type de chaudière
C
H
A
U
F
F
A
G
E
Évacuation
Puissance nominale
Débit calorifique
Débit des fumées
Volume des fumées
Tirage nécessaire
Rendement charge 100 % et 70 °C
Rendement charge 30 % et 40 °C
Pertes à l’arrêt ∆T = 30 K
Température mini de retour chaudière
Puissance électrique auxiliaire
Puissance élec. circulateur mini
Puissance élec. circulateur maxi
Pression max utilisation primaire
Débit de gaz
S
A
N
I
T
A
I
R
E
Débit nominal d’eau à Pn ∆T = 15 K
Puissance utile nominale
Débit spécifique à ∆T = 30 K
Vase d’expansion
Régulation électronique modulante
Plage de température
Pression maximale
Pression minimale
48 Chaudières murales
kW
kW
kg/h
m3/h
mbar
%
%
W
°C
W
W
W
bar
G 20 m3/h
G 25 m3/h
G 31 kg/h
m3/h
kW
l/mn
l
°C
bar
bar
Cheminée
23,3
25,8
79,2
54,1
0,05 à 0,1
91
89.8
199
25
47,4
57,7
2,73
3,17
2,00
1,34
23,3
17,7
OUI
De 35 à 60
7
0,5
3.24 CF - VMC
Accumulé*
Basse température
VMC
23,3
25,8
64,4
54,1
0,05 à 0,1
90,6
89,8
199
30
25
47,4
57,7
3
2,73
3,17
1,34
23,3
17,7
1 en option
OUI
De 35 à 60
7
0,5
3.28 FF
Ventouse
28
30,1
72
56
93,1
90,6
99
70
73,4
89,7
3,18
3,7
2,34
1,61
28
19
OUI
De 35 à 60
7
0,5
Schéma de principe
4
13
14
12
11
15
9
8
7
6
5
2
FOURNITURES STANDARD
Chaudière murale à accumulation.
Chaudière murale mixte équipée d’un
système de stockage ECS en inox
associé de 60 l.
• Modulation intégrale de la puissance
entre 40 et 100 %,
• Ajustement de la puissance en
chauffage possible entre 40 et 100 %,
• Tirage VMC ou flux forcé (FF) ou
naturel (CF),
• Fonctionnement gaz naturel avec
possibilité de transformation au GPL
(versions CF et FF).
• Filtre chauffage intégré et visitable
permet de protéger le corps de
chauffe.
19
20
21
22
23
24
1
33
32 31 30 29 28
34
35
37 38 39
36
FONCTIONNEMENT EN ECS,
MODÈLE LUNA ST Duo
25
19
20
21
22
23
24
25
26
27
28
29
30
31
32
26
27
Ø 60x100
222
466
33
950
34
35
36
600
37
201
Luna ST Duo 3.24 CF-VMC
Raccordements
hydrauliques
17
18
Dimensions
Ø 125
• Mise en température du ballon.
La sonde CTN contrôle la température
du ballon et assure la priorité au
réchauffage de l’échangeur immergé
(serpentin) par mise en service de la
pompe chauffage et basculement de
la vanne 3 voies,
• Le contrôle de température ECS est
assuré par 1 sonde sanitaire CTN.
6
7
8
9
10
11
12
13
14
15
16
16
17
18
10
3
1
2
3
4
5
38
39
Luna ST Duo 3.28 FF
Caractéristique de la pompe de circulation
basse consommation
Ballon
Sonde CTN sanitaire
Échangeur sanitaire
Vase d’expansion
Robinet de vidange
chaudière
Sonde CTN chauffage
Thermostat de sécurité
Électrode d’allumage
Échangeur eau-fumées
Boîte à fumées
Prise de pression négative
Prise de pression positive
Raccord concentrique
Pressostat air
Ventilateur
Electrode de détection de
flamme
Rampe gaz avec injecteurs
Soupape de sécurité
chauffage 3 bar
Pressostat différentiel
hydraulique
Dégazeur
Pompe avec séparateur d’air
Vanne gaz
Filtre eau chauffage
By-pass automatique
Robinet gaz
Vanne départ chauffage
Vanne retour chauffage
Manomètre
Brûleur
Vanne 3 voies
Moteur vanne 3 voies
Robinet de remplissage
chaudière
Soupape de sécurité
ballon 7 bar
Robinet de vidange ballon
Limiteur de débit d’eau
Robinet arrivée eau
équipé de filtre
Robinet de remplissage
chaudière
Disconnecteur
Soupape de non-retour
II
I
La pompe utilisée est de grande hauteur manométrique et
convient sur n’importe quel type d’installation de chauffage
monotube ou bitube. Le dégazeur incorporé dans le corps de la
pompe permet une purge rapide de l’installation de chauffage.
1 : sortie eau chaude sanitaire G1/2
2 : entrée eau froide sanitaire G1/2
3 : retour installation de chauffage
G3/4
4 : départ chauffage G3/4
5 : entrée gaz dans la chaudière
G3/4
Modèle
Luna ST Duo 3.24 CF
Luna ST Duo 3.28 FFH
Luna ST Duo 3.28 FFV 100
Luna ST Duo 3.28 FFV 125
Luna ST Duo 3.24 VMC
Référence
CLUS324CF0
CLUS324FFH
CLUS324FF0
CLUS324FF5
CLUS324VMC
Prix € HT
2 275
2 785
2 877
2 710
2 305
Chaudières murales 49
MURALES
Collectif murales 2014_Mise en page 1 19/02/14 15:40 Page49
Collectif murales 2014_Mise en page 1 19/02/14 15:40 Page50
LUNA ST Max
} Chauffage et ECS
} Basse température
} Mini-accumulée
2.24 CF - VMC - FF
} Simplicité du tableau
} Solution de remplacement
AVANTAGES
PRODUIT
1
1
2
3
4
5
6
7
8
9
10
11
12
7
2
3
8
4
9
10
11
5
6
} Débit spécifique élevé
} Réserve d’énergie primaire
Extracteur
Échangeur en cuivre
Vanne de priorité
Vanne gaz
Robinet gaz
Robinet eau froide
Vase d’expansion “Dynamic Max”
Échangeur à plaques
Soupape de sécurité
By-pass automatique
Robinet de vidange
Robinet chauffage
12
Caractéristiques techniques
LUNA ST Max
Type de générateur
2.24 CF
Type de chaudière
C
H
A
U
F
F
A
G
E
Évacuation
Puissance nominale
Débit calorifique
Débit des fumées
Volume des fumées
Tirage nécessaire
Rendement charge 100 % et 70 °C
Rendement charge 30 % et 40 °C
Pertes à l’arrêt ∆T = 30 K
Température mini de retour chaudière
Puissance électrique auxiliaire
Puissance élec. circulateur mini
Puissance élec. circulateur maxi
Pression max utilisation primaire
Débit de gaz
S
A
N
I
T
A
I
R
E
Débit nominal d’eau à Pn ∆T = 15 K
Puissance utile nominale
Débit spécifique à ∆T = 30 K
Débit spécifique à ∆T = 25 K
Régulation électronique modulante
Plage de température
Pression maximale
Pression minimale
Seuil d’enclenchement
* Chauffage et ECS, stockage tampon
50 Chaudières murales
kW
kW
kg/h
m3/h
mbar
%
%
W
°C
W
W
W
bar
G 20 m3/h
G 25 m3/h
G 31 kg/h
m3/h
kW
l/mn
l/mn
°C
bar
bar
l/mn
Cheminée
24
26,3
68,4
65
0,05 à 0,1
91,2
90,29
183
20
47,4
57,4
2,78
3,23
2,04
1,38
24
12,05
13,7
OUI
De 35 à 65
8
0,15
2
2.24 FF
Mini accumulé*
Basse température
Ventouse
25
26,9
61,2
50,3
92,9
90,7
59
30
75
47,4
57,7
3
2,84
3,31
2,09
1,43
24
12,4
14,3
OUI
De 35 à 65
8
0,15
2
2.24 VMC
VMC
24
26,3
68,4
65
0,05 à 0,1
91,2
90,29
183
20
47,4
57,7
2,78
3,23
1,38
24
12,05
13,7
OUI
De 35 à 65
8
0,15
2
Collectif murales 2014_Mise en page 1 19/02/14 15:40 Page51
1 Sonde de priorité
2
3
4
5
6
7
8
31
19
18
20
17
16
15
14
13
FOURNITURES STANDARD
Chaudière murale mixte à mini
accumulation haut rendement.
• Modulation intégrale de la puissance
entre 40 et 100 %,
• Ajustement de la puissance en
chauffage possible entre 40 et
100 %,
• Tirage naturel (CF) ou flux forcé (FF)
ou VMC,
• Fonctionnement gaz naturel avec
possibilité de transformation au GPL
(versions CF et FF).
• Filtre chauffage intégré et visitable
permet de protéger le corps de
chauffe.
21
22
23
11
24
19 Pressostat air
20 Prise de pression
négative
21 Electrode de détection
de flamme
22 Brûleur
23 Rampe gaz avec
injecteurs
24 Échangeur eau-eau
avec plaques
25 Event automatique
26 Pompe avec
séparateur d’air
27 Robinet de
remplissage circuit
28 Robinet de vidange
chaudière
29 Manomètre
30 Soupape de sécurité
hydraulique
31 Sortie concentrique
(pour le mod. Max 2.31 FF la
prise positive doit être fermée)
10
25
9
5
7
6
3
26
27
4
Raccordements hydrauliques
MR : départ chauffage
US : entrée eau
chaude sanitaire
GAS : entrée gaz dans
la chaudière
ES : entrée eau froide
sanitaire
RR : retour installation
de chauffage
28
29
30
2
1 8
FONCTIONNEMENT
EN ECS, MODÈLE
LUNA ST Max
La chaudière dispose d’une réserve
d’énergie primaire stockée dans le vase
d’expansion, un système de priorité
contrôle régulièrement la température
de ce stockage par une vanne de
priorité. Lors d’un puisage sanitaire
supérieur à 2 l/mn, les vannes de
priorité enclenchent la circulation sur le
vase d’expansion et l’échangeur à
plaques. La montée en température de
l’eau chaude sanitaire se fait
immédiatement (< 5 secondes).
La température de l’eau chaude est
contrôlée par 2 sondes CTN (chauffage
et eau chaude) afin de garantir une
parfaite stabilité de la température
d’eau en agissant sur l’ouverture
modulante de la vanne gaz.
La stabilité de température est
maintenue constante en cas de
puisages simultanés grâce à la
capacité en eau du système.
12
9
10
11
12
13
14
15
16
17
18
sanitaire
Disconnecteur
By-pass automatique
Soupape de non-retour
Pressostat hydraulique
Soupape 3 voies
Sonde CTN sanitaire
Détecteur de débit avec
filtre et limiteur de débit
d’eau
Moteur vanne 3 voies
Soupape du gaz
Vase d’expansion
Électrode d’allumage
Sonde CTN chauffage
Thermostat de sécurité
Échangeur eau-fumées
Boîte à fumées
Ventilateur
Prise de pression positive
Dimensions
Ø 60x100
225
225
345
225
345
345
763
763
Luna ST Max 2.24 CF
Luna ST Max 2.24 VMC
Caractéristique de la pompe de
circulation basse consommation
Luna ST Max 2.24 FF
II
I
La pompe utilisée est de grande hauteur manométrique et
convient sur n’importe quel type d’installation de chauffage
monotube ou bitube.
Le dégazeur incorporé dans le corps de la pompe permet
une purge rapide de l’installation de chauffage.
Modèle
Luna ST Max 2.24 CF
Luna ST Max 2.24 FFH
Luna ST Max 2.24 FFV 100
Luna ST Max 2.24 FFV 125
Luna ST Max 2.24 VMC
Référence
CLUS24CFO
CLUS24FFH
CLUS24FFO
CLUS24FF5
CLUS24VMC
Prix € HT
1 484
1 841
1 933
1 766
1 505
Chaudières murales 51
MURALES
Schéma de principe
Collectif murales 2014_Mise en page 1 19/02/14 15:40 Page52
LUNA ST COMPACT
} Chauffage et ECS
} Basse température
} Micro-accumulée
2.24 CF - VMC - FF
AVANTAGES
PRODUIT
} Dimensions extrêmement compactes
(400 x 299 x 730)
} Solution idéale pour le remplacement
} Micro-accumulation
} Simplicité du tableau
400 mm
Caractéristiques techniques
LUNA ST Compact
Type de générateur
2.24 CF
Type de chaudière
C
H
A
U
F
F
A
G
E
Évacuation
Puissance nominale
Débit calorifique
Débit des fumées
Volume des fumées
Tirage nécessaire
Rendement charge 100 % et 70 °C
Rendement charge 30 % et 40 °C
Pertes à l’arrêt ∆T = 30 K
Température mini de retour chaudière
Puissance électrique auxiliaire
Puissance électrique circulateur
Pression max utilisation primaire
Débit de gaz
S
A
N
I
T
A
I
R
E
Débit nominal d’eau à Pn ∆T = 15 K
Puissance utile nominale
Débit spécifique à ∆T = 30 K
Régulation électronique modulante
Plage de température
Pression maximale
Pression minimale
Seuil d’enclenchement
52 Chaudières murales
kW
kW
kg/h
m3/h
mbar
%
%
W
°C
W
W
bar
G 20 m3/h
G 25 m3/h
G 31 kg/h
m3/h
kW
l/mn
°C
bar
bar
l/mn
Cheminée
24
26,3
68,4
69,0
0,05 à 0,1
91,2
90,2
183
30
5
75
3
2,78
3,23
2,04
1,38
24
12
Oui
de 35 à 65
8
0,15
2
2.24 FF
Micro-accumulation
Basse Température
Ventouse
24
25,8
61,2
52,0
92,9
90,4
59
30
55
75
3
2,73
3,17
2
1,43
24
12
Oui
de 35 à 65
8
0,15
2
2.24 VMC
VMC
24
26,3
68,4
69,0
0,05 à 0,1
91,2
90,2
183
30
5
75
3
2,78
3,23
1,38
24
12
Oui
de 35 à 65
8
0,15
2
Collectif murales 2014_Mise en page 1 19/02/14 15:40 Page53
25
26
27
1 Pompe et séparateur
28
2
3
4
24
5
6
7
8
23
22
FOURNITURES STANDARD
• Chaudière murale mixte à
micro-accumulation haut
rendement.
• Modulation intégrale de la puissance
entre 40 et 100%,
• Tirage naturel (CF) ou flux forcé (FF)
ou VMC,
• Fonctionnant au gaz naturel avec
possibilité de transformation au GPL
(versions CF et FF),
• Filtre chauffage intégré et visitable
permet de protéger le corps de
chauffe.
FONCTIONNEMENT
EN ECS, MODÈLE
LUNA ST COMPACT
Le système de gestion électronique de
Luna ST Compact permet de maintenir
en température le système de
production d’eau chaude durant les
périodes de puisage. Le système peut
être modifié par l’utilisateur pour
passer en mode “eco”. L’eau chaude
arrive rapidement et à température
constante.
Modèle
9
29
21
20
19
18
17
10
11
30
13
1
2
3
4
16
10
15
13
14
9
A
12
14
15
16
17 Vanne gaz avec
diaphragme
18 Rampe gaz avec
injecteurs
19 Sonde CNT du
chauffage central
20 Électrode pour
21
22
23
24
25
26
27
28
29
30
A
B
C
D
E
l’allumage et la
détection de flamme
Thermostat de sécurité
Échangeur eau-fumées
Convoyeur fumées
Ventilateur
Tube Venturi
Prise de pression
positive
Prise de pression
négative
Pressostat d’air
Brûleur
Vase d’expansion
Départ chauffage
Sortie eau chaude
sanitaire
Gaz
Entrée eau chaude
sanitaire
Départ chauffage
5
11
B C
7
D
8
6
E
Caractéristique de la pompe de circulation basse consommation
La pompe utilisée est de grande hauteur manométrique et convient sur n’importe quel type
d’installation de chauffage monotube ou bitube. Le dégazeur incorporé dans le corps de la
pompe permet une purge rapide de l’installation de chauffage.
Dimensions
Référence
CLUSC24CFO
CLUSC24FFH
CLUSC24FFO
CLUSC24FF5
CLUSC24VMC
Prix € HT
Options
Référence
Prix €HT
Sonde extérieure
C14062111
38
Kit propane CF - FF
C71413921
Luna ST Compact 2.24 CF
Luna ST Compact 2.24 FFH
Luna ST Compact 2.24 FFV 100
Luna ST Compact 2.24 FFV 125
Luna ST Compact 2.24 VMC
12
d’air
Clapet antiretour
Vanne trois voies
Moteur vanne trois
voies
Manomètre
Filtre extractible circuit
de chauffage
Disconnecteur
Robinet de
remplissage de la
chaudière
Filtre extractible eau
froide
Détecteur de débit
sanitaire
Sonde CNT de l’eau
chaude sanitaire
Clapet anti-retour sur
by-pass automatique
Pressostat manque
d’eau
Robinet de vidange
chaudière
Soupape de sécurité
Échangeur de chaleur
eau-eau à plaque
1 367
1 703
1 795
1 628
1 367
Luna ST Compact 2.24 FF
10
Accessoires d’installation
voir page accessoires
Accessoires ventouse concentrique
voir page accessoires
Luna ST Compact 2.24 CF-VMC
Chaudières murales 53
MURALES
Schéma de principe
Collectif murales 2014_Mise en page 1 19/02/14 15:41 Page54
LUNA ST Flirt
} Chauffage et ECS
} Basse température
} Instantanée
2.24 CF - VMC - FF
AVANTAGES
PRODUIT
} Simplicité du tableau
} Solution de remplacement
1
7
2
3
8
9
4
10
11
5
6
} Facilité d’installation
} Rendement élevé
1
2
3
4
5
6
7
8
9
10
11
12
Extracteur
Échangeur en cuivre
Brûleur en Inox
Vanne gaz
Robinet gaz
Robinet eau froide
Vase d’expansion
Échangeur à plaques
Soupape de sécurité
By-pass automatique
Robinet de vidange
Soupape chauffage
12
Caractéristiques techniques
LUNA ST Flirt
Type de générateur
2.24 CF
Type de chaudière
C
H
A
U
F
F
A
G
E
Évacuation
Puissance nominale
Débit calorifique
Débit des fumées
Volume des fumées
Tirage nécessaire
Rendement charge 100 % et 70 °C
Rendement charge 30 % et 40 °C
Pertes à l’arrêt ∆T = 30 K
Température mini de retour chaudière
Puissance électrique auxiliaire
Puissance élec. circulateur mini
Puissance élec. circulateur maxi
Pression max utilisation primaire
Débit de gaz
S
A
N
I
T
A
I
R
E
Débit nominal d’eau à Pn ∆T = 15 K
Puissance utile nominale
Débit spécifique à ∆T = 30 K
Débit à ∆T = 25 K
Régulation électronique modulante
Plage de température
Pression maximale
Pression minimale
Seuil d’enclenchement
54 Chaudières murales
kW
kW
kg/h
m3/h
mbar
%
%
W
°C
W
W
W
bar
G 20 m3/h
G 25 m3/h
G 31 kg/h
m3/h
kW
l/mn
l/mn
°C
bar
bar
l/mn
Cheminée
24
26,3
68,4
69
0,05 à 0,1
91,2
90,29
183
30
20
47,4
57,7
3
2,78
3,23
2,04
1,38
24
11,2
13,7
OUI
De 35 à 65
8
0,15
2
2.24 FF
Instantané
Basse température
Ventouse
25
26,9
61,2
92,9
90,7
59
30
75
47,4
57,7
3
2,84
3,31
2,09
1,43
24
11,5
14,3
OUI
De 35 à 65
8
0,15
2
2.24 VMC
VMC
24
26,3
68,4
69
0,05 à 0,1
91,2
90,29
183
30
20
47,4
57,7
3
2,78
3,23
1,38
24
11,2
13,7
OUI
De 35 à 65
8
0,15
2
Collectif murales 2014_Mise en page 1 19/02/14 15:41 Page55
1 Sonde de priorité
2
3
4
5
6
31
17
16
18
15
14
12
10
11
FOURNITURES STANDARD
Chaudière murale instantanée
à haut rendement.
• Modulation intégrale de la puissance
entre 40 et 100 %,
• Tirage VMC ou flux forcé (FF)
ou naturel (CF),
• Fonctionnement gaz naturel avec
possibilité de transformation au GPL
(versions CF et FF).
• Filtre chauffage intégré et visitable
permet de protéger le corps de chauffe.
13
19
20
21
9
8
23
7
8
9
10
11
12
13
14
15
16
17
18
de flamme
20 Brûleur
21 Rampe gaz avec
injecteurs
22 Echangeur eau-eau à
plaques
23 Soupape automatique
de purge air
24 Pompe avec
séparateur d’air
25 Robinets de
remplissage du circuit
26 Robinets de vidange
chaudière
27 Manomètre
28 Soupape de sécurité
hydraulique
29 Disconnecteur
30 Clapet anti-retour
31 Sortie concentrique
22
7
3
29
5
4
6
24
25
26
27
28
1
2
FONCTIONNEMENT
EN ECS MODÈLE
LUNA ST Flirt
2.24 CF-VMC-FF
Raccordements hydrauliques
30
MR : départ chauffage
US : entrée eau chaude
sanitaire
GAS : entrée gaz dans la
chaudière
ES : entrée eau froide
sanitaire
RR : retour installation
de chauffage
Lors d’un puisage sanitaire supérieur à
2 l/mn, la vanne de priorité enclenche
la circulation vers l’échangeur plaques,
la mise en marche du brûleur.
La température de l’eau chaude est
contrôlée (35 à 65°C) par 2 sondes
CTN (chauffage et eau chaude) afin de
garantir une parfaite stabilité de la
température d’eau en agissant sur
l’ouverture modulante continue de la
vanne gaz.
Dimensions
Caractéristique de la
pompe de circulation
basse consommation
La pompe à 2 vitesses utilisée
est de grande hauteur
manométrique et convient sur
n’importe quel type d’installation
de chauffage monotube ou
bitube. Le dégazeur incorporé
dans le corps de la pompe
permet une purge rapide de
l’installation de chauffage.
19 Électrode de détection
sanitaire
By-pass automatique
Pressostat hydraulique
Vanne 3 voies
Sonde CTN sanitaire
Détecteur de débit avec
filtre et limiteur de débit
d’eau
Moteur vanne 3 voies
Vanne gaz
Vase d’expansion
Électrode d’allumage
Sonde CTN chauffage
Thermostat de sécurité
Echangeur eau fumées
Evacuation des fumées
Ventilateur
Prise de pression
positive
Pressostat air
Prise de pression
négative
Ø 60x100
225
225
345
225
345
345
763
763
Luna ST Flirt 2.24 CF
Luna ST Flirt 2.24 VMC
Luna ST Flirt 2.24 FF
II
I
Modèle
Luna ST Flirt 2.24 CF
Luna ST Flirt 2.24 FFH
Luna ST Flirt 2.24 FFV 100
Luna ST Flirt 2.24 FFV 125
Luna ST Flirt 2.24 VMC
Référence
CLUS224CF0
CLUS224FFH
CLUS224FF0
CLUS224FF5
CLUS224VMC
Prix € HT
1 377
1 723
1 815
1 648
1 408
Chaudières murales 55
MURALES
Schéma de principe
Collectif murales 2014_Mise en page 1 19/02/14 15:41 Page56
LUNA ST Prime
} Chauffage seul
} Basse température
1.24 CF - FF
AVANTAGES
PRODUIT
} Simplicité d’utilisation
} Performances et économies
1
7
2
3
8
9
4
10
11
5
6
} Qualité prouvée
} En phase avec l’environnement
1
2
3
4
5
6
7
8
9
10
11
12
Extracteur
Échangeur en cuivre
Brûleur en Inox
Vanne gaz
Robinet gaz
Robinet eau froide
Vase d’expansion
Échangeur à plaques
Soupape de sécurité
By-pass automatique
Robinet de vidange
Soupape chauffage
12
Caractéristiques techniques
LUNA ST Prime
Type de générateur
Type de chaudière
Évacuation
Puissance nominale
Débit calorifique
Débit des fumées
Tirage nécessaire
Rendement charge 100 % et 70 °C
Rendement charge 30 % et 50 °C
Pertes à l’arrêt ΔT = 30 K
Température mini de retour chaudière
Puissance électrique auxiliaire
Puissance électrique circulateur
Pression max utilisation (primaire)
Débit de gaz
Débit nominal d’eau à PN ΔT = 15 K
56 Chaudières murales
1.24 CF
1.24 FF
Chauffage seul
Basse température
kW
kW
kg/h
mbar
%
%
W
°C
W
W
bar
G 20 m3/h
G 25 m3/h
G 31 kg/h
Cheminée
24
26,3
68,4
0,05 à 0,1
91,2
90,29
183
30
20
47,4 - 57,7
3
2,78
3,23
2,04
1,38
Ventouse
25
26,9
68,1
92,9
90,7
59
30
75
47,4 - 57,7
3
2,84
3,31
2,09
1,43
Collectif murales 2014_Mise en page 1 19/02/14 15:41 Page57
1
1
2
3
4
5
FOURNITURES STANDARD
• Tableau de commandes très facile
d’accès,
• Modulation électronique,
• Allumage électronique,
• Détection de flamme par ionisation,
• Contrôle de température par
thermistance CTN,
• Brûleur en inox multi rampes,
• Pompe de circulation avec dégazeur,
• Coupe tirage anti-refouleur,
• Vanne gaz modulante
• Vase d’expansion 8 litres,
• By-pass automatique,
• Dispositif de post circulation,
• Dispositif antigel,
• Dispositif de contrôle de débit et
manque d’eau,
• Dispositif d’aide au diagnostic,
• Chaudière livrée pour fonctionnement
au gaz naturel (kit propane fourni
gratuitement sur demande).
2
5
MURALES
3
4
Écran indicateur de fonctionnement
Réglage de température chauffage
Réglage de température sanitaire (si ballon réchauffeur raccordé)
Sélecteur du mode de fonctionnement été / hiver
Manomètre de pression d’eau
Puissance utile
de chauffage
Modèles
1.24 CF
1.24 FFH
50°/30°
kW
80°/60°
kW
24
25
9,3
9,3
Options
Sonde sanitaire pour ballon extérieur
Accessoires d’installation
Dimension
d’évacuation
ø D mm
Poids
kg
125
100
32,5
37
Référence
C14061910
Prix € HT
23
voir page 59
• RT 2005 :
** CE Basse température pour les
modèles CF.
Dimensions
Modèle
Luna ST Prime 1.24 CF
Luna ST Prime 1.24 FFH
Luna ST Prime 1.24 FFV 100
Luna ST Prime 1.24 FFV 125
Référence
CLUS124CF0
CLUS124FFH
CLUS124FF0
CLUS124FF5
Prix € HT
1 275
1 621
1 713
1 546
Luna ST 1.24 CF-FF
Thermostats d’ambiance
Modèles
Thermostat d’ambiance digital sans fil
Thermostat d’ambiance filaire
Référence
CFF000025
CFF000028
Prix € HT
231
104
Thermostat digital avec programme hebdomadaire liaison radio
• Boitier pour fixation murale en saillie ou boîte d'encastrement. Positionnement sur pied possible
(socle fourni)
• Affichage sur grand écran LCD rétro éclairé
• Fonctionnement sur piles 2x1,5V (fournies)
• Sauvegarde permanente des paramètres de réglage
• Protection classe III IP30
• Réglages par molette 7 positions et touches élastomères
Chaudières murales 57
Collectif murales 2014_Mise en page 1 19/02/14 15:41 Page58
LUNA ST / LUNA ST
Accessoires fournis dans le kit barrette de robinetterie
- Gabarit
- Robinet gaz
- Robinet arrivée eau avec filtre
(modèle mixte)
- Joints d’étanchéité
- Chevilles 8 mm et vis
- Robinet départ chauffage
- Robinet retour chauffage avec filtre
visitable intégré
- Kit de vidage eau mixte
Module partage pour chaudière haut rendement et condensation
Kit basse température permettant le raccordement
de 2 circuits fonctionnant à des températures
différentes livrés avec régulation.
Kit partage
Référence
Prix € HT
C71407961
1 178
Dimensions
L
H
P
mm
450
600
160
Boîtier de commandes
Bouton du boîtier
de commandes
Pompe circuit haute
température
Thermostat limiteur
Thermomètre
Moteur de vanne
3 voies
Sonde température départ
Vanne 3 voies
Raccord
58 Chaudières murales
Pompe circuit
basse température
Module partage Luna ST
• Collecteur modulaire
• 1 Zone Haute Température < 85 °C
• 1 Zone Basse Température < 45 °C
• 1 pompe de circulation pour la zone Haute
Température
• 1 pompe de circulation pour la zone Basse
Température
• 1 vanne de mélange pour la zone Basse
Température
• 1 sonde CTN circuit BT
• Thermostat de sécurité circuit BT 50 °C
• Dimension (mm) : 600x450x160
• Alimentation électrique : 230V
• Raccordement chaudière et circuit Haute
Température : 3/4”
• Raccordement circuit Basse Température : 1”
Collectif murales 2014_Mise en page 1 19/02/14 15:41 Page59
A
B
C
D
Accessoires d’installation Luna ST
Accessoires murales en option
Dosseret écartement Prime - Flirt - Max - ST 60 mm
E
GUIDE
REMPLA SOLUTIONS DE
CEMENT
NOUS CO DISPONIBLE.
NSULTER
Référence
A
C71411131
F
G
Prix € HT
53
Douilles installation neuve pour dosseret écartement Prime - Flirt - Max - ST
C71413741
73
Dosseret écartement Duo + douilles
C14088010
95
Kit de remplissage installation B
C14069110
41
Kit robinet eau chaude
C14021911
34
C
Kit de remplacement C&M Celtic à visser
D
C71413551
72
Kit de remplacement C&M Nectra à visser
C71413731
70
Kit de remplacement SD à visser
C71413511
72
C71411141
73
E
Kit de remplacement ELM à visser
F
Kit de remplacement universel
C14058810
90
Kit de remplacement C&M à souder
C14050211
37
Kit de remplacement SD à souder
C14050611
37
Kit de remplacement ELM à souder
C14050711
37
Kit de vidage eau mixte
G
C14087210
29
C71412831
33
C71412341
129
Régulation AVS77 Luna ST HTE
C71411021
120
Kit interface
C71407251
22
C14061910
23
Kit de vidage eau Duo
Kit solaire thermostatique pour chaudières mixtes
• Vanne directionnelle thermostatique
• Douilles de raccordement
• Vanne isolation entrée eau froide
+
Sonde sanitaire Luna ST Prime 1.24 CF/FF
* A poser au mur pour toutes les chaudières Luna ST.
Accessoires d’installation Luna ST Compact
Accessoires murales en option
Kit de remplacement C&M Nectra
Kit de remplacement C&M Celtic
Kit de remplacement ELM
Kit de remplacement SD
Kit de remplacement universel
Cadre écarteur avec douilles
Câche douilles de raccordement
Référence
C71413821
C71413811
C71413831
C71413801
C14058810
C71413781
C71413901
Prix € HT
72
72
72
72
90
90
60
Thermostats d’ambiance
Thermostat
Référence
Prix € HT
Thermostat d’ambiance digital sans fil
CFF000025
231
Thermostat d’ambiance filaire
CFF000028
104
Thermostat digital avec programme hebdomadaire liaison radio
• Boitier pour fixation murale en saillie ou boite d'encastrement.
Positionnement sur pied possible (socle fourni)
• Affichage sur grand écran LCD rétro éclairé
• Fonctionnement sur piles 2x1,5V (fournies)
• Sauvegarde permanente des paramètres de réglage
• Protection classe III IP30
• Réglages par molette 7 positions et touches élastomères
Chaudières murales 59
MURALES
LUNA ST / LUNA ST
Collectif murales 2014_Mise en page 1 19/02/14 15:41 Page60
LUNA ST / LUNA ST
COMPOSANTS
CODE
DESIGNATION
CORPS
CHAUDIÉRE
BARRETTE
ROBINETTERIE
CLUS124CF0
Luna ST Prime 1.24 CF
CCPA45124
C14077810
CLUS124FFH
Luna ST Prime 1.24 FFH
CCPA45524
C14077810
CLUS124FF0
Luna ST Prime 1.24 FFV 100
CCPA45524
C14077810
CLUS124FF5
Luna ST Prime 1.24 FFV 125
CCPA45524
C14077810
CLUS224CF0
Luna ST Flirt 2.24 CF
CCPA45224
C14068011
CLUS224FFH
Luna ST Flirt 2.24 FFH
CCPA45624
C14068011
CLUS224FF0
Luna ST Flirt 2.24 FFV 100
CCPA45624
C14068011
CLUS224FF5
Luna ST Flirt 2.24 FFV 125
CCPA45624
C14068011
CLUS224VMC
Luna ST Flirt 2.24 VMC
CCPA45224VMC
C14068011
CLUSC24CF0
Luna ST Compact 2.24 CF
C71100370
C71413761
CLUSC24FFH
Luna ST Compact 2.24 FFH
C71100390
C71413761
CLUSC24FF0
Luna ST Compact 2.24 FFV 100
C71100390
C71413761
CLUSC24FF5
Luna ST Compact 2.24 FFV 125
C71100390
C71413761
CLUSC24VMC
Luna ST Compact 2.24 VMC
C71100380
C71413761
CLUS24CFO
Luna ST Max 2.24 CF
CCPA45324
C14068011
CLUS24FFH
Luna ST Max 2.24 FFH
CCPA45824
C14068011
CLUS24FFO
Luna ST Max 2.24 FFV 100
CCPA45824
C14068011
CLUS24FF5
Luna ST Max 2.24 FFV 125
CCPA45824
C14068011
CLUS24VMC
Luna ST Max 2.24 VMC
CCPA45324VMC
C14068011
CLUS324CF0
Luna ST Duo 3.24 CF
CCPA45424
C14073711
CLUS324FFH
Luna ST Duo 3.28 FFH
CCPA45728
C14073711
CLUS324FF0
Luna ST Duo 3.28 FFV 100
CCPA45728
C14073711
CLUS324FF5
Luna ST Duo 3.28 FFV 125
CCPA45728
C14073711
CLUS324VMC
Luna ST Duo 3.24 VMC
CCPA45424VMC
C14073711
COUDE
TERMINAL
CONCENTRIQUE
CONCENTRIQUE
90°
COMPOSANTS
CODE
C71410181
C14017710
C14036410
C71410191
CFF000007
C71410141
C71410181
C14017710
C14036410
C71410191
CFF000007
C71413791
C71410141
C71410181
C14017710
C14036410
C71413791
C71410191
C71413791
CFF000007
C71413791
C71413791
C71410141
C71410181
C14017710
C14036410
C71410191
CFF000007
C71410141
C71410181
C14017710
C14036410
C71410191
CFF000007
CORPS
BARRETTE
ROBINETTERIE
COUDE
CONCENTRIQUE
90°
TERMINAL
CONCENTRIQUE
ROSACE
Ø100
C14059710
C14059610
C14017710
DESIGNATION
CLCS28HTH
LUNA ST 2.28 HTE H
CHLA43628
C14068011
CLCS28HTV
LUNA ST 2.28 HTE V
CHLA43628
C14068011
CLCS33HTH
LUNA ST 2.33 HTE H
CHLA43633
C14068011
CLCS33HTV
LUNA ST 2.33 HTE V
CHLA43633
C14068011
60 Chaudières murales
C71410141
ADAPTATEUR DOUILLES
SORTIE
INSTALLATION
VERTICALE
NEUVE
ROSACE
Ø100
ADAPTATEUR
SORTIE
VERTICALE
CFF000019
C14059710
C14059610
C14017710
CFF000019
Collectif murales 2014_Mise en page 1 19/02/14 15:41 Page61
LUNA ST
10
10
22
44
11
44
33
Luna ST sortie horizontale
44
11
11
44
11
11
3
3
22
Luna ST sortie horizontale
44
44
10
10
Luna ST sortie horizontale
66
221
22
44
44
44
44
11
11
44
11
11
44
11 11
11
11
11
11
6
6
8
8
77
Luna ST sortie toiture droite
Luna ST sortie toiture droite
Luna ST sortie toiture droite
Raccordement ventouses Luna ST Compact Ø 60 / 100
22
66
77
L max 24 kW = 4 m
44
11
44
33
L max = 3 m
Accessoires ventouse concentrique
Coude concentrique à 90° Ø 100 additionnel
Coude concentrique à 90° Ø 100 départ chaudière sur version H
Rallonge concentrique 1m Ø 100
Rosace intérieure Ø 100
Coude concentrique à 45° Ø 100
Terminal vertical concentrique Ø 100
H
Déflecteur pour chaudière murale
Adaptateur départ vertical Ø 100
Grille de protection
J
I
44
44
10
L max 24 kW = 3 m 10
Luna ST Compact sortie horizontale
Repères
Référence
Prix € HT
10
C71410181
2
4
C71410151
74
43
C71410141
43
C71410171
51
3
5
6
7
8
C71410391
38
C14017710
11
C71410161
40
C14036410
177
C14036610
67
9
C14036710
52
CFF000007
53
11
CFF000016
34
4
Rallonge concentrique 0.50 m Ø 100
Adaptateur sortie verticale Ø 80/125 sur version verticale
22
1
Terminal horizontal concentrique Ø 100 sur version H
Solin pour toit plat Ø 100
44
11
11
Luna ST Compact sortie toiture droite
Luna ST Compact sortie horizontale
Solin pour toit incliné Ø 100
11
44
C71410191
43
CFFVF0009
126
Chaudières murales 61
MURALES
Raccordement ventouses Luna ST Ø 60 / 100
Collectif murales 2014_Mise en page 1 19/02/14 15:41 Page62
LUNA ST
Raccordement ventouses des chaudières à condensation
Ø 60 x 100 et 80 x 125
Les différents types d’installation
Installation à raccordement horizontal en ventouse Ø 60 x 100 type C13
9m
9m
4
3
5
4
2
4
2
4
2
4
2
4
1
1
3
5
Luna ST HTE sortie horizontale
1
4
2
3
9m
3
Luna ST HTE sortie latérale
Luna ST HTE sortie horizontale
Luna ST HTE sortie horizontale
3 Coude concentrique à 90°
5 Coude concentrique à 45°
Ø 100 code : C14059710
Ø 100 code : C14059810
Terminal horizontal concentrique Ø 100
code : C14059610
4 Rallonge concentrique 1 m
Accessoires murales
Condensation - Accessoires ventouse concentrique
Diamètre 60 x 100
2 Terminal horizontal 750 mm Ø 60 x 100
3 Coude 90° Ø 60 x 100
5 Coude 45° Ø 60 x 100
4 Rallonge 1000 mm Ø 60 x 100
Diamètre 80 x 125
Adaptateur Ø 60 x 100 - 80 x 125
Diamètre 100
1 Rosace intérieure Ø 100
Rosace étanche maison type BBC
Accessoires ventouse biflux
Séparateur biflux 60 x 60
Réduction 60 x 80
o = option
62 Chaudières murales
3
9m
Rosace intérieure
Ø 100 code : C14017710
f = fourni
4
Ø 100 code : C14059510
Initia HTE 24 à 33 kW
Référence
f
o
o
o
C14059610
C14059710
C14059810
C14059510
o
CFF000019
o
o
C14017710
CFFUA002
o
o
C14059110
C14075610
Collectif murales 2014_Mise en page 1 19/02/14 15:41 Page63
LUNA ST
Accessoires de raccordement Luna ST HTE Ø 80/125
Exemple sur cheminée existante :
conduit rigide
Exemple d’installation ventouse type C33
avec des conduits verticaux Ø 80/125
Exemple sur cheminée existante :
conduit flexible
5
9
16
6
13
11
10
12
4
4
3
1
Pour installation
cheminée B33
3
80
80
80
80
80
80
13
10
• La hauteur maxi L1 du conduit
vertical est : 20 m,
• La longueur maxi L2 + L3 du
raccordement horizontal est : 2 m,
• La solution retenue sera soit un
conduit rigide sur toute la hauteur,
soit un conduit souple sur toute la
hauteur (solution mixte interdite),
Conduits
3 CEP
16
16
4
16 Coude clapet
80/125 3CEP,
Référence : CFFUB0001
Prix Public : 129 € HT
Longueur L max
Nous Consulter
10
4
10 12
• Prévoir 1 écarteur sous chaque
emboîtement femelle (tuyau
rigide) ou tous les 2 m maximum.
Diamètre
125
125
80
80
80
80
80
80
80
80
80
80
80
80
Pour installation
cheminée B33
8 3
10
• La longueur équivalente verticale droite
maxi est : L = 18 m, La longueur équivalente horizontale
droite maxi est : 6 m,
• Pour toutes les parties horizontales, donner une pente de 5%
vers la chaudière,
• La longueur équivalente droite est égale à la somme des
longueurs droites + les longueurs équivalentes des coudes :
1 coude à 90° = 1 m
1 coude à 30° = 0,35 m
1 coude à 45° = 0,5 m
1 coude à 15° = 0,2 m
• Les rallonges droites ( 3 ) de 0.25, 0.5, 1 ou 2 m peuvent
être coupées à la longueur souhaitée. La coupe doit être faite
sans déformation et ébavurée.
Accessoires cheminée étanche type B33-C33
16 Prise d'air pour installation cheminée B33
10 Plaque de finition, Ø 125 pour installation ventouse C33
13 Kit de raccordement cheminée tube Ø 80 flexible*
9 Kit de raccordement cheminée tube Ø 80 rigide*
Coude 15°, Ø 80 PPs
Coude 30°, Ø 80 PPs
Coude 45°, Ø 80 PPs
Coude 87°, Ø 80 PPs
12 Rallonge 2000 mm, Ø 80 PPs
12 Rallonge 1000 mm, Ø 80 PPs
12 Rallonge 500 mm, Ø 80 PPs
Élément T pour accès maintenance, Ø 80 PPs
Ouverture pour accès maintenance, Ø 80 PPs
11 Écarteur Ø 80 pour tuyau rigide
Grille d'aération
Aide pour insertion du tuyau flexible Ø 80
Ouverture pour accès maintenance, du tuyau flexible Ø 80
Coupleur pour tuyau flexible Ø 80
14 Écarteur pour tuyau flexible Ø 80
15 Tuyau de fumées flexible Ø 80 PPs rouleau 25 m
15 Tuyau de fumées flexible Ø 80 PPs rouleau 12,5 m
15
Pour installation
Ventouse C33
9
8 3
16
14
Référence
CRN941525
CRN556320
CRN998055
CFF000020
CRN994903
CRN994897
CRN994873
CRN994866
CRN994859
CRN994842
CRN994835
CRN994828
CRN994811
CRN956529
CRN578462
CRN998116
CRN998109
CRN998093
CRN998086
CRN998079
CRN998062
Accessoires ventouse type C13-C33
5 Terminal ventouse vertical couleur brique 80/125 PPs/AL (1)
5 Terminal ventouse vertical couleur noire 80/125 PPs/AL (1)
3 Rallonge 2000 mm, Ø 80/125 PPs/AL
3 Rallonge 1000 mm, Ø 80/125 PPs/AL
3 Rallonge 250 mm, Ø 80/125 PPs/AL
3 Rallonge 500 mm, Ø 80/125 PPs/AL
8 Té à 90° avec accès maintenance Ø 80/125 PPs/AL
Élément droit avec accès maintenance Ø 80/125 PPs/AL
4 Coude 15°, Ø 80/125 PPs/AL
4 Coude 30°, Ø 80/125 PPs/AL
4 Coude 45°, Ø 80/125 PPs/AL
1 Coude 90°, Ø 80/125 PPs/AL
6 Solin pour toit en pente 25° - 45° couleur brique
6 Solin pour toit en pente 25° - 45° couleur noire
7 Solin pour toit plat
Collier Ø 125
Diamètre
Référence
80/125
80/125
80/125
80/125
80/125
80/125
80/125
80/125
80/125
80/125
80/125
80/125
80/125
80/125
80/125
125
CRN994781
CRN994774
CRN995535
CRN994927
CRN994934
CRN994910
CRN994996
CRN994989
CRN994972
CRN994965
CRN994958
CRN994941
CRN907224
CRN578646
CRN578639
CRN578622
(1) obligatoire pour ventouse verticale. * 1 chapeau de gaine, 1 coude avec rail, 4 écarteurs.
Type CRN : conduit sous avis technique ISOCOX
Chaudières murales 63
MURALES
Installation à raccordement vertical Ø 80 x 125 en ventouse type C33 et cheminée type B33
Collectif murales 2014_Mise en page 1 19/02/14 15:41 Page64
LUNA ST / LUNA ST
Règles d’implantation
OBLIGATIONS
RECOMMANDATIONS
A = 0,40 m : distance minimum de l’axe de l’orifice d’évacuation
des gaz brûlés à toute ouverture.
D = 0,30 m : entraxe de l’orifice d’évacuation des gaz brûlés au
sol et/ou au débord du toit ou au-dessus d’un
balcon.
B = 0,60 m : distance minimum de l’axe de l’orifice d’évacuation
des gaz brûlés à tout autre orifice de ventilation.
C = 1,80 m : les orifices d’évacuation débouchant directement
sur une voie de circulation extérieure, voie publique
ou privée à moins de 1,80 mètre au-dessus du sol,
hormis pour les appareils à condensation, doivent
comporter un déflecteur inamovible donnant aux
gaz évacués une direction sensiblement parallèle
au mur.
Les orifices d’évacuation et de prise d’air des appareils à circuit
étanche débouchant à moins de 1,80 mètre au dessus du sol
doivent être protégés efficacement contre toute intervention extérieure susceptible de nuire à leur fonctionnement normal.
Distance entre 2 ventouses 0,60 m.
Les distances indiquées ont pour départ l’axe de l’orifice d’évacuation des gaz brûlés.
64 Chaudières murales
E = 1,50 m : entraxe de l’orifice d’évacuation des gaz brûlés à un
mur à 90°, avec fenêtre ou orifice de ventilation.
F = 0,80 m : entraxe de l’orifice d’évacuation des gaz brûlés à un
mur à 90°, sans ouverture.
G = 2,00 m : distance de l’orifice d’évacuation des gaz brûlés à
une haie ou plantation.
H = 0,10 m : entraxe de l’orifice d’évacuation des gaz brûlés à
une gouttière ou une tuyauterie verticale.
Collectif murales 2014_Mise en page 1 19/02/14 15:41 Page65
MURALES
NOTES
Chaudières murales 65