thermostat tp520
Transcription
thermostat tp520
THERMOSTAT TP520 IMPORTANT INFORMATION FOR SAFE USAGE 1 CONTROLS AND SETTINGS 2 DISPLAY STRUCTURE 2 SET DAY AND TIME CONTENT 3 EVENT TIME PROGRAMMING 4 TEMPERATURE RANGE PROGRAMMING 6 SCREENSAVER 6 SELECT OPERATION MODE 7 ALARM INDICATION 7 TECHNICAL DATA 8 LINE DIAGRAM 8 MENU STRUCTURE 8 WARRANTY 8 IMPORTANT INFORMATION FOR SAFE USAGE Manufacturer's guarantee does not cover malfunctions caused by mechanical damage, improper installation, or exploitation for purposes, or under conditions, not provided by the User- and Installation Manual. Please keep in mind that the Installation Manual and the Connection Diagram are no replacement for the professional skill of the device installer. We recommend that you apply for professional service for the thermostat and heating system installation. Only qualified electricians should perform the connections and power networking of the device. Switch off power before connecting wiring to the thermostat or disconnecting the device for testing. Introduction Thank you for choosing the TP 520 electronic regulation device, the new intelligent heating control system. With this product you will see how easy it is to maintain your comfort at a lower cost; it will take care of keeping your home warm and cozy all the time. Designed with innovation and inspiration, the new thermostat is highly reliable, and easy to set and use. Separate settings can be programmed for different times of the day, whether or in or out. Application The thermostat TP520 is designed to control underfloor heating systems (heating mats, sections, film heaters). The thermostat maintains comfortable heating temperature and saves energy. CONTROLS AND SETTINGS Hands are used, if it is necessary to push several butons together or push buttons for longer time PROG/ESC MODE/OK 1 4 1 - 2 PROG / ESC 3 MODE /OK 4 + To start the described action, the marked button must be pushed 3 2 decrease the values enter the programm mode and EXIT switch the indication & set limits and modes increase the values Temperature settings DISPLAY STRUCTURE Comfort modus, temp. adjustable Economy modus, temp. adjustable SET PROG DATE TIME TEMP Programm modes Operation modes 28,0 C freeze protection mode 1 „WAKE UP“ constant temperature maintenance 2 „LEAVING HOME“ programm mode 3 „COMING HOME“ MO TU heating on 4 „GOING TO SLEEP“ 1 WE TH 2 FR SA 3 SU 4 Other Thermostat is locked Confort temperature Minimum temperature Comming home Wake up Leaving home Going to sleep During the „COMFORT“ period the desired comfort temperature will be maintained. MO Monday TU Tuesday WE Wednesday TH Thursday FR Friday SA Saturday SU Sunday During the „ECONOMY“ period the temperature will be reduced to the desired minimum temperature to safe energy. INSTALLATION RESERVATION Technical data are subject to change without notice. Changes, errors and printer's errors do not justify claims for damages. For safety components and systems the relevant standards and regulations are to be observed, as well as the corresponding operating and installation instructions. 2 ME SET DAY AND TIME - PROG/ESC MODE/OK + 8 sec. ENTER THE PROGRAMMING 1 2 Unlock the thermostat TEMP Press and hold the PROG/ESC button for 8 seconds DATE & TIME SET 19,0 C WE WE PROG/ESC MODE/OK PROG/ESC MODE/OK 8s SET DAY 3 Press the MODE/OK button. The „Day of the week symbol“ will start to blink DATE SET 4 DATE SET MO Set the actual day of the week with the “+” or “–” button. Confirm the selection with MODE/OK button. TU PROG/ESC MODE/OK DATE SET TU PROG/ESC MODE/OK PROG/ESC MODE/OK SET TIME 5 Set the required hour with the “+” or “–” button. Confirm the selection with MODE/OK button. Now the minutes procedure start. TIME SET 12 00 WE PROG/ESC MODE/OK 6 Set the required minutes with the “+” or “–” button. Confirm the selection with the MODE/OK button. The „Day and time setting“ procedure is completed. TEMP TIME SET 12 40 19,0 C TU WE PROG/ESC MODE/OK 3 EVENT TIME PROGRAMMING OGRAMMING - PROG/ESC MODE/OK + 4 sec. ENTER THE PROGRAMMING 1 2 Unlock the thermostat TEMP Press and hold the PROG/ESC button for 4 seconds DATE & TIME SET 19,0 C WE WE PROG/ESC MODE/OK PROG/ESC MODE/OK 4s WAKE UP EVENT 1 3 Press the MODE/OK button. The „Time symbol“ starts blinking. SET PROG TIME Set your WAKE UP time with “+” and “–” buttons. Confirm the selection with the MODE/OK button. 4 SET PROG TIME SET PROG 07 , 40 07 , 00 PROG/ESC MODE/OK Press the MODE/OK button. The time will start to blink SET PROG TIME 08 , 00 MO 7 PROG/ESC MODE/OK 1 Set your GO OUT time with “+” and “–” buttons. Confirm the selection with the MODE/OK button. SET PROG PROG/ESC MODE/OK LEAVING HOME EVENT TIME SET PROG 08 , 30 TEMP 08 , 30 MO MO 2 07 , 40 PROG/ESC MODE/OK 2 6 TEMP MO 1 PROG/ESC MODE/OK Set the modus COMFORT with the “+” or “–” button. SET PROG MO 1 1 TEMP 07 , 40 MO MO 5 PROG/ESC MODE/OK PROG/ESC MODE/OK 4 Set the modus ECONOMY with “+” or “–” button. SET PROG TEMP 08 , 30 MO 2 2 8 2 PROG/ESC MODE/OK EVENT TIME PROGRAMMING OGRAMMING - + PROG/ESC MODE/OK 4 sec. COMING HOME EVENT 3 Press the MODE/OK button. The time will start to blink 9 SET PROG TIME 10 Set your COMING HOME time with “+” and “–” buttons. Confirm the selection with the MODE/OK button. SET PROG 19 , 00 TIME SET PROG 19 , 30 MO 3 PROG/ESC MODE/OK PROG/ESC MODE/OK GOING TO SLEEP EVENT 4 Press the MODE/OK button. The time will start to blink 12 SET PROG TIME 13 Set your GOING TO SLEEP time with “+” and “–” buttons. Confirm the selection with the MODE/OK button. SET PROG 22 , 00 MO SET PROG TIME TEMP Set the modus ECONOMY with “+” or “–” button. TEMP 22 , 30 MO 4 14 SET PROG 22 , 30 22 , 30 MO PROG/ESC MODE/OK 19 , 30 3 3 PROG/ESC MODE/OK TEMP MO MO 3 Set the COMFORT modus with “+” or “–” button. SET PROG TEMP 19 , 30 MO PROG/ESC MODE/OK 11 MO 4 4 PROG/ESC MODE/OK 4 PROG/ESC MODE/OK PROG/ESC MODE/OK After setting the desired modus in the Step 14 press the MODE/OK button. The thermostat will proceed to set up the time for Wake-up event for the next day of the week (TUESDAY) - please repeat the setting from step3 - 14 for all other days. OPERATION SCHEME DESCRIPTION ANTI - FREEZING This mode is suitable to keep minimum positive temperature in the premise while nobody inside for a long time. The temperature is adjustable from +5°C up to +12°C. CONSTANT TEMPERATURE MODE The thermostat constantly maintains the desired floor temperature. The temperature is adjustable from +12°C up to +35°C. PROGRAM MODE Depending on time and day of the week the thermostat automatically switches the „Comfort“ or „Economy“ floor temperature modus depending your selections. The temperature is adjustable from +12°C up to +35°C. DEFAULT SETTINGS Day Event Time Temperature level Time Saturday and Sunday Temeparture level Monday to Friday 1 2 3 4 7:00 8:00 19:00 22:00 7:00 8:00 19:00 22:00 5 TEMPERATURE RANGE PROGRAMMING ANGE PROGRAMMING - PROG/ESC MODE/OK + 8 sec. ENTER THE PROGRAMMING 1 Unlock the thermostat 2 Press and hold the MODE/OK button for 8 seconds. The symbol for the „ECONOMY MODUS“ apears and the temperature starts with blinking. TEMP TEMP SET 19,0 C 19,0 C WE WE PROG/ESC MODE/OK PROG/ESC MODE/OK TEMPERATURE SETTINGS 3 During the „ECONOMY MODUS“ the temperature will be reduced to your desired minimum temperature. Set the desired „ECONOMY MODUS TEMPERATURE“ with the “+” or “–” button. Confirm the selection with MODE/OK. Now the „COMFORT MODUS TEMPERATURE“ could be adjusted on the same way. Confirm the selection with MODE/OK. Setup is completed and the Display shows the actual temperature. TEMP SET 20,0 C MO SET TEMP SET 22,0 C 25,0 C MO PROG/ESC MODE/OK TEMP MO PROG/ESC MODE/OK PROG/ESC MODE/OK SCREENSAVER - PROG/ESC MODE/OK + 2 sec. SELECT SCREENSAVER 1 Unlock the thermostat 2 The default screensaver is “Floor temperature”. Press and hold MODE/OK key for 2 seconds. The screensaver will change to “Current time” 3 If you press and hold MODE/OK key for 2 seconds again, the screensaver will change back to “Floor temperature” TEMP TEMP TEMP 19,0 C WE PROG/ESC MODE/OK 7 40 WE 19,0 C WE PROG/ESC MODE/OK 6 PROG/ESC MODE/OK ON SELECT MODEOPERATION MODE - PROG/ESC MODE/OK + 4 sec. ENTER THE PROGRAMMING 1 Press and hold MODE/OK button for 4 seconds. 2 The operation scheme indicator will start to blink Unlock the thermostat TEMP SET 19,0 C 19,0 C WE WE PROG/ESC MODE/OK PROG/ESC MODE/OK 4s OPERATION MODE SELECTION 3 Set the operation scheme with the “+” or “–” button. 4 Confirm the selection with MODE/OK. The scheme is set. SET SET 19,0 C 19,0 C WE WE PROG/ESC MODE/OK PROG/ESC MODE/OK ALARM INDICATION ALARM INDICATION 1 Display apears in case if the heating system fails to heat the surface to more than +5°C or in case of surface overheating by more than +45°C occurs. TEMP HI C WE PROG/ESC MODE/OK 2 Display apears in case of SENSOR FAILURE TEMP LO C WE -- -WE PROG/ESC MODE/OK 7 PROG/ESC MODE/OK TECHNICAL DATA LINE DIAGRAM Power supply 230VAC, 60Hz Maximum load current 16A Thermostat power consumption 450 mW Weight 150 g Dimensions 86x86x35 mm IP rate IP21/IP31 Protection class II Floor temperature sensor (TST02) NTC 6,8 kOhm Sensor cold lead length 2m Ambient air temperature range from +5°Ñ to +40°Ñ Maximum humidity 80% Temperature setting range from +5°Ñ to +35°Ñ Color White 3 L 1 2 4 N 5 N 6 L t Sensor 230 VAC Load (Heating) MENU STRUCTURE - 1x PROG/ESC MODE/OK - + Exit without saving 1x PROG/ESC MODE/OK + Confirm settings 4 sec Event time programming 2 sec Screensaver selection 8 sec Set date 4 sec Operation mode selection 8 sec Set temperature PRECAUTIONS Switch off power from all wiring before installing, testing or replacing the thermostat. Only qualified electricians are allowed to work on electrical connections and the electric supply of the device. Otherwise the warranty invalidates. Only use plastic wall mounting boxes for the thermostat installation. WARRANTY The producer guarantees that the thermostat TP520 is free from defects caused by manufacturing techniques or by using of poor materials. Warranty period – 2 years from date of purchase. In case of a failure during the warranty period because of faulty manufacturing despite correct executed installation (according to manual) the customer has the right to get the product repaired or replaced. The warranty does not cover any damages due to inadequate handling, damages through third party fault, wrong installation (not following the manual) or its consequential damages. Please keep your receipt. For any warranty claims you have to show your sales receipt. CLAIMS In case of failure during the warranty period please contact the manufacturer service center or the regional authorized representative. ACCEPTANCE TEST CERTIFICATE The thermostat TP520 passed the test. Name: Street: ZIP code, city: Country: Phone: E-Mail: Date of purchase: Installer: Installation date: installer: Signature Ducasa Venezuela, 33 08019 Barcelona 8 Tel.: +34 932478630 Fax: +34 932455781 [email protected] www.ducasa.com