High-Power Digital TV Transmitter
Transcription
High-Power Digital TV Transmitter
DTU-52 Series High-Power Digital TV Transmitter Features • Small footprint - 590 (W) x 2,000 (H) x 1,000 (D)mm for 8.7kW • High efficiency - Excellent broadband matching circuit at amplifier modules • New TRPA -UA4000QE - Using the latest high-power LDMOS - Output power of TRPA is 1kW average and/or 2kW at sync peak 1st Edition NEC leads the digital TV broadcasting industry around the world NEC is a leading global company which offers world-class know-how and resources in the technology of broadcasting networks. O ur n ewest model of d i g i t a l T V t r a n s m i t t e r The continued evolution and integration of broadcast technology led us to develop a new high-power Transistor Power Amplifier (TRPA) designated UA4000QE which our new high-power digital TV ▲ transmitter, the DTU-52 series, utilizes. DTU-52 8.7kW Model DTU-52/8R7PQ The DTU-52 series inherits the technologies and performance of previous model DTU-51, which has been highly evaluated in the field widely, and adds innovative new technology. This realizes even higher reliability in a high-quality digital TV transmitter. Besides the two main features — high reliability and low maintenance — of our existing digital TV transmitters, we have successfully achieved two additional advantages — high efficiency and a small footprint — for this new DTU-52 series. Hi gh e ff iciency By adopting this new TRPA, the DTU-52 series enables a reduction in power consumption by an average of 20 to 30% compared with previous models. Small fo ot pr int The DTU-52 series provides up to 8.7kW output power (average) by using 10 sets of TRPA units in a single rack, achieving a footprint of only 590 (W) x 2,000 (H) x 1,000 (D)mm, one of the smallest in the world. The latest in digital broadcasting technology Powe r A mplif ier s (PA ) Our newly developed high-power TRPA, the UA4000QE, utilizes the latest high-power LDMOS. The output power of this TRPA is 1kW average. It features an excellent broadband matching circuit in the amplifier modules. • Size 479 (W) x 105 (H) x 630 (D)mm • Internal power supply • Can easily be replaced during operation • Monitoring and remote control The compact PA modules each incorporate an RS-485 interface, enabling comprehensive monitoring and remote control. Furthermore, self-protection circuits for high temperature, reflected power, overvoltage, overcurrent and low AC voltage are built-in. UA4000QE Wid eband design cove r s e n t i r e U H F b a n d Frequency-agile, so no channel-specific components are necessary. ■ Exciter The DM-3000A digital exciter is packed with NEC’s state-of-the-art technologies. The integration of numerous functions into a single unit greatly reduces size and cost. A synthesizer tuned to all UHFband signals enables all-band direct conversion to an RF output. Higher or lower bit rates are modified to usable bit rates for flexible bit-rate adaptability. Using the MIR created by the SFN adapter, seamless ASI switching can be performed. The truly impressive characteristic of the DM-3000A is its ability to work in conjunction with other NEC transmitters as a signal processor — this greatly reduces the necessity for spare units while simplifying maintenance. DM-3000A ■ Adaptive Digital Corrector (ADC) (optional) The ADC board automatically generates correction factors of non-linearity distortion and updates the correction table without interrupting program service. Optimum signal quality and service coverage are maintained, protected from the effects of ambient temperature, aging and other factors. The ADC board is installable from the front of the exciter and can be used to generate the correction factor for preset correction. Furthermore, the ADC board is capable of analyzing feedback signals from the TX output, including intermodulation level, MER value and other graphical data. And automatic adjustment of the IMP/MER values greatly reduces the time required for maintenance. Removable ADC board (optional) ■ N+1 System The Versatile III Series DTU-52’s frequency-agile design allows for the construction of an N+1 system, offering redundancy for maximized reliability and uptime. By using the newly developed N+1 controller, up to 8+1 system is available. At any given site, there is a transmitter ready to be activated should one of the active transmitters malfunction. When activated, the spare transmitter adjusts its frequency band accordingly without interfering with broadcast signals. ■ Liquid Cooling The liquid cooling system incorporates an automatic air-purge function, and an Adaptive Fault Forecast function. These features work together to cut noise and installation costs, make maintenance easier and boost reliability. Coolant feeding and dust removal have been greatly simplified by a hybrid closed circuit, ensuring the coolant remains clean. Liquid Cooling System (Single with redundancy) Fan 1 M Fan 2 M Fan 3 M Heat Exchanger Passive Reserve (Reserve) LS TS TS Water/ Water/ Glycol glycol FM PS PA Pump A PA PA Pump B PA Passive Reserve Transmitter Pump Rack FM: Flowmeter LS: Level Switch M: Motor PS: Pressure Switch TS: Thermal Switch Remo te C ont r ol/Mon i t o r i n g The easy-to-view color LCD screen located on the front of the rack features an intuitive GUI (Graphical User Interface), making transmitter control, monitoring and maintenance extremely easy to perform. For monitoring and control capabilities of a single or multiple transmitters from different locations, NEC offers SNMP and Web server. TCP/IP PC Sample View of Signal Quality Monitoring IP Network DTU-52 Series Transmitter C on fig ur at ion of D T U - 5 2 ( L i q u i d - c o o l e d ) S e r i e s D TU -52 S e r i e s L i n e u p DTU-52/ 1 2 3 1 2 : Output Power Type R9 1R8 2R7 3R6 4R4 5R3 6R2 7R0 7R8 8R7 10R0 Output Power 900W 1.8kW 2.7kW 3.6kW 4.4kW 5.3kW 6.2kW 7.0kW 7.8kW 8.7kW 10.0kW : System Type S: Single Transmitter with Single Drive P: Single Transmitter with Dual Drive and Multiple PAs PE: Single Transmitter with Dual Drive and Single PA 3 : Cooling Type Q: Liquid Cooling Transmi t t e r S t a n d a r d Co n f igurati on S Type Exciter Adaptive Digital Corrector Local OSC RF Converter TRPA 1 PS n-Combiner OFDM Encoding n-Divider TS Input 1 TS Input 2 TRPA 2 TRPA n External Reference Input Control Remote Control/ SYS.CONT AC Input BPF (Option) Output Status Pump Rack & H.EXC TX CONT LCD Display P Type Local OSC RF Converter PS External Reference Input TS Input 1 TS Input 2 TRPA 1 n-Combiner Exciter 1 Adaptive Digital Corrector Exciter Switch OFDM Encoding n-Divider TS Input 1 TS Input 2 TRPA 2 TRPA n BPF (Option) Output Exciter 2 Control Remote Control/ SYS.CONT AC Input Status TX CONT LCD Display Pump Rack & H.EXC Transmi t t e r S t a n d a r d Co n f igurati on Tabl e Output 900W 1.8kW 2.7kW 3.6kW 4.4kW 5.3kW 6.2kW 7.0kW 7.8kW 8.7kW 10.0kW Model Name DTU-52/R9SQ DTU-52/R9PEQ DTU-52/1R8SQ DTU-52/1R8PQ DTU-52/2R7SQ DTU-52/2R7PQ DTU-52/3R6SQ DTU-52/3R6PQ DTU-52/4R4SQ DTU-52/4R4PQ DTU-52/5R3SQ DTU-52/5R3PQ DTU-52/6R2SQ DTU-52/6R2PQ DTU-52/7R0SQ DTU-52/7R0PQ DTU-52/7R8SQ DTU-52/7R8PQ DTU-52/8R7SQ DTU-52/8R7PQ DTU-52/10R0SQ DTU-52/10R0PQ Equipment Composition (Sets) Transmitter Exciter Exciter Switch PA Divider/Combiner TX Control 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 1 1 1 1 1 1 1 1 1 1 1 2 3 4 5 6 7 8 9 10 12 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Rack 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 Size (mm) 590(W) x 2,000(H) x 1,000(D) 1,180(W) x 2,000(H) x 1,000(D) Weight 359 367 407 415 447 455 487 495 528 536 568 576 608 616 649 657 690 698 730 738 1,166 1,174 E xte rnal View *Drawings are for P type. For S type, the exciter will be one set. EXCITER-A EXCITER-A EXCITER-A EXCITER-B EXCITER-B EXCITER-B EXCITER-B TX CONT TX CONT TX CONT TX CONT DTU-52/R9PEQ DTU-52/1R8PQ EXCITER-A EXCITER-A DTU-52/3R6PQ EXCITER-A EXCITER-A EXCITER-B EXCITER-B EXCITER-B EXCITER-B TX CONT TX CONT TX CONT TX CONT DTU-52/4R4PQ DTU-52/5R3PQ EXCITER-A DTU-52/7R8PQ DTU-52/2R7PQ EXCITER-A DTU-52/6R2PQ EXCITER-A EXCITER-A EXCITER-B EXCITER-B EXCITER-B TX CONT TX CONT DTU-52/8R7PQ DTU-52/7R0PQ TX CONT DTU-52/10R0PQ S pecif ication s a n d Pe r f o r ma n c e DTU-52 (Liquid-cooled) Series Specifications Output Power Output Frequency Output Impedance Input Signal Power Supply Voltage Voltage Fluctuation Power Supply Frequency Ambient Temperature Relative Humidity Standard Performance Frequency Stability Amplitude-frequency Response Intermodulation Products MER (Modulation Error Ratio) Spurious 900W ~ 10kW 470 ~ 862MHz (Band IV/V) 50Ω DVB-ASI 380/400/415V, 3-phase, 4-wire +10%, -15% 50/60Hz±2% Indoors: 0°C ~ +45°C Outdoors: 0°C ~ +45°C or -30°C ~ +40°C (using antifreeze and 3-way valve system) < = 90% (no condensation) < = ±1 X 10-7 (internal reference use) (it is also possible to lock to an external 10MHz reference) < = ±0.5dB (excluding BPF) < = -36dB > = 32dB < = -60dBc Specifications, designs, etc. are subject to change without notice.For further information, please contact: 1EC Australia Pty. Ltd. Broadcasting Systems 649-655 Springvale Road, Mulgrave, Victoria 3170, Australia Tel: +61 (0)3 9262-1111 Fax: +61 (0)3 9264-3507 DX.QHFFRP Cat. No. BBV064 1st 0808 08080000KK Printed in Japan ©NEC Corporation 2008