motor for pool cover

Transcription

motor for pool cover
motor for pool cover
12 volts
DC
Above ground motorisation
12 volts MHS Motor
M.H.S.
•A solution for each dimension:
we adapt the flanges to the diameter of
your tubes
•Automatic opening management of the
pool:
Setting up of the speed and torque in one
single operation with the position limit
switch.
Technical features:
indice
•Torque motorisation: 140 Nm
Date
Auteur
Responsable
Modifications
Traitement:
•Gear ratio: 1/357
•Motor: 12 volts DC
•Speed: 2,8 RPM
Volume : 1 998 007,98 cm³
Dossier
Masse : 4,51 kg
Dossier
M.H.S.
Matière:
Dessiné:
G. Degottex
Plan d'encombrement
:0x-xxx
Tol.géné.: iso 2768 mK Ra général : 3.2µ
F -01708- St Maurice de Beynost
Echelle: Remplace:
3:4
...
Code Article:
Date:
N° : A2-ND-2940-1-
Motorisation dimensions
•IPx5
26
16
of flange adapted
72
How to initialize the system ?
44
32
362
1. Press on the Init button for 10 seconds
2. Bring the cover in opened position
3. Bring the cover in closed position
25
20,5
4. Close again the cover and it’s ready to use
2 holes
7
Without flange
Solar electric power supply in option
Battery 7,2 A.h
ti
s
Charger
r
ct
Fo
sa
S olu
s
SI
EM
Solar panel 5W or 10W
on
R
fer prod
u
NON CONTRACTUAL PHOTOGRAPHS AND DIAGRAMS
Date: 26/05/05
Vérifié par :
Folio : 1/1 E. Putoud
w w w. s i r e m . f r
S I R E M - C h e m i n d u P i l o n - 0 1 7 0 0 - S T M A U R I C E D E B E Y N O S T - F R A N C E Te l : + 3 3 4 7 8 5 5 8 3 0 0 / F a x : + 3 3 4 7 8 5 5 8 3 1 9
00
Characteristics of the tubular motorisation
Features
Datas
Gear box
Input power
Consummation nominal torque
IP
Nominal
Torque (Nm)
Maximum
Rupture
Empty
Speed (RPM)
Nominal torque
End shaft
Material
Cartridge housing
Position limit switch sensor
Dimensions
Cable
Decomposition
Radial charge admissible
Frequency
Number of cycle per day
Using conditions
Full cycle time
Working temperature
Control of the position limit switch sensor
1/357
12 volts ±20%
6,6 A
IPx5
140 Nm
180 Nm
200 Nm
4,5 RPM
2,8 RPM
Square 16 mm
Zinc plated
Integrated electronics board
Ø10 mm
2x1,5² + 2x0,75² + button
250 kg
6 months a year
4
2mn 30s
+5°C to +45°C
Teaching on motor
red
black
_
M
The product complies to
NF EN 60335-1 and NF EN
61000-6-3.
Its integration in a complete
motorized swimming pool
cover complies to the
French standard NFP
90308. Manufacturer
recommendation: residual
current device (30mA
sensibility) on the electric
control panel.
+12 volts
Electrical diagram
for wiring version
12 volts Supply
(16 volts max)
0 volt
Motor cable
0 volt
blue
Control
knob
initialisation
switch
open or
close
Solar panel
12 V - 5W or 10W
_
M
+
red
red
+12 volts
orange
black
0 volt
black
Motor cable
yellow
0 volt
blue
Control
knob
initialisation
switch
Electrical diagram
for solar version
-
+
Battery
12 V
open or
close
Charger
with
integrated
thermal fuse
(7A)
Conçu et imprimé par SM - SIREM - mai 2008 - FT-MHS 12v_couv piscine_EN_rev 1.6
-